HAC system validation plots

FCC ID: ZNFP769

Test Report

Download: PDF
FCCID_1805726

                                                                              Date: 9/9/2012

Test Laboratory: UL CCS SAR Lab C

System Validation
Communication System: CW; Frequency: 835 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2339; ConvF(1, 1, 1); Calibrated: 1/20/2012
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1239; Calibrated: 6/6/2012
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (1);SEMCAD X Version 14.6.4 (4989)

CD835V3, E-Field/Measurement distance from the probe sensor center to Dipole =
10mm/Hearing Aid Compatibility Test (41x361x1): Measurement grid: dx=5mm, dy=5mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 114.3 V/m; Power Drift = -0.00 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 161.4 V/m
Near-field category: M4 (AWF 0 dB)

                                      PMF scaled E-field
                                       Grid 1 M4 Grid 2 M4 Grid 3 M4
                                       158.0 V/m      161.4 V/m   155.5 V/m
                                       Grid 4 M4      Grid 5 M4   Grid 6 M4
                                       81.61 V/m      83.31 V/m   80.93 V/m
                                       Grid 7 M4      Grid 8 M4   Grid 9 M4
                                       146.3 V/m      149.3 V/m   145.4 V/m




             0 dB = 161.4V/m = 44.16 dB V/m


                                                                              Date: 9/8/2012
Test Laboratory: UL CCS SAR Lab C

System Validation
Communication System: CW; Frequency: 1880 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2339; ConvF(1, 1, 1); Calibrated: 1/20/2012
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1239; Calibrated: 6/6/2012
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (1);SEMCAD X Version 14.6.4 (4989)

CD1880V3, E-Field/Measurement distance from the probe sensor center to Dipole =
10mm/Hearing Aid Compatibility Test (41x181x1): Measurement grid: dx=5mm, dy=5mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 133.7 V/m; Power Drift = -0.01 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 138.6 V/m
Near-field category: M2 (AWF 0 dB)

                                      PMF scaled E-field
                                       Grid 1 M2 Grid 2 M2 Grid 3 M2
                                       136.3 V/m      138.6 V/m   132.1 V/m
                                       Grid 4 M3      Grid 5 M3   Grid 6 M3
                                       88.95 V/m      92.07 V/m   90.20 V/m
                                       Grid 7 M2      Grid 8 M2   Grid 9 M2
                                       131.7 V/m      133.7 V/m   129.9 V/m




             0 dB = 138.6V/m = 42.84 dB V/m


                                                                              Date: 9/8/2012
Test Laboratory: UL CCS SAR Lab C

System Validation
Communication System: CW; Frequency: 1880 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2339; ConvF(1, 1, 1); Calibrated: 1/20/2012
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1239; Calibrated: 6/6/2012
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (1);SEMCAD X Version 14.6.4 (4989)

CD1730V3, E-Field/Measurement distance from the probe sensor center to Dipole =
10mm/Hearing Aid Compatibility Test (41x181x1): Measurement grid: dx=5mm, dy=5mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 151.3 V/m; Power Drift = -0.03 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 150.4 V/m
Near-field category: M2 (AWF 0 dB)

                                      PMF scaled E-field
                                       Grid 1 M2 Grid 2 M2 Grid 3 M2
                                       147.6 V/m      150.4 V/m   143.2 V/m
                                       Grid 4 M3      Grid 5 M3   Grid 6 M3
                                       102.1 V/m      105.5 V/m   102.8 V/m
                                       Grid 7 M2      Grid 8 M2   Grid 9 M2
                                       147.6 V/m      150.1 V/m   145.7 V/m




             0 dB = 150.4V/m = 43.54 dB V/m


                                                                             Date: 9/9/2012

Test Laboratory: UL CCS SAR Lab C

System Validation
Communication System: CW; Frequency: 835 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: H3DV6 - SN6157; ; Calibrated: 1/30/2012
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1239; Calibrated: 6/6/2012
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (1);SEMCAD X Version 14.6.4 (4989)

CD835V3, H-Field/Measurement distance from the probe sensor center to Dipole =
10mm/Hearing Aid Compatibility Test (41x361x1): Measurement grid: dx=5mm, dy=5mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 0.48 V/m; Power Drift = -0.01 dB
PMR not calibrated. PMF = 1.000 is applied.
H-field emissions = 0.45 A/m
Near-field category: M4 (AWF 0 dB)

                                        PMF scaled H-field
                                        Grid 1 M4 Grid 2 M4 Grid 3 M4
                                        0.39 A/m     0.41 A/m    0.39 A/m
                                        Grid 4 M4    Grid 5 M4   Grid 6 M4
                                        0.43 A/m     0.45 A/m    0.43 A/m
                                        Grid 7 M4    Grid 8 M4   Grid 9 M4
                                        0.38 A/m     0.40 A/m    0.38 A/m




             0 dB = 0.450A/m = -6.94 dB A/m


                                                                            Date: 9/9/2012

Test Laboratory: UL CCS SAR Lab C

System Validation
Communication System: CW; Frequency: 1880 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: H3DV6 - SN6157; ; Calibrated: 1/30/2012
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1239; Calibrated: 6/6/2012
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (1);SEMCAD X Version 14.6.4 (4989)

CD1880V3, H-Field/Measurement distance from the probe sensor center to Dipole =
10mm/Hearing Aid Compatibility Test (41x181x1): Measurement grid: dx=5mm, dy=5mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 0.47 V/m; Power Drift = 0.00 dB
PMR not calibrated. PMF = 1.000 is applied.
H-field emissions = 0.44 A/m
Near-field category: M2 (AWF 0 dB)

                                        PMF scaled H-field
                                        Grid 1 M2 Grid 2 M2 Grid 3 M2
                                        0.39 A/m    0.41 A/m    0.39 A/m
                                        Grid 4 M2   Grid 5 M2   Grid 6 M2
                                        0.43 A/m    0.44 A/m    0.43 A/m
                                        Grid 7 M2   Grid 8 M2   Grid 9 M2
                                        0.38 A/m    0.40 A/m    0.39 A/m




             0 dB = 0.440A/m = -7.13 dB A/m


                                                                            Date: 9/8/2012
Test Laboratory: UL CCS SAR Lab C

System Validation
Communication System: CW; Frequency: 1880 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: H3DV6 - SN6157; ; Calibrated: 1/30/2012
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1239; Calibrated: 6/6/2012
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (1);SEMCAD X Version 14.6.4 (4989)

CD1730V3, H-Field /Measurement distance from the probe sensor center to Dipole =
10mm/Hearing Aid Compatibility Test (41x181x1): Measurement grid: dx=5mm, dy=5mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 0.49 V/m; Power Drift = 0.00 dB
PMR not calibrated. PMF = 1.000 is applied.
H-field emissions = 0.46 A/m
Near-field category: M2 (AWF 0 dB)

                                        PMF scaled H-field
                                        Grid 1 M2 Grid 2 M2 Grid 3 M2
                                        0.39 A/m    0.41 A/m    0.39 A/m
                                        Grid 4 M2   Grid 5 M2   Grid 6 M2
                                        0.44 A/m    0.46 A/m    0.44 A/m
                                        Grid 7 M2   Grid 8 M2   Grid 9 M2
                                        0.39 A/m    0.40 A/m    0.39 A/m




             0 dB = 0.460A/m = -6.74 dB A/m