16I22596-S3V1 HAC_RF_App F Dipole Cal. Certificates

FCC ID: ZNFK373

Test Report

Download: PDF
FCCID_2884938

Calibration Laboratory of                                               ol//z                                   S   Schweizerischer Kalibrierdienst




                                                               §
                                                                 I/’l




                                                                                    w
Schmid & Partner                                                                                                C   Service suisse d‘étalonnage




                                                                D
  Engineering AG                                                = //—\\ <                                           Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                     {,/"/fi\\‘\?                                        Swiss Calibration Service
                                                                          Alulus®


Accredited by the Swiss Accreditation Service (SAS)                                                             Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Muritilateral Agreement for the recognition of calibration certificates

Client      UL CCS USA                                                                               Certificate No: CD835V3—1 175_May1 9


CALIBRATION CERTIFICATE
 Object                                CD835V3 — SN: 1175


 Calibration procedure(s)              QA CAL—20.v6
                                       Calibration procedure for dipoles in air




 Calibration date:                     May 18, 2015


 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (S1).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70%.

 Calibration Equipment used (M&TE critical for calibration})
 Primary Standards                       ID #                           Cal Date (Certificate No.)                           Scheduled Calibration
 Power meter EPM—442A                    GB37480704                     07—Oct—14 (No. 217—02020)                            Oct—15
 Power sensor HP 8481A                   US37292783                     07—Oct—14 (No. 217—02020)                            Oct—15
 Power sensor HP 8481A                   MY41092317                     07—Oct—14 (No. 217—02021)                            Oct—15
 Reference 10 dB Attenuator              SN: 5047.2 / 06327             01—Apr—15 (No. 217—02130)                            Mar—16
 Probe ERSDVE                            SN: 2336                       31—Dec—14 (No. ER3—2336_Dec14)                       Dec—15
 Probe H3DV6                             SN: 6065                       31—Dec—14 (No. H3—6065_Dec14)                        Dec—15
 DAE4                                    SN: 781                        12—Sep—14 (No. DAE4—781_Sep14)                       Sep—15

 Secondary Standards                     ID #                           Check Date (in house)                                Scheduled Check
  Power meter Agilent 4419B              SN: GB42420191                 09—Oct—09 (in house check Sep—14)                    In house check: Sep—16
  Power sensor HP E4412A                 SN: US38485102                 05—Jan—10 (in house check Sep—14)                    In   house check:    Sep—16
  Power sensor HP 8482A                  SN: US37295597                 09—Oct—09 (in house check Sep—14)                    In   house check:    Sep—16
  Network Analyzer HP 8753E              US37390585                     18—Oct—01 (in house check Oct—14)                    In   house check:   Oct—15
  RF generator R&S SMT—O6                SN: 832283/011                 27—Aug—12 (in house check Oct—13)                    In   house check:   Oct—16

                                         Name                                           Function                             Signature


                                                                                                                             &f Th
  Calibrated by:                         Leif Klysner                                   Laboratory Technician



  Approved by:                           Fin Bomhoit                                    Deputy Technical Manager     —        Z                   %
                                                                                                                         s          Z7Gzecof /&


                                                                                                                             Issued: May 19, 2015
  This calibration certificate shall not be reproduced except in full without written approval of the laboratory.


Certificate No: CD835V3—1175_May15                           Page 1 of 5


Calibration Laboratory of                                         SCs
                                                                           vifir

                                                                                                Schweizerischer Kalibrierdienst




                                                           )
                                                              Il/’/




                                                                                    &8
Schmid & Partner                                                      Mn
                                                                                                Service suisse d‘étalonnage
  Engineering AG                                                      zn                        Servizio svizzero di taratura




                                                              any




                                                                                    /,/I'
Zeughausstrasse 43, 8004 Zurich, Switzerland                               APRIN                Swiss Calibration Service




                                                             R
                                                                      ’I/’llnln\\‘\\\

Accredited by the Swiss Accreditation Service (SAS)                                         Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreemen:t for the recognition of calibration certificates


References
[1]       ANSI—C63.19—2011
          American National Standard, Methods of Measurement of Compatibility between Wireless Communications
          Devices and Hearing Aids.
Methods Applied and Interpretation of Parameters:
      *   Coordinate System: y—axis is in the direction of the dipole arms. z—axis is from the basis of the antenna
          {mounted on the table) towards its feed point between the two dipole arms. x—axis is normal to the other axes.
          In coincidence with the standards [1], the measurement planes (probe sensor center) are selected to be at a
          distance of 15 mm above the top metal edge of the dipole arms.
      e   Measurement Conditions: Further details are available from the hardcopies at the end of the certificate. All
          figures stated in the certificate are valid at the frequency indicated. The forward power to the dipole connector
          is set with a calibrated power meter connected and monitored with an auxiliary power meter connected to a
          directional coupler. While the dipole under test is connected, the forward power is adjusted to the same level.
      e   Antenna Positioning: The dipole is mounted on a HAC Test Arch phantom using the matching dipole
          positioner with the arms horizontal and the feeding cable coming from the floor. The measurements are
          performed in a shielded room with absorbers around the setup to reduce the reflections.
          It is verified before the mounting of the dipole under the Test Arch phantom, that its arms are perfectly in a
          line. i is installed on the HAC dipole positioner with its arms parallel below the dielectric reference wire and
          able to move elastically in vertical direction without changing its relative position to the top center of the Test
          Arch phantom. The vertical distance to the probe is adjusted after dipole mounting with a DASYS5 Surface
          Check job. Before the measurement, the distance between phantom surface and probe tip is verified. The
          proper measurement distance is selected by choosing the matching section of the HAC Test Arch phantom
          with the proper device reference point (upper surface of the dipole) and the matching grid reference point (tip
          of the probe) considering the probe sensor offset. The vertical distance to the probe is essential for the
          accuracy.
      *   Feed Point Impedance and Return Loss: These parameters are measured using a HP 8753E Vector Network
          Analyzer. The impedance is specified at the SMA connector of the dipole. The influence of reflections was
          eliminating by applying the averaging function while moving the dipole in the air, at least 70cm away from any
          obstacles.
      e   E—field distribution: E field is measured in the x—y—plane with an isotropic ER3D—field probe with 100 mW
          forward power to the anternina feed point. In accordance with [1], the scan area is 20mm wide, its length
          exceeds the dipole arm length (180 or 9$0mm). The sensor center is 15 mm (in z) above the metal top of the
          dipole arms. Two 3D maxima are available near the end of the dipole arms. Assuming the dipole arms are
          perfectly in one line, the average of these two maxima (in subgrid 2 and subgrid 8) is determined to
          compensate for any non—parallelity to the measurement plane as well as the sensor displacement. The E—field
          value stated as calibration value represents the maximum of the interpolated 3D—E—field, in the plane above
          the dipole surface.




  The reported uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by the
  coverage factor k=2, which for a normal distribution corresponds to a coverage probability of approximately 95%.




Certificate No: CD835V3—1175_May15                       Page 2 of 5


Measurement Conditions
    DASY system configuration, as far as not given on page 1.
     DASY Version                                                DASY5                           V52.8.8
      Phantom                                                HAC Test Arch
      Distance Dipole Top — Probe Center                         15 mm
     Scan resolution                                         dx, dy = 5 mm
      Frequency                                          835 MHz + 1 MHz
      Input power drift                                         < 0.05 dB



Maximum Field values at 835 MHz

      E—field 15 mm above dipole surface                            condition            Interpolated maximum
      Maximum measured above high end                           100mW input power        106.3V/m = 40.53 dBV/m
      Maximum measured above low end                            100mW input power        106.3V/m = 40.53 dBV/m
     Averaged maximum above arm                                 100mW input power        106.3V/m + 12.8 % (k=2)



Appendix (Additional assessments outside the scops of SCS 0108)

Antenna Parameters

      Frequency                                                   Return Loss                  Impedance

      800 MHz                                                        16.1 dB                 42.1 Q — 12.2 jQ
      835 MHz                                                        25.2 dB                  48.2 ) + 5.1 jQ
      900 MHz                                                        17.7 dB                 56.9 Q — 12.2 jQ
      950 MHz                                                        20.7 dB                  48.3 Q + 8.9 jQ
      960 MHz                                                        14.9 dB                 56.3 Q + 18.3 jQ



3.2 Antenna Design and Handling

The calibration dipole has a symmetric geometry with a built—in two stub matching network, which leads to the
enhanced bandwidth.
The dipole is built of standard semirigid coaxial cable. The internal matching line is open ended. The antenna is
therefore open for DC signals.
Do not apply force to dipole arms, as they are liable to bend. The soldered connections near the feedpoint may be
damaged. After excessive mechanical stress or overheating, check the impedance characteristics to ensure that the
internal matching network is not affected.

After long term use with 40W radiated power, only a slight warming of the dipole near the feedpoint can be measured.




Certificate No: CD835V3—1175_May15             Page 3 of 5


Impedance Measurement Plot




                                                                      18 May 2015     @7 :51: 01
         CH1i   S$11     LOG       5 dB/REF —15 dB                  2:—25.196 dB      835.000 Aon MHz




                                                                                                        CH1 Markers

                                                                                                        1:—16.121 dB
                                                                                                         $00.000 MHz
         Cor
                                                                                                        3:—17.670 dB
                                                                                                         900.000 MHz

                                                                                                        4:—20.710 dB
                                                                                                        950.000 MHz
         fivg
         16                                                                                             5:—14.914 dB
                                                                                                        960.000 MHz

         H1d

         CH2)   S11      1 U FS          2: 49.248 a   5.11?2 a&   975.36 pH          8$35.000 0o MHz




         Del                                                                                            CH2 Markers
                                                                                                         1: 42.076 a
         Cor                                                                                               —12,.164 a
                                                                                                        $00.000 MHz
                                                                                                         356.949 t
                                                                                                             2.238 a
                                                                                                        300.BB MHz

         AV
         16"
                                                                                                         5: 56.324 a
                                                                                                            18.311 &
         H1d                                                                                            960.000 MHz

                       START 335.000 000 MHz                                   STOP 1 335.000 ABA MHz




Certificate No: CD835V3—1175_May15               Page 4 of 5


DASY5 E—field Result

                                                                                               Date: 18.05.2015

Test Laboratory: SPEAG Lab2

DUT: HAC—Dipole 835 MHz; Type: CD835V3; Serial: CD835V3 — SN: 1175

Communication System: UID 0 — CW ; Frequency: 835 MHz
Medium parameters used: 0 = 0 $/m, & = 1; p = 1000 kg/m*
Phantom section: RF Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C€63.19—2011)

DASY52 Configuration:

    *«   Probe: ER3DV6 — SN2336; ConvF(1, 1, 1); Calibrated: 31.12.2014;
    e    Sensor—Surface: (Fix Surface)
    e    Electronics: DAE4 Sn781; Calibrated: 12.09.2014
    *    Phantom: HAC Test Arch with AMCC; Type: SD HAC PO1 BA; Serial: 1070
    e    DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)

Dipole E—Field measurement @ 835MHz/E—Scan — 835MHz d=15mm/Hearing Aid Compatibility Test (41x361x1):
Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, —6.3 mm
Reference Value = 122.9 V/m; Power Drift = —0.01 dB
Applied MIF = 0.00 dB
RF audio interference level = 40.53 dBV/m
Emission category: M3

                                            MIF scaled E—field

                                            Grid 1 M3      Grid 2 M3       Grid 3 M3
                                            40.32 dBV/m|40.53 dBV/m 40.41 dBV/m

                                            Grid 4 M4                      Grid 6 M4
                                            35.81 dBV/m                    36.01 dBV/m

                                            Grid 7 M3                      Grid 9 M3
                                            40.31 dBV/m|40.53 dBV/m 40.46 dBV/m




                      —1.89


                      —3.78


                      —5.67


                      —7.56


                      —9.45
                               0 dB = 106.3 V/m = 40.53 dBV/m




Certificate No: CD835V3—1175_May15                 Page 5 of 5


Calibration Laboratory of                                                                                           Schweizerischer Kalibrierdienst
                                                                                                            S
Schmid & Partner                                                                                                    Service suisse d‘étalonnage
                                                                                                            C
  Engineering AG                                                                                                    Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                                S       Swiss Calibration Service


Accredited by the Swiss Accreditation Service (SAS)                                                          Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client       UL CCS USA                                                                         Certificate No: CD1880V3—1159_May15

CALIBRATION CERTIFICATE
 Object                                CD1880V3 — SN: 1159


 Calibration procedure(s)              QA CAL—20.v6
                                       Calibration procedure for dipoles in air



 Calibration date:                      May 18, 2015


 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (Sl).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70%.

 Calibration Equipment used (M&TE critical for calibration)
 Primary Standards                       ID #                      Cal Date (Certificate No.)                            Scheduled Calibration
 Power meter EPM—442A                    GB37480704                07—Oct—14 (No. 217—02020)                             Oct—15
 Power sensor HP 8481A                   US37292783                07—Oct—14 (No. 217—02020)                             Oct—15
 Power sensor HP 8481A                   MY41092317                07—Oct—14 (No. 217—02021)                             Oct—15
 Reference 10 dB Attenuator              SN: 5047.2 / 06327        01—Apr—15 (No. 217—02130)                             Mar—16
 Probe ER3DV6                            SN: 2336                  31—Dec—14 (No. ER3—2336_Dec14)                        Dec—15
 Probe H3DV6                             SN: 6065                  31—Dec—14 (No. H3—6065_Dec14)                         Dec—15
 DAE4                                    SN: 781                   12—Sep—14 (No. DAE4—781_Sep14)                        Sep—15


 Secondary Standards                     ID #                      Check Date (in house)                                 Scheduled Check
  Power meter Agilent 4419B              SN: GB42420191            09—Oct—09 (in house check Sep—14)                     In house check: Sep—16
  Power sensor HP E4412A                 SN: US38485102            O5—Jan—10 (in house check Sep—14)                     In house check: Sep—16
  Power sensor HP 8482A                  SN: US37295597            09—Oct—09 (in house check Sep—14)                     In house check: Sep—16
  Network Analyzer HP 8753E              US37390585                18—Oct—01 (in house check Oct—14)                     In house check: Oct—15
  RF generator R&S SMT—O6                SN: 832283/011            27—Aug—12 (in house check Oct—13)                     In house check: Oct—16




                                                                                                                        spty
                                         Name                                   Function                                  Signature
  Calibrated by:                         Leif Klysner                           Laboratory Technician



  Approved by:                           Fin Bomholt                            Deputy Technical Manager            //
                                                                                                                    Fo        PV
                                                                                                                         Issued: May 19, 2015
  This calibration certificate shall not be reproduced except in full without written approval of the laboratory.


Certificate No: CD1880V3—1159_May15                          Page 1 of 7


Calibration Laboratory of                                            \‘\'L/                     Schweizerischer Kalibrierdienst




                                                                            6'//, /g\‘\\N
                                                             II/'/
Schmid & Partner                                                     m                          Service suisse d‘étalonnage
      Engineering AG
                                                                     T\                         Servizio svizzero di taratura




                                                             NA
Zeughausstrasse 43, 8004 Zurich, Switzerland                         L/   N.X                   Swiss Calibration Service
                                                                     ulatatsS®
Accredited by the Swiss Accreditation Service (SAS)                                         Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates


References
[1]        ANSI—C63.19—2011
           American National Standard, Methods of Measurement of Compatibility between Wireless Communications
           Devices and Hearing Aids.
Methods Applied and Interpretation of Parameters:
       *   Coordinate System: y—axis is in the direction of the dipole arms. z—axis is from the basis of the antenna
           {mounted on the table) towards its feed point between the two dipole arms. x—axis is normal to the other axes.
           In coincidence with the standards [1], the measurement planes (probe sensor center) are selected to be at a
           distance of 15 mm above the top metal edge of the dipole arms.
       «   Measurement Conditions: Further details are available from the hardcopies at the end of the certificate. All
           figures stated in the certificate are valid at the frequency indicated. The forward power to the dipole connector
           is set with a calibrated power meter connected and monitored with an auxiliary power meter connected to a
           directional coupler. While the dipole under test is connected, the forward power is adjusted to the same level.
       e   Antenna Positioning: The dipole is mounted on a HAC Test Arch phantom using the matching dipole
           positioner with the arms horizontal and the feeding cable coming from the floor. The measurements are
           performed in a shielded room with absorbers around the setup to reduce the reflections.
           It is verified before the mounting of the dipole under the Test Arch phantom, that its arms are perfectly in a
           line. It is installed on the HAC dipole positioner with its arms parallel below the dielectric reference wire and
           able to move elastically in vertical direction without changing its relative position to the top center of the Test
           Arch phantom. The vertical distance to the probe is adjusted after dipole mounting with a DASYS Surface
           Check job. Before the measurement, the distance between phantom surface and probe tip is verified. The
           proper measurement distance is selected by choosing the matching section of the HAC Test Arch phantom
           with the proper device reference point (upper surface of the dipole) and the matching grid reference point (tip
           of the probe) considering the probe sensor offset. The vertical distance to the probe is essential for the
           accuracy.
       e   Feed Point Impedance and Return Loss: These parameters are measured using a HP 8753E Vector Network
           Analyzer. The impedance is specified at the SMA connector of the dipole. The influence of reflections was
           eliminating by applying the averaging function while moving the dipole in the air, at least 70cm away from any
           obstacles.
       e   E—field distribution: E field is measured in the x—y—plane with an isotropic ER3D—field probe with 100 mW
           forward power to the antenna feed point. In accordance with [1], the scan area is 20mm wide, its length
           exceeds the dipole arm length (180 or 9O0mm). The sensor center is 15 mm (in z) above the metal top of the
           dipole arms. Two 3D maxima are available near the end of the dipole arms. Assuming the dipole arms are
           perfectly in one line, the average of these two maxima (in subgrid 2 and subgrid 8) is determined to
           compensate for any non—parallelity to the measurement plane as well as the sensor displacement. The E—field
           value stated as calibration value represents the maximum of the interpolated 3D—E—field, in the plane above
           the dipole surface.




 The reported uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by the
 coverage factor k=2, which for a normal distribution corresponds to a coverage probability of approximately 95%.




Certificate No: CD1880V3—1159_May15                     Page 2 of 7


Measurement Conditions
   DASY system configuration, as far as not given on page 1.
     DASY Version                                               DASY5                     V52.8.8
     Phantom                                             HAC Test Arch
     Distance Dipole Top — Probe Center                         15 mm
     Scan resolution                                        dx, dy = 5 mm
                                                       1730 MHz + 1 MHz
     Frequency                                         1880 MHz + 1 MHz
     Input power drift                                     < 0.05 dB


Maxim um Field values at 1730 MHz

     E—field 15 mm above dipole surface                            condition       Interpolated maximum
     Maximum measured above high end                           100mW input power   96.8V/m = 39.71 dBV/m

     Maximum measured above low end                            100mW input power   93.6V/m = 39.42 dBV/m

     Averaged maximum above arm                                100mW input power   95.2V/m + 12.8 % (k=2)


Maximum Field values at 1880 MHz

     E—field 15 mm above dipole surface                            condition       Interpolated maximum

     Maximum measured above high end                           100mW input power   89.9V/m = 39.08 dBV/m

     Maximum measured above low end                            100mW input power   89.1V/m = 39.00 dBV/m

     Averaged maximum above arm                                100mW input power   89.5V/m + 12.8 % (k=2)




Certificate No: CD1880V3—1159_May15           Page 3 of 7


Appendix (Additional assessments outside the scope of SCS 0108)

Antenna Parameters

Nominal Frequencies

     Frequency                                               Return Loss                    Impedance
     1730 MHz                                                   31.2 dB                    49.9 Q + 2.8 jQ
      1880 MHz                                                  19.4 dB                    46.0 Q + 9.5 jQ
      1900 MHz                                                  19.8 dB                   48.8 Q + 10.1 jQ
      1950 MHz                                                  25.7 dB                    52.8 Q + 4.5 |Q
     2000 MHz                                                   22.4 dB                    43.7 Q + 3.1 jQ



3.2 Antenna Design and Handling

The calibration dipole has a symmetric geometry with a built—in two stub matching network, which leads to the
enhanced bandwidth.
The dipole is built of standard semirigid coaxial cable. The internal matching line is open ended. The antenna is
therefore open for DC signals.
Do not apply force to dipole arms, as they are liable to bend. The soidered connections near the feedpoint may be
damaged. After excessive mechanical stress or overheating, check the impedance characteristics to ensure that the
internal matching network is not affected.

After long term use with 40W radiated power, only a slight warming of the dipole near the feedpoint can be measured.




Certificate No: CD1880V3—1159_May15           Page 4 of 7


Impedance Measurement Plot




                                                                  18 May 2015 @8:04141
         CHI sii        Los       5 dB/REF —18 df                2:—19.412 dB 1 880.000 0@d MHz



                                                                                                      CH1 Markers

                                                                                                      1:—31.1 96 dB
                                                                                                       1.73000 GHz

                                                                                                      3:—19.7 91 dB
                                                                                                       1.39000 GHz

                                                                                                      4:—25.7 20 dB
                                                                                                       1.95000 GHz
         A¥g
         16                                                                                           S:—22,.447 dB
                                                                                                       2900000 GHz

         H1d

         CH2    S41     1 U FZ          2: 46.023 a   9.5273 8 806.56 pH         1 880,.000 000 MHz




         Del                                                                                          CH2 Markers
                                                                                                       1: 49,.859 A
         Cor                                                                                              2.7500 «&
                                                                                                      1.73000 GHz


                                                                                                      1.90000 GH
         AEZ]
         16



         H1d

                      CENTER 1 890.000 0d0 MHz                             SPAN 1 900.000 000 MHz




Certificate No: CD1880V3—1159_May15              Page 5 of 7


DASY5 E—field Result

                                                                                               Date: 18.05.2015


Test Laboratory: SPEAG Lab2

DUT: HAC Dipole 1880 MHz; Type: CD1880V3; Serial: CD1880V3 — SN: 1159

Communication System: UID 0 — CW ; Frequency: 1880 MHz, Frequency: 1730 MHz
Medium parameters used: o = 0 S/m, &, = 1;   p = 1000 kg/m*
Phantomsection: RF Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C€63.19—2011)

DASY52 Configuration:

    *   Probe: ER3DV6 — SN2336; ConvF(1, 1, 1); Calibrated: 31.12.2014;
    *   Sensor—Surface: (Fix Surface)
    e   Electronics: DAE4 Sn781; Calibrated: 12.09.2014
    e   Phantom: HAC Test Arch with AMCC; Type: SD HAC PO1 BA; Serial: 1070
    *   DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)


Dipole E—Field measurement @ 1880MHz/E—Scan — 1880MHz d=15mm/Hearing Aid Compatibility Test (41x181x1):
Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, —6.3 mm
Reference Value = 141.1 V/m; Power Drift = 0.00 dB
Applied MIF = 0.00 dB
RF audio interference level = 39.08 dBV/m
Emission category: M2

                                             MIF scaled E—field

                                             Grid 1 M2                    Grid 3 M2
                                             38.8 dBV/m     |39 dBV/m     38.81 dBV/m

                                             Grid 4 M2                    Grid 6 M2
                                             36.64 dBV/m                  36.76 dBV/m

                                             Grid 7 M2                    Grid 9 M2
                                             38.93 dBV/m|39.08 dBV/m|38.95 dBV/m




Certificate No: CD1880V3—1159_ May15                Page 6 of 7


Dipole E—Field measurement @ 1880MHz/E—Scan — 1730MHz d=15mm/Hearing Aid Compatibility Test (41x181x1):
Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, —6.3 mm
Reference Value = 149.1 V/m;, Power Drift =—0.01 dB
Applied MIF = 0.00 dB
RF audio interference level = 39.71 dBV/m
Emission category: M2


                                      MIF scaled E—field

                                       Grid 1 M2               Grid 3 M2
                                       39.22 dBV/m|39.42 dBV/m|39.27 dBV/m

                                       Grid 4 M2               Grid 6 M2
                                       37.48 dBV/m             37.72 dBV/m

                                       Grid 7 M2
                                       39.49 dBV/m|39.71 dBV/m|39.62 dBV/m




                   —1.02


                   —2.05


                   ~3.07


                   —4.10


                   —5.12
                            0 dB = 89.94 V/m = 39.08 dBV/m




Certificate No: CD1880V3—1159_May15           Page 7 of 7



Document Created: 2017-11-16 06:46:53
Document Modified: 2017-11-16 06:46:53

© 2024 FCC.report