HAC RF Test Report1

FCC ID: ZNFLS751

Test Report

Download: PDF
FCCID_2578665

        HAC RF EMISSIONS TEST REPORT


              FCC 47 CFR § 20.19
               ANSI C63.19-2011

                    For
CDMA/LTE PHONE + BLUETOOTH, & 2.4GHz DTS b/g/n

              FCC ID: ZNFLS751
    Model Name(s): LG-LS751, LS751, LGLS751


          Report Number: 15I20232-S3
             Issue Date: 3/30/2015

                Prepared for
   LG ELECTRONICS MOBILECOMM U.S.A., INC.
             1000 SYLVAN AVE.
         ENGLEWOOD CLIFFS, NJ 07632

                  Prepared by
        UL VERIFICATION SERVICES INC.
            47173 BENICIA STREET
          FREMONT, CA 94538, U.S.A.
              TEL: (510) 771-1000
              FAX: (510) 661-0888




             NVLAP LAB CODE 200065-0


Report No.: 15I20232-S3                                                                          Issue Date: 3/30/2015

Revision History
 Rev.    Date             Revisions                                                        Revised By
 --      3/30/2015        Initial Issue                                                    --




                                                    Page 2 of 18
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20232-S3                                                                                                     Issue Date: 3/30/2015

                                                             Table of Contents
1.      Attestation of Test Results ............................................................................................................. 4

2.      Test Methodology ........................................................................................................................... 5

3.      Facilities and Accreditation ........................................................................................................... 5

4.      Calibration and Uncertainty ........................................................................................................... 5
     4.1.     Measuring Instrument Calibration ............................................................................................... 5
     4.2.     Measurement Uncertainty ........................................................................................................... 6

5.      Device Under Test........................................................................................................................... 7
     5.1.     Air Interfaces and Operating Mode ............................................................................................. 7

6.      System Specifications .................................................................................................................... 8

7.      System Validation ........................................................................................................................... 9
     7.1.     System Validation Results ........................................................................................................ 10

8.      Modulation Interference Factor (MIF) .......................................................................................... 11

9.      Average Antenna Input Power & Evaluation for Low-power Exemption................................... 12

10. HAC RF Emissions Test Procedure ............................................................................................. 13

11. RF Emissions Measurement Criteria ........................................................................................... 16

12. HAC (RF Emissions) Test Results ............................................................................................... 16
     12.1. Worst Case RF Emission Test Plot ........................................................................................... 17

Appendixes .......................................................................................................................................... 18
     A_15I20232v0 Setup Photo ................................................................................................................. 18
     B_15I20232v0 System Validation Plots ............................................................................................... 18
     C_15I20232v0 RF Emissions Test Plots.............................................................................................. 18
     D_15I20232v0 MIF Attestation Letter .................................................................................................. 18
     E_15I20232v0 Probe Cal. Certificates ................................................................................................. 18
     F_15I20232v0 Dipole Cal. Certificates ................................................................................................ 18
     G_15I20232v0 UID Specification ......................................................................................................... 18




                                                    Page 3 of 18
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20232-S3                                                                          Issue Date: 3/30/2015

1. Attestation of Test Results
Applicant Name                    LG ELECTRONICS MOBILECOMM U.S.A., INC.
FCC ID                            ZNFLS751
Model Name(s)                     LG-LS751, LS751, LGLS751
Applicable Standards              FCC 47 CFR § 20.19
                                  ANSI C63.19-2011
                                  Published RF exposure KDB procedures
Device Category                   Portable
Exposure Category                 General Population/Uncontrolled Exposure
HAC Rating                        M4
Date Tested                       3/9/2015 to 3/11/2015
Test Results                      Pass
 UL Verification Services Inc. tested the above equipment in accordance with the requirements set forth in the
 above standards. All indications of Pass/Fail in this report are opinions expressed by UL Verification Services Inc.
 based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into
 account and are published for informational purposes only. The test results show that the equipment tested is
 capable of demonstrating compliance with the requirements as documented in this report.
Note: The results documented in this report apply only to the tested sample, under the conditions and modes of
operation as described herein. This document may not be altered or revised in any way unless done so by UL
Verification Services Inc. and all revisions are duly noted in the revisions section. Any alteration of this document
not carried out by UL Verification Services Inc. will constitute fraud and shall nullify the document. This report must
not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any agency of
the Federal Government, or any agency of any government (NIST Handbook 150, Annex A). This report is written
to support regulatory compliance of the applicable standards stated above.
 Approved & Released By:                                      Prepared By:




Devin Chang                                                 Coltyce Sanders
Senior Engineer                                             Laboratory Engineer
UL Verification Services Inc.                               UL Verification Services Inc.




                                                    Page 4 of 18
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20232-S3                                                                                    Issue Date: 3/30/2015

2. Test Methodology
The tests documented in this report were performed in accordance with ANSI C63.19-2011 Methods of
Measurement of Compatibility between Wireless Communications Devices and Hearing Aids, FCC
published KDB 285076 D01 HAC Guidance v04 and TCB workshop updates.



3. Facilities and Accreditation
The test sites and measurement facilities used to collect data are located at
              47173 Benicia Street                                47266 Benicia Street
                   SAR Lab C                                            SAR Lab 2

UL Verification Services Inc. is accredited by NVLAP, Laboratory Code 200065-0. The full scope of accreditation
can be viewed at http://ts.nist.gov/standards/scopes/2000650.htm Calibration and Uncertainty



4. Calibration and Uncertainty
4.1.     Measuring Instrument Calibration
The measuring equipment utilized to perform the tests documented in this report has been calibrated in
accordance with the manufacturer's recommendations, and is traceable to recognized national
standards.
                                                                                                               Cal. Due date
Name of Equipment                       Manufacturer               Type/Model                 Serial No.
                                                                                                              MM DD Year
HP Signal Generator                         HP                      8665B                   3546A00784         6 23 2015
Power Meter                                 HP                       437B                   3125U09516        10 6 2015
Power Meter                               Agilent                  N1911A                   MY53060016         8    7 2015
Power Sensor                              Agilent                  E9323A                   MY53070003         5    1 2015
Power Sensor                              Agilent                   8481A                   3318A95392        10 6 2015
Amplifier                                 MITEQ            AMF-4D-00400600-50-30P             1622052               N/A
Bi-directional coupler                Werlatone, Inc.            C8060-102                      2711                N/A
DC Power Supply                      Sorensen Ametek               XT20-3                   1318A00530              N/A
Robot Remote Control                      Stäubli                   CS8C                         N/A                N/A
DASY5 Measurement Server                 SPEAG                  SEUMS001BA                      1041                N/A
Probe Alignment Unit                     SPEAG                     LB (V2)                       261                N/A
Data Acquisition Electronics             SPEAG                      DAE4                        1259           1 14 2016
E-Field Probe                            SPEAG                    ER3DV6*                       2450           8 26 2015
Calibration Dipole                       SPEAG                    CD835V3                       1175           5 19 2015
Calibration Dipole                       SPEAG                   CD1880V3                       1159           5 19 2015
Calibration Dipole                       SPEAG                   CD2600V3                       1008           8 21 2015
Radio Communication Tester                 R &S                   CMU 500                     125326           1 19 2016

Note(s):
*: According to SPEAG’s Technical Report, “MIF Verification”, Doc # TR-FB-12.09.04-1, issued date: 9/4/2012. E-field probes are
calibrated with specified uncertainty according to ISO 17025 as described in their calibration certificate. The MIF according to the
definition in ANSI C63.19 is specific for a modulation and can therefore be used as a constant value if the probe has been PMR
calibrated.




                                                    Page 5 of 18
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20232-S3                                                                                Issue Date: 3/30/2015

4.2.     Measurement Uncertainty
HAC Uncertainty Budget According to ANSI C63.19
                                            Uncertainty                                                     Std. Unc.(±%)
             Error Description                                 Probe Dist.   Div.    (Ci) E   (Ci) H
                                             value (±%)                                                      E         H
Measurement System
Probe Calibration                                        5.1       N           1       1        1           5.1      5.10
Axial Isotropy                                           4.7       R         1.732     1        1           2.7      2.71
Sensor Displacement                                     16.5       R         1.732     1      0.145         9.5      1.38
Boundary Effects                                         2.4       R         1.732     1        1           1.4      1.39
Phantom Boundary Effects                                 7.2       R         1.732     1        0           4.1      0.00
Linearity                                                4.7       R         1.732     1        1           2.7      2.71
Scaling to PMR Calibration                              10.0       R         1.732     1        1           2.8      5.77
System Detection Limit                                   1.0       R         1.732     1        1           0.6      0.58
Readout Electronics                                      0.3       N           1       1        1           0.3      0.30
Response Time                                            0.8       R         1.732     1        1           0.5      0.46
Integration Time                                         2.6       R         1.732     1        1           1.5      1.50
RF Ambient Conditions                                    3.0       R         1.732     1        1           1.7      1.73
RF Reflections                                          12.0       R         1.732     1        1           6.9      6.93
Probe Positioner                                         1.2       R         1.732     1       0.67         0.7      0.46
Probe Positioning                                        4.7       R         1.732     1       0.67         2.7      1.82
Extrapolation and Interpolation                          1.0       R         1.732     1        1           0.6      0.58
Test sample Related
Test Positioning Vertical                               4.7        R         1.732     1      0.67          2.7      1.82
Test Positioning Lateral                                1.0        R         1.732     1       1            0.6      0.58
Device Holder and Phantom                               2.4        R         1.732     1       1            1.4      1.39
Power Drift                                             5.0        R         1.732     1       1            2.9      2.89
Phantom and Setup Related
Phantom Thickness                                       2.4        R         1.732     1      0.67          1.4      0.93
Combined Std. Uncertainty                                                                                  15.4      12.2
Expanded Std. Uncertainty on Power                                                                         30.8      24.4
Expanded Std. Uncertainty on Field                                                                         15.4      12.2
Notesfor table
1. N - Nomal
2. R - Rectangular
3. Div. - Divisor used to obtain standard uncertainty
4. Ci - is te sensitivity coefficient




                                                    Page 6 of 18
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20232-S3                                                                                         Issue Date: 3/30/2015


5. Device Under Test
 Normal operation               Held to head
                               ☒ Normal Battery Cover
                               ☐ Normal Battery Cover with NFC
 Back Cover                    ☐ Wireless Charger Battery Cover
                               ☐ Wireless Charger Battery Cover with NFC
                               ☐ The rechargeable battery is not user accessible.

5.1.       Air Interfaces and Operating Mode
                                                                                                       Voice over
                                                                                                                               Additional
                                                                                       Concurrent        digital      Wi-Fi
     Air-              Bands                Type       HAC     Simultaneous but not                                              GSM
                                                                                      HAC Tested       Transport       Low
  Interface            (MHz)              Transport   Tested          Tested                                                    Power
                                                                                      or not Tested       OTT         Power
                                                                                                                               Reduction
                                                                                                       Capability
   CDMA             BC 0 / 1 / 10           VD         Yes        Yes – Wi-Fi/BT       Not tested1        NA           NA         NA

   EVDO             BC 0 / 1 / 10            DT        No         Yes – Wi-Fi/BT           NA             NA           NA         NA

 LTE - FDD     2 / 4 / 5 / 12 / 25 / 26     VD         No2        Yes – Wi-Fi/BT       Not tested1        Yes          NA         NA
                                                                                                 1
 LTE - TDD               41                 VD         Yes        Yes – Wi-Fi/BT       Not tested         Yes          NA         NA

   Wi-Fi               2400                  DT        No         Yes – WWAN           Not tested1        NA           No         NA
                                                                                                 1
    BT                 2400                  DT        No         Yes – WWAN           Not tested         NA           NA         NA
   Type Transport                                                       Note:
   VO = Voice only                                                      1. No concurrent mode was found to be the Worst Case mode
   DT = Digital Transport                                               2. No associated T-Coil measurement has been made in
   VD = CMRS and Data transport (HAC Tested)                                accordance with 285076 D02 T-Coil testing for CMRS IP from
                                                                            October 2013 TCB workshop.




                                                    Page 7 of 18
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20232-S3                                                                            Issue Date: 3/30/2015


6. System Specifications
E-field measurements are performed using the DASY5 automated dosimetric assessment system. The DASY5 is
made by Schmid & Partner Engineering AG (SPEAG) in Zurich, Switzerland.
The DASY5 HAC Extension consists of the following parts:
Test Arch Phantom
The specially designed Test Arch allows high precision positioning of both the device and any of the validation
dipoles.
ER3DV6 Isotropic E-Field Probe
Construction:             One dipole parallel, two dipoles normal to probe axis Built-in shielding against static
                          charges PEEK enclosure material (resistant to organic solvents, e.g., glycolether)
Calibration:              In air from 100 MHz to 3.0 GHz (absolute accuracy ±6.0%, k=2)
Frequency:                100 MHz to > 6 GHz; Linearity: ± 0.2 dB (100 MHz to 3 GHz)
Directivity:              ± 0.2 dB in air (rotation around probe axis)
                          ± 0.4 dB in air (rotation normal to probe axis)
Dynamic Range:            2 V/m to > 1000 V/m; Linearity: ± 0.2 dB
Dimensions:               Overall length: 330 mm (Tip: 16 mm)
                          Tip diameter: 8 mm (Body: 12 mm)
                          Distance from probe tip to dipole centers: 2.5 mm
                          The closest part of the sensor element is 1.1 mm closer to the tip
Application:              General near-field measurements up to 6 GHz
                          Field component measurements




                                                    Page 8 of 18
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20232-S3                                                                          Issue Date: 3/30/2015

7. System Validation
The test setup was validated when first configured and verified periodically thereafter to ensure proper function.
The procedure provided in this section is a validation procedure using dipole antennas for which the field levels
were computed by numeric modeling.
Procedure
Place a dipole antenna meeting the requirements given in ANSI C63.19-2011 in the normally occupied by the WD.
The dipole antenna serves as a known source for an electrical and magnetic output. Position the E-field probe so
that the following occurs:
‧ The probes and their cables are parallel to the coaxial feed of the dipole antenna
‧ The probe cables and the coaxial feed of the dipole antenna approach the measurement area from opposite
  directions
‧ The center point of the probe element(s) is 15 mm from the closest surface of the dipole elements.
Scan the length of the dipole with the E-field probe and record the two maximum values found near the dipole ends.
Average the two readings and compare the reading to the expected value in the calibration certificate or the
expected value in this standard.


                                                   Setup diagram




                                                    Page 9 of 18
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20232-S3                                                                                   Issue Date: 3/30/2015

7.1.      System Validation Results
                                                            Max. measured from    Average max.    E-field Target
                                            Input Power                                                            Deviation1)
   Date      Calibration Dipole   f (MHz)                 above high  above low    above arm      Values (V/m)
                                               (mW)                                                                   (%)
                                                          end (V/m)   end (V/m)      (V/m)       (From SPEAG)
                CD835V3
 3/9/2015                          835         100         118.10      114.00        116.05          107.0            8.46
                 SN 1175
                CD1880V3
 3/9/2015                          1880        100          85.10       89.13        87.12           89.40           -2.56
                 SN 1159
                CD2600V3
 3/10/2015                         2600        100          79.15       80.48        79.82           85.60           -6.76
                 SN 1008
                CD835V3
 3/12/2015                         835         100          98.77      108.80        103.79          107.0           -3.00
                 SN 1175
                CD2600V3
 3/12/2015                         2600        100          82.08       89.36        85.72           85.60            0.14
                 SN 1008


Notes:
1) Delta (Deviation) % = 100 * (Measured value minus Target value) divided by the Target value. Deltas within ±25% are
    acceptable, of which 12% is deviation and 13% is measurement uncertainty.
2) The maximum E-field or were evaluated and compared to the target values provided by SPEAG in the calibration certificate
    of specific dipoles.
3) Please refer to the appendix for detailed measurement data and plots.




                                                   Page 10 of 18
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20232-S3                                                                          Issue Date: 3/30/2015


8. Modulation Interference Factor (MIF)
The HAC Standard ANSI C63.19-2011 defines a new scaling using the Modulation Interference Factor (MIF) which
replaces the need for the Articulation Weighting Factor (AWF) during the evaluation and is applicable to any
modulation scheme.
The Modulation Interference factor (MIF, in dB) is added to the measured average E-field (in dBV/m) and converts
it to the RF Audio Interference level (in dBV/m). This level considers the audible amplitude modulation components
in the RF E-field. CW fields without amplitude modulation are assumed to not interfere with the hearing aid
electronics. Modulations without time slots and low fluctuations at low frequencies have low MIF values, TDMA
modulations with narrow transmission and repetition rates of few 100 Hz have high MIF values and give similar
classifications as ANSI C63-2007.
Definitions
ER3D, E-field probes have a bandwidth <10 kHz and can therefore not evaluate the RF envelope in the full audio
band. DASY52 is therefore using the “indirect” measurement method according to ANSI C63.19-2011 which is the
primary method. These near field probes read the averaged E-field measurement. Especially for the new high
peak-to-average (PAR) signal types, the probes shall be linearized by probe modulation response (PMR)
calibration in order to not overestimate the field reading.
The evaluation method or the MIF is defined in ANSI C63.19-2011 section D.7. An RMS demodulated RF signal is
fed to a spectral filter (similar to an A weighting filter) and forwarded to a temporal filter acting as a quasi-peak
detector. The averaged output of these filtering is called to a 1 kHz 80% AM signal as reference. MIF measurement
requires additional instrumentation and is not well suited for evaluation by the end user with reasonable uncertainty
It may alternatively be determined through analysis and simulation, because it is constraint and characteristic for a
communication signal. DASY52 uses well defined signals for PMR calibration. The MIF of these signals has been
determined by simulation and is automatically applied.
MIF values were not tested by a probe or as specified in the standards but are based on analysis provided by
SPEAG for all the air interfaces (GSM, WCDMA, CDMA, LTE). The data included in this report are for the worst
case operating modes. The UIDs used are listed below:
 UID                  Communication System Name                                MIF (dB)
                                                          th
 10295-AAB            CDMA2000 (1xRTT, RC1, SO3, 1/8 Rate 25 fr.)                3.26
 10170-CAB            LTE-FDD (SC-FDMA, 1 RB, 20 MHz, 16QAM)                     -9.76
 10182-CAB            LTE-FDD (SC-FDMA, 1 RB, 15 MHz, 16QAM)                     -9.76
 10176-CAB            LTE-FDD (SC-FDMA, 1 RB, 10 MHz, 16QAM)                     -9.76
 10173-CAB            LTE-TDD (SC-FDMA, 1 RB, 20 MHz, 16QAM)                     -1.44

A PMR calibrated probe is linearized for the selected waveform over the full dynamic range within the uncertainty
specified in its calibration certificate. ER3D, EF3D and EU2D E-field probes have a bandwidth <10 kHz and can
therefore not evaluate the RF envelope in the full audio band. DASY52 is therefore using the \indirect"
measurement method according to ANSI C63.19-2011 which is the primary method. These near field probes read
the averaged E-field measurement. Especially for the new high peak-to-average (PAR) signal types, the probes
shall be linearized by PMR calibration in order to not overestimate the field reading.
The MIF measurement uncertainty is estimated as follows, for modulation frequencies from slotted waveforms with
fundamental frequency and at least 2 harmonics within 10 kHz:
       0.2 dB for MIF -7 to +5 dB,
       0.5 dB for MIF -13 to +11 dB
       1 dB for MIF > -20 dB




                                                   Page 11 of 18
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20232-S3                                                                          Issue Date: 3/30/2015

9. Average Antenna Input Power & Evaluation for Low-power Exemption
An RF air interface technology of a device is exempt from testing when its average antenna input power
plus its MIF is ≤17 dBm for any of its operating modes. If a device supports multiple RF air interfaces,
each RF air interface shall be evaluated individually.

                               Average Antenna                                Input Power
        Air-Interface                                     MIF (dB)                                   HAC Tested
                             Input Power (dBm)1                            plus its MIF (dBm)
CDMA BC0                             24.7                    3.26                 27.96                   Yes
CDMA BC1                             24.7                    3.26                 27.96                   Yes
CDMA BC10                            25.2                    3.26                 28.46                   Yes
LTE Band 2                           23.7                   -9.76                 13.94                   No
LTE Band 4                           23.7                   -9.76                 13.94                   No
LTE Band 5                           23.7                   -9.76                 13.94                   No
LTE Band 12                          24.2                   -9.76                 14.44                   No
LTE Band 25                          23.7                   -9.76                 13.94                   No
LTE Band 26                          23.7                   -9.76                 13.94                   No
LTE Band 41                          23.7                   -1.44                 22.26                   Yes

Note(s):
1. Max tune-up limit

Conclusions
RF Emission testing for this device is required for CDMA voice mode and LTE Band 41 only




                                                   Page 12 of 18
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20232-S3                                                                            Issue Date: 3/30/2015


10.      HAC RF Emissions Test Procedure
The following are step-by-step test procedures.
a) Confirm proper operation of the field probe, probe measurement system and other instrumentation and the
   positioning system.
b) Position the WD in its intended test position.
c) Set the WD to transmit a fixed and repeatable combination of signal power and modulation characteristic that is
   representative of the worst case (highest interference potential) encountered in normal use. Transiently
   occurring start-up, changeover, or termination conditions, or other operations likely to occur less than 1% of the
   time during normal operation, may be excluded from consideration.
d) The center sub-grid shall be centered on the T-Coil mode perpendicular measurement point or the acoustic
   output, as appropriate. Locate the field probe at the initial test position in the 50 mm by 50 mm grid, which is
   contained in the measurement plane, refer to illustrated in Figure 1. If the field alignment method is used, align
   the probe for maximum field reception.
e) Record the reading at the output of the measurement system
f)   Scan the entire 50 mm by 50 mm region in equally spaced increments and record the reading at each
     measurement point. The distance between measurement points shall be sufficient to assure the identification of
     the maximum reading.
g) Identify the five contiguous sub-grids around the center sub-grid whose maximum reading is the lowest of all
   available choices. This eliminates the three sub-grids with the maximum readings. Thus, the six areas to be
   used to determine the WD’s highest emissions are identified.
h) Identify the maximum reading within the non-excluded sub-grids identified in step g).
i)   Convert the highest field reading within identified in step h) to RF audio interference level, in V/m, by taking the
     square root of the reading and then dividing it by the measurement system transfer function, established in
     5.5.1.1 Convert this result to dB(V/m) by taking the base-10 logarithm and multiplying by 20.
     Indirect measurement method
     Replacing step i), the RF audio interference level in dB (V/m) is obtained by adding the MIF (in dB) to the
     maximum steady-state rms field-strength reading, in dB (V/m), from step h). Use this result to determine the
     category rating
j)   Compare this RF audio interference level with the categories in Clause 8 (ANSI C63.19-2011) and record the
     resulting WD category rating
k) For the T-Coil mode M-rating assessment, determine whether the chosen perpendicular measurement point is
   contained in an included sub-grid of the first scan. If so, then a second scan is not necessary. The first scan
   and resultant category rating may be used for the T-Coil mode M rating.
     Otherwise, repeat step a) through step i), with the grid shifted so that it is centered on the perpendicular
     measurement point. Record the WD category rating.




                                                   Page 13 of 18
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20232-S3                                                                          Issue Date: 3/30/2015




                      Figure 1 - WD reference and plane for RF emission measurements




                                                   Page 14 of 18
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20232-S3                                                                          Issue Date: 3/30/2015

Test flowchart Per ANSI-PC63.19 2011

                                                Test Instructions

                                    • Confirm proper operation of probes and
                                      instrumentation
                                    • Position WD
                                    • Configure WD Tx Operation

                                                    (Step a-c)



                                    • Initialize field probe and take first reading
                                    • Scan Area
                                                     (Step d-f)




                                    • Identify exclusion area
                                    • Rescan or reanalyze open area
                                      todetermine maximum
                                    • Indirect method: Add the MIF to the
                                      maximum steady state rms field strength
                                      and record RF Audio Interference Level,
                                      in dB (V/m)

                                                      (Step g-i)




                                              Identify & Record Category

                                                       (Step j)




                                                   Page 15 of 18
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20232-S3                                                                                     Issue Date: 3/30/2015


11.        RF Emissions Measurement Criteria
WD RF audio interference level caterories in logarithmic units
                                                                             E-field emissions
       Emission Categories
                                                        < 960 MHz                                      > 960 MHz
            Category M1                            50 to 55 dB (V/m)                                40 to 45 dB (V/m)
            Category M2                            45 to 50 dB (V/m)                                35 to 40 dB (V/m)
            Category M3                            40 to 45 dB (V/m)                                30 to 35 dB (V/m)
            Category M4                               <40 dB (V/m)                                    <30 dB (V/m)

12.        HAC (RF Emissions) Test Results
MIF values were not tested by a probe or as specified in the standards but are based on analysis provided by
SPEAG for the following User Identifiers and air interfaces.
The data included in this report are for the worst case operating modes. Refer to Appendix D and G for the MIF
vales that represent the worst case operation modes.
                                                                                 Results*                             Plots
           Air-Interface              Ch. No.            Freq. (MHz)                                M-Rating
                                                                                 (dB V/m)                            Page #
                                        1013                 824.70                31.94               M4               1
           CDMA2000
                                         384                 836.60                30.84               M4               2
             BC0
                                         777                 848.31                30.32               M4               3
                                          25                1851.25                25.48               M4               4
           CDMA2000
                                         600                1880.00                26.00               M4               5
             BC1
                                        1175                1908.75                26.52               M4               6
                                         476                 817.90                32.63               M4               7
           CDMA2000
                                         580                 820.50                30.28               M4               8
             BC10
                                         684                 823.10                12.82               M4               9
                                       39750                2506.00                23.75               M4              10
               LTE                     40185                2549.50                20.96               M4              11
                                       40620                2593.00                22.84               M4              12
             Band 41
                                       41055                2636.50                21.56               M4              13
                                       41490                2680.00                20.48               M4              14
                                   Refer to Section 9 Evaluation for Low-power Exemption. RF
                                 Emission testing for this device is required only for CDMA voice
              LTE
                                   modes and LTE-TDD. All other applicable air-interfaces are          M4               N/A
      Bands 2/4/5/12/25/26       exempt from testing in accordance with C63.19-2011 Clause 4.4
                                                         and are rated M4.


Note(s):
*: Measured Audio Interference level in dB (V/m): indirect method (max rms field strength Plus MIF)
**: According to the last paragraph of Section 8, the MIF measurement uncertainty is estimated to be 0.2 dB for MIF -7 to + 5 dB.
The maximum E-field result of 25.79 dB V/m plus measurement uncertainty of 0.2 dB is 25.99 dB V/m, which is still within a M4
rating.




                                                   Page 16 of 18
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20232-S3                                                                          Issue Date: 3/30/2015

12.1. Worst Case RF Emission Test Plot
Test Laboratory: UL Verification Services Inc., SAR Lab 2                                Date: 3/9/2015


HAC-RFE CDMA BC1

Communication System: UID 10295 - AAA, CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 1880 MHz; Duty Cycle:
1:17.7419
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2540; ConvF(1, 1, 1); Calibrated: 8/26/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1259; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)


CDMA BC1 E-Field measurement/RC1_SO3_Ch 600/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 11.59 V/m; Power Drift = 0.84 dB
Applied MIF = 3.26 dB
RF audio interference level = 26.00 dBV/m
Emission category: M4

                                     MIF scaled E-field
                                     Grid 1 M4         Grid 2 M4     Grid 3 M4
                                     25.8 dBV/m        25.49 dBV/m   23.91 dBV/m
                                     Grid 4 M4         Grid 5 M4     Grid 6 M4
                                     22.12 dBV/m       25.79 dBV/m   26 dBV/m
                                     Grid 7 M4         Grid 8 M4     Grid 9 M4
                                     26.27 dBV/m       28.12 dBV/m   28.05 dBV/m




                       0 dB = 25.46 V/m = 28.12 dBV/m


                                                   Page 17 of 18
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20232-S3                                                                          Issue Date: 3/30/2015


Appendixes
Refer to separated files for the following appendixes

A_15I20232v0 Setup Photo

B_15I20232v0 System Validation Plots

C_15I20232v0 RF Emissions Test Plots

D_15I20232v0 MIF Attestation Letter

E_15I20232v0 Probe Cal. Certificates

F_15I20232v0 Dipole Cal. Certificates

G_15I20232v0 UID Specification



                                                 END OF REPORT




                                                   Page 18 of 18
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.



Document Created: 2015-03-30 21:05:30
Document Modified: 2015-03-30 21:05:30

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC