Test Report LE

FCC ID: ZNFHBSAL4

Test Report

Download: PDF
FCCID_4328290



Report Number: F690501/RF-RTL013933                                                        Page:      2      of       34




                                                  Table of contents


 1. General Information --------------------------------------------------------------------------------------       3


 2. Transmitter Radiated Spurious Emissions and Conducted Spurious Emission ----------                               8


 3. 6 ㏈ Bandwidth -------------------------------------------------------------------------------------------       25


 4. Maximum Peak Conducted Output Power ---------------------------------------------------------                   28


 5. Power Spectral Density ---------------------------------------------------------------------------------        31


 6. Antenna Requirement -----------------------------------------------------------------------------------         34




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


Report Number: F690501/RF-RTL013933                                                        Page:      3      of       34


1. General Information
1.1. Testing Laboratory
SGS Korea Co., Ltd. (Gunpo Laboratory)
     - 10-2, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807
     - 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807
     - Designation number: KR0150
All SGS services are rendered in accordance with the applicable SGS conditions of service available on
request and accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx.
Phone No.          : +82 31 688 0901
Fax No.            : +82 31 688 0921

1.2. Details of Applicant
Applicant           :   LG Electronics USA, Inc.
Address             :   1000 Sylvan Avenue, Englewood Cliffs, New Jersey, United States 07632
Contact Person      :   Han, Kyung-Su
Phone No.           :   +1 201 266 2215

1.3. Details of Manufacturer
Company             :   GoerTek
Address             :   No.268 Dongfang Road, High-Tech Industry Development District, Weifang,
                        Shandong, P.R.C

1.4. Description of EUT

Kind of Product                LG STEREO Headset

Model Name                     HBS-AL4

Variant Model Name             HBS-PAL4

Power Supply                   DC 3.7 V

Frequency Range                2 402 ㎒ ~ 2 480 ㎒ (Bluetooth Low Energy)

Modulation Technique           GFSK

Number of Channels             40 channel (Bluetooth Low Energy)

Antenna Type                   FPC antenna

Antenna Gain                   1.80 ㏈ i




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


Report Number: F690501/RF-RTL013933                                                          Page:         4      of        34


1.5. Test Equipment List
                                                                                                         Cal.
   Equipment           Manufacturer                 Model                  S/N           Cal. Date                  Cal. Due
                                                                                                       Interval
 Signal Generator            R&S                   SMR40                 100272        Jun. 12, 2018   Annual     Jun. 12, 2019
 Signal Generator            R&S                 SMBV100A                255834        Jun. 15, 2018   Annual     Jun. 15, 2019
Spectrum Analyzer            R&S                    FSV30                103210        Dec. 05, 2018   Annual     Dec. 05, 2019
Spectrum Analyzer           Agilent                N9020A              MY53421758      Sep. 21, 2018   Annual     Sep. 21, 2019
    Attenuator              MCLI                  FAS-23-20               23834        Jun. 12, 2018   Annual     Jun. 12, 2019
                    Wainwright Instrument
 High Pass Filter                            WHK3.0/18G-10SS               344         May 21, 2019    Annual     May 21, 2020
                           GmbH
                    Wainwright Instrument
 High Pass Filter                           WHNX7.5/26.5G-6SS              15          Jun. 11, 2018   Annual     Jun. 11, 2019
                           GmbH
 Low Pass Filter        Mini-Circuits            NLP-1200+            V 8979400903-2   Feb. 19, 2019   Annual     Feb. 19, 2020
  Power Sensor               R&S                  NRP-Z81                100748        Jun. 12, 2018   Annual     Jun. 12, 2019
 DC Power Supply             R&S                  HMP2020               019258024      Nov. 06, 2018   Annual     Nov. 06, 2019
   Preamplifier             H.P.                   8447F               2944A03909      Aug. 07, 2018   Annual     Aug. 07, 2019
   Preamplifier            Agilent                 8449B               3008A01932      Feb. 22, 2019   Annual     Feb. 22, 2020
   Preamplifier          MITEQ Inc.         JS44-18004000-35-8P          1546891       May 13, 2019    Annual     May 13, 2020
                       Schwarzbeck
  Loop Antenna                                   FMZB 1519               1519-039      Aug. 23, 2017   Biennial   Aug. 23, 2019
                      Mess-Elektronik
                       Schwarzbeck
  Bilog Antenna                                  VULB 9163                01126        Mar. 26, 2018   Biennial   Mar. 26, 2020
                      Mess-Elektronik
  Horn Antenna               R&S                    HF906                100326        Feb. 14, 2018   Biennial   Feb. 14, 2020
                       Schwarzbeck
  Horn Antenna                                   BBHA 9170            BBHA9170431      Sep. 10, 2018   Biennial   Sep. 10, 2020
                      Mess-Elektronik
  Test Receiver              R&S                    ESU26                100109        Jan. 31, 2019   Annual     Jan. 31, 2020
    Turn Table      Innco systems GmbH            DS 1200 S                N/A            N.C.R.         N/A           N.C.R.
                                               CONTROLLER             CO3000/963/383
    Controller      Innco systems GmbH                                                    N.C.R.         N/A           N.C.R.
                                                CO3000-4P                30516/L
                                                                      MA4640/536/383
  Antenna Mast      Innco systems GmbH         MA4640-XP-ET                               N.C.R.         N/A           N.C.R.
                                                                         30516/L
                                                   L×W×H
Anechoic Chamber       SY Corporation                                      N/A            N.C.R.         N/A           N.C.R.
                                            (9.6 m × 6.4 m × 6.6 m)
                                                                                                       Semi-
  Coaxial Cable         SUCOFLEX                  104 (3 m)             MY3258414      Jan. 04, 2019              Jul. 04, 2019
                                                                                                       annual
                                                                                                       Semi-
  Coaxial Cable         SUCOFLEX                 104 (10 m)             MY3145814      Jan. 04, 2019              Jul. 04, 2019
                                                                                                       annual
                                                                                                       Semi-
  Coaxial Cable         Rosenberger            LA1-C006-1500           131014 01/20    Feb. 28, 2019              Aug. 28, 2019
                                                                                                       annual




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807        http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                          Tel. +82 31 428 5700 / Fax. +82 31 427 2370           A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                       Page:      5      of          34


1.6. Summary of Test Results
The EUT has been tested according to the following specifications:


                                 APPLIED STANDARD: FCC Part15 Subpart C

        Section                                             Test Item                                        Result
        15.205(a)
                                       Transmitter Radiated Spurious Emissions and
         15.209                                                                                             Complied
                                             Conducted Spurious Emission
        15.247(d)

     15.247(a)(2)                                       6 ㏈ Bandwidth                                       Complied

     15.247(b)(3)                        Maximum Peak Conducted Output Power                                Complied

        15.247(e)                                   Power Spectral Density                                  Complied

                                                                                                                    1)
         15.207                             AC Power Line Conducted Emission                                  N/A


Note;

1) The AC power line test was not performed because the EUT does not operate while charging.

1.7. Test Procedure(s)
The measurement procedures described in the American National Standard of Procedure for Compliance
Testing of unlicensed Wireless Devices (ANSI C63.10-2013) and the guidance provided in KDB 558074 D01
15.247 Meas Guidance v05r02 were used in the measurement of the DUT.

1.8. Sample Calculation
Where relevant, the following sample calculation is provided:

1.8.1. Conducted Test

Offset value (㏈) = Attenuator (㏈) + Cable loss (㏈)

1.8.2. Radiation Test

Field strength level (㏈㎶/m) = Measured level (㏈㎶) + Antenna factor (㏈) + Cable loss (㏈) - Amplifier gain (㏈)




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                       Page:              6      of       34


1.9. Measurement Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the apparatus:

                     Parameter                                                   Uncertainty (㏈)

                  RF Output Power                                                    ±0.52 ㏈

           Conducted Spurious Emission                                               ±0.76 ㏈

              Power Spectral Density                                                 ±0.41 ㏈

               Occupied Bandwidth                                                    ±9.66 ㎑

          Radiated Emission, 9 ㎑ to 30 ㎒                                             ±3.59 ㏈

           Radiated Emission, below 1 ㎓                                              ±5.88 ㏈

           Radiated Emission, above 1 ㎓                                              ±5.94 ㏈

Uncertainty figures are valid to a confidence level of 95 %.

1.10. Test Report Revision

  Revision              Report Number                Date of Issue                             Description

      0            F690501/RF-RTL013933                2019.06.10                                 Initial


1.11. Information of Variant Models

   Model Name         Description
     HBS-AL4          -Basic model

    HBS-PAL4          -Same to basic mode, but variant model name is made for marketing purpose




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807            http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370                A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                         Page:     7      of       34


1.12. Duty Cycle of EUT
Regarding to KDB 558074 D01 15.247 Meas Guidance v05r02, 6, the maximum duty cycle was investigated
and set the spectrum analyzer as below;
Set RBW ≥ OBW if possible; otherwise, set RBW to the largest available value. Set detector = peak or
average. The zero-span measurement method shall not be used unless both RBW and VBW are > 50/T and
the number of sweep points across duration T exceeds 100.

                                      Duty Cycle                  Correction factor
                                         (%)                            (㏈)

                                        63.20                            1.99


Remark;

1.   Duty Cycle (%) = (Tx on time / Tx on + off time) x 100
2.   Correction factor (㏈) = 10 log (1 / Duty Cycle)

- Test plot




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807     http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                          Tel. +82 31 428 5700 / Fax. +82 31 427 2370       A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                       Page:      8      of       34


2. Transmitter Radiated Spurious Emissions and Conducted Spurious
Emission
2.1. Test Setup
2.1.1. Transmitter Radiated Spurious Emissions

The diagram below shows the test setup that is utilized to make the measurements for emission from 9 ㎑
to 30 ㎒.




The diagram below shows the test setup that is utilized to make the measurements for emission from 30 ㎒
to 1 ㎓.




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                       Page:      9      of       34


The diagram below shows the test setup that is utilized to make the measurements for emission. The
                                                       th
spurious emissions were investigated form 1 ㎓ to the 10 harmonic of the highest fundamental frequency
or 40 ㎓, whichever is lower.




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                       Page:     10      of       34


2.1.2. Conducted Spurious Emission



                                                                                                         Spectrum
        EUT                                          Attenuator
                                                                                                         Analyzer


2.2. Limit

According to §15.247(d), in any 100 ㎑ bandwidth outside the frequency band in which the spread spectrum
or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the
intentional radiator shall be at least 20 ㏈ below that in the 100 ㎑ bandwidth within the band that contains
the highest level of the desired power, based on either an RF conducted or a radiated measurement,
provided the transmitter demonstrates compliance with the peak conducted power limits. If the transmitter
complies with the conducted power limits based on the use of RMS averaging over a time interval, as
permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 ㏈
instead of 20 ㏈. Attenuation below the general limits specified in section §15.209(a) is not required. In
addition, radiated emission which fall in the restricted bands, as defined in section §15.205(a), must also
comply with the radiated emission limits specified in section §15.209(a) (see §15.205(c)).

According to §15.209(a), except as provided elsewhere in this subpart, the emissions from an intentional
radiator shall not exceed the field strength levels specified in the following table:

        Frequency                             Field Strength                           Measurement Distance
           (㎒)                                    (㎶/m)                                      (Meters)
        0.009-0.490                              2 400/F(㎑)                                        300

        0.490-1.705                             24 000/F(㎑)                                         30

         1.705-30.0                                   30                                            30

             30-88                                   100**                                          3

             88-216                                  150**                                          3

          216-960                                    200**                                          3

         Above 960                                    500                                           3


** Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this
section shall not be located in the frequency bands 54-72 ㎒, 76-88 ㎒, 174-216 ㎒ or 470-806 ㎒.
However, operation within these frequency bands is permitted under other sections of this part, e.g.,
§§15.231 and 15.241.


The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                       Page:     11      of       34


2.3. Test Procedures
Radiated emissions from the EUT were measured according to the dictates in section 11.11 & 11.12 of ANSI
C63.10-2013.

2.3.1. Test Procedures for emission below 30 ㎒

1. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter anechoic
   chamber test site. The table was rotated 360 degrees to determine the position of the highest radiation.
2. Then antenna is a loop antenna is fixed at one meter above the ground to determine the maximum value
   of the field strength. Both parallel and perpendicular of the antenna are set to make the measurement.
3. For each suspected emission, the EUT was arranged to its worst case and then the table was turned from
   0 degrees to 360 degrees to find the maximum reading.
4. The test-receiver system was set to average or quasi peak detect function and Specified Bandwidth with
   Maximum Hold Mode.

2.3.2. Test Procedures for emission from above 30 ㎒

1. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter anechoic
   chamber test site below 1 ㎓ and 1.5 meters above the ground at a 3 meter anechoic chamber test site
   above 1 ㎓. The table was rotated 360 degrees to determine the position of the highest radiation.
2. During performing radiated emission below 1 ㎓, the EUT was set 3 meters away from the interference
   receiving antenna, which was mounted on the top of a variable height antenna tower. During performing
   radiated emission above 1 ㎓, the EUT was set 3 meter away from the interference receiving antenna.
3. The antenna is a bi-log antenna, a horn antenna and its height is varied from one meter to four meters
   above the ground to determine the maximum value of the field strength. Both horizontal and vertical
   polarizations of the antenna are set to make the measurement.
4. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to
   heights from 1 meter to 4 meters and the table was turned from 0 degrees to 360 degrees to find the
   maximum reading.
5. The test receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold
   Mode.
6. If the emission level of the EUT in peak mode was 10 ㏈ lower than the limit specified, then testing could
   be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have
   10 ㏈ margin would be re-tested one by one using peak, quasi-peak or average method as specified and
   then reported in a data sheet.




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                       Page:     12      of       34


Note;

All channels were investigated for radiated spurious emissions. Only the radiated emissions of the
configuration that produced the worst case emissions are reported in this section.

1. Unwanted Emissions into Non-Restricted Frequency Bands

- The Reference Level Measurement refer to section 11.11.2
Set analyzer center frequency to DTS channel center frequency, SPAN ≥ 1.5 times the DTS bandwidth, the
RBW = 100 ㎑ and VBW ≥ 3ⅹRBW, Detector = Peak, Sweep time = Auto couple, Trace = Max hold.

- Unwanted Emissions Level Measurement refer to section 11.11.3
Set the center frequency and span to encompass frequency range to be measured, the RBW = 100 ㎑ and
VBW ≥ 3ⅹRBW, Detector = Peak, Sweep time = Auto couple, Trace = Max hold.

2. Unwanted Emissions into Restricted Frequency Bands

- Peak Power measurement procedure refer to section 11.12.2.4
Set RBW = as specified in Table 9, VBW ≥ 3 x RBW, Detector = Peak, Sweep time = auto, Trace = Max hold.

                                    Table 9– RBW as a function of frequency
                                         Frequency                 RBW
                                       9 ㎑ to 150 ㎑         200 ㎐ to 300 ㎐
                                      0.15 ㎒ to 30 ㎒          9 ㎑ to 10 ㎑
                                     30 ㎒ to 1 000 ㎒        100 ㎑ to 120 ㎑
                                         > 1 000 ㎒                 1 ㎒

If the peak – detected amplitude can be shown to comply with the average limit, then it is not necessary to
perform a separate average measurement.

-Average Power measurements procedure refer to section 11.12.2.5.2
The EUT shall be configured to operate at the maximum achievable duty cycle.
Measure the duty cycle D of the transmitter output signal as described in section 11.6.
Set RBW = 1 ㎒, VBW ≥ 3 x RBW, Detector = RMS, if span / (# of points in sweep) ≤ (RBW/2).
Satisfying this condition may require increasing the number of points in the sweep or reducing the span. If
this condition cannot be satisfied then the detector mode shall be set to peak.

Averaging type = power (i.e., RMS).
As an alternative the detector and averaging type may be set for linear voltage averaging.
Some instruments require linear display mode in order to use linear voltage averaging. Log or ㏈ averaging
shall not be used. Sweep time = auto, Perform a trace average of at least 100 traces.

A correction factor shall be added to the measurement results prior to comparing to the emission limit in
order to compute the emission level that would have been measured had the test been performed at 100
percent duty cycle. The correction factor is computed as follows:
 1) If power averaging (rms) mode was used in step f), then the applicable correction factor is [10 log(1 / D)],
   where D is the duty cycle.

3. Definition of DUT Axis.
Definition of the test orthogonal plan for EUT was described in the test setup photo.
The test orthogonal plan of EUT is Z – axis during radiation test.



The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                       Page:     13      of       34


2.3.3. Test Procedures for Conducted Spurious Emissions

All channels were investigated for radiated spurious emissions. Only the radiated emissions of the
configuration that produced the worst case emissions are reported in this section.

Per the guidance of ANSI C63.10-2013, section 11.11.1 & 11.11.2 & 11.11.3, the reference level for out of
band emissions is established from the plots of this section since the band edge emissions are measured
with a RBW of 100 ㎑. This reference level is then used as the limit in subsequent plots for out of band
spurious emissions shown in section 2.4.3. The limit for out of band spurious emission at the band edge is 20
㏈ below the fundamental emission level measured in a 100 ㎑ bandwidth.

1. Conducted Emissions at Band Edge
 - The Measurement refer to section 11.11.2
   Set the center frequency and span to encompass frequency range to be measured, the RBW = 100 ㎑
   and VBW ≥ 3 x RBW, Detector = Peak, Sweep time = Auto couple, Trace mode = Max hold, The trace was
   allowed to stabilize.

2. Conducted Spurious Emissions
 - The Measurement refer to section 11.11.3
   Start frequency was set to 9 ㎑ and stop frequency was set to 25 ㎓ (separated into two plots per
   channel), RBW = 1 ㎒, VBW ≥ 3 x RBW, Detector = Peak, Sweep time = Auto couple, Trace = Max hold,
   The trace was allowed to stabilize.

3. TDF function
 - For plots showing conducted spurious emissions from 9 ㎑ to 25 ㎓, all path loss of wide frequency
   range was investigated and compensated to spectrum analyzer as TDF function.
   So, the reading values shown in plots were final result.




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                                                             Page:                14                 of      34


2.4. Test Results

Ambient temperature                      : (23 ± 1) ℃
Relative humidity                        : 47         % R.H.

2.4.1. Radiated Spurious Emission below 1 000 ㎒

The frequency spectrum from 9 ㎑ to 1 000 ㎒ was investigated. All reading values are peak values.

              Radiated Emissions                       Ant               Correction Factors                             Total                                         Limit
Frequency                 Reading        Detect                           AF                AMP + CL                 Actual                           Limit                   Margin
                                                      Pol.
   (㎒)                     (㏈㎶)          Mode                            (㏈/m)                (㏈)                   (㏈㎶/m)                           (㏈㎶/m)                    (㏈)
     352.40                31.10         Peak           H                20.96               -23.88                    28.18                         46.00                    17.82

     441.44                31.60         Peak           V                22.07               -22.97                    30.70                         46.00                    15.30

     932.22                31.50         Peak           H                28.16               -21.69                    37.97                         46.00                     8.03

Remark;

1.     Spurious emissions for all channels were investigated and almost the same below 1 ㎓.
2.     Reported spurious emissions are in Middle channel as worst case among other channels.
3.     Radiated spurious emission measurement as below.
       (Actual = Reading + AF + AMP + CL)
4.     According to §15.31(o), emission levels are not report much lower than the limits by over 20 ㏈.

- Test plot

      Model                 :                                                    Standard                : FCC Part.15 Subpart C 3m
      Serial               :                                                     Remark1                 :
      Operator             :                                                     Remark2                 :
      AC Power             :                                                     Remark3                 :
      Temp,Humid           :                                                     Remark4                 :
             [dB(uV/m)]
                 100
                                                                                                                                        <FCC Subpart C>
                                                                                                                                                          Limit(PK)
                 90                                                                                                                                       Limit(AV)
                                                                                                                                        <New Data>
                 80                                                                                                                                       Spectrum(H,PK)
                                                                                                                                                          Spectrum(V,PK)
                 70                                                                                                                                       Suspected Item(H)
                                                                                                                                                          Suspected Item(V)
                 60
      Level




                 50

                 40

                 30

                 20

                 10

                  0
                 30.000         50.000      100.000                                            500.000                       1000.000
                                                             Frequency                                                         [MHz]




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807                                                     http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                                     Tel. +82 31 428 5700 / Fax. +82 31 427 2370                                                 A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                        Page:    15      of          34


2.4.2. Radiated Spurious Emission above 1 000 ㎒

The frequency spectrum above 1 000 ㎒ was investigated. All reading values are peak and average values.

Low Channel (2 402 ㎒)

       Radiated Emissions                  Ant.        Correction Factors                Total             Limit
Frequency       Reading        Detect               AF        AMP+CL          DF        Actual       Limit        Margin
                                           Pol.
   (㎒)           (㏈㎶)          Mode                (㏈/m)        (㏈)           (㏈)      (㏈㎶/m)       (㏈㎶/m)         (㏈)
 *2 310.00        39.31         Peak        V       28.54       -24.94         -         42.91       74.00         31.09

 *2 310.00        28.68       Average       V       28.54       -24.94       1.99        34.27       54.00         19.73

 *2 389.65        56.98         Peak        V       28.94       -24.80         -         61.12       74.00         12.88

 *2 389.13        33.23       Average       V       28.93       -24.81       1.99        39.34       54.00         14.66

 *2 390.00        56.65         Peak        V       28.94       -24.80         -         60.79       74.00         13.21

 *2 390.00        28.80       Average       V       28.94       -24.80       1.99        34.93       54.00         19.07


       Radiated Emissions                  Ant.        Correction Factors                Total             Limit
Frequency       Reading        Detect               AF        AMP+CL          DF        Actual       Limit        Margin
                                           Pol.
    (㎒)          (㏈㎶)          Mode                (㏈/m)        (㏈)           (㏈)      (㏈㎶/m)       (㏈㎶/m)         (㏈)
  Above           Not
                                  -          -         -           -           -            -          -             -
 1 000.00       detected

Middle Channel (2 440 ㎒)

       Radiated Emissions                  Ant.        Correction Factors                Total             Limit
Frequency       Reading        Detect               AF        AMP+CL          DF        Actual       Limit        Margin
                                           Pol.
    (㎒)          (㏈㎶)          Mode                (㏈/m)        (㏈)           (㏈)      (㏈㎶/m)       (㏈㎶/m)         (㏈)
  Above           Not
                                  -          -         -           -           -            -          -             -
 1 000.00       detected




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                         Tel. +82 31 428 5700 / Fax. +82 31 427 2370        A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                        Page:    16      of          34


High Channel (2 480 ㎒)

        Radiated Emissions                 Ant.        Correction Factors                Total             Limit
Frequency       Reading        Detect               AF        AMP+CL          DF        Actual       Limit        Margin
                                           Pol.
   (㎒)           (㏈㎶)          Mode                (㏈/m)        (㏈)           (㏈)      (㏈㎶/m)       (㏈㎶/m)         (㏈)
 *2 483.50        59.83         Peak        V       29.17       -24.67         -         64.33       74.00         9.67

 *2 483.50        34.82       Average       V       29.17       -24.67       1.99        41.31       54.00         12.69

 *2 483.81        59.50         Peak        V       29.17       -24.67         -         64.00       74.00         10.00

 *2 484.07        36.44       Average       V       29.17       -24.67       1.99        42.93       54.00         11.07

 *2 500.00        47.44         Peak        V       29.20       -24.66         -         51.98       74.00         22.02

 *2 500.00        28.40       Average       V       29.20       -24.66       1.99        34.93       54.00         19.07


        Radiated Emissions                 Ant.        Correction Factors                Total             Limit
Frequency       Reading        Detect               AF        AMP+CL          DF        Actual       Limit        Margin
                                           Pol.
    (㎒)          (㏈㎶)          Mode                (㏈/m)        (㏈)           (㏈)      (㏈㎶/m)       (㏈㎶/m)         (㏈)
  Above           Not
                                  -          -         -           -           -            -          -             -
 1 000.00       detected

Remarks;

1.   “*” means the restricted band.
                                                th
2.   Measuring frequencies from 1 ㎓ to the 10 harmonic of highest fundamental frequency.
3.   Radiated emissions measured in frequency above 1 000 ㎒ were made with an instrument using
     peak/average detector mode.
4.   Actual = Reading + AF + CL + (DF) or Reading + AF + AMP + CL + (DF).
5.   According to § 15.31(o), emission levels are not reported much lower than the limits by over 20 ㏈.
6.   The maximized peak measured value complies with the average limit, to perform an average
     measurement is unnecessary.




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                         Tel. +82 31 428 5700 / Fax. +82 31 427 2370        A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                       Page:     17      of       34


- Test plots

Low channel Band edge (Peak)




Low channel Band edge (Average)




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                       Page:     18      of       34


High channel Band edge (Peak)




High channel Band edge (Average)




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


Report Number: F690501/RF-RTL013933                                                        Page:     19      of       34


2.4.3. Plot of Conducted Spurious Emissions

Low Channel




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


Report Number: F690501/RF-RTL013933                                                        Page:     20      of       34




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                       Page:     21      of       34


Middle Channel




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


Report Number: F690501/RF-RTL013933                                                        Page:     22      of       34




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                       Page:     23      of       34


High Channel




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


Report Number: F690501/RF-RTL013933                                                        Page:     24      of       34




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                       Page:     25      of       34



3. 6 ㏈ Bandwidth
3.1. Test Setup


                                                                                                       Spectrum
        EUT                                          Attenuator
                                                                                                       Analyzer


3.2. Limit

According to §15.247(a)(2), systems using digital modulation techniques may operate in the 902-928 ㎒,
2 400-2 483.5 ㎒, and 5 725-5 850 ㎒ bands. The minimum 6 ㏈ bandwidth shall be at least 500 ㎑.

3.3. Test Procedure

The test follows section 11.8 DTS bandwidth of ANSI C63.10-2013.
Tests performed using section 11.8.1 Option 1.

- Option 1:
1. Set RBW to = 100 ㎑.
2. Set the video bandwidth (VBW) ≥ 3 ⅹ RBW.
3. Detector = Peak.
4. Trace mode = max hold.
5. Sweep = auto couple.
6. Allow the trace to stabilize.
7. Measure the maximum width of the emission that is constrained by the frequencies associated with the
   two outermost amplitude points (upper and lower frequencies) that are attenuated by 6 ㏈ relative to the
   maximum level measured in the fundamental emission.




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                       Page:     26      of       34


3.4. Test Results

Ambient temperature                : (23 ± 1) ℃
Relative humidity                  : 47     % R.H.

                                             Frequency                  6 ㏈ Bandwidth            Minimum Bandwidth
      Mode             Channel
                                                (㎒)                          (㎒)                        (㎑)

                            Low                 2 402                          0.749

     GFSK               Middle                  2 440                          0.749                       500

                            High                2 480                          0.749


- Test plots

Low Channel




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                       Page:     27      of       34


Middle Channel




High Channel




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                       Page:     28      of       34


4. Maximum Peak Conducted Output Power
4.1. Test Setup



         EUT                                         Attenuator                                     Power Sensor




                                                                                                    Test Note PC



4.2. Limit

According to §15.247(b)(3), for systems using digital modulation in the 902-928 ㎒, 2 400-2 483.5 ㎒, and 5
725-5 850 ㎒ bands: 1 Watt. As an alternative to a peak power measurement, compliance with the one Watt
limit can be based on a measurement of the maximum conducted output power. Maximum Conducted
Output Power is defined as the total transmit power delivered to all antennas and antenna elements
averaged across all symbols in the signaling alphabet when the transmitter is operating at its maximum
power control level. Power must be summed across all antennas and antenna elements. The average must
not include any time intervals during which the transmitter is off or is transmitting at a reduced power level. If
multiple modes of operation are possible (e.g., alternative modulation methods), the maximum conducted
output power is the highest total transmit power occurring in any mode.

According to §15.247(b)(4), the conducted output power limit specified in paragraph (b) of this section is
based on the use of antenna with directional gains that do not exceed 6 ㏈i. Except as shown in paragraph
(c) of this section, if transmitting antennas of directional gain greater than 6 ㏈i are used, the conducted
output power from the intentional radiator shall be reduced below the stated values in paragraph (b)(1), (b)(2),
and (b)(3) of this section, as appropriate, by the amount in ㏈ that the directional gain of the antenna
exceeds 6 ㏈i.




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                       Page:     29      of       34


4.3. Test Procedure
The test follows section 11.9.1.3 of ANSI C63.10-2013.

PKPM1 Peak-reading power meter method
- The maximum peak conducted output power may be measured using a broadband peak RF power meter.
The power meter shall have a video bandwidth that is greater than or equal to the DTS bandwidth and shall
utilize a fast-responding diode detector.

The test follows section 11.9.2.3.2 of ANSI C63.10-2013.

Method AVGPM-G (Measurement using a gated RF average-reading power meter)
- Alternatively, measurements may be performed using a wideband gated RF power meter provided that the
gate parameters are adjusted such that the power is measured only when the EUT is transmitting at its
maximum power control level. Since this measurement is made only during the ON time of the transmitter, no
duty cycle correction is required.

Test program: (S/W name: R&S Power Viewer, Version: 3.2.0)

1. Initially overall offset for attenuator and cable loss is measured per frequency.
2. Measured offset is inserted in test program in advance of measurement for output power.
3. Power for each frequency (channel) of device is investigated as final result.
4. Final result reported on this section from R&S power viewer program includes with several factors and test
   program shows only final result.




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                       Page:     30      of       34


4.4. Test Results

Ambient temperature            : (23 ± 1) ℃
Relative humidity              : 47      % R.H.

                                                         Average Power             Peak Power
                                    Frequency                                                               Limit
   Mode          Channel                                     Result                  Result
                                       (㎒)                                                                 (㏈ m)
                                                             (㏈ m)                   (㏈ m)

                    Low                2 402                   -2.76                   -2.24

  GFSK            Middle               2 440                   -2.49                   -1.90                  30

                    High               2 480                   -2.91                   -2.25


Remark;

Attenuator and cable offset was compensated in test program (R&S Power Viewer) before measuring.




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                       Page:     31      of       34


5. Power Spectral Density
5.1. Test Setup


                                                                                                       Spectrum
        EUT                                          Attenuator
                                                                                                       Analyzer


5.2. Limit
According to §15.247(e), for digitally modulated systems, the power spectral density conducted from the
intentional radiator to the antenna shall not be greater than 8 ㏈ m in any 3 ㎑ band during any time interval
of continuous transmission. This power spectral density shall be determined in accordance with the
provisions of paragraph (b) of this section. The same method of determining the conducted output power
shall be used to determine the power spectral density.

5.3. Test Procedure
The measurements are recorded using the PKPSD measurement procedure in section 11.10.2 of ANSI
C63.10-2013.

- This procedure shall be used if maximum peak conducted output power was used to demonstrate
compliance, and is optional if the maximum conducted (average) output power was used to demonstrate
compliance.

1. Set analyzer center frequency to DTS channel center frequency.
2. Set the span to 1.5 x DTS bandwidth.
3. Set the RBW to: 3 ㎑ ≤ RBW ≤ 100 ㎑.
4. Set the VBW ≥ 3 ⅹ RBW.
5. Detector = Peak.
6. Sweep time = auto couple.
7. Trace mode = max hold.
8. Allow trace to fully stabilize.
9. Use the peak marker function to determine the maximum amplitude level within the RBW.
10. If measured value exceeds limit, reduce RBW (no less than 3 ㎑) and repeat.




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                        Page:    32      of       34


5.4. Test Results

Ambient temperature            : (23 ± 1) ℃
Relative humidity              : 47      % R.H.

                                                      Frequency              Measured PSD           Maximum Limit
       Mode                   Channel
                                                         (㎒)                  (㏈ m/3 ㎑)               (㏈ m/3 ㎑)

                                 Low                     2 402                     -18.39

       GFSK                     Middle                   2 440                     -18.16                    8

                                 High                    2 480                     -18.35



- Test plots

Low Channel




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                       Page:     33      of       34


Middle Channel




High Channel




The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)


 Report Number: F690501/RF-RTL013933                                                       Page:     34      of       34


6. Antenna Requirement
6.1. Standard Applicable
For intentional device, according to FCC 47 CFR Section §15.203, an intentional radiator shall be designed
to ensure that no antenna other than that furnished by the responsible party shall be used with the device.
And according to FCC 47 CFR Section §15.247(b) if transmitting antennas of directional gain greater than 6
㏈ i are used, the power shall be reduced by the amount in ㏈ that the gain of the antenna exceeds 6 ㏈ i.

6.2. Antenna Connected Construction

Antenna used in this product is FPC antenna with gain of 1.80 ㏈ i.




                                          - End of the Test Report -
The results of this test report are effective only to the items tested. The SGS Korea is not responsible for the sampling,
the results of this test report apply to the sample as received. This test report cannot be reproduced, except in full,
without prior written permission of the Company. This test report does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory) 4, LS-ro 182beon-gil, Gunpo-si, Gyeonggi-do, Korea, 15807    http://www.sgsgroup.kr
RTT5041-19(2019.04.24)(1)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370         A4(210 mmⅹ297 mm)



Document Created: 2019-06-21 22:54:00