HAC RF Test report2

FCC ID: ZNFLS660

Test Report

Download: PDF
FCCID_2381694

Test Laboratory: UL Verification Services Inc., SAR Lab 2                           Date: 8/20/2014

HAC-RF Emission
Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2339; ConvF(1, 1, 1); Calibrated: 2/14/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1359; Calibrated: 2/17/2014
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

Dipole E-Field measurement/835 MHz/Hearing Aid Compatibility Test at 15mm distance
(41x361x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 121.4 V/m; Power Drift = 0.06 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 110.0 V/m
Near-field category: M4 (AWF 0 dB)

                                          PMF scaled E-field
                                          Grid 1 M4 Grid 2 M4 Grid 3 M4
                                          106.8 V/m         110.0 V/m   108.7 V/m
                                          Grid 4 M4         Grid 5 M4   Grid 6 M4
                                          61.19 V/m         64.81 V/m   64.81 V/m
                                          Grid 7 M4         Grid 8 M4   Grid 9 M4
                                          102.7 V/m         108.1 V/m   108.1 V/m




                      0 dB = 110.0 V/m = 40.83 dBV/m


Test Laboratory: UL Verification Services Inc., SAR Lab 2                           Date: 8/20/2014

HAC-RF Emission
Communication System: UID 0, CW; Frequency: 1880 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2339; ConvF(1, 1, 1); Calibrated: 2/14/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1359; Calibrated: 2/17/2014
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

Dipole E-Field measurement/1880 MHz/Hearing Aid Compatibility Test at 15mm
distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 139.8 V/m; Power Drift = -0.04 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 89.65 V/m
Near-field category: M3 (AWF 0 dB)

                                          PMF scaled E-field
                                          Grid 1 M3 Grid 2 M3 Grid 3 M3
                                          84.24 V/m         85.82 V/m   84.58 V/m
                                          Grid 4 M3         Grid 5 M3   Grid 6 M3
                                          68.24 V/m         70.30 V/m   70.22 V/m
                                          Grid 7 M3         Grid 8 M3   Grid 9 M3
                                          87.47 V/m         89.65 V/m   89.44 V/m




                      0 dB = 89.65 V/m = 39.05 dBV/m



Document Created: 2014-08-22 01:57:14
Document Modified: 2014-08-22 01:57:14

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC