SAR_Appendix C

FCC ID: ZNFH740

RF Exposure Info

Download: PDF
FCCID_2752855

Test Laboratory: UL Verification Services Inc., SAR Lab 5                    Date/Time: 8/4/2015 12:13:31 AM

GSM 850

Frequency: 836.6 MHz; Duty Cycle: 1:8.00018;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.888 S/m; εr = 40.353; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1239; Calibrated: 4/16/2015
- Probe: EX3DV4 - SN3773; ConvF(8.48, 8.48, 8.48); Calibrated: 4/22/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: TWIN SAM v5.0; Type: QD000P40CD; Serial: TP:1829

RHS/Touch_GSM Voice_ch 190/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.263 W/kg

RHS/Touch_GSM Voice_ch 190/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 17.48 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 0.296 W/kg
SAR(1 g) = 0.239 W/kg; SAR(10 g) = 0.183 W/kg
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.262 W/kg




                      0 dB = 0.262 W/kg = -5.82 dBW/kg




                                                                                                                Plot No. 1


Test Laboratory: UL Verification Services Inc., SAR Lab 5                    Date/Time: 8/4/2015 12:28:55 AM

GSM 850

Frequency: 836.6 MHz; Duty Cycle: 1:4.00037;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.888 S/m; εr = 40.353; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1239; Calibrated: 4/16/2015
- Probe: EX3DV4 - SN3773; ConvF(8.48, 8.48, 8.48); Calibrated: 4/22/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: TWIN SAM v5.0; Type: QD000P40CD; Serial: TP:1829

RHS/Touch_GPRS 2 Slots_ch 190/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.392 W/kg

RHS/Touch_GPRS 2 Slots_ch 190/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 21.04 V/m; Power Drift = 0.03 dB
Peak SAR (extrapolated) = 0.438 W/kg
SAR(1 g) = 0.352 W/kg; SAR(10 g) = 0.270 W/kg
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.391 W/kg




                      0 dB = 0.392 W/kg = -4.07 dBW/kg




                                                                                                                Plot No. 2


Test Laboratory: UL Verification Services Inc., SAR Lab 5                   Date/Time: 8/3/2015 8:09:43 PM

GSM 850

Frequency: 836.6 MHz; Duty Cycle: 1:8.00018;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 1.005 S/m; εr = 52.738; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1239; Calibrated: 4/16/2015
- Probe: EX3DV4 - SN3773; ConvF(8.26, 8.26, 8.26); Calibrated: 4/22/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: ELI v5.0 (B); Type: QDOVA001BB; Serial: 1118

Rear/GSM Voice only_ch 190/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.461 W/kg

Rear/GSM Voice only_ch 190/Zoom Scan (6x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 22.03 V/m; Power Drift = -0.03 dB
Peak SAR (extrapolated) = 0.648 W/kg
SAR(1 g) = 0.375 W/kg; SAR(10 g) = 0.216 W/kg
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.492 W/kg




                      0 dB = 0.492 W/kg = -3.08 dBW/kg




                                                                                                             Plot No. 3


Test Laboratory: UL Verification Services Inc., SAR Lab 5                    Date/Time: 8/3/2015 7:49:29 PM

GSM 850

Frequency: 836.6 MHz; Duty Cycle: 1:4.00037;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 1.005 S/m; εr = 52.738; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1239; Calibrated: 4/16/2015
- Probe: EX3DV4 - SN3773; ConvF(8.26, 8.26, 8.26); Calibrated: 4/22/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 (B); Type: QDOVA001BB; Serial: 1118

Rear/GPRS 2 slots_ch 190/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.728 W/kg

Rear/GPRS 2 slots_ch 190/Zoom Scan (6x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 27.48 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 1.03 W/kg
SAR(1 g) = 0.588 W/kg; SAR(10 g) = 0.339 W/kg
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.770 W/kg




                      0 dB = 0.770 W/kg = -1.14 dBW/kg




                                                                                                                Plot No. 4


Test Laboratory: UL Verification Services Inc., SAR Lab 3                    Date/Time: 8/4/2015 12:56:40 PM

GSM 1900

Frequency: 1880 MHz; Duty Cycle: 1:8.00018;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 1880 MHz; σ = 1.363 S/m; εr = 38.664; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/16/2015
- Probe: EX3DV4 - SN3749; ConvF(7.34, 7.34, 7.34); Calibrated: 1/26/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM with CRP; Type: SAM;

LHS/Touch_GSM Voice_ch 661/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.232 W/kg

LHS/Touch_GSM Voice_ch 661/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 12.91 V/m; Power Drift = 0.10 dB
Peak SAR (extrapolated) = 0.313 W/kg
SAR(1 g) = 0.204 W/kg; SAR(10 g) = 0.125 W/kg
Maximum value of SAR (measured) = 0.246 W/kg




                      0 dB = 0.246 W/kg = -6.09 dBW/kg




                                                                                                               Plot No. 5


Test Laboratory: UL Verification Services Inc., SAR Lab 3                   Date/Time: 8/4/2015 2:47:00 PM

GSM 1900

Frequency: 1880 MHz; Duty Cycle: 1:4.00037;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 1880 MHz; σ = 1.363 S/m; εr = 38.664; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/16/2015
- Probe: EX3DV4 - SN3749; ConvF(7.34, 7.34, 7.34); Calibrated: 1/26/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: SAM with CRP; Type: SAM;

LHS/Touch_GPRS 2 Slots_ch 661/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.308 W/kg

LHS/Touch_GPRS 2 Slots_ch 661/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 15.01 V/m; Power Drift = 0.06 dB
Peak SAR (extrapolated) = 0.441 W/kg
SAR(1 g) = 0.284 W/kg; SAR(10 g) = 0.174 W/kg
Maximum value of SAR (measured) = 0.351 W/kg




                      0 dB = 0.351 W/kg = -4.55 dBW/kg




                                                                                                             Plot No. 6


Test Laboratory: UL Verification Services Inc., SAR Lab 3                    Date/Time: 8/4/2015 3:26:17 PM

GSM 1900

Frequency: 1880 MHz; Duty Cycle: 1:8.00018;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 1880 MHz; σ = 1.479 S/m; εr = 51.097; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/16/2015
- Probe: EX3DV4 - SN3749; ConvF(7.09, 7.09, 7.09); Calibrated: 1/26/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI-B v5.0; Type: QDOVA001BB; Serial: 1215

Rear/GSM Voice only_ch 661/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.284 W/kg

Rear/GSM Voice only_ch 661/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 14.01 V/m; Power Drift = 0.09 dB
Peak SAR (extrapolated) = 0.397 W/kg
SAR(1 g) = 0.226 W/kg; SAR(10 g) = 0.127 W/kg
Maximum value of SAR (measured) = 0.294 W/kg




                      0 dB = 0.294 W/kg = -5.32 dBW/kg




                                                                                                               Plot No. 7


Test Laboratory: UL Verification Services Inc., SAR Lab 3                   Date/Time: 8/4/2015 3:48:12 PM

GSM 1900

Frequency: 1880 MHz; Duty Cycle: 1:4.00037;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 1880 MHz; σ = 1.479 S/m; εr = 51.097; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/16/2015
- Probe: EX3DV4 - SN3749; ConvF(7.09, 7.09, 7.09); Calibrated: 1/26/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: ELI-B v5.0; Type: QDOVA001BB; Serial: 1215

Rear/GPRS 2 slots_ch 661/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.410 W/kg

Rear/GPRS 2 slots_ch 661/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 16.65 V/m; Power Drift = 0.06 dB
Peak SAR (extrapolated) = 0.574 W/kg
SAR(1 g) = 0.327 W/kg; SAR(10 g) = 0.184 W/kg
Maximum value of SAR (measured) = 0.428 W/kg




                      0 dB = 0.428 W/kg = -3.69 dBW/kg




                                                                                                             Plot No. 8


Test Laboratory: UL Verification Services Inc., SAR Lab 3                    Date/Time: 8/4/2015 9:13:20 AM

WCDMA Band II

Frequency: 1880 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 1880 MHz; σ = 1.363 S/m; εr = 38.664; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/16/2015
- Probe: EX3DV4 - SN3749; ConvF(7.34, 7.34, 7.34); Calibrated: 1/26/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM with CRP; Type: SAM;

LHS/Touch_Rel. 99 RMC 12.2kbps_ch 9400/Area Scan (9x13x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 0.738 W/kg

LHS/Touch_Rel. 99 RMC 12.2kbps_ch 9400/Zoom Scan (5x5x7)/Cube 0: Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 23.12 V/m; Power Drift = 0.07 dB
Peak SAR (extrapolated) = 1.02 W/kg
SAR(1 g) = 0.657 W/kg; SAR(10 g) = 0.400 W/kg
Maximum value of SAR (measured) = 0.808 W/kg




                      0 dB = 0.808 W/kg = -0.93 dBW/kg




                                                                                                               Plot No. 9


Test Laboratory: UL Verification Services Inc., SAR Lab 3                    Date/Time: 8/4/2015 9:50:38 AM

WCDMA Band II

Frequency: 1880 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 1880 MHz; σ = 1.479 S/m; εr = 51.097; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/16/2015
- Probe: EX3DV4 - SN3749; ConvF(7.09, 7.09, 7.09); Calibrated: 1/26/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI-B v5.0; Type: QDOVA001BB; Serial: 1215

Rear/Rel. 99 RMC 12.2kbps_ch 9400/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.822 W/kg

Rear/Rel. 99 RMC 12.2kbps_ch 9400/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 23.82 V/m; Power Drift = -0.07 dB
Peak SAR (extrapolated) = 1.22 W/kg
SAR(1 g) = 0.691 W/kg; SAR(10 g) = 0.391 W/kg
Maximum value of SAR (measured) = 0.897 W/kg




                      0 dB = 0.897 W/kg = -0.47 dBW/kg




                                                                                                               Plot No. 10


Test Laboratory: UL Verification Services Inc., SAR Lab 5                    Date/Time: 8/3/2015 3:35:32 PM

WCDMA Band V

Frequency: 836.6 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.888 S/m; εr = 40.353; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1239; Calibrated: 4/16/2015
- Probe: EX3DV4 - SN3773; ConvF(8.48, 8.48, 8.48); Calibrated: 4/22/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: TWIN SAM v5.0; Type: QD000P40CD; Serial: TP:1829

RHS/Touch_Rel. 99 RMC 12.2kbps_ch 4183/Area Scan (9x13x1): Measurement grid: dx=15mm,
dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.333 W/kg

RHS/Touch_Rel. 99 RMC 12.2kbps_ch 4183/Zoom Scan (5x5x7)/Cube 0: Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 19.53 V/m; Power Drift = 0.07 dB
Peak SAR (extrapolated) = 0.377 W/kg
SAR(1 g) = 0.302 W/kg; SAR(10 g) = 0.231 W/kg
Info: Interpolated medium parameters used for SAR evaluation.




                      0 dB = 0.333 W/kg = -4.78 dBW/kg




                                                                                                               Plot No. 11


Test Laboratory: UL Verification Services Inc., SAR Lab 5                    Date/Time: 8/3/2015 4:57:21 PM

WCDMA Band V

Frequency: 836.6 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 1.005 S/m; εr = 52.738; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1239; Calibrated: 4/16/2015
- Probe: EX3DV4 - SN3773; ConvF(8.26, 8.26, 8.26); Calibrated: 4/22/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 (B); Type: QDOVA001BB; Serial: 1118

Rear/Rel. 99 RMC 12.2kbps_ch 4183/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.672 W/kg

Rear/Rel. 99 RMC 12.2kbps_ch 4183/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 26.42 V/m; Power Drift = 0.00 dB
Peak SAR (extrapolated) = 0.887 W/kg
SAR(1 g) = 0.510 W/kg; SAR(10 g) = 0.293 W/kg
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.667 W/kg




                      0 dB = 0.667 W/kg = -1.76 dBW/kg




                                                                                                               Plot No. 12


Test Laboratory: UL Verification Services Inc., SAR Lab 3                    Date/Time: 8/3/2015 5:10:29 PM

LTE Band 2

Frequency: 1880 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 1880 MHz; σ = 1.363 S/m; εr = 38.664; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/16/2015
- Probe: EX3DV4 - SN3749; ConvF(7.34, 7.34, 7.34); Calibrated: 1/26/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM with CRP; Type: SAM;

LHS/Touch_QPSK_RB 1/0__ch 18900/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.684 W/kg

LHS/Touch_QPSK_RB 1/0__ch 18900/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 22.19 V/m; Power Drift = 0.06 dB
Peak SAR (extrapolated) = 0.927 W/kg
SAR(1 g) = 0.603 W/kg; SAR(10 g) = 0.371 W/kg
Maximum value of SAR (measured) = 0.734 W/kg




                      0 dB = 0.734 W/kg = -1.34 dBW/kg




                                                                                                               Plot No. 13


Test Laboratory: UL Verification Services Inc., SAR Lab 3                    Date/Time: 8/3/2015 9:49:11 PM

LTE Band 2

Frequency: 1900 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 1900 MHz; σ = 1.511 S/m; εr = 50.977; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/16/2015
- Probe: EX3DV4 - SN3749; ConvF(7.09, 7.09, 7.09); Calibrated: 1/26/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI-B v5.0; Type: QDOVA001BB; Serial: 1215

Rear/QPSK RB 1/49 ch 19100/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 1.11 W/kg

Rear/QPSK RB 1/49 ch 19100/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 27.41 V/m; Power Drift = -0.08 dB
Peak SAR (extrapolated) = 1.73 W/kg
SAR(1 g) = 0.951 W/kg; SAR(10 g) = 0.524 W/kg
Maximum value of SAR (measured) = 1.26 W/kg




                      0 dB = 1.26 W/kg = 1.00 dBW/kg




                                                                                                               Plot No. 14


Test Laboratory: UL Verification Services Inc., SAR Lab 2                    Date/Time: 8/3/2015 1:09:00 PM

LTE Band 4

Frequency: 1732.5 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                 3
Medium parameters used (interpolated): f = 1732.5 MHz; σ = 1.312 S/m; εr = 38.581; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 1/14/2015
- Probe: EX3DV4 - SN3990; ConvF(8.7, 8.7, 8.7); Calibrated: 3/18/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM with CRP; Type: SAM;

LHS/Touch_QPSK RB 1,0_ch 20175/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.792 W/kg

LHS/Touch_QPSK RB 1,0_ch 20175/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 25.511 V/m; Power Drift = 0.03 dB
Peak SAR (extrapolated) = 0.983 W/kg
SAR(1 g) = 0.667 W/kg; SAR(10 g) = 0.428 W/kg
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.785 W/kg




                      0 dB = 0.785 W/kg = -1.05 dBW/kg




                                                                                                               Plot No. 15


Test Laboratory: UL Verification Services Inc., SAR Lab 2                    Date/Time: 8/3/2015 5:01:38 PM

LTE Band 4

Frequency: 1732.5 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                 3
Medium parameters used (interpolated): f = 1732.5 MHz; σ = 1.312 S/m; εr = 38.581; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 1/14/2015
- Probe: EX3DV4 - SN3990; ConvF(8.7, 8.7, 8.7); Calibrated: 3/18/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI A v5.0; Type: QDOVA002AA; Serial: S/n:1198

Rear/QPSK RB 1,0 Ch 20175/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.773 W/kg

Rear/QPSK RB 1,0 Ch 20175/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 25.248 V/m; Power Drift = 0.13 dB
Peak SAR (extrapolated) = 1.23 W/kg
SAR(1 g) = 0.733 W/kg; SAR(10 g) = 0.447 W/kg
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.926 W/kg




                      0 dB = 0.926 W/kg = -0.33 dBW/kg




                                                                                                               Plot No. 16


Test Laboratory: UL Verification Services Inc., SAR Lab 5                    Date/Time: 8/4/2015 8:53:30 AM

LTE Band 5

Frequency: 836.5 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                3
Medium parameters used (interpolated): f = 836.5 MHz; σ = 0.888 S/m; εr = 40.355; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1239; Calibrated: 4/16/2015
- Probe: EX3DV4 - SN3773; ConvF(8.48, 8.48, 8.48); Calibrated: 4/22/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: TWIN SAM v5.0; Type: QD000P40CD; Serial: TP:1829

RHS/Touch_QPSK Ch 20525 RB 1/49/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.344 W/kg

RHS/Touch_QPSK Ch 20525 RB 1/49/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 19.78 V/m; Power Drift = -0.10 dB
Peak SAR (extrapolated) = 0.394 W/kg
SAR(1 g) = 0.313 W/kg; SAR(10 g) = 0.237 W/kg
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.343 W/kg




                      0 dB = 0.343 W/kg = -4.65 dBW/kg




                                                                                                               Plot No. 17


Test Laboratory: UL Verification Services Inc., SAR Lab 5                    Date/Time: 8/4/2015 2:51:27 PM

LTE Band 5

Frequency: 836.5 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                3
Medium parameters used (interpolated): f = 836.5 MHz; σ = 1.005 S/m; εr = 52.737; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1239; Calibrated: 4/16/2015
- Probe: EX3DV4 - SN3773; ConvF(8.26, 8.26, 8.26); Calibrated: 4/22/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 (B); Type: QDOVA001BB; Serial: 1118

Rear/QPSK Ch 20525 RB 1/49/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.686 W/kg

Rear/QPSK Ch 20525 RB 1/49/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 26.37 V/m; Power Drift = 0.10 dB
Peak SAR (extrapolated) = 0.929 W/kg
SAR(1 g) = 0.533 W/kg; SAR(10 g) = 0.308 W/kg
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.701 W/kg




                      0 dB = 0.701 W/kg = -1.54 dBW/kg




                                                                                                               Plot No. 18


Test Laboratory: UL Verification Services Inc., SAR Lab 2                    Date/Time: 8/3/2015 11:42:05 PM

LTE Band 12

Frequency: 707.5 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                3
Medium parameters used (interpolated): f = 707.5 MHz; σ = 0.884 S/m; εr = 41.709; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 1/14/2015
- Probe: EX3DV4 - SN3990; ConvF(10.45, 10.45, 10.45); Calibrated: 3/18/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM with CRP; Type: SAM;

RHS/Touch_QPSK RB 1/49_ch 23095/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.230 W/kg

RHS/Touch_QPSK RB 1/49_ch 23095/Zoom Scan (6x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 16.361 V/m; Power Drift = 0.08 dB
Peak SAR (extrapolated) = 0.277 W/kg
SAR(1 g) = 0.226 W/kg; SAR(10 g) = 0.178 W/kg
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.252 W/kg




                      0 dB = 0.252 W/kg = -5.99 dBW/kg




                                                                                                               Plot No. 19


Test Laboratory: UL Verification Services Inc., SAR Lab 2                    Date/Time: 8/4/2015 11:15:08 AM

LTE Band 12

Frequency: 707.5 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                               3
Medium parameters used (interpolated): f = 707.5 MHz; σ = 0.925 S/m; εr = 53.93; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 1/14/2015
- Probe: EX3DV4 - SN3990; ConvF(10.09, 10.09, 10.09); Calibrated: 3/18/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI B v4.0; Type: QDOVA002AA; Serial: 1196

Rear/QPSK RB 1/49_ch 23095/Area Scan (9x14x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.455 W/kg

Rear/QPSK RB 1/49_ch 23095/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 17.321 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 0.508 W/kg
SAR(1 g) = 0.421 W/kg; SAR(10 g) = 0.329 W/kg
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.466 W/kg

Rear/QPSK RB 1/49_ch 23095/Zoom Scan 2 (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 17.321 V/m; Power Drift = -0.14 dB
Peak SAR (extrapolated) = 0.571 W/kg
SAR(1 g) = 0.351 W/kg; SAR(10 g) = 0.229 W/kg
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.440 W/kg




                      0 dB = 0.440 W/kg = -3.57 dBW/kg




                                                                                                               Plot No. 20


Test Laboratory: UL Verification Services Inc., SAR Lab 2                    Date/Time: 8/4/2015 4:11:45 PM

LTE Band 12

Frequency: 707.5 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                               3
Medium parameters used (interpolated): f = 707.5 MHz; σ = 0.925 S/m; εr = 53.93; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 1/14/2015
- Probe: EX3DV4 - SN3990; ConvF(10.09, 10.09, 10.09); Calibrated: 3/18/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI B v4.0; Type: QDOVA002AA; Serial: 1196

Edge 2/QPSK RB 1/49_ch 23095/Area Scan (7x14x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.556 W/kg

Edge 2/QPSK RB 1/49_ch 23095/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 24.982 V/m; Power Drift = -0.05 dB
Peak SAR (extrapolated) = 0.662 W/kg
SAR(1 g) = 0.484 W/kg; SAR(10 g) = 0.342 W/kg
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.568 W/kg




                      0 dB = 0.568 W/kg = -2.46 dBW/kg




                                                                                                               Plot No. 21


Test Laboratory: UL Verification Services Inc., SAR Lab 1                    Date/Time: 8/4/2015 11:36:10 PM

LTE Band 30

Frequency: 2310 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 2310 MHz; σ = 1.726 S/m; εr = 37.865; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1352; Calibrated: 11/7/2014
- Probe: EX3DV4 - SN7356; ConvF(8.23, 8.23, 8.23); Calibrated: 4/22/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM; Type: QD000P40CD; Serial: TP 1751

LHS/Touch_QPSK RB 1/0 ch_27710/Area Scan (10x15x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.336 W/kg

LHS/Touch_QPSK RB 1/0 ch_27710/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 13.801 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 0.451 W/kg
SAR(1 g) = 0.259 W/kg; SAR(10 g) = 0.142 W/kg
Maximum value of SAR (measured) = 0.341 W/kg




                      0 dB = 0.341 W/kg = -4.67 dBW/kg




                                                                                                               Plot No. 22


Test Laboratory: UL Verification Services Inc., SAR Lab 1                    Date/Time: 8/5/2015 10:21:22 AM

LTE Band 30

Frequency: 2310 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 2310 MHz; σ = 1.878 S/m; εr = 52.449; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1352; Calibrated: 11/7/2014
- Probe: EX3DV4 - SN7356; ConvF(7.83, 7.83, 7.83); Calibrated: 4/22/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI-B v5.0; Type: QDOVA002AA; Serial: TP:1195

Front/QPSK 1/0_ch 27710/Area Scan (9x16x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.302 W/kg

Front/QPSK 1/0_ch 27710/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 12.707 V/m; Power Drift = 0.10 dB
Peak SAR (extrapolated) = 0.455 W/kg
SAR(1 g) = 0.237 W/kg; SAR(10 g) = 0.130 W/kg
Maximum value of SAR (measured) = 0.315 W/kg




                      0 dB = 0.315 W/kg = -5.02 dBW/kg




                                                                                                               Plot No. 23


Test Laboratory: UL Verification Services Inc., SAR Lab 1                    Date/Time: 8/5/2015 1:26:01 PM

WiFi 2.4GHz

Frequency: 2437 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                              3
Medium parameters used (interpolated): f = 2437 MHz; σ = 1.86 S/m; εr = 37.319; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1352; Calibrated: 11/7/2014
- Probe: EX3DV4 - SN7356; ConvF(7.89, 7.89, 7.89); Calibrated: 4/22/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM; Type: QD000P40CD; Serial: TP 1751

LHS/Touch_802.11b_ch 6/Core 0/Area Scan (10x17x1): Measurement grid: dx=12mm, dy=12mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.596 W/kg

LHS/Touch_802.11b_ch 6/Core 0/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 18.654 V/m; Power Drift = -0.15 dB
Peak SAR (extrapolated) = 1.21 W/kg
SAR(1 g) = 0.523 W/kg; SAR(10 g) = 0.239 W/kg
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.768 W/kg




                      0 dB = 0.768 W/kg = -1.15 dBW/kg




                                                                                                               Plot No. 24


Test Laboratory: UL Verification Services Inc., SAR Lab 1                    Date/Time: 8/5/2015 3:35:39 PM

WiFi 2.4GHz

Frequency: 2437 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                               3
Medium parameters used (interpolated): f = 2437 MHz; σ = 2.019 S/m; εr = 52.037; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1352; Calibrated: 11/7/2014
- Probe: EX3DV4 - SN7356; ConvF(7.54, 7.54, 7.54); Calibrated: 4/22/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI-B v5.0; Type: QDOVA002AA; Serial: TP:1195

Rear/802.11b_ch 6/Area Scan (11x16x1): Measurement grid: dx=12mm, dy=12mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.324 W/kg

Rear/802.11b_ch 6/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value =12.95 V/m ; Power Drift = -0.05 dB
Peak SAR (extrapolated) = 0.603 W/kg
SAR(1 g) = 0.291 W/kg; SAR(10 g) = 0.133 W/kg
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.410 W/kg




                      0 dB = 0.410 W/kg = -3.87 dBW/kg




                                                                                                               Plot No. 25


Test Laboratory: UL Verification Services Inc., SAR Lab 4                    Date/Time: 8/4/2015 10:23:24 PM

Wi-Fi 5GHz

Frequency: 5300 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                               3
Medium parameters used: f = 5300 MHz; σ = 4.54 S/m; εr = 34.704; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1377; Calibrated: 8/27/2014
- Probe: EX3DV4 - SN3989; ConvF(5.3, 5.3, 5.3); Calibrated: 3/17/2015;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Phantom: SAM with CRP; Type: SAM;

LHS/Touch_802.11a_Ch 60/Area Scan (12x20x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 0.445 W/kg

LHS/Touch_802.11a_Ch 60/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=2mm
Reference Value = 8.926 V/m; Power Drift = 0.19 dB
Peak SAR (extrapolated) = 1.32 W/kg
SAR(1 g) = 0.307 W/kg; SAR(10 g) = 0.097 W/kg
Maximum value of SAR (measured) = 0.637 W/kg




                      0 dB = 0.637 W/kg = -1.96 dBW/kg




                                                                                                               Plot No. 26


Test Laboratory: UL Verification Services Inc., SAR Lab 4                    Date/Time: 8/5/2015 7:56:55 PM

Wi-Fi 5GHz

Frequency: 5300 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 5300 MHz; σ = 5.658 S/m; εr = 48.244; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1377; Calibrated: 8/27/2014
- Probe: EX3DV4 - SN3989; ConvF(4.77, 4.77, 4.77); Calibrated: 3/17/2015;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Phantom: ELI A (v5.0); Type: QDOVA001BB; Serial: S/n:1212

Rear/802.11a_Ch 60/Area Scan (12x20x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 0.333 W/kg

Rear/802.11a_Ch 60/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm
Reference Value = 7.502 V/m; Power Drift = 0.17 dB
Peak SAR (extrapolated) = 0.735 W/kg
SAR(1 g) = 0.188 W/kg; SAR(10 g) = 0.067 W/kg
Maximum value of SAR (measured) = 0.364 W/kg




                      0 dB = 0.364 W/kg = -4.39 dBW/kg




                                                                                                               Plot No. 27


Test Laboratory: UL Verification Services Inc., SAR Lab 4                    Date/Time: 8/6/2015 10:00:04 AM

Wi-Fi 5GHz

Frequency: 5300 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 5300 MHz; σ = 5.396 S/m; εr = 47.204; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1377; Calibrated: 8/27/2014
- Probe: EX3DV4 - SN3989; ConvF(4.77, 4.77, 4.77); Calibrated: 3/17/2015;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Phantom: ELI A (v5.0); Type: QDOVA001BB; Serial: S/n:1212

Edge 2/802.11a_Ch 60/Area Scan (8x19x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 2.27 W/kg

Edge 2/802.11a_Ch 60/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm
Reference Value = 19.26 V/m; Power Drift = -0.15 dB
Peak SAR (extrapolated) = 6.11 W/kg
SAR(1 g) = 1.15 W/kg; SAR(10 g) = 0.275 W/kg
Maximum value of SAR (measured) = 2.67 W/kg




                      0 dB = 2.67 W/kg = 4.27 dBW/kg




                                                                                                               Plot No. 28


Test Laboratory: UL Verification Services Inc., SAR Lab 4                   Date/Time: 8/4/2015 11:20:45 PM

Wi-Fi 5GHz

Frequency: 5700 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                               3
Medium parameters used: f = 5700 MHz; σ = 4.949 S/m; εr = 34.22; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1377; Calibrated: 8/27/2014
- Probe: EX3DV4 - SN3989; ConvF(4.9, 4.9, 4.9); Calibrated: 3/17/2015;
- Sensor-Surface: 2mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2mm
(Mechanical Surface Detection)
- Phantom: SAM with CRP; Type: SAM;

LHS/Touch_802.11a_Ch 140/Area Scan (12x20x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 0.342 W/kg

LHS/Touch_802.11a_Ch 140/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=2mm
Reference Value = 7.366 V/m; Power Drift = 0.08 dB
Peak SAR (extrapolated) = 1.01 W/kg
SAR(1 g) = 0.217 W/kg; SAR(10 g) = 0.069 W/kg
Maximum value of SAR (measured) = 0.452 W/kg




                      0 dB = 0.452 W/kg = -3.45 dBW/kg




                                                                                                           Plot No. 29


Test Laboratory: UL Verification Services Inc., SAR Lab 4                   Date/Time: 8/5/2015 8:43:11 PM

Wi-Fi 5GHz

Frequency: 5700 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 5700 MHz; σ = 6.159 S/m; εr = 47.354; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1377; Calibrated: 8/27/2014
- Probe: EX3DV4 - SN3989; ConvF(4, 4, 4); Calibrated: 3/17/2015;
- Sensor-Surface: 2mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2mm
(Mechanical Surface Detection)
- Phantom: ELI A (v5.0); Type: QDOVA001BB; Serial: S/n:1212

Rear/802.11a_Ch 140/Area Scan (12x20x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 0.272 W/kg

Rear/802.11a_Ch 140/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm
Reference Value = 6.350 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 0.508 W/kg
SAR(1 g) = 0.124 W/kg; SAR(10 g) = 0.044 W/kg
Maximum value of SAR (measured) = 0.266 W/kg




                      0 dB = 0.266 W/kg = -5.75 dBW/kg




                                                                                                             Plot No. 30


Test Laboratory: UL Verification Services Inc., SAR Lab 4                   Date/Time: 8/6/2015 8:57:14 AM

Wi-Fi 5GHz

Frequency: 5700 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 5700 MHz; σ = 6.159 S/m; εr = 47.354; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1377; Calibrated: 8/27/2014
- Probe: EX3DV4 - SN3989; ConvF(4, 4, 4); Calibrated: 3/17/2015;
- Sensor-Surface: 2mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2mm
(Mechanical Surface Detection)
- Phantom: ELI A (v5.0); Type: QDOVA001BB; Serial: S/n:1212

Rear/802.11a_Ch 140/Area Scan (12x20x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 2.16 W/kg

Rear/802.11a_Ch 140/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm
Reference Value = 16.65 V/m; Power Drift = -0.01 dB
Peak SAR (extrapolated) = 5.02 W/kg
SAR(1 g) = 0.926 W/kg; SAR(10 g) = 0.241 W/kg
Maximum value of SAR (measured) = 1.96 W/kg




                      0 dB = 1.96 W/kg = 2.92 dBW/kg




                                                                                                             Plot No. 31


Test Laboratory: UL Verification Services Inc., SAR Lab 4                   Date/Time: 8/5/2015 6:36:52 PM

Wi-Fi 5GHz

Frequency: 5825 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 5825 MHz; σ = 5.046 S/m; εr = 34.092; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1377; Calibrated: 8/27/2014
- Probe: EX3DV4 - SN3989; ConvF(5.03, 5.03, 5.03); Calibrated: 3/17/2015;
- Sensor-Surface: 2mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2mm
(Mechanical Surface Detection)
- Phantom: SAM with CRP; Type: SAM;

LHS/Touch_802.11a_Ch 165/Area Scan (12x20x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 0.253 W/kg

LHS/Touch_802.11a_Ch 165/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=2mm
Reference Value = 6.284 V/m; Power Drift = 0.18 dB
Peak SAR (extrapolated) = 1.32 W/kg
SAR(1 g) = 0.117 W/kg; SAR(10 g) = 0.038 W/kg
Maximum value of SAR (measured) = 0.275 W/kg




                      0 dB = 0.275 W/kg = -5.61 dBW/kg




                                                                                                             Plot No. 32


Test Laboratory: UL Verification Services Inc., SAR Lab 4                   Date/Time: 8/5/2015 9:20:01 PM

Wi-Fi 5GHz

Frequency: 5825 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 5825 MHz; σ = 6.277 S/m; εr = 47.259; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1377; Calibrated: 8/27/2014
- Probe: EX3DV4 - SN3989; ConvF(4.36, 4.36, 4.36); Calibrated: 3/17/2015;
- Sensor-Surface: 2mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2mm
(Mechanical Surface Detection)
- Phantom: ELI A (v5.0); Type: QDOVA001BB; Serial: S/n:1212

Rear/802.11a_Ch 165/Area Scan (12x20x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 0.208 W/kg

Rear/802.11a_Ch 165/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm
Reference Value = 5.581 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 0.453 W/kg
SAR(1 g) = 0.104 W/kg; SAR(10 g) = 0.031 W/kg
Maximum value of SAR (measured) = 0.226 W/kg




                      0 dB = 0.226 W/kg = -6.46 dBW/kg




                                                                                                             Plot No. 33



Document Created: 2015-09-14 10:56:03