TCoil Test Report

FCC ID: ZNFLS885

Test Report

Download: PDF
FCCID_2324696

                                                                                                                          x
                                                                                                                     2
     PCTEST




                                         HEARING AID COMPATIBILITY
Applicant Name:                                                           Date of Testing:
LG Electronics MobileComm U.S.A, Inc.                                     6/9/2014
1000 Sylvan Avenue                                                        Test Site/Location:
Englewood Cliffs, NJ 07632                                                PCTEST Lab, Columbia, MD, USA
United States                                                             Test Report Serial No.:
                                                                          OY1406091182.2NF


FCC ID:                                         ZNFLS885

; APPLICANT:                                     LG ELECTRONICS MOBILECOMM U.S.A, INC. ;


Scope of Test:                                  Audio Band Magnetic Testing (T—Coil)
Application Type:                               Class II Permissive Change
FCC Rule Part(s):                               CFR §20.19(b)
HAC Standard:                                   ANSI C63.19—2011
EUT Type:                                       Portable Handset
Model(s):                                       LGLS885, LG—LS885, LS885
Test Device Serial No.:                         Pre—Production Sample [S/N: HAC (T—coil)]
Class II Permissive Change(s):                  See FCC Change Document
Original Grant Date:                            06/09/2014


C63.19—2011 HAC Category:                       T3 (SIGNAL TO NOISE CATEGORY)

This wireless portable device has been shown to be hearing—aid compatible under the above rated category, specified in ANSV/IEEE
Std. C63.19—2011 and has been tested in accordance with the specified measurement procedures. Test results reported herein
relate only to the item(s) tested. Hearing—Aid Compatibility is based on the assumption that all production units will be designed
electrically identical to the device tested in this report. North American Bands only.

I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and
are correct to the best of my knowledge and belief. 1 assume full responsibility for the completeness of these measurements and
vouch for the qualifications of all persons taking them.




      Randy Ortanez
      President                                                                                                   :ACCREDIT:ED
                                                                                                                  Testino centezos1.01




                              z. RCTEST                                                                            Reviewed by:
FCC ID:ZNFLS885               —’f\,—                     HAC (T—COIL) TEST REPORT                   @ LG               .
                                                                                                                   Quality Manager
Filename:                     Test Dates:                  EUT Type:
                                                                                                                   Page 1 of 37
0Y1406091182.2NF              61912014                     Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                 REV 3.0.M
                                                                                                                              03/24/714


                                   T A B L E                     O F           C O N T E N T S




1.    INTRODUCTION ................................................................................................................................... 3

2.    TEST SITE............................................................................................................................................. 4

3.    EUT DESCRIPTION .............................................................................................................................. 5

4.    ANSI C63.19-2011 PERFORMANCE CATEGORIES .......................................................................... 6

5.    METHOD OF MEASUREMENT ............................................................................................................ 8

6.    FCC 3G MEASUREMENTS ................................................................................................................ 18

7.    TEST SUMMARY ................................................................................................................................ 19

8.    MEASUREMENT UNCERTAINTY ...................................................................................................... 23

9.    EQUIPMENT LIST ............................................................................................................................... 24

10.    CALIBRATION CERTIFICATES ........................................................................................................ 25

11.    CONCLUSION ................................................................................................................................... 32

12.    REFERENCES .................................................................................................................................. 33

13.    TEST SETUP PHOTOGRAPHS ....................................................................................................... 35




                                                                                                                                           Reviewed by:
FCC ID:ZNFLS885                                                      HAC (T-COIL) TEST REPORT
                                                                                                                                           Quality Manager
Filename:                        Test Dates:                           EUT Type:
                                                                                                                                           Page 2 of 37
0Y1406091182.ZNF            6/9/2014                                   Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                                        REV 3.0.M
                                                                                                                                                   03/24/14


1.          INTRODUCTION

On July 10, 2003, the Federal Communications Commission (FCC) adopted new rules requiring wireless
manufacturers and service providers to provide digital wireless phones that are compatible with hearing
aids. The FCC has modified the exemption for wireless phones under the Hearing Aid Compatibility Act of
1998 (HAC Act) in WT Docket 01-309 RM-86581 to extend the benefits of wireless telecommunications to
individuals with hearing disabilities. These benefits encompass business, social and emergency
communications, which increase the value of the wireless network for everyone. An estimated more than
10% of the population in the United States show signs of hearing impairment and of that fraction, almost
80% use hearing aids. Approximately 500 million people worldwide and 30 million people in the United
States suffer from hearing loss.


Compatibility Tests Involved:

The standard calls for wireless communications devices to be measured for:
    RF Electric-field emissions
    T-coil mode, magnetic-signal strength in the audio band
    T-coil mode, magnetic-signal frequency response through the audio band
    T-coil mode, magnetic-signal and noise articulation index

The hearing aid must be measured for:
    RF immunity in microphone mode
    RF immunity in T-coil mode

In the following tests and results, this report includes the evaluation for a wireless communications
device.




                                             Figure 1-1 Hearing Aid in-vitu




1
    FCC Rule & Order, WT Docket 01-309 RM-8658

                                                                                                Reviewed by:
FCC ID:ZNFLS885                                       HAC (T-COIL) TEST REPORT
                                                                                                Quality Manager
Filename:                     Test Dates:              EUT Type:
                                                                                                Page 3 of 37
0Y1406091182.ZNF            6/9/2014                   Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                              REV 3.0.M
                                                                                                         03/24/14


2.          TEST SITE

I.      Test Facility / Accreditations:
Measurements were performed at an independent accredited PCTEST Engineering Lab located in
Columbia, MD, U.S.A.

                           PCTEST Lab is accredited to ISO 17025-2005 by the American Association for
                            Laboratory Accreditation (A2LA) in Specific Absorption Rate (SAR) testing, Hearing-
                            Aid Compatibility (HAC), Long-Term Evolution (LTE), CTIA Test Plans, and wireless
                            testing for FCC and Industry Canada Rules.
                           PCTEST Lab is accredited to ISO 17025 by U.S. National Institute of Standards and
                            Technology (NIST) under the National Voluntary Laboratory Accreditation Program
                            (NVLAP Lab code: 100431-0) in EMC, FCC and Telecommunications.
                           PCTEST facility is an FCC registered (PCTEST Reg. No. 90864) test facility with the
                            site description report on file and has met all the requirements specified in Section
                            2.948 of the FCC Rules and Industry Canada (IC-2451).
                           PCTEST Lab is a recognized U.S. Conformity Assessment Body (CAB) in EMC and
                            R&TTE (n.b. 0982) under the U.S.-EU Mutual Recognition Agreement (MRA).
                           PCTEST TCB is a Telecommunication Certification Body (TCB) accredited to
                            ISO/IEC Guide 65 by the American National Standards Institute (ANSI) in all scopes
                            of FCC Rules and all Industry Canada Standards (RSS).
                           PCTEST facility is an IC registered (IC-2451) test laboratory with the site description
                            on file at Industry Canada.




                                                                                                      Reviewed by:
FCC ID:ZNFLS885                                      HAC (T-COIL) TEST REPORT
                                                                                                      Quality Manager
Filename:                     Test Dates:              EUT Type:
                                                                                                      Page 4 of 37
0Y1406091182.ZNF            6/9/2014                   Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                 REV 3.0.M
                                                                                                            03/24/14


3.           EUT DESCRIPTION




FCC ID:                                                       ZNFLS885
Applicant:                                                    LG Electronics MobileComm U.S.A, Inc.
                                                              1000 Sylvan Avenue
                                                              Englewood Cliffs, NJ 07632
                                                              United States
Model(s):                                                     LGLS885, LG-LS885, LS885
Serial Number:                                                HAC (T-coil)
HW Version:                                                   Rev. 1.0
SW Version:                                                   LS885dv1
Antenna:                                                      Internal Antenna
HAC Test Configurations:                                      Cell. CDMA, 564*, 1013, 384, 777, BT Off, WLAN Off, LTE Off
                                                              PCS CDMA, 25, 600, 1175, BT Off, WLAN Off, LTE Off
                                                              *Note: Cell. CDMA ch. 564 is the Part 90S test channel.
EUT Type:                                                     Portable Handset


                                                                                      Voice over Digital
                      Band                                          Simultaneous                           WIFI Low    Additional GSM
  Air‐Interface                  Type Transport      HAC Tested                           Transport
                     (MHz)                                         But Not Tested                           Power     Power Reduction
                                                                                       OTT Capability

                      835
                                        VO              Yes        Yes: WIFI or BT           N/A             N/A            N/A
     CDMA            1900
                     EVDO               DT              No         Yes: WIFI or BT           Yes             N/A            N/A
                      850
      LTE            1900               DT              No         Yes: WIFI or BT           Yes             N/A            N/A
                     2600
                     2450
                     5200
      WIFI           5300               DT              No        Yes: CDMA or LTE           Yes             N/A            N/A
                     5500
                     5800
      BT              2450              DT              No        Yes: CDMA or LTE           N/A             N/A            N/A
 Type Transport
 VO = Voice Only
 DT = Digital Data ‐ Not intended for CMRS Service
                                               Table 3-1: ZNFLS885 HAC Air Interfaces




                                                                                                                        Reviewed by:
FCC ID:ZNFLS885                                                   HAC (T-COIL) TEST REPORT
                                                                                                                        Quality Manager
Filename:                        Test Dates:                       EUT Type:
                                                                                                                        Page 5 of 37
0Y1406091182.ZNF            6/9/2014                               Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                   REV 3.0.M
                                                                                                                              03/24/14


4.          ANSI C63.19-2011 PERFORMANCE CATEGORIES

I.      MAGNETIC COUPLING

Axial and Radial Field Intensity

     All orientations of the magnetic field, in the axial and radial position along the measurement plane
     shall be ≥ -18 dB(A/m) at 1 kHz in a 1/3 octave band filter per §8.3.1.
Frequency Response

     The frequency response of the axial component of the magnetic field shall follow the response curve
     specified in EIA RS-504-1983, over the frequency range 300 Hz – 3000 Hz per §8.3.2.

                                                                                                     MAGNETIC FIELD STRENGTH RELATIVE TO 1000 Hz
                                                                                         20
                         dB Relative to Value at 1 kHz




                                                                                                                     -4 dB/Oct.

                                                                                         10
                                                                                                                                                     +2 dB

                                                                                                           -2 dB
                                                                                           0
                                                                                                                                                                    -6 dB/Oct.


                                                                                         -10
                                                                                                         6 dB/Oct.



                                                                                         -20
                                                                                               300                 500                1000            2000                       3000
                                                                                                                                  FREQUENCY (Hz)

                                                    Figure 4-1
                    Magnetic field frequency response for Wireless Devices with an axial field
                                              ≤-15 dB (A/m) at 1 kHz

                                                                                                       MAGNETIC FIELD STRENGTH RELATIVE TO 1000 Hz
                                                                                         20


                                                                                                                   -4 dB/Oct.
                                                         dB Relative to Value at 1 kHz




                                                                                         10
                                                                                                                                                      +2 dB

                                                                                                         -2 dB
                                                                                          0

                                                                                                                                                               -7

                                                                                         -10

                                                                                                        6 dB/Oct.
                                                                                                                                                             -12
                                                                                         -20
                                                                                               300                 500                  1000          2000                       3000
                                                                                                                                  FREQUENCY (Hz)

                                                 Figure 4-2
            Magnetic Field frequency response for wireless devices with an axial field that exceeds
                                           -15 dB(A/m) at 1 kHz

                                                                                                                                                                                        Reviewed by:
FCC ID:ZNFLS885                                                                                                          HAC (T-COIL) TEST REPORT
                                                                                                                                                                                        Quality Manager
Filename:                                                                       Test Dates:                                 EUT Type:
                                                                                                                                                                                        Page 6 of 37
0Y1406091182.ZNF            6/9/2014                                                                                        Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                                                                                   REV 3.0.M
                                                                                                                                                                                              03/24/14


Signal Quality

     The table below provides the signal quality requirement for the intended audio magnetic signal from a
     wireless device. Only the RF immunity of the hearing aid is measured in T-coil mode. It is assumed
     that a hearing aid can have no immunity to an interference signal in the audio band, which is the
     intended reception band for this mode. The only criterion that can be measured is the RF immunity in
     T-coil mode. This is measured using the same procedure as the audio coupling mode at the same
     levels.

     The signal quality of the axial and radial components of the magnetic field was used to determine the
     T-coil mode category.


                                                         Telephone RF Parameters
                                     Category
                                                        Wireless Device Signal Quality
                                                    [(Signal + Noise)-to-noise ratio in dB]
                                            T1                    0 to 10 dB
                                            T2                   10 to 20 dB
                                            T3                    20 to 30 dB
                                            T4                      > 30 dB

                                                           Table 4-1
                                                 Magnetic Coupling Parameters




                                                                                              Reviewed by:
FCC ID:ZNFLS885                                           HAC (T-COIL) TEST REPORT
                                                                                              Quality Manager
Filename:                     Test Dates:                   EUT Type:
                                                                                              Page 7 of 37
0Y1406091182.ZNF            6/9/2014                        Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                         REV 3.0.M
                                                                                                    03/24/14


            METHOD OF MEASUREMENT


1.      Test Setup
     The equipment was connected as shown in an acoustic/RF hemi—anechoic chamber:




                                                __________      _______________________


                                                                                          l

                                                                            7/1,1, i
                                                                                                   obe   Sensor
                                                                                                                                     Y¥

                                                                                                                          D   Probe Amplifier


                             Sine tone, P.50, WN




                                                                    Figure 5—1
                                                       Validation Setup with Helmholtz Coll




                                                                                                                                      :
                                                                                                                          %       Amplifier


                                                                                                  :)       Probe Sensor




                                                                                    Figure 5—2
                                                                                T—Coil Test Setup




                                                            >                                                                                   Reviewed by:
FCC ID:ZNFLS885               z) PETEST                                               HAC (T—COIL) TEST REPORT                        @ LG          _        Y
                                  haymaviss nappeasunt .M                                                                                       Quality Manager
Filename:                     Test Dates:                                                     EUT Type:
                                                                                                                                                Page 8 of 37
OY1406091182.ZNF            6/9/2014                                                          Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                                              REV 3.0.M
                                                                                                                                                         03/24/14


II.     Scanning Mechanism

Manufacturer:                                TEM
Accuracy:                                    + 0.83 cm/imeter
Minimum Step Size:                           0.1 mm
Maximum speed                                6.1 cm/sec
Line Voltage:                                115 VAC
Line Frequency:                              60 Hz
Material Composite:                          Delrin (Acetal)
Data Control:                                Parallel Port                                             Figure 5—3
Dynamic Range (X—Y—Z):                       45 x 31.75 x 47 om                                  RF Near—Field Scanner

Dimensions:                                  36" x 25" x 38"
Operating Area:                              36" x 49" x 55"
Reflections:                                 <—20 dB (in anechoic chamber)



IIL.    ITU—T P.50 Artificial Voice
Manufacturer:                      ITU—T
Active Frequency                   100 Hz — 8 kHz
Range:
Stimulus Type:                     Male and Female, no spaces

Single Sample                      20.96 seconds
Duration:                            '
Activity Level:                    100%

                                                                                                      Figure 5—4
                                                                                          Spectral Characteristic of full P.50




                                                           Figure 5—5
                                               Temporal Characteristic of full P.50




                                               —                                                                    Reviewed by:
Foo ID:ZNFLSS35               ff\,m                            HAG (T—colL) TEsT REPORT               @ LG                          Y
                                                                                                                    Quality Manager
Filename:                     Test Dates:                       EUT Type:                                           p      9    of 37
0y1408091182.2NF              sorors                            Portable Handsct                                        age 0
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                 REV 3.0.M
                                                                                                                               03/24714


                                Figure 5-6 Magnetic Measurement Processing Steps

IV.     Test Procedure

      1. Ambient Noise Check per C63.19 §7.3.1
            a. Ambient interference was monitored using a Real-Time Analyzer between100-10,000 Hz
                with 1/3 octave filtering.
            b. “A-weighting” and Half-Band Integration was applied to the measurements.
            c. Since this measurement was measured in the same method as ABM2 measurements,
                this level was verified to be more than 10 dB below the lowest measurement signal
                (which is the highest ABM2 measurement for a T4 WD). Therefore the maximum noise
                level for a T4 WD with an ABM1 = -18 dBA/m is:
                                           -18 - 30 - 10= -58 dBA/m

      2. Measurement System Validation(See Figure 5-1)
            a. The measurement system including the probe, pre-amplifier and acquisition system were
               validated as an entire system to ensure the reliability of test measurements.

                b. ABM1 Validation
                   The magnetic field at the center of the Helmholtz coil is given by the equation (per
                   C63.19 Annex D.10.1):
                                                                            V
                                                                          N( )
                                                                NI           R
                                                         Hc           
                                                                     3
                                                              r 1.25     r 1.25 3
                                Where Hc = magnetic field strength in amperes per meter
                                      N = number of turns per coil

                     For the Helmholtz Coil, N=20; r=0.13m; R=10.193Ω and using V=29mV:

                                                         0.029
                                                  20  (       )
                                             Hc        10.193  0.31623 A / m  10dB ( A / m)
                                                  0.13  1.253
                     Therefore a pure tone of 1kHz was applied into the coils such that 29 mV was observed
                     across the 10 Ω resistor. The voltmeter used for measurement was verified to be capable
                     of measurements in the audio band range. This theoretically generates an expected field
                     of -10 dB(A/m) in the center of the Helmholtz coil which was used to validate the probe
                     measurement at -10dB(A/m). This was verified to be within ± 0.5 dB of the -10dB(A/m)
                     value (see Page 22).
                                                                                                  Reviewed by:
FCC ID:ZNFLS885                                         HAC (T-COIL) TEST REPORT
                                                                                                  Quality Manager
Filename:                     Test Dates:                 EUT Type:
                                                                                                  Page 10 of 37
0Y1406091182.ZNF            6/9/2014                      Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                REV 3.0.M
                                                                                                           03/24/14


                c.   Frequency Response Validation

                     The frequency response through the Helmholtz Coil was verified to be within 0.5 dB
                     relative to 1kHz, between 300 – 3000 Hz using the P.50 signal as shown below:




                                       Figure 5-7 Frequency Response Validation

                d. ABM2 Measurement Validation

                     WD noise measurements are filtered with A-weighting and Half-Band Integration over a
                     frequency range of 100Hz – 10kHz to process ABM2 measurements. Below is the
                     verification of the system processing A-weighting and Half-Band integration between
                     system input to output within 0.5 dB of the theoretical result:


                                                             Table 5-1
                                                ABM2 Frequency Response Validation
                                                      HBI, A -      HBI, A -
                                             f (Hz)  Measured     Theoretical dB Var.
                                                    (dB re 1kHz) (dB re 1kHz)
                                              100     -16.180        -16.170   -0.010
                                              125     -13.257        -13.250   -0.007
                                              160     -10.347        -10.340   -0.007
                                              200      -8.017         -8.010   -0.007
                                              250      -5.925         -5.920   -0.005
                                              315      -4.045         -4.040   -0.005
                                              400      -2.405         -2.400   -0.005
                                              500      -1.212         -1.210   -0.002
                                              630      -0.349         -0.350    0.001
                                              800      0.071           0.070    0.001
                                             1000      0.000           0.000    0.000
                                             1250      -0.503         -0.500   -0.003
                                             1600      -1.513         -1.510   -0.003
                                             2000      -2.778         -2.780    0.002
                                             2500      -4.316         -4.320    0.004
                                             3150      -6.166         -6.170    0.004
                                             4000      -8.322         -8.330    0.008
                                             5000     -10.573        -10.590    0.017
                                             6300     -13.178        -13.200    0.022
                                             8000     -16.241        -16.270    0.029
                                             10000    -19.495        -19.520    0.025




                                                                                                 Reviewed by:
FCC ID:ZNFLS885                                      HAC (T-COIL) TEST REPORT
                                                                                                 Quality Manager
Filename:                     Test Dates:             EUT Type:
                                                                                                 Page 11 of 37
0Y1406091182.ZNF            6/9/2014                  Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                            REV 3.0.M
                                                                                                       03/24/14


                                                                             ABM2 Frequency Response Validation (LISTEN)

                                                         10




                                                          0
                                                           100                                  1000                                            10000



                                                         -10




                                  dBV, A weighted, HBI
                                                         -20




                                                         -30

                                                                                                              HBI, A - Measured
                                                                                                              HBI, A - Theoretical

                                                         -40




                                                         -50
                                                                                            Frequency (Hz)


                                                                                Figure 5-8
                                                                    ABM2 Frequency Response Validation

                     The ABM2 result is a power sum from 100Hz to 10kHz with half-band integration and A-
                     weighting. To verify the power sum measurement, a power sum over the full band was
                     measured and verified to track with the source level (See Figure 5-9). Therefore the
                     setup in this step was used to verify the power sum post-processing for ABM2
                     measurements. See below block diagram:




                                                                          Figure 5-9
                                                                 ABM2 Validation Block Diagram

                     The power summed output results for a known input were compared to the multi-meter
                     results to verify any deviation in the post-processing implemented with the power-sum.

                                                                                  Table 5-2
                                                                           ABM2 Power Sum Validation
                                                                  WN Input      Power Sum              Multimeter-Full
                                                                                                                                     Dev (dB)
                                                                   (dBV)          (dBV)                     (dBV)

                                                                     -60           -60.36                    -60.2                     0.16
                                                                     -50           -50.19                    -50.13                    0.06
                                                                     -40           -40.14                    -40.03                    0.11
                                                                     -30           -30.13                    -30.01                    0.12
                                                                     -20           -20.12                     -20                      0.12
                                                                     -10           -10.14                     -10                      0.14


                                                                                                                                                        Reviewed by:
FCC ID:ZNFLS885                                                              HAC (T-COIL) TEST REPORT
                                                                                                                                                        Quality Manager
Filename:                     Test Dates:                                     EUT Type:
                                                                                                                                                        Page 12 of 37
0Y1406091182.ZNF            6/9/2014                                          Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                                                   REV 3.0.M
                                                                                                                                                              03/24/14


                                                                                                     ABM2 Power Sum Validation (LISTEN)

                                                                    -10




                                                                    -20




                                                                    -30




                                             Measured Level (dBV)
                                                                    -40

                                                                                                                                             Power Sum (dBV)
                                                                                                                                             Multimeter-Full (dBV)


                                                                    -50




                                                                    -60




                                                                    -70
                                                                          -60   -55    -50     -45        -40        -35         -30   -25       -20             -15       -10
                                                                                                                WN Input (dBV)



                                                                                              Figure 5-10
                                                                                       ABM2 Power Sum Validation

     3. Measurement Test Setup
           a. Fine scan above the WD (TEM)
                   i. A multitone signal was applied to the handset such that the phone acoustic
                      output was stable within 1dB over the probe settling time and with the acoustic
                      output level at the C63.19 specified levels (below). The measurement step size
                      was in 2 mm increments at a distance of 10 mm between the surface of the
                      wireless device as shown below:




                                                                                                 Figure 5-11
                                                                                             Measurement Distance
.
                           ii. After scanning, the planar field maximum point was determined. The position of
                               the probe was moved to this location to setup the test using the sound check
                               system.
                          iii. These steps were repeated for all T-coil orientations (axial and radial) per Figure
                               5-16 after a T-coil orientation was fully measured with the SoundCheck system.

                b. Speech Signal Setup to Base Station Simulator
                       i. C63.19 Table 7-1 states audio reference input levels for various technologies:

                                                                                                                                                                       Input Level
                                                                            Standard                              Technology
                                                                                                                                                                         (dBm0)
                                             TIA/EIA/IS-2000                                             CDMA                                                              -18
                                             J-STD-007                                                   GSM (217)                                                         -16
                                             T1/T1P1/3GPP                                                UMTS (WCDMA)                                                      -16
                                             iDENTM                                                      TDMA (22 and 11 Hz)                                               -18



                                                                                                                                                                                     Reviewed by:
FCC ID:ZNFLS885                                                                          HAC (T-COIL) TEST REPORT
                                                                                                                                                                                     Quality Manager
Filename:                     Test Dates:                                                    EUT Type:
                                                                                                                                                                                     Page 13 of 37
0Y1406091182.ZNF            6/9/2014                                                         Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                                                                                REV 3.0.M
                                                                                                                                                                                           03/24/14


                               The CMU200 audio levels were determined using base station simulator
                               manufacturer calibration procedures resulting in the below corresponding
                               voltages relative to handset test point level (in dBmO):

                                                                              Table 5§—3
                                                        CMU200 Voltage Input Levels for Audio
                                            dBmO Ref            Input Voltage           Notes

                                                                                        From CDMAZK "DECODER CAL"
                                            3.14 dBm0     10520 mV            0.4 dBV   ||(What is needed through Encoder
                                                                                        for FS)
                                             18 dBm0      92.260 mV       —20.7 dBV     |For 8k Enhanced (Low)


                C.   Real—Time Analyzer (RTA)
                               The Real—Time Analyzer was configured to analyze measurements using 1/3
                           Octave band weighted filtering.
                d.   WD Radio Configuration Selection
                           The device was chosen to be tested in the worst—case ABM2 condition under
                               RC1/S03 (CDMA — EVRC) (see below):




                                                         Figure 512
                                            Vocoder Analysis for ABM Noise

     4.     Signal Quality Data Analysis
                a.  Narrow—band Magnetic Intensity
                            The standard specifies a 1kHz 1/3 octave band minimum field intensity for a sine
                            tone. The ABM1 measurements were evaluated at 1kHz with 1/3 octave band
                            filtering over an averaged period of 10 seconds.
                b. Frequency Response
                         i. The appropriate frequency response curve was measured to curves in Figure 4—1
                            or Figure 4—2between 300 — 3000 Hz using digital linear averaging (limit lines
                            chosen according to measurement found in step 4a). A linear average over 3x
                            the length of the artificial voice signal (3x sampling) was performed. A 10 second
                            delay was configured in the measurement process of the stimulus to ensure
                             handset vocoder latency effects and echo cancellation devices (if any) were
                            appropriately stabilized during measurements.
                            The appropriate post—processing was applied according to the system processing
                            chain illustrated in Figure 5—13. All R10 frequencies were plotted with respect to
                            OdB at 1kHz value and aligned with respect to the EIA—504 mask.


Foo ID:2NFLSSES              eeresr                      HAc (T—coll) TEST REPORT                      @ LG             Reviewed   by:
                                                                                                                        Quality Manager
Filename:                    Test Dates:                   EUT Type:                                                    Page 14 of 37
ovi40so0t182.20r            srrzona                        Portable Handset
© 2014 PCTEST Enginesring Laboratory, mo.                                                                                    Revsom
                                                                                                                               O3r24M4


                                   Figure 5-13 Frequency Response Block Diagram

                          iii. The margin is represented by the closest measured data point on the curve to
                               the EIA-504 limit lines, in dB.

                c.   Signal Quality Index
                           i. Ensuring the WD was at maximum RF power, maximum volume, backlight on,
                              display on, maximum contrast setting, keypad lights on (when possible) with no
                              audio signal through the vocoder, the WD was measured over at least 100 Hz –
                              10,000 Hz, maximized over 5 seconds with a 50ms sample time for the ABM2
                              measurement (5 second time period is used in noise measurements under
                              standards such as IEEE 269, etc.).
                          ii. After applying half-band integration and A-weighting to the result, a power sum
                              was applied over each 1/3 octave bandwidth frequency for an ABM2 value.
                         iii. This result was subtracted from the ABM1 result in step a, to obtain the Signal
                              Quality.

V.      Test Setup

                                                                                                           Integrator



                                                                                                       1/3 Octave Bandpass
                                                                                                             Filter
                                                                   Probe Coil
                                                                 (Shown in Axial Position)

                                                                                                       RMS Voltmeter



                                                          Wireless Device                                  Graphics
                                                                                                           Recorder



                                                                              Reference
                                                                                                            Signal
                                                                             Base Station
                                             Antenna replaced                                               Source
                                                                              Simulator
                                             with Coaxial Connection




                                                                                                         Controller

                                                         Figure 5-14
                                                Audio Magnetic Field Test Setup

VI.     Deviation from C63.19 Test Procedure

None.




                                                                                                                             Reviewed by:
FCC ID:ZNFLS885                                                             HAC (T-COIL) TEST REPORT
                                                                                                                             Quality Manager
Filename:                     Test Dates:                                     EUT Type:
                                                                                                                             Page 15 of 37
0Y1406091182.ZNF            6/9/2014                                          Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                        REV 3.0.M
                                                                                                                                   03/24/14


VII.    Air Interface Technologies Tested

WIFI and all 3G packet services were not tested for this device since they are considered ‘Over—the—Top‘
applications and are not within the current definition of a managed CMRS service.

VIII. Wireless Device Channels and Frequencies

The frequencies listed in the table below are those that lie in the center of the bands used for cellular
telephony. Low, middle and high channels were tested in each band for FCC compliance evaluation to
ensure the maximum emission is captured across the entire band.

To facilitate setting of a base station simulator for ABM measurements, specific band plan channel
numbers are listed that may be used in lieu of the band center frequencies.

                                                       Table 54
                                           Center Channels and Frequencies
                                         Test frequencies & associated channels

                                              Channel                              Fri?n:s)‘cy

                                                     Cellular 850
                                            384 (CDMA)                               836.52
                                                        PCS 1900
                                            600 (CDMA)                      |         1880

IX.      RF Emission Effect on T—coil Measurements




                                            Figure §—15
      High power RF Emissions Effect with HAC Dipole on the T—coil Probe System 10mm between
                               dipole maximum and magnetic probe




FCC ID:2NFLSEE5            mReSresr                     Hac (T—colL) TEst REPoRT                 @ Le   Reviewed
                                                                                                             eviewed by:    by:
                                                                                                        uality Manager
Filename:                  Test bates:                   EUT Type:                                      Page age 16 190 or 37
ovi4dsoon 182 20r          serone                        Portable Handset
©2014 PCTEST Engineenng Laboratory, o.                                                                          REV 3.0M
                                                                                                                 o3rz44


X.      Test Flow
The flow diagram below was followed (From C63.19):

                                      Confirm calibration of test
                                       equipment
                                      Configure and validate test
                                       setup
                                      Establish WD reference level
                                      Scan for measurement locations




                                     Position and orient probe
                                     Measure desired audio band
                                     Signal strength
                                     Measure undesired audio
                                       Band signal strength



                                      Calculate signal strength
                                      Calculate signal quality
                                      Measure frequency response




                                              Both locations
                                               measured?
                                                                          N

                                                         Y



                                                Intensity and
                                             Frequency response            N
                                                 compliant?




                                                         Y


                                       Determine and record signal                   Done
                                            Quality category




                                                       Figure 5-16
                                             C63.19 T-Coil Signal Test Process



                                                                                            Reviewed by:
FCC ID:ZNFLS885                                           HAC (T-COIL) TEST REPORT
                                                                                            Quality Manager
Filename:                     Test Dates:                    EUT Type:
                                                                                            Page 17 of 37
0Y1406091182.ZNF            6/9/2014                         Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                       REV 3.0.M
                                                                                                  03/24/14


6.          FCC 3G MEASUREMENTS

Radio Configuration 1, Service Option 3 (thick, green data curve) was used for the testing as the worst-
case configuration for the handset due to vocoder gating from the EVRC logic. See below plot for ABM
noise comparison between operational field service options and radio configurations for a CDMA2000
handset:




                                                       Figure 6-1
                                             CDMA Audio Band Magnetic Noise

I.       ABM Measurements
                                                    Table 6-1
                                       FCC 3G ABM Measurements for ZNFLS885
      ABM2 Pre-Test (dBA/m), A, HBI
           RC1/SO3                RC3/SO3                            RC4/SO3       Orientation   Channel
             -39.00                 -55.75                            -55.95          Radial       600
      ABM1 Pre-Test (dBA/m)
           RC1/SO3                           RC3/SO3                 RC4/SO3       Orientation   Channel
            -13.160                           -13.170                 -13.020         Radial       600
           Mute on; Backlight on; Max Volume, Max Contrast
           CDMA: Power Control Bits = "All Up"




                                                 Figure 6-2
                            Audio Band Magnetic Curve Measurement Block Diagram


                                                                                                   Reviewed by:
FCC ID:ZNFLS885                                         HAC (T-COIL) TEST REPORT
                                                                                                   Quality Manager
Filename:                     Test Dates:                EUT Type:
                                                                                                   Page 18 of 37
0Y1406091182.ZNF            6/9/2014                     Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                              REV 3.0.M
                                                                                                         03/24/14


7.          TEST SUMMARY

I.      T-Coil Test Summary

                                                            Table 7-1
                                                   Table of Results for CDMA
                                                                                         Minimum
        C63.19 Sec.        Mode         Band                  Test Description                      Measured      Verdict
                                                                                          Limit*
                                                                                          dBA/m      dBA/m     PASS/FAIL
            8.3.1                                 Intensity, Axial                            -18      -2.3        PASS
            8.3.1                                 Intensity, Radial                           -18     -13.4        PASS
            8.3.4         CDMA         Cellular   Signal-to-Noise/Noise, Axial                20       39.9        PASS
            8.3.4                                 Signal-to-Noise/Noise, Radial               20       25.8        PASS
            8.3.2                                 Frequency Response, Axial                   0        1.6         PASS


            8.3.1                                 Intensity, Axial                            -18      -2.3        PASS
            8.3.1                                 Intensity, Radial                           -18     -13.5        PASS
            8.3.4         CDMA          PCS       Signal-to-Noise/Noise, Axial                20       39.5        PASS
            8.3.4                                 Signal-to-Noise/Noise, Radial               20       25.8        PASS
            8.3.2                                 Frequency Response, Axial                   0        1.5         PASS

Note: The above summary table represents the worst-case numerical values according to configurations
in Table 7-3.

                                                           Table 7-2
                                                  Consolidated Tabled Results

                                                  Volume                     Cellular                       PCS
                                                  Setting
                                                                        Axial      Radial           Axial         Radial
              Freq. Response Margin                                    PASS             N/A         PASS           N/A
            Magnetic Intensity Verdict Maximum                         PASS        PASS             PASS          PASS
                      FCC SNR Verdict                                  PASS        PASS             PASS          PASS

Note: Result shown is for T-coil category only.




                                                                                                                   Reviewed by:
FCC ID:ZNFLS885                                              HAC (T-COIL) TEST REPORT
                                                                                                                   Quality Manager
Filename:                     Test Dates:                      EUT Type:
                                                                                                                   Page 19 of 37
0Y1406091182.ZNF            6/9/2014                           Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                               REV 3.0.M
                                                                                                                          03/24/14


II.        Raw Handset Data

                                                          Table 7-3
                                                  Raw Data Results for CDMA

                                                                                  Cellular Band
                                      Volume
                                                               Axial                                Radial
                                                                                                                            6
                                                    1013        384         777        1013     384      777          564
           ABM1, dBA/m                              -2.30      -1.95       -2.31      -12.77   -12.43 -13.37         -13.42
           ABM2, dBA/m                             -43.35     -41.84      -42.73      -40.84   -38.98 -40.16         -39.23
   Ambient Noise, dBA/m                            -62.43     -62.43      -62.43      -62.25   -62.25 -62.25         -62.25
   Freq. Response Margin
                                                    1.66       1.59        1.58        N/A        N/A     N/A          N/A
                    (dB) Maximum
              S+N/N (dB)                            41.05      39.89       40.42      28.07    26.55     26.79        25.81
      S+N/N per orientation
                                                               39.89                                25.81
                      (dB)


                                                                                   PCS Band
                                      Volume
                                                               Axial                                Radial
                                                     25         600        1175         25      600     1175
           ABM1, dBA/m                              -2.16      -2.30       -2.26      -12.77   -13.47 -13.15
           ABM2, dBA/m                             -41.64     -41.91      -42.35      -38.61   -39.26 -39.55
   Ambient Noise, dBA/m                            -62.43     -62.43      -62.43      -62.25   -62.25 -62.25
   Freq. Response Margin
                                                    1.46       1.55        1.56        N/A        N/A     N/A
                    (dB) Maximum
              S+N/N (dB)                            39.48      39.61       40.09      25.84    25.79     26.40
      S+N/N per orientation
                                                               39.48                                25.79
                      (dB)
                                     [x,y] from
  T-coil Coordinates (cm) bottom left                         2.6, 2.6                              2.6, 3.2


Notes:

      1.    Power Configuration: CDMA: Power Control Bits = "All Up"
      2.    Phone Condition: Mute on; Backlight on; Max Volume, Max Contrast
      3.    Vocoder Configuration: RC1/SO3 (CDMA - EVRC)
      4.    'Radial' orientation refers to radial transverse.
      5.    Speech Signal: ITU-T P.50 Artificial Voice
      6.    Cell. CDMA ch. 564 is the Part 90S test channel.




                                                                                                                Reviewed by:
FCC ID:ZNFLS885                                            HAC (T-COIL) TEST REPORT
                                                                                                                Quality Manager
Filename:                     Test Dates:                   EUT Type:
                                                                                                                Page 20 of 37
0Y1406091182.ZNF            6/9/2014                        Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                           REV 3.0.M
                                                                                                                      03/24/14


III.    Frequency Response Graph




                                                                                            Figure 7-1
                                                                                   Axial Frequency Response

Note: User T-coil Mode (SettingsCall Hearing aids) was set to ON for Frequency Response
compliance. This frequency response represents the worst-case ABM2 test configuration according to
Table 7-3.

IV.     1 kHz Vocoder Application Check
                                                                                                  1kHz Tone Pass-through Check

                                                                       20



                                                                       10



                                                                        0
                                             Field Intensity (dBA/m)




                                                                       -10



                                                                       -20



                                                                       -30



                                                                       -40



                                                                       -50



                                                                       -60
                                                                             -70     -60   -50        -40             -30             -20   -10   0   10
                                                                                                            1kHz input level (dBm0)




This model was verified to be within the linear region for ABM1 measurements at -18 dBm0 for CDMA.
This measurement was taken in the axial configuration above the maximum location.

V.      Undesirable Audio Magnetic Band Plot (ABM2)




                                                                                 Figure 7-2
                                                                        Worst-case ABM2 Plot for WD

Note: This plot represents the data from the location/configuration resulting in the highest ABM2 result
shown in Table 7-3.
                                                                                                                                                           Reviewed by:
FCC ID:ZNFLS885                                                                                  HAC (T-COIL) TEST REPORT
                                                                                                                                                           Quality Manager
Filename:                     Test Dates:                                                         EUT Type:
                                                                                                                                                           Page 21 of 37
0Y1406091182.ZNF            6/9/2014                                                              Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                                                      REV 3.0.M
                                                                                                                                                                 03/24/14


VI.     T-Coil Validation Test Results




                                                     Figure 7-3
                                 Helmholtz Coil Validation for Frequency Response



                                                       Table 7-4
                                       Helmholtz Coil Validation Table of Results

                            Item                          Target                 Result   Verdict

      Signal Validation
      Frequency Response, from limits                   0 ± 0.5 dB                0.30    PASS
      Magnetic Intensity, -10 dBA/m                    -10 ± 0.5 dB              -9.763   PASS
      Noise Validation

      Axial Environmental Noise                        < - 58 dBA/m              -62.43   PASS

      Radial Environmental Noise                       < - 58 dBA/m              -62.25   PASS




                                                                                               Reviewed by:
FCC ID:ZNFLS885                                       HAC (T-COIL) TEST REPORT
                                                                                               Quality Manager
Filename:                     Test Dates:              EUT Type:
                                                                                               Page 22 of 37
0Y1406091182.ZNF            6/9/2014                   Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                          REV 3.0.M
                                                                                                     03/24/14


8.          MEASUREMENT UNCERTAINTY

                                                         Table 8-1
                                                Uncertainty Estimation Table
                                                                                                                      Standard
                                     Data +/- Data +/-                          Probability               Standard
             Contribution                                    Data Type                         Divisor               Uncertainty
                                       %        dB                              distribution             uncertainty
                                                                                                                        (dB)
 ABM Noise                            7.0%       0.29        Std. Dev.          Normal k=1      1.00        7.0%
 RF Reflections                       4.7%       0.20       Specification       Rectangular     1.73        2.7%
 Reference Signal Level              12.2%       0.50       Specification       Rectangular     1.73        7.0%
 Positioning Accuracy                10.0%       0.41       Uncertainty         Rectangular     1.73        5.8%
 Probe Coil Sensitivity              12.2%       0.50       Specification       Rectangular     1.73        7.0%
 Probe Linearity                      2.4%       0.10        Std. Dev.          Normal k=1      1.00        2.4%
 Cable Loss                           2.8%       0.12       Specification       Rectangular     1.73        1.6%
 Frequency Analyzer                   5.0%       0.21       Specification       Rectangular     1.73        2.9%
 System Repeatability                 5.0%       0.21        Std. Dev.          Normal k=1      1.00        5.0%
 WD Repeatability                     9.0%       0.37        Std. Dev.          Normal k=1      1.00        9.0%
 Positioner Accuracy                 1.0%        0.04       Specification       Rectangular     1.73        0.6%

 Combined standard uncertainty, uc (k=1)                                                                   17.7%          0.71
 Expanded uncertainty (k=2), 95% confidence level                                                          35.3%          1.31
             Notes:
            1. Test equipments are calibrated according to techniques outlined in NIS81, NIS3003 and NIST Tech Note 1297.
            2. All equipments have traceability according to NIST. Measurement Uncertainties are defined in further detail in
                NIS 81 and NIST Tech Note 1297 and UKAS M3003.

Measurement uncertainty reflects the quality and accuracy of a measured result as compared to the true
value. Such statements are generally required when stating results of measurements so that it is clear to
the intended audience that the results may differ when reproduced by different facilities. Measurement
results vary due to the measurement uncertainty of the instrumentation, measurement technique, and test
engineer. Most uncertainties are calculated using the tolerances of the instrumentation used in the
measurement, the measurement setup variability, and the technique used in performing the test. While
not generally included, the variability of the equipment under test also figures into the overall
measurement uncertainty. Another component of the overall uncertainty is based on the variability of
repeated measurements (so-called Type A uncertainty). This may mean that the Hearing Aid
compatibility tests may have to be repeated by taking down the test setup and resetting it up so that there
are a statistically significant number of repeat measurements to identify the measurement uncertainty. By
combining the repeat measurement results with that of the instrumentation chain using the technique
contained in NIS 81 and NIS 3003, the overall measurement uncertainty was estimated.




                                                                                                                     Reviewed by:
FCC ID:ZNFLS885                                            HAC (T-COIL) TEST REPORT
                                                                                                                     Quality Manager
Filename:                     Test Dates:                    EUT Type:
                                                                                                                     Page 23 of 37
0Y1406091182.ZNF            6/9/2014                         Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                REV 3.0.M
                                                                                                                           03/24/14


9.          EQUIPMENT LIST

                                                              Table 9-1
                                                            Equipment List
     Manufacturer         Model                          Description                Cal Date     Cal Interval    Cal Due    Serial Number

 Control Company     36934‐158                  Wall‐Mounted Thermometer             4/29/2014    Biennial       4/29/2016      122014488
      Listen       SoundConnect                   Microphone Power Supply            2/17/2014    Annual         2/17/2015     0899‐PS150
      Listen        SoundCheck                    Acoustic Analyzer System          10/11/2013     Annual       10/11/2014 04‐06‐5876‐SC2850
        NI               4474                       Data Acquisition Card              N/A                         N/A             N/A
 Rohde & Schwarz      CMU200                       Base Station Simulator            4/24/2014     Annual        4/24/2015    836371/0079
     Seekonk           NC‐100                       Torque Wrench (8" lb)           11/29/2011    Triennial     11/29/2014        21053
       TEM       Axial T‐Coil Probe                   Axial T‐Coil Probe             2/17/2014     Annual        2/17/2015      TEM‐1123
       TEM       Radial T‐Coil Probe                 Radial T‐Coil Probe             2/17/2014     Annual        2/17/2015      TEM‐1129
       TEM         Helmholtz Coil                      Helmholtz Coil                8/6/2013      Annual        8/6/2014        SBI 1052
       TEM                                   HAC System Controller with Software       N/A                         N/A             N/A
       TEM                                             HAC Positioner                  N/A                         N/A             N/A




                                                                                                                              Reviewed by:
FCC ID:ZNFLS885                                                HAC (T-COIL) TEST REPORT
                                                                                                                              Quality Manager
Filename:                     Test Dates:                        EUT Type:
                                                                                                                              Page 24 of 37
0Y1406091182.ZNF            6/9/2014                             Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                         REV 3.0.M
                                                                                                                                    03/24/14




             West Caldwell Calibration Laboratories Inc.




     Certificate of Calibration
                                                            for

                                               Axial T Coil Probe
                                    Manufactured by:            TEM CONSULTING
                                    Model No:                   Axial T Coil Probe
                                    Serial No:                  TEM—1123
                                    Calibration Recall No:      23889
                                                       Submitted By:
                                    Customer:              JUSTIN CHAO
                                    Company:               PCTEST ENGINEERING LAB
                                    Address:               6660—B DOBBIN ROAD
                                                           COLUMBIA             MD 21045


The subject instrument was calibrated to the indicated specification using standards traceable to the
National Institute of Standards and Tochnology or to accopted values of natural physical consfants.
Nakinnal In        tnta af Clandavda an        nchnalogy ar       to acconted   values af   natural   nhvsteal   ennetante


This document certifies that the instrument met the following specification upon its return to the
submitter,

West Caldwell Calibration Laboratories Procedure No.                        Axial T Cof TEM
Upon receipt for Calibration, the instrument was found to be:

                     Within        CX )       see attached Report of Calibration.

the tolerance of the indicated specification.

West Caldwell Calibration Laboratories‘ calibration control system meets the requirements, ISO
10012—1 MIL—STD—45662A, ANSUNCSEZ540—1, IEC Guide 25, ISO 9001:2008 and ISO 17025.

                                                                                                        favou
                                                                                                         2f 22h4
Note: With this Certificate, Report of Calibration is included.                    Approved by:

Calibration Date:                 17—Feb—14                                                           EZ

Certificate No:                   23889 —!                                         Felix Christopher (QA Mgr.)
GA Dos, #1051 Rev. 2.0 10M/01                    Certificate Page 1 of 1                    ISOAEC 17025f2005

                            West Caldwell                                                    @
                                Calibration                                                           2
                                                                                              AccrEpttED
                                                                                    Calibration Lab. Cert. # 1533.01


                                                                  HCATEMC_TEM—1123_Feb—17—2014

                                                                                                                                                ISO/EC 17025; 2005
                                                  West Caldwell
                                                   Calibration
       uncompromised calibration                      Laboratories, Inc.
1575 State Route 96, Victor NY 14564                                                                                                      Callbration Lab. Gert. # 1533.01



                                                      REPORT OF CALIBRATION
                       TEM Consulting LP Axial T Coil Probe                            Model No.: Axial T Coil Probe                                Serial No.: TEM—1123

       Company : PCTEST Engineering Lab.                                                                                                                L. D. No: 80582

Calibration results:                                                                                      Before data: .........                      After data:i .........
                   Probe Sensitivity measured with Helmholtz Coil
                                  Helmholtz Coil;     .                                                                          Before & after data same: ... X......
                               the number of turns on each coil;       10           No.
                               the radius of cach coil, in meters;    0.204        m                                      Laboratory Environment:
                             the current in the coils, in amperes.;   0.09         A                                 Ambient Temperature:       21.2                  °C
                                        Helmholtz Coil Constant;      7.09         Alm/V                                  Ambient Humidity:             29.1          % RH
                                  Helmholtz Coll magnetic field;      5.98         Aim                                    Ambient Pressure:            100.7          kPa
                                                                                                                            Calibration Date:       17—Feb—14
                                            Probe Sensitivity at      1000          Hz.                                  Re—calibration Due:        17—Feb—15
                                                              was     60.20        dBV/A/im                                  Report Number:            23889          1
                                                                      0.977        mV/A/im                                  Control Number:            23889
                                              Probe resistance         894         Ohms
The above listed instrument meets or exceeds the tested manufacturer‘s specifications.
‘This Calibration is traceable through NiST test numbers:                           287708
The expanded uncertainty of calbration: 0.30dB at 95% confidence level with a coverage factor of k=2.
Graph represents Probes Frequency Response.
                                                                                  Axial Probe Response
                                                                                                                                      —&—Measured Probe..
                  20

                  15

                  10
 Magnitude (dB)
                  LJ
                  o




                       100                                                    Freq. (Hz)       1000                                                                                10000

The above listed instrument was checked using calibration procedure documented in West Caldwell
Calibration Laboratories Inc. procedure :                                 Rev. 7.0 Jan. 24, 2014 Doc. # 1038 HCATEMC
Calibration was performed by West Caldwell Calibration Laboratories Inc. under Operating Procedures
intended to implement the requirements of 1S010012—1, IEC Guide 25, ANSU/NCSL 2540—1, (MIL—STD—45662A) and ISO 9001:2008, ISO 17025

                                                                                                                                                         C
                           Cal. Date:         17—Feb—2014                                                            Measurements performed by: ..........
Calibrated on WCCL system type 9700                                                                                                                Felix Christopher
This document shall not be reproduced, except in full, without the written approval from West Caldwell Cal, Labs, Inc.                Rev. 7.0 Jan. 24, 2014 Doc. # 1038 HCATEMC


                                                                                   Page 1 of 2



                                              £) RCTEST                                    .          .                                              @ LG


                                                                HCATEMC_TEM—1123_Feb—17—2014

                                             West Caldwell Calibration Laboratories Inc.
                                                                      1575 State Route 96, Victor NY 14564
                                                                     Tel. (585) 586—3900 FAX (585) 586—4327

                                                          Calibration Data Record
                                                                                                for
           TEM Consulting LP Axial T Coil Probe                                            Model No.: Axial T Coil Probe                           Serial No.: TEM—1123

                                                                                          Company : PCTEST Engineering Lab.

Test                  Function                                                                 Tolerance                                    Measured values
                                                                                                                                  Before          Out       Remarks

1.0                   Probe Sensitivity at                                      1000 Hz.                     dBV/A/m              —60.20

                                                                                                                        dB
2.0                   Probe Level Linearity                                                                              6         6.03
                                                                                        Ref. (0 dB)                      0         0.00
                                                                                                                        —6         —6.02
                                                                                                                        12        ~12.05

                                                                                                                        Hz
3.0                   Probe Frequency Response                                                                          100        ~19.9
                                                                                                                        126        ~17.9
                                                                                                                        158        ~16.0
                                                                                                                        200        ~13.9
                                                                                                                        251        ~12.0
                                                                                                                        316        ~10.0
                                                                                                                        398        —8.0
                                                                                                                        501        —6.0
                                                                                                                        631        ~4.0
                                                                                                                        794        —2.0
                                                                                        Ref. (0 dB)                 1000            0.0
                                                                                                                    1259            2.0
                                                                                                                    1585           4.0
                                                                                                                    1995           6.0
                                                                                                                    2512           7.9
                                                                                                                    3162           9.9
                                                                                                                    3981           11.9
                                                                                                                    5012           13.9
                                                                                                                    6310           15.9
                                                                                                                    7943           18.0
                                                                                                                   10000           20.2




Instruments used for calibration:                                                                                  Date of Cal.                Traceablity No.              Due Date
          HP                                         34401A                      S/N   36064102                     8—0ct—2013                 ;287708                    8—Oct—2014
          HP                                         34401A                      S/N   36102471                     8—0ct—2013                 ;287708                    8—Oct—2014
          HP                                         33120A                      S/N   36043716                     8—0ct—2013                 ;287708                    8—0ct—2014
   Briie! & KJaer                                        2133                    S/N   1583254                      6—Jan—2014                 683/284413—14              7—Jan—2015




                            Cal. Date:           17—Feb—2014                                                                      Tested by: Felix Christopher
Callbrated on WCCL system type 9700
This document shall not be reproduced, except In full, without the witten approval from West Caldwell Gal. Labs, Inc.               Rev. 7.0 Jan. 24, 2014 Doc. # 1038 HCATEMC




                                                                                       Page 2 of 2



                                       4) RCTEST


                West Caldwell Calibration Laboratories Inc.




       Certificate of Calibration
                                                                  for

                                                    Radial T Coil Probe
                                         Manufactured by:            TEM CONSULTING
                                         Model No:                   Radial T Coil Probe
                                         Serial No:                  TEM—1129
                                         Calibration Recall No:      23889
                                                          Submitted By:
                                         Customer:            JUSTIN CHAO
                                         Company:             PCTEST ENGINEERING LAB
                                         Address:             6660—B DOBBIN ROAD
                                                              COLUMBIA              MD 21045


  The subject instrument was calibrated to the indicated specification using standards traceable to the
  National Institute of Standards and Technologyor to accepted values of natural physical constants.
  This document certifies that the instrument met the following specification upon its return to the
  submitter.

  West Caldwell Calibration Laboratories Procedure No.                         Radial T C TEM
  Upon receipt for Calibration, the instrument was found to be:

                        Within          (X )       see attached Report of Calibration.

  the tolerance of the indicated specification.

  West Caldwell Calibration Laboratories‘ calibration control system meets the requirements, ISO
  10012—1 MIL—STD—45662A, ANSU/NCSL Z540—1, IEC Guide 25, ISO 9001:2008 and ISO 17025.

                                                                                                     SC
                                                                                                     2]f22[
  Note: With this Certificate, Report of Calibration is included.                   Approved by:



  Calibration Date:                    17—Feb—14

  Certificate No:                      23889 —2                                     Felix Christopher (QA Mgr.)
  OA Doe. #1051 Rev. 2.0 10/1/01                     Certificate Page 1 of 1               ISOAEC 170?5;2005

                               \West Galdwell
                          Afalibration
uncompromised calibration          Laboratories, Inc.
1575 State R              Vi       N           SA




                                                                                                       KA4 %DS 82

               £) RCTEST                                      .         .                                @ LG


                                                                   HCRTEMC_TEM—1129_Feb—17—2014

                                                                                                                                                    ISO/EC 17025: 2005
                                                   West Caldwell
                                                    Calibration                                                                                          {      j
       uncompromised calibration                       Laboratories, Inc.                                                                            {AccaEBirEp)
1575 State Route 96, Victor NY 14564                                                                                                        Calibration Lab. Gert, # 1833.01



                                                      REPORT OF CALIBRATION
                                                                                                for
                       TEM Consulting LP Radial T Coil Probe                               Model No.: Radial T Coil Probe                              Serial No.: TEM—1129

       Company : PCTEST Engineering Lab.                                                                                                                  1. D. No: 80583
Calibration results:                                                                                            Before datai .........                  After data: .........
                                Probe Sensitivity measured with Helmholtz Coil
                                                   Helmholtz Coll;                                                                  Before & after data same: ... X......
                               the numberof turns on each coil;           10           No.
                               the radius of each coil, in meters;      0.204          m                                        Laboratory Environment:
                             the current in the coils, in amperes.;      0.09          A                                   Ambient Temperature:           21.2           °C
                                        Helmholtz Coil Constant;         7.09          AlmiV                                  Ambient Humidity:           29.1           % RH
                                  Helmholtz Coil magnétic field;         5.98          Aim                                    Ambient Pressure:           100.7          kPa
                                                                                                                                Calibration Date:      17—Feb—14
                                           Probe Sensitivity at          1000          Hz.                                    Re—calibration Due:      17—Feb—15
                                                          was           —60.38         dBV/A/m                                    Report Number:         23889           =2
                                                                        0.957          mV/A/m                                    Control Number:         23889
                                              Probe resistance           900           Ohms
The above listed instrument meets or exceeds the tested manufacturer‘s specifications.
This Cailbration is traceable through NIST test numbers:                                287708
‘The expanded uncertainty of calibration: 0.304B at 95% confidence level with a coverage factor of k=2.
Graph represents Probes Frequency Response.
                                                                                     Radial Probe Response
                                                                                                                                      —&— Measured Probe Resp.
                  20
 Magnitude (dB)
                  o




                       100                                                      Freq. (Hz)        1000                                                                               10000

The above listed instrument was checked using calibration procedure documented in West Caldwell
Calibration Laboratories Inc. procedure :                                                                               Rev. 7.0 Jan. 24, 2014 Doc. # 1038 HCRTEMC



                                                                                                                                                             i
Calibration was performed by West Caldwell Calibration Laboratories Inc.under Operating Procedures
intended to implement the requirements of 1S010012—1, IEC Guide 25, ANSHNCSL Z540—1, (MIL—STD—45662A) and ISO 9001:2008, ISO 17025


                                      Cal. Date:     17—Feb—2014                                                   Measurements performed by:
Calibrated on WCCL system type 9700                                                                                                                  Felix Christopher
This document shall not be reproduced, excopt in full, withoutthe written approval from West Caldwell Cal. Labs. Inc.                   Rev. 7.0 Jan. 24, 2014 Doc. # 1038 HCRTEMG




                                                                                       Page 1 of 2



                                              4) RCTEST


                                                                HCRTEMC_TEM—1129_Feb—17—2014

                                              West Caldwell Calibration Laboratories Inc.
                                                                       1575 State Route 96, Victor NY 14564
                                                                      Tel. (585) 586—3900 FAX (585) 586—4327

                                                          Calibration Data Record
                                                                                                 for
           TEM Consulting LP Radial T Coil Probe                                           Model No.: Radial T Coil Probe                           Serial No.: TEM—1129

                                                                                           Company : PCTEST Engineering Lab.

Test                  Function                                                                  Tolerance                                    Measured values
                                                                                                                                   Before              Out               Remarks

1.0                   Probe Sensitivity at                                      1000 Hz.                      dBV/A/im             60.38

                                                                                                                         dB
2.0                   Probe Level Linearity                                                                               6         6.04
                                                                                        Ref. (0 dB)                       0         0.00
                                                                                                                         —6         —6.03
                                                                                                                         12        ~12.05

                                                                                                                      Hz
3.0                   Probe Frequency Response                                                                        100           ~19.9
                                                                                                                      126           ~17.9
                                                                                                                      158           ~15.9
                                                                                                                      200           13.9
                                                                                                                      251           ~12.0
                                                                                                                      316 _         ~10.0
                                                                                                                      398            —8.0
                                                                                                                      501            »6.0
                                                                                                                      631            —4.0
                                                                                                                      794            —2.0
                                                                                        Ref. (0 dB)                  1000            0.0
                                                                                                                     1259            2.0
                                                                                                                     1585            4.0
                                                                                                                     1995            6.0
                                                                                                                     2512            T.9
                                                                                                                     3162            9.9
                                                                                                                     3981           11.9
                                                                                                                     5012           13.9
                                                                                                                     6310           16.0
                                                                                                                     7943           18.0
                                                                                                                    10000           20.2




Instruments used for calibration:                                                                                   Date of Cal.                Traceability No.             Due Date
         HP                                          34401A                       S/N   36064102                     8—0ct—2013                 ,287708                    8—Oct—2014
         HP                                          34401A                       S/N   36102471                     8—O0ct—2013                287708                     8—0ct—2014
         HP                                          33120A                       S/N   36043716                     8—Oct—2013                 ;287708                    8—Oct—2014
   Brie! & KJeer                                         2133                     S/N   1583254                      6—Jan—2014                 683/7284413—14             T—Jan—2015




                            Cal. Date:           17—Feb—2014                                                                       Tested by: Felix Christopher
Calibrated on WCCL system type 9700
This document shall not be reproduced, except In full, without the written approval from West Galdwall Cal. Labs, Inc.               Rev. 7.0 Jan, 24, 2014 Doc, # 1038 HCRTEMC




                                                                                        Page 2 of 2



                                        4) RCTEST


11.         CONCLUSION

The measurements indicate that the wireless communications device complies with the HAC limits
specified in accordance with the ANSI C63.19 Standard and FCC WT Docket No. 01-309 RM-8658.
Precise laboratory measures were taken to assure repeatability of the tests. The tested device complies
with the requirements in respect to all parameters specific to the test. The test results and statements
relate only to the item(s) tested.

The measurement system and techniques presented in this evaluation are proposed in the ANSI standard
as a means of best approximating wireless device compatibility with a hearing-aid. The literature is under
continual re-construction.




                                                                                             Reviewed by:
FCC ID:ZNFLS885                               HAC (T-COIL) TEST REPORT
                                                                                             Quality Manager
Filename:                     Test Dates:       EUT Type:
                                                                                             Page 32 of 37
0Y1406091182.ZNF            6/9/2014            Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                        REV 3.0.M
                                                                                                   03/24/14


12.         REFERENCES

      1. ANSI C63.19-2011, American National Standard for Methods of Measurement of Compatibility
         between Wireless communication devices and Hearing Aids.”, New York, NY, IEEE, May 2011

      2. FCC Office of Engineering and Technology KDB, “285076 D01 HAC Guidance v04,” October 31,
         2013

      3. FCC Office of Engineering and Technology KDB, “285076 D02 T-Coil Testing for CMRS IP
         v01r01,” October 31, 2013

      4. FCC Public Notice DA 06-1215, Wireless Telecommunications Bureau and Office of Engineering
         and Technology Clarify Use of Revised Wireless Phone Hearing Aid Compatibility Standard, June
         6, 2006

      5. FCC 3G Review Guidance, Laboratory Division OET FCC, May/June 2006

      6. Berger, H. S., “Compatibility Between Hearing Aids and Wireless Devices,” Electronic Industries
         Forum, Boston, MA, May, 1997

      7. Berger, H. S., “Hearing Aid and Cellular Phone Compatibility: Working Toward Solutions,”
         Wireless Telephones and Hearing Aids: New Challenges for Audiology, Gallaudet University,
         Washington, D.C., May, 1997 (To be reprinted in the American Journal of Audiology).

      8. Berger, H. S., “Hearing Aid Compatibility with Wireless Communications Devices, “ IEEE
         International Symposium on Electromagnetic Compatibility, Austin, TX, August, 1997.

      9. Bronaugh, E. L., “Simplifying EMI Immunity (Susceptibility) Tests in TEM Cells,” in the 1990 IEEE
         International Symposium on Electromagnetic Compatibility Symposium Record, Washington,
         D.C., August 1990, pp. 488-491

      10. Byme, D. and Dillon, H., The National Acoustics Laboratory (NAL) New Procedure for Selecting
          the Gain and Frequency Response of a Hearing Aid, Ear and Hearing 7:257-265, 1986.

      11. Crawford, M. L., “Measurement of Electromagnetic Radiation from Electronic Equipment using
          TEM Transmission Cells, “ U.S. Department of Commerce, National Bureau of Standards, NBSIR
          73-306, Feb. 1973.

      12. Crawford, M. L., and Workman, J. L., “Using a TEM Cell for EMC Measurements of Electronic
          Equipment,” U.S. Department of Commerce, National Bureau of Standards. Technical Note 1013,
          July 1981.

      13. EHIMA GSM Project, Development phase, Project Report (1st part) Revision A. Technical-
          Audiological Laboratory and Telecom Denmark, October 1993.

      14. EHIMA GSM Project, Development phase, Part II Project Report. Technical-Audiological
          Laboratory and Telecom Denmark, June 1994.

      15. EHIMA GSM Project Final Report, Hearing Aids and GSM Mobile Telephones: Interference
          Problems, Methods of Measurement and Levels of Immunity. Technical-Audiological Laboratory
          and Telecom Denmark, 1995.

                                                                                              Reviewed by:
FCC ID:ZNFLS885                                 HAC (T-COIL) TEST REPORT
                                                                                              Quality Manager
Filename:                     Test Dates:        EUT Type:
                                                                                              Page 33 of 37
0Y1406091182.ZNF            6/9/2014             Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                         REV 3.0.M
                                                                                                    03/24/14


     16. HAMPIS Report, Comparison of Mobile phone electromagnetic near field with an upscaled
         electromagnetic far field, using hearing aid as reference, 21 October 1999.

     17. Hearing Aids/GSM, Report from OTWIDAM, Technical-Audiological Laboratory and Telecom
         Denmark, April 1993.

     18. IEEE 100, The Authoritative Dictionary of IEEE Standards Terms, Seventh Edition.

     19. Joyner, K. H, et. al., Interference to Hearing Aids by the New Digital Mobile Telephone System,
         Global System for Mobile (GSM) Communication Standard, National Acoustic Laboratory,
         Australian Hearing Series, Sydney 1993.

     20. Joyner, K. H., et. al., Interference to Hearing Aids by the Digital Mobile Telephone System, Global
         System for Mobile Communications (GSM), NAL Report #131, National Acoustic Laboratory,
         Australian Hearing Series, Sydney, 1995.

     21. Kecker, W. T., Crawford, M. L., and Wilson, W. A., “Contruction of a Transverse Electromagnetic
         Cell”, U.S. Department of Commerce, National Bureau of Standards, Technical Note 1011, Nov.
         1978.

     22. Konigstein, D., and Hansen, D., “A New Family of TEM Cells with enlarged bandwidth and
         Optimized working Volume,” in the Proceedings of the 7th International Symposium on EMC,
         Zurich, Switzerland, March 1987; 50:9, pp. 127-132.

     23. Kuk, F., and Hjorstgaard, N. K., “Factors affecting interference from digital cellular telephones,”
         Hearing Journal, 1997; 50:9, pp 32-34.

     24. Ma, M. A., and Kanda, M., ”Electromagnetic Compatibility and Interference Metrology,” U.S.
         Department of Commerce, National Bureau of Standards, Technical Note 1099, July 1986, pp.
         17-43.

     25. Ma, M. A., Sreenivashiah, I. , and Chang, D. C., “A Method of Determining the Emission and
         Susceptibility Levels of Electrically Small Objects Using a TEM Cell,” U.S. Department of
         Commerce, National Bureau of Standards, Technial Note 1040, July 1981.

     26. McCandless, G. A., and Lyregaard, P. E., Prescription of Gain/Output (POGO) for Hearing Aids,
         Hearing Instruments 1:16-21, 1983

     27. Skopec, M., “Hearing Aid Electromagnetic Interference from Digital Wireless Telephones, “IEEE
         Transactions on Rehabilitation Engineering, vol. 6, no. 2, pp. 235-239, June 1998.

     28. Technical Report, GSM 05.90, GSM EMC Considerations, European Telecommunications
         Standards Institute, January 1993.

     29. Victorian, T. A., “Digital Cellular Telephone Interference and Hearing Aid Compatibility—an
         Update,” Hearing Journal 1998; 51:10, pp. 53-60

     30. Wong, G. S. K., and Embleton, T. F. W., eds., AIP Handbook of Condenser Microphones: Theory,
         Calibration and Measurements, AIP Press.




                                                                                                  Reviewed by:
FCC ID:ZNFLS885                                  HAC (T-COIL) TEST REPORT
                                                                                                  Quality Manager
Filename:                     Test Dates:          EUT Type:
                                                                                                  Page 34 of 37
0Y1406091182.ZNF            6/9/2014               Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                             REV 3.0.M
                                                                                                        03/24/14