HAC_T_Appendix E

FCC ID: ZNFH740

Test Report

Download: PDF
FCCID_2752881

Calibration Laboratory of                                            N/
                                                                           t

                                                                                                            S      Schweizerischer Kalibrierdienst




                                                                   /
                                                                  74
Schmid & Partner                                                  §ez                                       C      Service suisse d‘étalonnage
  Engineering AG                                                  SEEEMEAE                                         Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                         7         x                            S      Swiss Calibration Service
                                                                       Zohidubs®


Accredited by the Swiss Accreditation Service (SAS)                                                         Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client      UL CCS USA                                                                           Certificate No: ER3—2509_May15

CALIBERATION CERTIFICATE__
Object                                ER3DV6 — SN:2509


Calibration procedure(s)              QA CAL—O2.v8, QA CAL—25.v6
                                      Calibration procedure for E—field probes optimized for close near field
                                      evaluations in air

Calibration date:                     May 14, 2015
This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (St).
The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70% .


 Calibration Equipment used (M&TE critical for calibration)



 Primary Standards                   ID                                  Cal Date (Certificate No.)                   Scheduled Calibration
 Power meter E4419B                  GB41293874                          01—Apr—15 (No. 217—02128)                    Mar—16
 Power sensor E4412A                 MY41498087                          01—Apr—15 (No. 217—02128)                    Mar—16
 Reference 3 dB Attenuator           SN: $5054 (3c)                      01—Apr—15 (No. 217—02129)                    Mar—16
 Reference 20 dB Attenuator          SN: $5277 (20%)                     01—Apr—15 (No. 217—02132)                    Mar—16
 Reference 30 dB Attenuator          SN: $5129 (30b)                     01—Apr—15 (No. 217—02133)                    Mar—16
 Reference Probe ER3DV6              SN: 2328                            08—Oct—14 (No. ER3—2328_Oct14)               Oct—15
 DAE4                                SN: 789                              16—Mar—15 (No. DAE4—789_Mar15)              Mar—16


 Secondary Standards                 1D                                  Check Date (in house)                        Scheduled Check
 RF generator HP 8648C               US3642U01700                        4—Aug—99 (in house check Apr—13)             In house check: Apr—16
 Network Analyzer HP 8753E           US37390585                           18—0ct—01 (in house check Oct—14)           In house check: Oct—15

                                          Name                                     Function                             Signature
 Calibrated by:                        Jeton Kastrati                              Laboratory Technician    \<<mma>
                                                                                                           T eirgg
                                                                                                                                     (C/Z


 Approved by:                             Katjia Pokovic                           Technical Manager
                                                                                                                   easzez
                                                                                                                        Issued: May 19, 2015
 This calibration certificate shall not be reproduced except in full without written approval of the laboratory.




Certificate No: ER3—2509_May15                                         Page 1 of 11


Calibration Laboratory of                                                                     Schweizerischer Kalibrierdienst
Schmid & Partner                                                                              Service suisse d‘étalonnage
  Engineering AG                                                                              Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                  Swiss Calibration Service



Accredited by the Swiss Accreditation Service (SAS)                                       Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Glossary:
NORMx,y,z                    sensitivity in free space
DCP                          diode compression point
CF                           crest factor (1/duty_cycle) of the RF signal
A, B, C, D                   modulation dependent linearization parameters
Polarization o               q rotation around probe axis
Polarization 8               8 rotation around an axis that is in the plane normal to probe axis (at measurement center),
                             iie., 8 = 0 is normal to probe axis
Connector Angle              information used in DASY system to align probe sensor X to the robot coordinate system

Calibration is Performed According to the Following Standards:
    a)   IEEE Std 1309—2005, " IEEE Standard for calibration of electromagnetic field sensors and probes, excluding
         antennas, from 9 kHz to 40 GHz", December 2005
    b)   CTIA Test Plan for Hearing Aid Compatibility, April 2010.

Methods Applied and Interpretation of Parameters:
    «_   NORMx,y,z: Assessed for E—field polarization 8 = 0 for XY sensors and 8 = 90 for Z sensor (f < 900 MHz in
         TEM—cell; f > 1800 MHz: R22 waveguide).
    «    NORM(Px,y,z = NORMx,y,z * frequency_response (see Frequency Response Chart).
    «    DCPx,y,z:; DCP are numerical linearization parameters assessed based on the data of power sweep with CW
         signal (no uncertainty required). DCP does not depend on frequency nor media.
    e    PAR: PAR is the Peak to Average Ratio that is not calibrated but determined based on the signal
         characteristics
    e    Ax,y,z; Bx,y,z; Cx,y,z2; Dx,y,z; VRx,y,z: A, B, C, D are numerical linearization parameters assessed based on
         the data of power sweep for specific modulation signal. The parameters do not depend on frequency nor
         media. VR is the maximum calibration range expressed in RMS voltage across the diode.
    e    Spherical isotropy (3D deviation from isotropy): in a locally homogeneous field realized using an open
         waveguide setup.
    *    Sensor Offset: The sensor offset corresponds to the offset of virtual measurement center from the probe tip
         (on probe axis). No tolerance required.
    *    Connector Angle: The angle is assessed using the information gained by determining the NORMx (no
         uncertainty required).




Certificate No: ER3—2509_May15                                  Page 2 of 11


ER3SDV6 — SN:2509                                                               May 14, 2015




                     Probe ER3DV6

                                         SN:2509

                                  Manufactured:             November 2, 2009
                                  Calibrated:               May 14, 2015



                                 Calibrated for DASY/EASY Systems
                                    (Note: non—compatible with DASY2 system!)




Certificate No: ER3—2509_May15                     Page 3 of 11


ER3DVE6 — SN:2509                                                                                       May 14, 2015



DASY/EASY — Parameters of Probe: ER3DV6 — SN:25098

Basic Calibration Parameters
                                        Sensor X              Sensor Y               Sensor Z            Unc (k=2)
 Norm {uV/(V/m))                          1.99                     1.54                1.99              +101 %
 DCP (mV)"                               100.8                     99.9        _      104.6



Modulation Calibration Parameters
 UID     Communication System Name                         A            B      C        D        VR         Unc®
                                                          dB         dByuV             dB        mV         (k=2)
 0          CW                                     xX     0.0          0.0     1.0    0.00      186.6      +3.8 %
                                                   Y      0.0          0.0     1.0              196.4
                                                   Z      0.0          0.0     1.0              218.0
 10021—     GSM—FDD (TDMA, GMSK)                   x     25.54        99.5    28.5    9.39      132.0      +#1.7%
 DAB
                                                   Y¥    27.38        99.3    29.5              112.0
  _                                                Z      9.80        86.3    231               126.2
 10023—     GPRS—FDD (TDMA, GMSK, TN 0)            X     25.40        99.4    28.6    9.57      130.9      +1.9%
 DAB
                                                   Y¥    27.91        99.6    29.6              111.5
                                                   Z     19.32        98.2    27.3              123.5
 10024—     GPRS—FDD (TDMA, GMSK, TN 0—1)          x     33.89        99.8    26.2    6.56      107.1      +2.5 %
 DAB
                                                   Y¥    38.11        99.8    26.9              135.0
                                                   Z     28.06        99.7    25.3              109.6
 10027—     GPRS—FDD (TDMA, GMSK, TN 0—1—2)        X     42.55        99.5    24.3    4.80      1204       +2.7%
 DAB
                                                   Y     44.06        99.7    25.3              144.8
                                                   Z     47.43        99.7    22.8              125.9
 10028—     GPRS—FDD (TDMA, GMSK, TN 0—1—2—3)      x     47.43        99.7    23.4    3.55      125.5      +3.0 %
 DAB
                                                   Y     53.93        100.0   23.9              148.0
                                                   Z     44.71        99.8    22.4              136.3
 10030—     IEEE 802.15.1 Bluetooth (GFSK, DH1)    x     37.04        99.8    25.4    5.30      117.3      £2.5 %
 CAA
                                                   Y     41.30        99.9    26.1              146.1
                                                   7     33.83        99.6    24.0              121.9
 10061—     IEEE 802.11b WiFi 2.4 GHz (DSSS, 11    C      8.02        82.5    24.5    3.60      104.9      +1.2%
 CAB        Mbps)
                                                   y     8.68         81.0    23.3              116.8
                                                   Z     6.97         83.8    25.7              116.8
 10077—     IEEE 802.11g WiFi 2.4 GHz              xX    13.70        78.0    29.4    11.00      96.3      +3.0 %
 CAB        (DSSS/OFDM, 54 Mbps)
                                                   Y     15.92        80.8    30.3              119.2
                                                   Z     11.40        72.9    26.3              107.4
 10173—     LTE—TDD (SC—FDMA, 1 RB, 20 MHz,        xX    14.85        93.3    35.7    9.48      132.9      £3.5 %
 CAB        16—QAM)
                                                   Y¥    11.98        82.6    29.9              108.0
                                                   Z     1015         83.6    <1:1              140.9




Certificate No: ER3—2509_May15                      Page 4 of 11


ER3DVE —— SN:2509                                                                                                                 May 14, 2015

 10235—        LTE—TDD (SC—FDMA, 1 RB, 10 MHz,                    xX     12.23         86.3        32.1       9.48       133.3       £+2.2 %
 CAB           16—QAM)
                                                                  Y      11.71         81.9        29.5                  107.4
                                                                  Z      10.03         83.3        30.9                  140.6
 10238—        LTE—TDD (SC—FDMA, 1 RB, 15 MHz,                    X      12.23         86.4        32.1       9.48       133.2       £+2.5 %
 CAB           16—QAM)
                                                                  Y      11.78         82.1        29.6                  107.1
                                                                  Z      9.94          83.0        30.8                  140.3
 10295—        CDMA2000, RC1, SO3, 1/8th Rate 25 fr.              X      18.93         98.9        38.9       12.49      116.6       £4.1 %
 AAB
                                                                  Y      21.41         99.6        39.1                   97.2
                                                                  Z      15.98         99.7        40.3                   114.3



 The reported uncertainty of measurement is stated as the standard uncertainty of measurement
 multiplied by the coverage factor k=2, which for a normal distribution corresponds to a coverage
 probability of approximately 95%.


® Numerical linearization parameter: uncertainty not required.
£ Uncertainty is determined using the max. deviation from linear response applying rectangular distribution and is expressed for the square of the
field value.




Certificate No: ER3—2509_May 15                                    Page 5 of 11


ER3DVE6 — SN:2509                                                                                                                                                                                        May 14, 2015


                                                                                    Frequency Response of E—Field
                                                                                                (TEM—Cell:ifi110 EXX, Waveguide: R22)




                                           1.5   TTTTYETTTT 13 t Td




                                           1.3—                       ....v»----_-....»u.i.“n-... .---.«.“....i_....“....m.:..,”,,..é....n.
         Frequency response (normalized)




                                           1.2—




                                           1.0_1 in                     irkereamassesse




                                                                                                              i                     [   e —f.   f——f          £_f   _f   _1          {C_Jf__C__f_    j
                                                                                                              ]                     |                    |                     I                     |
                                                 0                                        500              1000                  1500                  2000                   2500                  3000
                                                                                                                                 # [MHz]
                                                                                 #                                  [#i                            [(#                                  [ +%
                                                                             TEM (0°)                             R2_2_(_(j)")                  TEM (90°)                            R22_(9}0")
                                                                                  Uncertainty of Frequency Response of E—field: £ 6.3% (k=2)




Certificate No: ER3—2509_May15                                                                                              Page 6 of 11


ER3DVE6 — SN:2509                                                                                                                                                         May 14, 2015



                                                    Receiving Pattern (¢), 9 = 0°

                          f=600 MHz,TEM,0°                                                                       £=2500 MHz,R22,0°
                                                  9D
                                                   fevage                                                                               _3ag
                                                                                                                                —~%>




                   135                                                       45                            135.        *                                   *        45

                            £:                                    8ex

                             %                                     4
                                    ®             *I                               *
                                                                                             it                                          *>                                ®,
                                                                                         |                                                                                     j
          18                             *             *                           6   130                                          o @ br
                                                                                                                                        s                                      €;
                                              h dz               o4    os     o8         |                                                             o4      06    08
               &                                  14         ®                     4         w                                              k                              &
                                s                                  %
                                                                                                                   *            *



                                                                                                                   .
                   225 ~.                                                    315                           225         *                                   *    w 315

                                        —»*   "         #                                                                  Trw: Ferr it          x
                                              270                                                                                        270
             ®                      %                        &
           Tot                      X                        Y¥                        Tot                                 X                                                   Z




                                                  Receiving Pattern {¢6), 8 = 90°

                         f=600 MHz,TEM,90°                                                                   f=2500 MHz,R22,90°
                                                  90
                                                                                                                                    gamaraiibscones.
                            _       x‘/.l—m‘-* *«

                   136,                                                     "45                            135 *                                                     45
                                                                                                       /
                                                                                                      /{

                                                                                                  [                                                                        *




           180
              |
                                              .
                                                        o2        o4   os     o8       tA
                                                                                             |                                           ® o2          o4      o6     08




                   225                                                       15                            2;5 %                                                    315

                                    “\M.—_‘,.
                                    —             27                                                                                ~~3g
               ®                    ®                        e                           a                                  ®                          &                           #
            Tot                     X                        Y                          Tot                                 X                          Y                           Z




Certificate No: ER3—2509_May15


ER3DVE6 — SN:2509                                                                                                                                                                                                                         May 14, 2015


                                                                  Receiving Pattern (¢), 8 = 0°



             s i e s 1 e on ce oo n en ns on en e e ies on cevne enc oe e o Tt e BL .. iL 0 0 M BN 0 m stie _ ons | emmin _ mom s

      o
      E__;
                 P
             00:“*““?*%:,!‘235;1:_
                                                                       f                                           &
      o0         [             f                                       f                                           f                                                                                    f                             f
             moo3....s.M...PnearsJnoonBjsn...s8.nnefi=d
                 [ Oe                    L     p     n        j                L0       L           _|                 oc          ut       ;              Eo_       pouio       t    EdE   o   es          _E       p       L             Lo
                             —150                             100                                                 «o                                  d                          50                 160                              150
                                                                                                                       C                    Roll [°]                                                                         .
                                            *                                                                        &                                                   a                                              [®
                                       10‘?17",-1.
                                              MHz                                                                SO%M'I—iz                                           18(RTRJH2                                       25ITSTJHZ

                                                         Uncertainty of Axial Isotropy Assessment: £ 0.5% (k=2)




                                                              Receiving Pattern (¢), 9 = 90
                                                                                                m            ®                                                                        wun           0




             BBefrrrerenenenfen Aeveae c nereoomdeoareenemneerceneeanedcaveesc es te mssncuee ieesBen t aenaus esseaeneuSNouent cenebenesien dn91Pheverecous
      g     —       i           i                                                                                                             :
      'g 00-_-0=i:'~—l»—4—0—‘0-*#-‘                                                             —#                : ~Gef—#—$— $i~g fi:.*.:%fi:@fiw-@gs-.—wn&
      i5          §                j                                       i                                                                  :



                  C      L                1_   +         L        1                 1       I            l                 1   L        T       T      '   N     1   1       1        L1    1   L                1       1   T   I         1    |

                             —150                                     —100                                        80                                   6                         50                 100                              180
                                                                                                                                                    Roll ["]
                                       100 MHz                                                                   £00 MHz                                                 1800 MHz                                        2500 MHz


                                                             Uncertainty of Axial Isotropy Assessment: £ 0.5% (k=2)




Certificate No: ER3—2509_May15                                                                                                 Page 8 of 11


ER3DV6 — SN:2509                                                                                                                          May 14, 2015




                                           Dynamic Range f(E—field)
                                                   (TEM cell , f = 900 MHz)


                        10§Aemeepe=}




                         105




                   T JGHe e
                   &
                   G
                   &
                   .
                   95

                   a 10%——
                   &




                         102_




                         101 oizser



                               10°                          101                                                   10                10°
                                                                       E total [V/m]
                                                 al
                                            not compensated                                                       compensated




                               2                                                                                                i
                                                                                                                                |


                               1   oi)                                       cearetytrey 2


                        m |
                        E..        |
                                                                                 ‘
                                                             caresians Qz.&{—,e‘!;                                ressoasls
                        3      °mm                                                                                ns
                        & [   wfi
                                   L
                                                            efo n enc occ 50e                                dueciads
                                                                                                              f
                                                                                                                  *
                              _2   f                  Pod                        !           }   I   i   ?



                                   109                      101                                              102
                                                                      E total [V/m|
                                                  _*
                                             not compensated                                                 compensated


                                         Uncertainty of Linearity Assessment: £ 0.6% (k=2)




Certificate No: ER3—2509_May15                                    Page 9 of 11


ER3DV6 — SN:2509                                                                                  May 14, 2015


                                 Deviation from Isotropy in Air
                                               Error (6, 9), f = 900 MHz




                       z
                       9
                       oa
                       &.




                        —1.0     —0.8   —0.6   —0.4   —0.2   0.0    0.2   0.4   0.8   0.8   1.0

                            Uncertainty of Spherical Isotropy Assessment: £ 2.6% (k=2)




Certificate No: ER3—2509_May15                          Page 10 of 11


ER3DVE6 — SN:2509                                          May 14, 2015



DASY/EASY — Parameters of Probe: ER3DVG6 — SN:2509

Other Probe Parameters
 Sensor Arrangement                                        Rectangular
 Connector Angle (°)                                              66.9
 Mechanical Surface Detection Mode                            enabled
 Optical Surface Detection Mode                               disabled
 Probe Overall Length                                         337 mm
 Probe Body Diameter                                           10 mm
 Tip Length                                                    10 mm
 Tip Diameter                                                   8 mm
 Probe Tip to Sensor X Calibration Point                       2.5 mm
 Probe Tip to Sensor Y Calibration Point                       2.5 mm
 Probe Tip to Sensor Z Calibration Point                       2.5 mm




Certificate No: ER3—2509_May15             Page 11 of 11