RF Exposure Info 4

FCC ID: ZNFL322DL

RF Exposure Info

Download: PDF
FCCID_4322049

                                                                Figure D-3
                                                    750MHz Head Tissue Equivalent Matter




                                                                                           Approved by:
      FCC ID ZNFL322DL                                        SAR EVALUATION REPORT
                                                                                           Quality Manager
      Test Dates:                       DUT Type:                                          APPENDIX D:
      05/14/19 - 05/31/19               Portable Handset                                   Page 3 of 4
© 2019 PCTEST Engineering Laboratory, Inc.                                                  REV 21.3 M
                                                                                             02/15/2019


                                                              Figure D-4
                                         Composition of 2.4 GHz Head Tissue Equivalent Matter

Note: 2.4 GHz head liquid recipes are proprietary SPEAG. Since the composition is approximate to the actual
liquids utilized, the manufacturer tissue-equivalent liquid data sheets are provided below.




                                                                  Figure D-5
                                                    2.4 GHz Head Tissue Equivalent Matter


                                                                                                Approved by:
      FCC ID ZNFL322DL                                        SAR EVALUATION REPORT
                                                                                                Quality Manager
      Test Dates:                       DUT Type:                                               APPENDIX D:
      05/14/19 - 05/31/19               Portable Handset                                        Page 4 of 4
© 2019 PCTEST Engineering Laboratory, Inc.                                                       REV 21.3 M
                                                                                                  02/15/2019


APPENDIX E: SAR SYSTEM VALIDATION

Per FCC KDB Publication 865664 D02v01r02, SAR system validation status should be documented to confirm
measurement accuracy. The SAR systems (including SAR probes, system components and software versions)
used for this device were validated against its performance specifications prior to the SAR measurements.
Reference dipoles were used with the required tissue- equivalent media for system validation, according to the
procedures outlined in FCC KDB Publication 865664 D01v01r04 and IEEE 1528-2013. Since SAR probe
calibrations are frequency dependent, each probe calibration point was validated at a frequency within the valid
frequency range of the probe calibration point, using the system that normally operates with the probe for routine
SAR measurements and according to the required tissue-equivalent media.

A tabulated summary of the system validation status including the validation date(s), measurement frequencies,
SAR probes and tissue dielectric parameters has been included.

                                                                  Table E-1
                                                      SAR System Validation Summary – 1g
                                                                                              CW VALIDATION           MOD. VALIDATION
  SAR           Freq.                  Probe                            Cond.   Perm.            PROBE PROBE
                            Date                    Probe Cal Point                      SENSITI                   MOD.      DUTY
 System        (MHz)                    SN                               (σ)     (εr)            LINEARI ISOTRO                           PAR
                                                                                          VITY                     TYPE     FACTOR
                                                                                                    TY      PY
     H          750      9/5/2018       7409         750      Head      0.887   41.851    PASS    PASS    PASS      N/A       N/A         N/A
     H          835      7/13/2018      7409         835      Head      0.932   43.227    PASS    PASS    PASS     GMSK      PASS         N/A
     E         1750      2/6/2019       3589        1750      Head      1.363    41.67    PASS    PASS    PASS      N/A       N/A         N/A
     E         1900      3/11/2019      3589        1900      Head      1.436   39.615    PASS    PASS    PASS     GMSK      PASS         N/A
     D         1900      5/20/2019      3914        1900      Head      1.454   40.608    PASS    PASS    PASS     GMSK      PASS         N/A
                                                                                                                  OFDM/TD
     E         2450      2/5/2019       3589        2450      Head      1.825   39.836   PASS    PASS    PASS        D       PASS         PASS
     I          750      5/16/2019      7357         750      Body      0.937   56.547   PASS    PASS    PASS       N/A       N/A          N/A
     J          835      3/10/2019      7488         835      Body      0.988   53.868   PASS    PASS    PASS      GMSK      PASS          N/A
     D         1750      4/29/2019      3914        1750      Body      1.529   51.886   PASS    PASS    PASS       N/A       N/A          N/A
     G         1900      8/10/2018      7410        1900      Body      1.567   52.239   PASS    PASS    PASS      GMSK      PASS          N/A
                                                                                                                  OFDM/TD
     L         2450      11/6/2018      7308        2450      Body      2.022   51.315   PASS    PASS    PASS        D       PASS         PASS




NOTE: While the probes have been calibrated for both CW and modulated signals, all measurements were
performed using communication systems calibrated for CW signals only. Modulations in the table above represent
test configurations for which the measurement system has been validated per FCC KDB Publication 865664
D01v01r04 for scenarios when CW probe calibrations are used with other signal types. SAR systems were
validated for modulated signals with a periodic duty cycle, such as GMSK, or with a high peak to average ratio (>5
dB), such as OFDM according to FCC KDB Publication 865664 D01v01r04.




                                                                                                                          Approved by:
      FCC ID ZNFL322DL                                                SAR EVALUATION REPORT
                                                                                                                          Quality Manager
      Test Dates:                       DUT Type:                                                                         APPENDIX E:
      05/14/19 - 05/31/19               Portable Handset                                                                  Page 1 of 1
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                  REV 21.3 M
                                                                                                                             02/15/2019


APPENDIX G                                   POWER REDUCTION VERIFICATION

Per the May 2017 TCBC Workshop Notes, demonstration of proper functioning of the power reduction
mechanisms is required to support the corresponding SAR configurations. The verification process was
divided into two parts: (1) evaluation of output power levels for individual or multiple triggering
mechanisms and (2) evaluation of the triggering distances for proximity-based sensors.

   G.1           Power Verification Procedure
       The power verification was performed according to the following procedure:

       1. A base station simulator was used to establish a conducted RF connection and the output power
          was monitored. The power measurements were confirmed to be within expected tolerances for all
          states before and after a power reduction mechanism was triggered.

       2.      Step 1 was repeated for all relevant modes and frequency bands for the mechanism being
              investigated.

       3. Steps 1 and 2 were repeated for all individual power reduction mechanisms and combinations
          thereof. For the combination cases, one mechanism was switched to a 'triggered' state at a time;
          powers were confirmed to be within tolerances after each additional mechanism was activated.


   G.2           WIFI Verification Summary
                                                            Table G-1
                                                Power Measurement Verification WIFI

                  Mechanism(s)                                                      Conducted Power (dBm)

                                                    Mode/Band
                                                                                Un-triggered    Mechanism #1
                           1st
                                                                                   (Max)         (Reduced)

                   Held-to-Ear                        802.11b                       19.45           16.35
                   Held-to-Ear                        802.11g                        17.1           16.17




                                                                                                            Reviewed by:
FCC ID: ZNFL322DL                                                   SAR EVALUATION REPORT
                                                                                                             Quality Manager
Test Dates:                                      DUT Type:                                                   APPENDIX G:
05/14/19 - 05/31/19                              Portable Handset                                             Page 1 of 1
© 2019 PCTEST Engineering Laboratory, Inc.                                                                         REV 20.05 M
                                                                                                                    11/15/2017



Document Created: 2019-06-19 01:49:17
Document Modified: 2019-06-19 01:49:17

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC