According to KDB 447498 D01 General RF Exposure Guidance v06.

At 100 ㎒ to 6 ㎓ and for test separation distances ≤ 50 ㎜, the SAR test exclusion threshold is
determined according to the following:

   [(max. power of channel, including tune-up tolerance, ㎽) / (min. test separation distance, ㎜)]
   x [√f(㎓)] ≤ 3.0


1. SAR test exclusion threshold
Frequency : 2 480 ㎒ (min. separation distances = 0 ㎜)
SAR test exclusion thresholds(5 ㎜) = 3 x 5 / (√ 2.480 ) = 9.525 ㎽


  Max. tune-up          SAR Test Exclusion
  tolerance (㎽)        Thresholds (5 ㎜) (㎽)
        9                       9.525


Calculation value: 9 (㎽) / 5 (㎜) x √ 2.480 = 2.835
So, Calculation value ≤ 3.0

Remark;
-Max. conducted power (㎽) : maximum tolerance power of EUT (9.5 ㏈m)
- Max. conducted power 8.913 (㎽) is less than 9 (㎽), so 9 (㎽) was calculated.
-When the minimum test separation distance is < 5 ㎜, a distance of 5 ㎜ is applied to determine
SAR test exclusion.

2. Conclusion : SAR is not required.