Test Report

FCC ID: ZNFLGL25

Test Report

Download: PDF
FCCID_2446716



 Report Number : F690501/RF-RTL008133                                                     Page: 2            of       20



                                                  INDEX
                                         TABLE OF CONTENTS                                                         Page


   1. General Information -------------------------------------------------------------------------------             3


   2. AC Power Line Conducted Emissions --------------------------------------------------------                      6


   3. Radiated Emissions -------------------------------------------------------------------------------             11


   4. Frequency Stability --------------------------------------------------------------------------------           16


   5. 20 ㏈ Bandwidth ----------------------------------------------------------------------------------              19




The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, except in full, without prior written permission of the Company.
SGS Korea Co., Ltd. (Gunpo Laboratory)     4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 435-040   http://www.sgsgroup.kr
RTT5041-20(2014.01.20)(2)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370             A4(210 mmⅹ297 mm)


 Report Number : F690501/RF-RTL008133                                                   Page: 3            of       20


1. General Information
1.1. Testing Laboratory
SGS Korea Co., Ltd. (Gunpo Laboratory)
     - Wireless Div. 2FL, 10-2, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 435-837
All SGS services are rendered in accordance with the applicable SGS conditions of service available on
request and accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx.
Phone No.          : + 82 31 688 0901
Fax No.            : + 82 31 688 0921
1.2. Details of Applicant
Applicant          : LG Electronics MobileComm U.S.A., Inc.
Address            : 10101 Old Grove Road, San Diego, CA 92131
Contact Person     : An, Hee-Ju
Phone No.          : +82 2 2033 1103
1.3. Description of EUT

 Kind of Product              Cellular/PCS GSM/GPRS/EDGE/WCDMA/HSDPA/HSUPA Smart Phone

 Model Name                   LGL25

 Power Supply                 DC 3.8 V

 Frequency Range              13.56 ㎒ (NFC)

 Modulation Technique         ASK

 Number of Channels           1 channel (NFC)

 Antenna Type                 Internal type (SISO)




The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, except in full, without prior written permission of the Company.
SGS Korea Co., Ltd. (Gunpo Laboratory)   4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 435-040   http://www.sgsgroup.kr
RTT5041-20(2014.01.20)(2)                      Tel. +82 31 428 5700 / Fax. +82 31 427 2370             A4(210 mmⅹ297 mm)


 Report Number : F690501/RF-RTL008133                                                      Page: 4              of        20


1.4. Test Equipment List

                                                                                                             Cal.
    Equipment           Manufacturer                Model                    S/N             Cal. Date                  Cal. Due
                                                                                                           Interval

  Signal Generator            Agilent              E8257D               MY51501169         Jul. 17, 2014   Annual     Jul. 17, 2015

 Spectrum Analyzer            Agilent              N9030A               MY53120526         Jul. 17, 2014   Annual     Jul. 17, 2015

 Spectrum Analyzer             R&S                  FSV30                  100768         Mar. 27, 2014 Annual Mar. 27, 2015

  High Pass Filter          Mini circuits          NHP-25+              V9741901107       Mar. 21, 2014 Annual Mar. 21, 2015


     Attenuator                MCLI               FAS-12-10                   1            Jun. 20, 2014   Annual     Jun. 20, 2015

  DC Power Supply             Agilent              U8002A               MY49030063        Dec. 12, 2013 Annual Dec. 12, 2014

Temperature Chamber     ESPEC CORP.                 PL-1J                 15000793         Jun. 25, 2014   Annual     Jun. 25, 2015

    Preamplifier                H.P.                8447F               2944A03909        Aug. 27, 2014 Annual Aug. 27, 2015

                       SCHWARZBECK
   Bilog Antenna                                  VULB9163                   396           Jun. 07, 2013 Biennial Jun. 07, 2015
                      MESSELEKTRONIK
                       SCHWARZBECK
   Loop Antenna                                  FMZB 1519                1519-039         Jul. 09, 2013   Biennial Jul. 09, 2015
                      MESSELEKTRONIK

   Test Receiver               R&S                  ESU26                  100109         Mar. 04, 2014 Annual Mar. 04, 2015

   Test Receiver               R&S                  ESCI 7                 100911          Jan. 24, 2014   Annual     Jan. 24, 2015


  Antenna Master              INN-CO               MM4000                    N/A                N/A          N/A         N.C.R.

    Turn Table                INN-CO              DS 1200 S                  N/A                N/A          N/A         N.C.R.

                                                   L×W×H
 Anechoic Chamber      SY Corporation                                        N/A                N/A          N/A         N.C.R.
                                            (9.6 m × 6.4 m × 6.6 m)

Two-Line V-Network             R&S                 ENV216                  100190          Jan. 02, 2014   Annual     Jan. 02, 2015

                                                   L×W×H
    Shield Room        SY Corporation                                        N/A              N.C.R.         N/A         N.C.R.
                                            (6.5 m × 3.5 m × 3.5 m)




The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, except in full, without prior written permission of the Company.
SGS Korea Co., Ltd. (Gunpo Laboratory)      4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 435-040    http://www.sgsgroup.kr
RTT5041-20(2014.01.20)(2)                         Tel. +82 31 428 5700 / Fax. +82 31 427 2370               A4(210 mmⅹ297 mm)


 Report Number : F690501/RF-RTL008133                                                   Page: 5              of       20


1.5. Summary of Test Results
The EUT has been tested according to the following specifications:

                                Applied standard : FCC Part15 subpart C

 Standard section                                 Test item                                                 Result

         15.207                   AC Power Line Conducted Emissions                                       Complied
 15.225(a)(b)(c)(d)
                                            Radiated emissions                                            Complied
      15.209
      15.225(e)                             Frequency Stability                                           Complied

      15.215(c)                              20 ㏈ Bandwidth                                                       -

1.6. Sample calculation
Where relevant, the following sample calculation is provided:

1.6.1. Conducted test
Offset value (㏈) = Attenuator (㏈) + Cable loss (㏈)

1.6.2. Radiation test
Field strength level (㏈㎶/m) = Measured level (㏈㎶) + Antenna factor (㏈) + Cable loss (㏈) - amplifier (㏈)

1.7. Test report revision

 Revision            Report number             Date of Issue                              Description

     0            F690501/RF-RTL008133           2014.10.31                                    Initial




The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, except in full, without prior written permission of the Company.
SGS Korea Co., Ltd. (Gunpo Laboratory)   4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 435-040     http://www.sgsgroup.kr
RTT5041-20(2014.01.20)(2)                      Tel. +82 31 428 5700 / Fax. +82 31 427 2370               A4(210 mmⅹ297 mm)


 Report Number : F690501/RF-RTL008133                                                       Page: 6                 of        20


2. AC power line conducted emissions
2.1. Test Setup

    Shield room enclosure                                                                  Main power source
                                                                                                      0.4 m
                                                  LISN
                                                (ENV216)


                                                   AC
                                                 Adaptor


                            Table height
                            0.8 m
                                                   EUT
 to Test Receiver




2.1.1. Actual equipment used for AC power line conducted emission
                                                                                                             Cal.
   Equipment          Manufacturer                 Model                  S/N             Cal. Date                        Cal. Due
                                                                                                           Interval

 Signal Generator           Agilent               E8257D              MY51501169        Jul. 17, 2014      Annual        Jul. 17, 2015

  Test Receiver              R&S                   ESCI 7                100911         Jan. 24, 2014      Annual        Jan. 24, 2015

Two-Line V-Network           R&S                  ENV216                 100190         Jan. 02, 2014      Annual        Jan. 02, 2015

                                                  L×W×H
   Shield Room        SY Corporation                                      N/A              N.C.R.            N/A            N.C.R.
                                           (6.5 m × 3.5 m × 3.5 m)




The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, except in full, without prior written permission of the Company.
SGS Korea Co., Ltd. (Gunpo Laboratory)       4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 435-040      http://www.sgsgroup.kr
RTT5041-20(2014.01.20)(2)                          Tel. +82 31 428 5700 / Fax. +82 31 427 2370                A4(210 mmⅹ297 mm)


 Report Number : F690501/RF-RTL008133                                                   Page: 7               of      20


2.2. Limit

According to §15.207(a) for an intentional radiator that is designed to be connected to the public utility (AC)
power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency or
frequencies, within the band 150 ㎑ to 30 ㎒, shall not exceed the limits in the following table, as measured
using a 50 uH/50 ohm line impedance stabilization network(LISN).
Compliance with the provision of this paragraph shall on the measurement of the radio frequency voltage
between each power line and ground at the power terminal. The lower applies at the boundary between the
frequency ranges.


                                                                    Conducted limit (㏈㎶)
   Frequency of Emission (㎒)
                                                    Quasi-peak                                         Average

             0.15 – 0.50                               66 - 56*                                        56 - 46*

             0.50 – 5.00                                  56                                             46

             5.00 – 30.0                                  60                                             50
  * Decreases with the logarithm of the frequency.

2.3. Test Procedures

All modes were investigated for this test. The full data for the worst case data rate are reported in this section.
AC power line conducted emissions from the EUT were measured according to the dictates of ANSI
C63.4-2003


1. The test procedure is performed in a 6.5 m × 3.5 m× 3.5 m (L × W × H) shielded room. The EUT along with
  its peripherals were placed on a 1.0 m(W)× 1.5 m(L) and 0.8 m in height wooden table and the EUT was
  adjusted to maintain a 0.4 meter space from a vertical reference plane.
2. The EUT was connected to power mains through a line impedance stabilization network (LISN) which
  provides 50 ohm coupling impedance for measuring instrument and the chassis ground was bounded to the
  horizontal ground plane of shielded room.
3. The excess power cable between the EUT and the LISN was bundled. All connecting cables of EUT were
  moved to find the maximum emission.




The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, except in full, without prior written permission of the Company.
SGS Korea Co., Ltd. (Gunpo Laboratory)   4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 435-040     http://www.sgsgroup.kr
RTT5041-20(2014.01.20)(2)                      Tel. +82 31 428 5700 / Fax. +82 31 427 2370               A4(210 mmⅹ297 mm)


     Report Number : F690501/RF-RTL008133                                                      Page: 8             of       20


2.4. Test Results

Ambient temperature               : (23 ± 1) ℃
Relative humidity                 : 47 % R.H.

The following table shows the highest levels of conducted emissions on both phase of Hot and
Neutral line.

Frequency range                   :    0.15 ㎒ – 30 ㎒
Measured Bandwidth                :    9 ㎑


     FREQ.              LEVEL(㏈㎶)                                        LIMIT(㏈㎶)                            MARGIN(㏈)
                                                     LINE
      (㎒)        Quasi Peak           Average                   Quasi Peak          Average         Quasi Peak          Average

      1.25           36.20             32.90           H            56.00             46.00             19.80             13.10

      2.00           41.70             31.20           H            56.00             46.00             14.30             14.80

      3.11           41.20             27.60           H            56.00             46.00             14.80             18.40

      6.38           38.00             25.40           H            60.00             50.00             22.00             24.60

      11.66          40.80             29.70           H            60.00             50.00             19.20             20.30

      18.41          40.60             22.60           H            60.00             50.00             19.40             27.40

      1.12           34.60             27.10           N            56.00             46.00             21.40             18.90

      2.02           37.90             28.90           N            56.00             46.00             18.10             17.10

      3.49           32.60             24.90           N            56.00             46.00             23.40             21.10

      6.45           32.80             22.70           N            60.00             50.00             27.20             27.30

      13.11          38.33             27.10           N            60.00             50.00             21.67             22.90

      18.37          43.50             24.70           N            60.00             50.00             16.50             25.30


Note ;
1.      Line ( H ): Hot, Line ( N ): Neutral
2.      All modes of operation were investigated and the worst-case emissions are reported.
3.      The limit for Class B device(s) from 150 ㎑ to 30 ㎒ are specified in Section of the Title 47 CFR.
4.      Traces shown in plot made using a peak detector and average detector.
5.      Deviations to the Specifications: None.




The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, except in full, without prior written permission of the Company.
SGS Korea Co., Ltd. (Gunpo Laboratory)          4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 435-040    http://www.sgsgroup.kr
RTT5041-20(2014.01.20)(2)                             Tel. +82 31 428 5700 / Fax. +82 31 427 2370               A4(210 mmⅹ297 mm)


 Report Number : F690501/RF-RTL008133                                                    Page: 9              of     20


Plots of Conducted Power line

Test mode : (Hot)




               90

               85

               80

               75

               70

               65

               60

               55

           Level50in dB ㎶


               45

               40

               35

               30

               25

               20

               15

               10

                5

                0
                150k        300 400 500    800 1M            2M     3M    4M 5M 6       8 10M           20M    30M
                                                       Frequency in Hz




The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, except in full, without prior written permission of the Company.
SGS Korea Co., Ltd. (Gunpo Laboratory)    4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 435-040   http://www.sgsgroup.kr
RTT5041-20(2014.01.20)(2)                       Tel. +82 31 428 5700 / Fax. +82 31 427 2370              A4(210 mmⅹ297 mm)


 Report Number : F690501/RF-RTL008133                                                    Page: 10             of       20


Test mode : (Neutral)




               90

               85

               80

               75

               70

               65

               60

               55

           Level50in dB ㎶


               45

               40

               35

               30

               25

               20

               15

               10

                5

                0
                150k        300 400 500    800 1M            2M     3M    4M 5M 6       8 10M           20M   30M
                                                       Frequency in Hz




The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, except in full, without prior written permission of the Company.
SGS Korea Co., Ltd. (Gunpo Laboratory)    4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 435-040   http://www.sgsgroup.kr
RTT5041-20(2014.01.20)(2)                       Tel. +82 31 428 5700 / Fax. +82 31 427 2370              A4(210 mmⅹ297 mm)


 Report Number : F690501/RF-RTL008133                                                   Page: 11             of       20


3. Radiated Emissions
3.1. Test Setup

The diagram below shows the test setup that is utilized to make the measurements for emission
from 9 ㎑ to 30 ㎒ Emissions.




The diagram below shows the test setup that is utilized to make the measurements for
emission .The spurious emissions were investigated form 1 ㎓ to the 10th harmonic of the highest
fundamental frequency or 40 ㎓, whichever is lower.




The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, except in full, without prior written permission of the Company.
SGS Korea Co., Ltd. (Gunpo Laboratory)   4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 435-040   http://www.sgsgroup.kr
RTT5041-20(2014.01.20)(2)                      Tel. +82 31 428 5700 / Fax. +82 31 427 2370             A4(210 mmⅹ297 mm)


 Report Number : F690501/RF-RTL008133                                                     Page: 12                  of        20


3.1.1. Actual equipment used for Radiated Emissions
                                                                                                           Cal.
    Equipment          Manufacturer              Model                  S/N             Cal. Date                        Cal. Due
                                                                                                         Interval

 Signal Generator           Agilent             E8257D              MY51501169        Jul. 17, 2014      Annual      Jul. 17, 2015

 Spectrum Analyzer          Agilent             N9030A              MY53120526        Jul. 17, 2014      Annual      Jul. 17, 2015

   Test Receiver             R&S                 ESU26                 100109        Mar. 04, 2014       Annual     Mar. 04, 2015

  High Pass Filter      Mini circuits           NHP-25+            V9741901107       Mar. 21, 2014       Annual     Mar. 21, 2015

    Preamplifier             H.P.                8447F              2944A03909       Aug. 27, 2014       Annual     Aug. 27, 2015

                      SCHWARZBECK
   Bilog Antenna                               VULB9163                 396           Jun. 07, 2013      Biennial    Jun. 07, 2015
                     MESSELEKTRONIK
                      SCHWARZBECK
   Loop Antenna                               FMZB 1519               1519-039        Jul. 09, 2013      Biennial    Jul. 09, 2015
                     MESSELEKTRONIK

  Antenna Master            INN-CO              MM4000                  N/A                N/A             N/A            N.C.R.

    Turn Table              INN-CO             DS 1200 S                N/A                N/A             N/A            N.C.R.

                                                L×W×H
Anechoic Chamber      SY Corporation                                    N/A                N/A             N/A            N.C.R.
                                         (9.6 m × 6.4 m × 6.6 m)


3.1.2. Definition of DUT Axis.
- Definition of DUT three orthogonal planes were described in the test setup photo.




The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, except in full, without prior written permission of the Company.
SGS Korea Co., Ltd. (Gunpo Laboratory)     4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 435-040      http://www.sgsgroup.kr
RTT5041-20(2014.01.20)(2)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370                A4(210 mmⅹ297 mm)


 Report Number : F690501/RF-RTL008133                                                   Page: 13             of       20


3.2. Limit

According to §15.225,
(a) The field strength of any emissions within the band 13.553 – 13.567 ㎒ shall not exceed 15 848
    microvolts / meter at 30 meters.
(b) Within the bands 13.410 – 13.553 ㎒ and 13.567 – 13.710 ㎒, the field strength of any
    emissions shall not exceed 334 microvolts / meter at 30 meters.
(c) Within the bands 13.110 – 13.410 ㎒ and 13.710 – 14.010 ㎒ the field strength of any
    emissions shall not exceed 106 microvolts / meter at 30 meters.
(d) The field strength of any emissions appearing outside of the 13.110 – 14.010 ㎒ and shall not
    exceed the general radiated emission limits in §15.209.

3.3. Test Procedures

Radiated emissions from the EUT were measured according to the dictates of ANSI C63.4-2003

a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter
  anechoic chamber test site. The table was rotated 360 degrees to determine the position of the
  highest radiation.

b. Then antenna is a loop antenna is fixed at one meter above the ground to determine the
  maximum value of the field strength. Both parallel and perpendicular of the antenna are set to
  make the measurement.

c. For each suspected emission, the EUT was arranged to its worst case and then the table was
   turned from 0 degrees to 360 degrees to find the maximum reading.

d. The test-receiver system was set to Quasi peak Detect Function with Maximum Hold Mode.

e. To get a maximum emission level from the EUT, the EUT is manipulated through three orthogonal
   planes.


NOTE;

All modes were investigated for radiated spurious emissions. Only the radiated emissions of the
configuration that produced the worst case emissions are reported in this section.

Worst orthogonal plan of EUT is Z – axis during radiation test.




The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, except in full, without prior written permission of the Company.
SGS Korea Co., Ltd. (Gunpo Laboratory)   4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 435-040   http://www.sgsgroup.kr
RTT5041-20(2014.01.20)(2)                      Tel. +82 31 428 5700 / Fax. +82 31 427 2370             A4(210 mmⅹ297 mm)


 Report Number : F690501/RF-RTL008133                                                     Page: 14             of       20


3.4. Test Result

Ambient temperature           : (23 ± 1) ℃
Relative humidity             : 47   % R.H.

The following table shows the highest levels of radiated emissions.

-Fundamental within the band 13.553 – 13.567 ㎒

                                                    Correction
      Radiated Emissions                 Ant                                        Total                    FCC Limit
                                                     Factors

                                                  Ant.       Cable         Actual          Actual          Limit
 Freq.     Reading          Detect                                                                                     Margin
                                         Pol.    Factor      loss         (㏈㎶/m)          (㏈㎶/m)         (㏈㎶/m)
  (㎒)       (㏈㎶)            Mode                                                                                        (㏈)
                                                 (㏈/m)        (㏈)          at 3 m          at 30 m        at 30 m

13.559      26.10       Quasi-Peak        H      20.12        0.49          46.71            6.71         84.00         77.29


-Spurious emission within the bands 13.410 – 13.553 ㎒ and 13.567 -13.710 ㎒

                                                    Correction
      Radiated Emissions                 Ant.                                       Total                    FCC Limit
                                                     Factors

                                                  Ant.       Cable         Actual          Actual          Limit
 Freq.     Reading          Detect                                                                                     Margin
                                         Pol.    Factor      loss         (㏈㎶/m)          (㏈㎶/m)         (㏈㎶/m)
  (㎒)       (㏈㎶)            Mode                                                                                        (㏈)
                                                 (㏈/m)        (㏈)          at 3 m          at 30 m        at 30 m

13.553      14.90      Quasi-Peak         H      20.12        0.49          35.51           -4.49         50.47         54.96

13.567       9.60      Quasi-Peak         H      20.12        0.49          30.21           -9.79         50.47         60.26


- Spurious emission within the bands 13.110 – 13.410 ㎒ and 13.710 – 14.010 ㎒

                                                    Correction
      Radiated Emissions                 Ant.                                       Total                    FCC Limit
                                                     Factors

                                                  Ant.       Cable         Actual          Actual          Limit
 Freq.     Reading          Detect                                                                                     Margin
                                         Pol.    Factor      loss         (㏈㎶/m)          (㏈㎶/m)         (㏈㎶/m)
  (㎒)       (㏈㎶)            Mode                                                                                        (㏈)
                                                 (㏈/m)        (㏈)          at 3 m          at 30 m        at 30 m

13.343       6.90      Quasi-Peak         H      20.11        0.48          27.49           -12.51        40.51         53.02

13.772       9.90      Quasi-Peak         H      20.12        0.49          30.51           -9.49         40.51         50.00




The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, except in full, without prior written permission of the Company.
SGS Korea Co., Ltd. (Gunpo Laboratory)     4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 435-040   http://www.sgsgroup.kr
RTT5041-20(2014.01.20)(2)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370             A4(210 mmⅹ297 mm)


 Report Number : F690501/RF-RTL008133                                                     Page: 15                of      20


- Spurious emission below 30 ㎒ except for 13.110 – 14.010 ㎒
                                                    Correction
         Radiated Emissions              Ant.                                       Total                        FCC Limit
                                                     Factors

                                                  Ant.       Cable         Actual          Actual            Limit
 Freq.      Reading         Detect                                                                                       Margin
                                         Pol.    Factor      loss         (㏈㎶/m)          (㏈㎶/m)           (㏈㎶/m)
  (㎒)        (㏈㎶)           Mode                                                                                          (㏈)
                                                 (㏈/m)        (㏈)          at 3 m         at 300 m         at 300 m

 0.013        -5.50         Average       H      20.40        0.05          14.95           -65.05          45.33        110.38

 0.171       12.20          Average       H      19.99        0.08          32.27           -47.73          22.94         70.67



                                                    Correction
         Radiated Emissions              Ant.                                       Total                        FCC Limit
                                                     Factors

                                                  Ant.       Cable         Actual          Actual            Limit
 Freq.      Reading         Detect                                                                                       Margin
                                         Pol.    Factor      loss         (㏈㎶/m)          (㏈㎶/m)           (㏈㎶/m)
  (㎒)        (㏈㎶)           Mode                                                                                          (㏈)
                                                 (㏈/m)        (㏈)          at 3 m          at 30 m          at 30 m

16.086        2.70     Quasi-Peak         H      20.17        0.55          23.42           -16.58          29.54         46.12


- Spurious emission above 30 ㎒

     Radiated Emissions                  Ant.       Correction Factors                Total                  FCC Limit

                                                    Ant.                              Actual          Limit
 Freq.      Reading         Detect                                Cable loss                                            Margin
                                         Pol.      Factor                            (㏈㎶/m)          (㏈㎶/m)
  (㎒)        (㏈㎶)           Mode                                  & Amp (㏈)                                              (㏈)
                                                   (㏈/m)                              at 3 m          at 3 m

39.42        40.24     Quasi-Peak         H         15.80            -26.94           29.10              40.00          10.90

101.86       40.20     Quasi-Peak         H         14.36            -26.26           28.30              43.50          15.20

254.39       41.76     Quasi-Peak         V         13.99            -24.95           30.80              46.00          15.20

489.82       41.74     Quasi-Peak         V         18.43            -25.27           34.90              46.00          11.10

711.55       41.66     Quasi-Peak         V         21.78            -24.54           38.90              46.00           7.10

990.75       41.69     Quasi-Peak         V         24.27            -22.86           43.10              54.00          10.90


Note:
1.  30 m Limit (㎶/m) = 20log (15 848) = 84.00 ㏈㎶/m
2.  3 m distance compensation      = 40 log (3/30) = -40 ㏈㎶/m
3.  300 m distance compensation    = 40 log (3/300) = -80 ㏈㎶/m
4.  Other Spurious Emission Frequencies were not detected up to 1 000 ㎒.
The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, except in full, without prior written permission of the Company.
SGS Korea Co., Ltd. (Gunpo Laboratory)     4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 435-040     http://www.sgsgroup.kr
RTT5041-20(2014.01.20)(2)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370               A4(210 mmⅹ297 mm)


 Report Number : F690501/RF-RTL008133                                                    Page: 16                  of        20


4. Frequency Stability
4.1. Test Setup

                                         Temperature Chamber
                                               (PL-1J)




 Spectrum Analyzer                                      EUT
     (FSV30)




                                            DC Power Supply
                                               (U8002A)


4.1.1. Actual equipment used for Frequency Stability
                                                                                                          Cal.
   Equipment          Manufacturer              Model                  S/N             Cal. Date                        Cal. Due
                                                                                                        Interval

 Signal Generator           Agilent            E8257D              MY51501169        Jul. 17, 2014      Annual      Jul. 17, 2015

Spectrum Analyzer            R&S                FSV30                 100768        Mar. 27, 2014       Annual     Mar. 27, 2015

   Temperature
                      ESPEC CORP.               PL-1J               15000793         Jun. 25, 2014      Annual      Jun. 25, 2015
    Chamber

    Attenuator              MCLI              FAS-12-10                  1           Jun. 20, 2014      Annual      Jun. 20, 2015

 DC Power Supply            Agilent            U8002A              MY49030063       Dec. 12, 2013       Annual     Dec. 12, 2014




The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, except in full, without prior written permission of the Company.
SGS Korea Co., Ltd. (Gunpo Laboratory)    4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 435-040      http://www.sgsgroup.kr
RTT5041-20(2014.01.20)(2)                       Tel. +82 31 428 5700 / Fax. +82 31 427 2370                A4(210 mmⅹ297 mm)


 Report Number : F690501/RF-RTL008133                                                   Page: 17             of       20


4.2. Limit

According to §15.225(e), the frequency tolerance of the carrier signal shall be maintained within +/-
0.01 % of the operating frequency over a temperature variation of –20 degrees to +50 degrees C at
normal supply voltage, and for a variation in the primary supply voltage from 85 % to 115 % of the
rated supply voltage at a temperature of 20 degrees C. For battery operated equipment, the
equipment tests shall be performed using a new battery.

4.3. Test Procedures

a. Place the EUT on the table and set it in the transmitting mode.
b. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port
   to the spectrum analyzer.
c. Set the environment into appropriate environment.
d. Set the spectrum analyzer as RBW = 10 ㎑, VBW = 30 ㎑, Span = 1 ㎒, Sweep time = auto.
e. Mark the peak frequency and measure the frequency tolerance using frequency counter function.
f. Repeat until all the results are investigated.




The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, except in full, without prior written permission of the Company.
SGS Korea Co., Ltd. (Gunpo Laboratory)   4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 435-040   http://www.sgsgroup.kr
RTT5041-20(2014.01.20)(2)                      Tel. +82 31 428 5700 / Fax. +82 31 427 2370             A4(210 mmⅹ297 mm)


 Report Number : F690501/RF-RTL008133                                                        Page: 18             of       20


4.4. Test Result

Ambient temperature           : (23 ± 1) ℃
Relative humidity             : 47   % R.H.

Operating Frequency : 13 560 000 ㎐
Reference Voltage : DC 3.80 V
Deviation Limit : ± 0.01 % = ± 1 356 ㎐

Temperature Variations
       Power                     Temperature                  Frequency                 Freq. Dev.             Deviation
        (VDC)                       (℃)                          (㎐)                       (㎐)                   (%)
                                         -20                   13 560 236                    236               0.001 740

                                         -10                   13 560 271                    271               0.001 999

                                          0                    13 560 933                    933               0.006 881

                                         +10                   13 559 749                   -251               -0.001 851

           3.80                    +20(Ref)                    13 560 409                    409               0.003 016

                                         +25                   13 560 599                    599               0.004 417

                                         +30                   13 560 427                    427               0.003 149

                                         +40                   13 560 527                    527               0.003 886

                                         +50                   13 561 101                   1 101              0.008 119


Voltage Variations
        Power                    Temperature                  Frequency                 Freq. Dev.             Deviation
         (VDC)                      (℃)                          (㎐)                       (㎐)                   (%)
Battery End Point (3.05)                 +20                   13 560 330                    330               0.002 434

      115 % (4.37)                       +20                   13 560 633                    633               0.004 668




The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, except in full, without prior written permission of the Company.
SGS Korea Co., Ltd. (Gunpo Laboratory)        4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 435-040   http://www.sgsgroup.kr
RTT5041-20(2014.01.20)(2)                           Tel. +82 31 428 5700 / Fax. +82 31 427 2370             A4(210 mmⅹ297 mm)


 Report Number : F690501/RF-RTL008133                                                   Page: 19                  of        20


5. 20 ㏈ Bandwidth

5.1. Test Setup


 Spectrum Analyzer                                     EUT
     (FSV30)



5.1.1. Actual equipment used for Frequency Stability
                                                                                                         Cal.
   Equipment          Manufacturer             Model                  S/N             Cal. Date                        Cal. Due
                                                                                                       Interval

 Signal Generator           Agilent           E8257D              MY51501169        Jul. 17, 2014      Annual      Jul. 17, 2015

Spectrum Analyzer            R&S               FSV30                 100768        Mar. 27, 2014       Annual     Mar. 27, 2015

    Attenuator              MCLI             FAS-12-10                  1           Jun. 20, 2014      Annual      Jun. 20, 2015

 DC Power Supply            Agilent           U8002A              MY49030063       Dec. 12, 2013       Annual     Dec. 12, 2014



5.2. Limit

None ; for reporting purposes only.

5.3. Test Procedures

a. Place the EUT on the table and set it in the transmitting mode.
b. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port
   to the spectrum analyzer.
c. Set the spectrum analyzer as RBW = 10 ㎑, VBW = 30 ㎑, Span = 2 ㎒, Sweep time = auto.
d. Mark the peak frequency and 20 ㏈ (upper and lower) frequency.
e. Repeat until all the rest channels are investigated.




The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, except in full, without prior written permission of the Company.
SGS Korea Co., Ltd. (Gunpo Laboratory)   4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 435-040      http://www.sgsgroup.kr
RTT5041-20(2014.01.20)(2)                      Tel. +82 31 428 5700 / Fax. +82 31 427 2370                A4(210 mmⅹ297 mm)


 Report Number : F690501/RF-RTL008133                                                   Page: 20             of       20


5.4. Test Result

Ambient temperature            : (23 ± 1) ℃
Relative humidity              : 47   % R.H.

                     Frequency                                                    20 ㏈ Bandwidth
                        (㎒)                                                            (㎑)
                            13.56                                                        438.00




The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, except in full, without prior written permission of the Company.
SGS Korea Co., Ltd. (Gunpo Laboratory)   4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 435-040   http://www.sgsgroup.kr
RTT5041-20(2014.01.20)(2)                      Tel. +82 31 428 5700 / Fax. +82 31 427 2370             A4(210 mmⅹ297 mm)



Document Created: 2019-11-13 19:08:18
Document Modified: 2019-11-13 19:08:18

© 2025 FCC.report