16I22652-S3V1 HAC_RF_App B System Validation Plots

FCC ID: ZNFL61AL

Test Report

Download: PDF
FCCID_2902834

Test Laboratory: UL Verification Services Inc., SAR Lab 2                           Date: 1/13/2016

HAC-RF Emission
Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/14/2015;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1257; Calibrated: 9/16/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

Dipole E-Field measurement 835MHz/835 MHz/Hearing Aid Compatibility Test at 15mm
distance (41x361x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 125.1 V/m; Power Drift = -0.07 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 109.9 V/m
Near-field category: M4 (AWF 0 dB)

                                          PMF scaled E-field
                                          Grid 1 M4 Grid 2 M4 Grid 3 M4
                                          107.2 V/m         109.9 V/m   108.1 V/m
                                          Grid 4 M4         Grid 5 M4   Grid 6 M4
                                          62.80 V/m         64.59 V/m   64.26 V/m
                                          Grid 7 M4         Grid 8 M4   Grid 9 M4
                                          103.4 V/m         106.1 V/m   105.1 V/m




                      0 dB = 109.9 V/m = 40.82 dBV/m



                                                                                                      Plot No. 1


Test Laboratory: UL Verification Services Inc., SAR Lab 2                           Date: 1/13/2016

HAC-RF Emission
Communication System: UID 0, CW; Frequency: 1880 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/14/2015;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1257; Calibrated: 9/16/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

Dipole E-Field Measurement 1880MHz/1880 MHz/Hearing Aid Compatibility Test at
15mm distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 137.2 V/m; Power Drift = 0.07 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 91.18 V/m
Near-field category: M3 (AWF 0 dB)

                                          PMF scaled E-field
                                          Grid 1 M3 Grid 2 M3 Grid 3 M3
                                          87.01 V/m         87.69 V/m   84.70 V/m
                                          Grid 4 M3         Grid 5 M3   Grid 6 M3
                                          70.90 V/m         72.64 V/m   72.39 V/m
                                          Grid 7 M3         Grid 8 M3   Grid 9 M3
                                          89.08 V/m         91.18 V/m   89.95 V/m




                      0 dB = 91.18 V/m = 39.20 dBV/m