HAC RF Test report3

FCC ID: ZNFLS660

Test Report

Download: PDF
FCCID_2381695

Test Laboratory: UL Verification Services Inc., SAR Lab 2                               Date: 8/20/2014

HAC-RF Emission
Communication System: UID 10295 - AAB, CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 824.7 MHz; Duty Cycle:
1:17.7419
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2339; ConvF(1, 1, 1); Calibrated: 2/14/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1359; Calibrated: 2/17/2014
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

CDMA BC0 E-Field measurement/RC1_SO3_Ch 1013/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 26.18 V/m; Power Drift = -0.30 dB
Applied MIF = 3.26 dB
RF audio interference level = 29.31 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                     Grid 1 M4         Grid 2 M4     Grid 3 M4
                                     28.27 dBV/m       28.82 dBV/m   28.39 dBV/m
                                     Grid 4 M4         Grid 5 M4     Grid 6 M4
                                     28.96 dBV/m       29.31 dBV/m   29 dBV/m
                                     Grid 7 M4         Grid 8 M4     Grid 9 M4
                                     29.28 dBV/m       29.78 dBV/m   29 dBV/m




                      0 dB = 30.84 V/m = 29.78 dBV/m


Test Laboratory: UL Verification Services Inc., SAR Lab 2                               Date: 8/20/2014

HAC-RF Emission
Communication System: UID 10295 - AAB, CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 831.99 MHz; Duty Cycle:
1:17.7419
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2339; ConvF(1, 1, 1); Calibrated: 2/14/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1359; Calibrated: 2/17/2014
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

CDMA BC0 E-Field measurement/RC1_SO3_Ch 384/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 36.57 V/m; Power Drift = -1.19 dB
Applied MIF = 3.26 dB
RF audio interference level = 31.51 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                     Grid 1 M4         Grid 2 M4     Grid 3 M4
                                     30.29 dBV/m       30.93 dBV/m   29.92 dBV/m
                                     Grid 4 M4         Grid 5 M4     Grid 6 M4
                                     30.83 dBV/m       31.51 dBV/m   31.26 dBV/m
                                     Grid 7 M4         Grid 8 M4     Grid 9 M4
                                     31.1 dBV/m        31.69 dBV/m   31.33 dBV/m




                      0 dB = 38.42 V/m = 31.69 dBV/m


Test Laboratory: UL Verification Services Inc., SAR Lab 2                               Date: 8/20/2014

HAC-RF Emission
Communication System: UID 10295 - AAB, CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 848.31 MHz; Duty Cycle:
1:17.7419
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2339; ConvF(1, 1, 1); Calibrated: 2/14/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1359; Calibrated: 2/17/2014
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

CDMA BC0 E-Field measurement/RC1_SO3_Ch 777/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 26.01 V/m; Power Drift = -0.23 dB
Applied MIF = 3.26 dB
RF audio interference level = 29.23 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                     Grid 1 M4         Grid 2 M4     Grid 3 M4
                                     28.59 dBV/m       28.96 dBV/m   28.51 dBV/m
                                     Grid 4 M4         Grid 5 M4     Grid 6 M4
                                     28.83 dBV/m       29.23 dBV/m   28.8 dBV/m
                                     Grid 7 M4         Grid 8 M4     Grid 9 M4
                                     28.72 dBV/m       29.28 dBV/m   28.81 dBV/m




                      0 dB = 29.09 V/m = 29.27 dBV/m


Test Laboratory: UL Verification Services Inc., SAR Lab 2                               Date: 8/20/2014

HAC-RF Emission
Communication System: UID 10295 - AAA, CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 1851.25 MHz; Duty Cycle:
1:17.7419
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2339; ConvF(1, 1, 1); Calibrated: 2/14/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1359; Calibrated: 2/17/2014
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

CDMA BC1 E-Field measurement/RC1_SO3_Ch 25/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 6.180 V/m; Power Drift = 0.07 dB
Applied MIF = 3.26 dB
RF audio interference level = 24.51 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                     Grid 1 M4         Grid 2 M4     Grid 3 M4
                                     23.97 dBV/m       25.1 dBV/m    24.71 dBV/m
                                     Grid 4 M4         Grid 5 M4     Grid 6 M4
                                     19.79 dBV/m       21.63 dBV/m   21.63 dBV/m
                                     Grid 7 M4         Grid 8 M4     Grid 9 M4
                                     24.51 dBV/m       24.04 dBV/m   21.52 dBV/m




                      0 dB = 17.98 V/m = 25.10 dBV/m


Test Laboratory: UL Verification Services Inc., SAR Lab 2                              Date: 8/20/2014

HAC-RF Emission
Communication System: UID 10295 - AAA, CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 1880 MHz; Duty Cycle:
1:17.7419
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2339; ConvF(1, 1, 1); Calibrated: 2/14/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1359; Calibrated: 2/17/2014
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

CDMA BC1 E-Field measurement/RC1_SO3_Ch 600/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 8.290 V/m; Power Drift = -0.04 dB
Applied MIF = 3.26 dB
RF audio interference level = 23.09 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                     Grid 1 M4         Grid 2 M4     Grid 3 M4
                                     21.65 dBV/m       23.09 dBV/m   22.95 dBV/m
                                     Grid 4 M4         Grid 5 M4     Grid 6 M4
                                     22.04 dBV/m       22.34 dBV/m   21.73 dBV/m
                                     Grid 7 M4         Grid 8 M4     Grid 9 M4
                                     25.54 dBV/m       25.62 dBV/m   24 dBV/m




                      0 dB = 19.10 V/m = 25.62 dBV/m


Test Laboratory: UL Verification Services Inc., SAR Lab 2                              Date: 8/20/2014

HAC-RF Emission
Communication System: UID 10295 - AAA, CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 1908.75 MHz; Duty Cycle:
1:17.7419
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2339; ConvF(1, 1, 1); Calibrated: 2/14/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1359; Calibrated: 2/17/2014
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

CDMA BC1 E-Field measurement/RC1_SO3_Ch 1175/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 9.137 V/m; Power Drift = 0.13 dB
Applied MIF = 3.26 dB
RF audio interference level = 23.34 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                     Grid 1 M4         Grid 2 M4     Grid 3 M4
                                     21.32 dBV/m       23.34 dBV/m   23.28 dBV/m
                                     Grid 4 M4         Grid 5 M4     Grid 6 M4
                                     21.39 dBV/m       22.39 dBV/m   22.39 dBV/m
                                     Grid 7 M4         Grid 8 M4     Grid 9 M4
                                     25.68 dBV/m       25.17 dBV/m   23.35 dBV/m




                      0 dB = 19.23 V/m = 25.68 dBV/m



Document Created: 2014-08-22 09:55:46
Document Modified: 2014-08-22 09:55:46

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC