HAC_RF Appendix B

FCC ID: ZNFH790

Test Report

Download: PDF
FCCID_2745313

Test Laboratory: UL Verification Services Inc., SAR Lab 2                           Date: 7/20/2015

HAC-RF Emission
Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2540; ConvF(1, 1, 1); Calibrated: 8/26/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1259; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

Dipole E-Field measurement/835 MHz/Hearing Aid Compatibility Test at 15mm distance
(41x361x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 121.8 V/m; Power Drift = 0.08 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 125.1 V/m
Near-field category: M4 (AWF 0 dB)

                                          PMF scaled E-field
                                          Grid 1 M4 Grid 2 M4 Grid 3 M4
                                          123.2 V/m         125.1 V/m   121.0 V/m
                                          Grid 4 M4         Grid 5 M4   Grid 6 M4
                                          62.63 V/m         64.21 V/m   63.67 V/m
                                          Grid 7 M4         Grid 8 M4   Grid 9 M4
                                          98.24 V/m         99.96 V/m   98.83 V/m




                      0 dB = 125.1 V/m = 41.95 dBV/m



                                                                                                      Plot No. 1


Test Laboratory: UL Verification Services Inc., SAR Lab 2                           Date: 7/20/2015

HAC-RF Emission
Communication System: UID 0, CW; Frequency: 1880 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2540; ConvF(1, 1, 1); Calibrated: 8/26/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1259; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

Dipole E-Field measurement/1880 MHz/Hearing Aid Compatibility Test at 15mm
distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 129.9 V/m; Power Drift = -0.14 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 92.74 V/m
Near-field category: M3 (AWF 0 dB)

                                          PMF scaled E-field
                                          Grid 1 M3 Grid 2 M3 Grid 3 M3
                                          91.98 V/m         92.74 V/m   89.29 V/m
                                          Grid 4 M3         Grid 5 M3   Grid 6 M3
                                          68.98 V/m         70.51 V/m   70.22 V/m
                                          Grid 7 M3         Grid 8 M3   Grid 9 M3
                                          84.28 V/m         86.25 V/m   85.24 V/m




                      0 dB = 92.74 V/m = 39.35 dBV/m



                                                                                                      Plot No. 2


Test Laboratory: UL Verification Services Inc., SAR Lab 2                           Date: 7/20/2015

HAC-RF Emission
Communication System: UID 0, CW (0); Frequency: 2600 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2540; ConvF(1, 1, 1); Calibrated: 8/26/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1259; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

Dipole E-Field measurement/2600 MHz/Hearing Aid Compatibility Test at 15mm
distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 71.82 V/m; Power Drift = 0.07 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 88.29 V/m
Near-field category: M3 (AWF 0 dB)

                                          PMF scaled E-field
                                          Grid 1 M3 Grid 2 M3 Grid 3 M3
                                          87.44 V/m         88.29 V/m   86.34 V/m
                                          Grid 4 M3         Grid 5 M3   Grid 6 M3
                                          82.63 V/m         84.40 V/m   83.79 V/m
                                          Grid 7 M3         Grid 8 M3   Grid 9 M3
                                          85.92 V/m         87.49 V/m   86.20 V/m




                      0 dB = 88.29 V/m = 38.92 dBV/m



                                                                                                      Plot No. 3



Document Created: 2015-09-02 12:19:08
Document Modified: 2015-09-02 12:19:08

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC