UNII Test Report 2

FCC ID: ZNFL722DL

Test Report

Download: PDF
FCCID_4289032

7.6.3 Radiated Band Edge Measurements (40MHz BW)
§15.407(b.1)(b.2) §15.205 §15.209; RSS-Gen [8.9]

Worst Case Mode:                                      802.11n
Worst Case Transfer Rate:                             MCS0
Distance of Measurements:                             3 Meters
Operating Frequency:                                  5190MHz
Channel:                                              38




Plot 7-92. Radiated Lower Band Edge Plot (Average                                                  Plot 7-93. Radiated Lower Band Edge Plot (Peak –
                   – UNII Band 1)                                                                                     UNII Band 1)

Worst Case Mode:                                      802.11n
Worst Case Transfer Rate:                             MCS0
Distance of Measurements:                             3 Meters
Operating Frequency:                                  5310MHz
Channel:                                              62




Plot 7-94. Radiated Upper Band Edge Plot (Average                                                   Plot 7-95. Radiated Upper Band Edge Plot (Peak –
                  – UNII Band 2A)                                                                                     UNII Band 2A)




                                                                                 MEASUREMENT REPORT                                                               Approved by:
FCC ID: ZNFL722DL
                                                                                    (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                       Test Dates:                     EUT Type:
                                                                                                                                                                  Page 76 of 92
1M1904080056-08-R1.ZNF                 4/08 - 5/03/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                      V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Worst Case Mode:                                      802.11n
Worst Case Transfer Rate:                             MCS0
Distance of Measurements:                             3 Meters
Operating Frequency:                                  5510MHz
Channel:                                              102




Plot 7-96. Radiated Lower Band Edge Plot (Average                                                  Plot 7-97. Radiated Lower Band Edge Plot (Peak –
                  – UNII Band 2C)                                                                                    UNII Band 2C)

Worst Case Mode:                                      802.11n                                     Worst Case Mode:                                      802.11n
Worst Case Transfer Rate:                             MCS0                                        Worst Case Transfer Rate:                             MCS0
Distance of Measurements:                             3 Meters                                    Distance of Measurements:                             3 Meters
Operating Frequency:                                  5670MHz                                     Operating Frequency:                                  5755MHz
Channel:                                              134                                         Channel:                                              151




  Plot 7-98. Radiated Upper Band Edge Plot (Peak –                                                 Plot 7-99. Radiated Lower Band Edge Plot (Peak –
                    UNII Band 2C)                                                                                     UNII Band 3)




                                                                                 MEASUREMENT REPORT                                                               Approved by:
FCC ID: ZNFL722DL
                                                                                    (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                       Test Dates:                     EUT Type:
                                                                                                                                                                  Page 77 of 92
1M1904080056-08-R1.ZNF                 4/08 - 5/03/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                      V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Worst Case Mode:                                      802.11n
Worst Case Transfer Rate:                             MCS0
Distance of Measurements:                             3 Meters
Operating Frequency:                                  5795MHz
Channel:                                              159




 Plot 7-100. Radiated Upper Band Edge Plot (Peak –
                    UNII Band 3)




                                                                                 MEASUREMENT REPORT                                                               Approved by:
FCC ID: ZNFL722DL
                                                                                    (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                       Test Dates:                     EUT Type:
                                                                                                                                                                  Page 78 of 92
1M1904080056-08-R1.ZNF                 4/08 - 5/03/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                      V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


7.6.4 Radiated Band Edge Measurements (80MHz BW)
§15.407(b.1)(b.2) §15.205 §15.209; RSS-Gen [8.9]

Worst Case Mode:                                      802.11ac
Worst Case Transfer Rate:                             MCS0
Distance of Measurements:                             3 Meters
Operating Frequency:                                  5210MHz
Channel:                                              42




        Plot 7-101. Radiated Lower Band Edge Plot                                                 Plot 7-102. Radiated Lower Band Edge Plot (Peak –
                  (Average – UNII Band 1)                                                                            UNII Band 1)

Worst Case Mode:                                      802.11ac
Worst Case Transfer Rate:                             MCS0
Distance of Measurements:                             3 Meters
Operating Frequency:                                  5290MHz
Channel:                                              58




        Plot 7-103. Radiated Upper Band Edge Plot                                                 Plot 7-104. Radiated Upper Band Edge Plot (Peak –
                 (Average – UNII Band 2A)                                                                            UNII Band 2A)




                                                                                 MEASUREMENT REPORT                                                               Approved by:
FCC ID: ZNFL722DL
                                                                                    (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                       Test Dates:                     EUT Type:
                                                                                                                                                                  Page 79 of 92
1M1904080056-08-R1.ZNF                 4/08 - 5/03/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                      V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Worst Case Mode:                                      802.11ac
Worst Case Transfer Rate:                             MCS0
Distance of Measurements:                             3 Meters
Operating Frequency:                                  5530MHz
Channel:                                              106




        Plot 7-105. Radiated Lower Band Edge Plot                                                 Plot 7-106. Radiated Lower Band Edge Plot (Peak –
                 (Average – UNII Band 2C)                                                                            UNII Band 2C)

Worst Case Mode:                                      802.11ac
Worst Case Transfer Rate:                             MCS0
Distance of Measurements:                             3 Meters
Operating Frequency:                                  5775MHz
Channel:                                              155




Plot 7-107. Radiated Lower Band Edge Plot (Peak –
                   UNII Band 3)




                                                                                 MEASUREMENT REPORT                                                               Approved by:
FCC ID: ZNFL722DL
                                                                                    (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                       Test Dates:                     EUT Type:
                                                                                                                                                                  Page 80 of 92
1M1904080056-08-R1.ZNF                 4/08 - 5/03/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                      V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Worst Case Mode:                                      802.11ac
Worst Case Transfer Rate:                             MCS0
Distance of Measurements:                             3 Meters
Operating Frequency:                                  5775MHz
Channel:                                              155




 Plot 7-108. Radiated Upper Band Edge Plot (Peak –
                    UNII Band 3)




                                                                                 MEASUREMENT REPORT                                                               Approved by:
FCC ID: ZNFL722DL
                                                                                    (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                       Test Dates:                     EUT Type:
                                                                                                                                                                  Page 81 of 92
1M1904080056-08-R1.ZNF                 4/08 - 5/03/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                      V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


7.7           Radiated Spurious Emissions Measurements – Below 1GHz
§15.209; RSS-Gen [8.9]

Test Overview and Limit

All out of band radiated spurious emissions are measured with a spectrum analyzer connected to a receive
antenna while the EUT is operating at its maximum duty cycle, at maximum power, and at the appropriate
frequencies. All data rates and modes were investigated for radiated spurious emissions. Only the radiated
emissions of the configuration that produced the worst case emissions are reported in this section.

All out of band emissions appearing in a restricted band as specified in Section 15.205 of the Title 47 CFR
and Table 6 of RSS-Gen (8.10) must not exceed the limits shown in Table 7-65 per Section 15.209 and
RSS-Gen (8.9).

                                                                                   Field Strength                           Measured Distance
                                        Frequency
                                                                                       [V/m]                                   [Meters]
                                   0.009 – 0.490 MHz                                  2400/F (kHz)                                        300
                                   0.490 – 1.705 MHz                                 24000/F (kHz)                                        30
                                   1.705 – 30.00 MHz                                      30                                              30
                                   30.00 – 88.00 MHz                                      100                                              3
                                   88.00 – 216.0 MHz                                      150                                              3
                                   216.0 – 960.0 MHz                                      200                                              3
                                   Above 960.0 MHz                                        500                                              3
                                                                       Table 7-22. Radiated Limits

Test Procedures Used

ANSI C63.10-2013

Test Settings

             Quasi-Peak Field Strength Measurements

             1. Analyzer center frequency was set to the frequency of the radiated spurious emission of interest
             2. RBW = 120kHz (for emissions from 30MHz – 1GHz)
             3. Detector = quasi-peak
             4. Sweep time = auto couple
             5. Trace mode = max hold
             6. Trace was allowed to stabilize




                                                                                MEASUREMENT REPORT                                                                Approved by:
FCC ID: ZNFL722DL
                                                                                   (CERTIFICATION)                                                                Quality Manager
Test Report S/N:                   Test Dates:                      EUT Type:
1M1904080056-08-                                                                                                                                                  Page 82 of 92
                                   4/08 - 5/03/2019                 Portable Handset
R1.ZNF
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                      V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Test Setup

The EUT and measurement equipment were set up as shown in the diagrams below.




                                                           Figure 7-6. Radiated Test Setup < 30MHz




                                                            Figure 7-7. Radiated Test Setup < 1GHz




                                                                                MEASUREMENT REPORT                                                                Approved by:
FCC ID: ZNFL722DL
                                                                                   (CERTIFICATION)                                                                Quality Manager
Test Report S/N:                   Test Dates:                      EUT Type:
1M1904080056-08-                                                                                                                                                  Page 83 of 92
                                   4/08 - 5/03/2019                 Portable Handset
R1.ZNF
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                      V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Test Notes

      1. All emissions lying in restricted bands specified in §15.205 and RSS-Gen (8.10) are below the limit shown
             in Table 7-65.
      2. The broadband receive antenna is manipulated through vertical and horizontal polarizations during the
             tests. The EUT is manipulated through three orthogonal planes.
      3. This unit was tested with its standard battery.
      4. The spectrum is investigated using a peak detector and final measurements are recorded using CISPR
             quasi peak detector. The worst-case emissions are reported however emissions whose levels were not
             within 20dB of the respective limits were not reported.
      5. Emissions were measured at a 3 meter test distance.
      6. Emissions are investigated while operating on the center channel of the mode, band, and modulation that
             produced the worst case results during the transmitter spurious emissions testing.
      7. No spurious emissions were detected within 20dB of the limit below 30MHz.
      8. The results recorded using the broadband antenna is known to correlate with the results obtained by
             using a tuned dipole with an acceptable degree of accuracy. The VSWR for the measurement antenna
             was found to be less than 2:1.
      9. The wide spectrum spurious emissions plots shown on the following pages are used only for the purpose
             of emission identification. There were no emissions detected in the 30MHz – 1GHz frequency range, as
             shown in the subsequent plots.




                                                                                MEASUREMENT REPORT                                                                Approved by:
FCC ID: ZNFL722DL
                                                                                   (CERTIFICATION)                                                                Quality Manager
Test Report S/N:                   Test Dates:                      EUT Type:
1M1904080056-08-                                                                                                                                                  Page 84 of 92
                                   4/08 - 5/03/2019                 Portable Handset
R1.ZNF
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                      V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Radiated Spurious Emissions Measurements (Below 1GHz)
§15.209; RSS-Gen [8.9]




                                 Plot 7-109. Radiated Spurious Plot below 1GHz (802.11a – U3 Ch. 157)




                                                                                MEASUREMENT REPORT                                                                Approved by:
FCC ID: ZNFL722DL
                                                                                   (CERTIFICATION)                                                                Quality Manager
Test Report S/N:                   Test Dates:                      EUT Type:
1M1904080056-08-                                                                                                                                                  Page 85 of 92
                                   4/08 - 5/03/2019                 Portable Handset
R1.ZNF
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                      V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


7.8           Line-Conducted Test Data
§15.407; RSS-Gen [8.8]

Test Overview and Limit

All AC line conducted spurious emissions are measured with a receiver connected to a grounded LISN while the
EUT is operating at its maximum duty cycle, at maximum power, and at the appropriate frequencies. All data rates
and modes were investigated for conducted spurious emissions. Only the conducted emissions of the
configuration that produced the worst case emissions are reported in this section.

All conducted emissions must not exceed the limits shown in the table below, per Section 15.207 and
RSS-Gen (8.8).


                             Frequency of emission                                               Conducted Limit (dBV)
                                    (MHz)
                                                                                      Quasi-peak                                      Average
                                          0.15 – 0.5                                   66 to 56*                                      56 to 46*
                                           0.5 – 5                                        56                                             46
                                            5 – 30                                        60                                             50
                                                                     Table 7-23. Conducted Limits

*Decreases with the logarithm of the frequency.

Test Procedures Used

ANSI C63.10-2013, Section 6.2

Test Settings

             Quasi-Peak Field Strength Measurements

             1. Analyzer center frequency was set to the frequency of the spurious emission of interest
             2. RBW = 9kHz (for emissions from 150kHz – 30MHz)
             3. Detector = quasi-peak
             4. Sweep time = auto couple
             5. Trace mode = max hold
             6. Trace was allowed to stabilize
             Average Field Strength Measurements

             1. Analyzer center frequency was set to the frequency of the spurious emission of interest
             2. RBW = 9kHz (for emissions from 150kHz – 30MHz)
             3. Detector = RMS
             4. Sweep time = auto couple
             5. Trace mode = max hold
             6. Trace was allowed to stabilize


                                                                                MEASUREMENT REPORT                                                                Approved by:
FCC ID: ZNFL722DL
                                                                                   (CERTIFICATION)                                                                Quality Manager
Test Report S/N:                   Test Dates:                      EUT Type:
1M1904080056-08-                                                                                                                                                  Page 86 of 92
                                   4/08 - 5/03/2019                 Portable Handset
R1.ZNF
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                      V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Test Setup

The EUT and measurement equipment were set up as shown in the diagram below.




                                                  Figure 7-8. Test Instrument & Measurement Setup

Test Notes

1.        All modes of operation were investigated and the worst-case emissions are reported using mid channel.
          The emissions found were not affected by the choice of channel used during testing.
2.        The limit for an intentional radiator from 150kHz to 30MHz are specified in 15.207 and RSS-Gen (8.8).
3.        Corr. (dB) = Cable loss (dB) + LISN insertion factor (dB)
4.        QP/AV Level (dBV) = QP/AV Analyzer/Receiver Level (dBV) + Corr. (dB)
5.        Margin (dB) = QP/AV Limit (dBV) - QP/AV Level (dBV)
6.        Traces shown in plot are made using a peak detector.
7.        Deviations to the Specifications: None.




                                                                                MEASUREMENT REPORT                                                                Approved by:
FCC ID: ZNFL722DL
                                                                                   (CERTIFICATION)                                                                Quality Manager
Test Report S/N:                   Test Dates:                      EUT Type:
1M1904080056-08-                                                                                                                                                  Page 87 of 92
                                   4/08 - 5/03/2019                 Portable Handset
R1.ZNF
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                      V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                                        Plot 7-110. Line Conducted Plot with 802.11a UNII Band 1 (L1)




                                         Plot 7-111. Line Conducted Plot with 802.11a UNII Band 1 (N)

                                                                                MEASUREMENT REPORT                                                                Approved by:
FCC ID: ZNFL722DL
                                                                                   (CERTIFICATION)                                                                Quality Manager
Test Report S/N:                   Test Dates:                      EUT Type:
1M1904080056-08-                                                                                                                                                  Page 88 of 92
                                   4/08 - 5/03/2019                 Portable Handset
R1.ZNF
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                      V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                                       Plot 7-112. Line Conducted Plot with 802.11a UNII Band 2A (L1)




                                       Plot 7-113. Line Conducted Plot with 802.11a UNII Band 2A (N)


                                                                                MEASUREMENT REPORT                                                                Approved by:
FCC ID: ZNFL722DL
                                                                                   (CERTIFICATION)                                                                Quality Manager
Test Report S/N:                   Test Dates:                      EUT Type:
1M1904080056-08-                                                                                                                                                  Page 89 of 92
                                   4/08 - 5/03/2019                 Portable Handset
R1.ZNF
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                      V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                                       Plot 7-114. Line Conducted Plot with 802.11a UNII Band 2C (L1)




                                       Plot 7-115. Line Conducted Plot with 802.11a UNII Band 2C (N)


                                                                                MEASUREMENT REPORT                                                                Approved by:
FCC ID: ZNFL722DL
                                                                                   (CERTIFICATION)                                                                Quality Manager
Test Report S/N:                   Test Dates:                      EUT Type:
1M1904080056-08-                                                                                                                                                  Page 90 of 92
                                   4/08 - 5/03/2019                 Portable Handset
R1.ZNF
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                      V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                                        Plot 7-116. Line Conducted Plot with 802.11a UNII Band 3 (L1)




                                         Plot 7-117. Line Conducted Plot with 802.11a UNII Band 3 (N)


                                                                                MEASUREMENT REPORT                                                                Approved by:
FCC ID: ZNFL722DL
                                                                                   (CERTIFICATION)                                                                Quality Manager
Test Report S/N:                   Test Dates:                      EUT Type:
1M1904080056-08-                                                                                                                                                  Page 91 of 92
                                   4/08 - 5/03/2019                 Portable Handset
R1.ZNF
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                      V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


8.0           CONCLUSION


 The       data        collected          relate       only       the      item(s)         tested        and        show         that      the      LG        Portable           Handset
 FCC ID: ZNFL722DL is in compliance with Part 15 Subpart E (15.407) of the FCC Rules.




                                                                                 MEASUREMENT REPORT                                                                Approved by:
  FCC ID: ZNFL722DL
                                                                                    (CERTIFICATION)                                                                Quality Manager
  Test Report S/N:                  Test Dates:                      EUT Type:
  1M1904080056-08-                                                                                                                                                 Page 92 of 92
                                    4/08 - 5/03/2019                 Portable Handset
  R1.ZNF
 © 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                      V 9.0 02/01/2019
 All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
 microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
 rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.



Document Created: 2019-05-25 00:45:16
Document Modified: 2019-05-25 00:45:16

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC