Test Report

FCC ID: ZNFD850

Test Report

Download: PDF
FCCID_2293338

                               PCTEST ENGINEERING LABORATORY, INC.
                                             7185 Oakland Mills Road, Columbia, MD 21046 USA
                                                   Tel. 410.290.6652 / Fax 410.290.6654
                                                          http://www.pctestlab.com

                                                    MEASUREMENT REPORT
                                                          FCC Part 15.225 NFC


Applicant Name:                                                                Date of Testing:
LG Electronics MobileComm U.S.A                                                5/7 - 5/29/2014
1000 Sylvan Avenue                                                             Test Site/Location:
Englewood Cliffs, NJ 07632                                                     PCTEST Lab, Columbia, MD, USA
United States                                                                  Test Report Serial No.:
                                                                               0Y1405060929.ZNF


FCC ID:                                             ZNFD850

APPLICANT:                                          LG Electronics MobileComm U.S.A

Application Type:                                     Class II Permissive Change
                                                      LG-D850, D850, LGD850, LG-D852, D852, LGD852, LG-D852G,
Model(s):
                                                      D852G, LGD852G
EUT Type:                                             Portable Handset
Frequency:                                            13.56MHz
FCC Classification:                                   Low Power Communications Device Transmitter (DXX)
FCC Rule Part(s):                                     FCC Part 15 Subpart C (15.225)
Test Procedure(s):                                    ANSI C63.10-2009, KDB 648474 D03 v01r02
Class II Permissive Change:                           Please see FCC change document
Original Grant Date:                                  5/19/2014
The device bearing the FCC Identifier specified above has been shown to comply with the applicable technical standards as indicated in
the measurement report and has been tested in accordance with the measurement procedures specified in ANSI C63.10-2009 (See Test
Report). These measurements were performed with no deviation from the standards. Test results reported herein relate only to the item(s)
tested.

I authorize and attest to the accuracy of data. All measurements reported herein were performed by me or were made under my
supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these
measurements and vouch for the qualifications of all persons taking them.

NVLAP accreditation does not constitute any product endorsement by NVLAP or any agency of the United States Government. This
report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the
Federal Government.




                                                                  FCC Pt. 15.225 MEASUREMENT REPORT                    Reviewed by:
FCC ID: ZNFD850
                                                                     (CLASS II PERMISSIVE CHANGE)                      Quality Manager
Test Report S/N:                    Test Date(s):           EUT Type:
                                                                                                                       Page 1 of 17
0Y1405060929.ZNF                    5/7 - 5/29/2014         Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                           V5.0
                                                                                                                               01/13/2014


                                         T A B L E                        O F             C O N T E N T S

      FCC Part 15.225 MEASUREMENT REPORT ............................................................................................. 3
       1.0        INTRODUCTION .............................................................................................................................. 4
                  1.1      SCOPE .................................................................................................................................................. 4
                  1.2      PCTEST TEST LOCATION ................................................................................................................... 4
       2.0        PRODUCT INFORMATION.............................................................................................................. 5
                  2.1      EQUIPMENT DESCRIPTION ................................................................................................................ 5
                  2.2      DEVICE CAPABILITIES ........................................................................................................................ 5
                  2.3      TEST CONFIGURATION ...................................................................................................................... 5
                  2.4      EMI SUPPRESSION DEVICE(S)/MODIFICATIONS ............................................................................. 5
                  2.5      LABELING REQUIREMENTS ............................................................................................................... 5
       3.0        DESCRIPTION OF TEST ................................................................................................................. 6
                  3.1      EVALUATION PROCEDURE ................................................................................................................ 6
                  3.2      RADIATED EMISSIONS........................................................................................................................ 6
       4.0        ANTENNA REQUIREMENTS ..........................................................................................................7
       5.0        SAMPLE CALCULATIONS .............................................................................................................. 8
                  5.1      CONDUCTED EMISSION MEASUREMENT SAMPLE CALCULATION ............................................... 8
                  5.2      RADIATED EMISSION MEASUREMENT SAMPLE CALCULATION .................................................... 8
       6.0        TEST EQUIPMENT CALIBRATION DATA ...................................................................................... 9
       7.0        ENVIRONMENTAL CONDITIONS ................................................................................................. 10
       8.0        TEST DATA .................................................................................................................................... 11
                  8.1      SUMMARY .......................................................................................................................................... 11
                  8.2      IN-BAND RADIATED SPURIOUS EMISSION MEASUREMENTS...................................................... 12
                  IN-BAND RADIATED SPURIOUS EMISSION MEASUREMENTS WITH WCC ............................................ 13
                  8.3      RADIATED SPURIOUS EMISSION MEASUREMENTS, OUT-OF-BAND .......................................... 14
       9.0        CONCLUSION ................................................................................................................................ 17




                                                                             FCC Pt. 15.225 MEASUREMENT REPORT                                                 Reviewed by:
FCC ID: ZNFD850
                                                                                (CLASS II PERMISSIVE CHANGE)                                                   Quality Manager
Test Report S/N:                    Test Date(s):                   EUT Type:
                                                                                                                                                               Page 2 of 17
0Y1405060929.ZNF                    5/7 - 5/29/2014                 Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                                                                     V5.0
                                                                                                                                                                         01/13/2014


                                                      MEASUREMENT REPORT
                                                               FCC Part 15.225


§ 2.1033 General Information
        APPLICANT:                           LG Electronics MobileComm U.S.A
        APPLICANT ADDRESS:                   1000 Sylvan Avenue
                                             Englewood Cliffs, NJ 07632
                                             United States
        TEST SITE:                           PCTEST ENGINEERING LABORATORY, INC.
        TEST SITE ADDRESS:                   7185 Oakland Mills Road, Columbia, MD 21046 USA
        FCC RULE PART(S):                    Part 15 Subpart C (15.225)
        BASE MODEL:                          LG-D850
        FCC ID:                              ZNFD850
        FCC CLASSIFICATION:                  Low Power Communications Device Transmitter (DXX)
        Test Device Serial No.:              NFC Rad                         Production     Pre-Production   Engineering
        DATE(S) OF TEST:                     5/7 - 5/29/2014
        TEST REPORT S/N:                     0Y1405060929.ZNF


Test Facility / Accreditations
Measurements were performed at PCTEST Engineering Lab located in Columbia, MD 21046, U.S.A.
                               PCTEST facility is an FCC registered (PCTEST Reg. No. 159966) test facility with the
                                site description report on file and has met all the requirements specified in Section
                                2.948 of the FCC Rules and Industry Canada (2451B-1).
                               PCTEST Lab is accredited to ISO 17025 by U.S. National Institute of Standards and
                                Technology (NIST) under the National Voluntary Laboratory Accreditation Program
                                (NVLAP Lab code: 100431-0) in EMC, FCC and Telecommunications.
                               PCTEST Lab is accredited to ISO 17025-2005 by the American Association for
                                Laboratory Accreditation (A2LA) in Specific Absorption Rate (SAR) testing, Hearing Aid
                                Compatibility (HAC) testing, CTIA Test Plans, and wireless testing for FCC and
                                Industry Canada Rules.
                               PCTEST Lab is a recognized U.S. Conformity Assessment Body (CAB) in EMC and
                                R&TTE (n.b. 0982) under the U.S.-EU Mutual Recognition Agreement (MRA).
                               PCTEST TCB is a Telecommunication Certification Body (TCB) accredited to ISO/IEC
                                Guide 65 by the American National Standards Institute (ANSI) in all scopes of FCC
                                Rules and Industry Canada Standards (RSS).
                               PCTEST facility is an IC registered (2451B-1) test laboratory with the site description
                                on file at Industry Canada.
                               PCTEST is a CTIA Authorized Test Laboratory (CATL) for AMPS, CDMA, and EvDO
                                wireless devices and for Over-the-Air (OTA) Antenna Performance testing for AMPS,
                                CDMA, GSM, GPRS, EGPRS, UMTS (W-CDMA), CDMA 1xEVDO, and CDMA 1xRTT.



                                                                FCC Pt. 15.225 MEASUREMENT REPORT              Reviewed by:
FCC ID: ZNFD850
                                                                   (CLASS II PERMISSIVE CHANGE)                Quality Manager
Test Report S/N:                    Test Date(s):         EUT Type:
                                                                                                               Page 3 of 17
0Y1405060929.ZNF                    5/7 - 5/29/2014       Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                   V5.0
                                                                                                                       01/13/2014


1.0          INTRODUCTION

 1.1         Scope
 Measurement and determination of electromagnetic emissions (EMC) of radio frequency devices including
 intentional and/or unintentional radiators for compliance with the technical rules and regulations of the Federal
 Communications Commission and the Industry Canada Certification and Engineering Bureau.


 1.2         PCTEST Test Location
 The map below shows the location of the PCTEST LABORATORY, its proximity to the FCC Laboratory, the
 Columbia vicinity, the Baltimore-Washington Internt’l (BWI) airport, the city of Baltimore and the Washington,
 DC area. (See Figure 1-1).

 These measurement tests were conducted at the PCTEST Engineering Laboratory, Inc. facility located at
 7185 Oakland Mills Road, Columbia, MD 21046. The site coordinates are 39o 10’23” N latitude and 76o 49’50”
 W longitude. The facility is 0.4 miles North of the FCC laboratory, and the ambient signal and ambient signal
 strength are approximately equal to those of the FCC laboratory. The detailed description of the measurement
 facility was found to be in compliance with the requirements of § 2.948 according to ANSI C63.4-2009 on
 February 15, 2012.




                  Figure 1-1. Map of the Greater Baltimore and Metropolitan Washington, D.C. area
                                                             FCC Pt. 15.225 MEASUREMENT REPORT      Reviewed by:
 FCC ID: ZNFD850
                                                                (CLASS II PERMISSIVE CHANGE)        Quality Manager
 Test Report S/N:                    Test Date(s):     EUT Type:
                                                                                                    Page 4 of 17
 0Y1405060929.ZNF                    5/7 - 5/29/2014   Portable Handset
 © 2014 PCTEST Engineering Laboratory, Inc.                                                                       V5.0
                                                                                                            01/13/2014


2.0             PRODUCT INFORMATION


2.1         Equipment Description
The Equipment Under Test (EUT) is the LG Portable Handset FCC ID: ZNFD850. The test data contained in
this report pertains only to the emissions due to the NFC transmitter of the EUT.

2.2         Device Capabilities
This device contains the following capabilities:

850/1900 GSM/EDGE, 850/1700/1900 WCDMA, Band 17 (5, 10MHz BW), 5 (5, 10MHz BW), 4 (5, 10, 15,
20MHz BW), 2 (5, 10, 15, 20MHz BW), 7 (5, 10, 15, 20MHz BW) LTE, 802.11a/b/g/n/ac WLAN, 802.11a/n/ac
UNII, Bluetooth (1x, EDR, LE), NFC

2.3         Test Configuration
The LG Portable Handset FCC ID: ZNFD850 was set to continuously transmit at 13.56MHz. This was
performed using manufacturer software loaded on the phone and a passive RFID tag to allow for continuous
transmission. This device was tested in accordance with the guidance of ANSI C63.10-2009. See Sections 3.2
and 8.1 of this test report for a description of the radiated emissions test setups. Additional emissions testing
were performed per KDB 648474 D03 and the additional worst case emissions are reported herein and
identified as WCC.

Per KDB 648474 D03, spurious emissions measurement data was also investigated with the wireless charging
battery cover. The handset was placed on the representative charging pad under normal conditions and in a
simulated call configuration. Only worst case emissions are shown in this report.

2.4         EMI Suppression Device(s)/Modifications
No EMI suppression device(s) were added and no modifications were made during testing.

2.5         Labeling Requirements
Per 15.19; Docket 95-19

The label shall be permanently affixed at a conspicuous location on the device; instruction manual or pamphlet
supplied to the user and be readily visible to the purchaser at the time of purchase. However, when the device
is so small wherein placement of the label with specified statement is not practical, only the trade name and
FCC ID must be displayed on the device per Section 15.19(a)(5). Please see attachment for FCC ID label and
label location.




                                                            FCC Pt. 15.225 MEASUREMENT REPORT      Reviewed by:
FCC ID: ZNFD850
                                                               (CLASS II PERMISSIVE CHANGE)        Quality Manager
Test Report S/N:                    Test Date(s):     EUT Type:
                                                                                                   Page 5 of 17
0Y1405060929.ZNF                    5/7 - 5/29/2014   Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                       V5.0
                                                                                                           01/13/2014


3.0             DESCRIPTION OF TEST

3.1         Evaluation Procedure
The measurement procedure described in the American National Standard for Testing Unlicensed Wireless
Devices (ANSI C63.10-2009) was used in the measurement of the LG Portable Handset
FCC ID: ZNFD850.

Deviation from measurement procedure…………………………………………….....................................None

3.2         Radiated Emissions
The radiated test facilities consisted of an indoor 3 meter semi-anechoic chamber used for final measurements
and exploratory measurements, when necessary. The measurement area is contained within the semi-
anechoic chamber which is shielded from any ambient interference. The test site inside the chamber is a 6m x
5.2m elliptical, obstruction-free area in accordance with Clause 5, Figure 5.7 of ANSI C63.4-2009. For
measurements above 1GHz absorbers are arranged on the floor between the turn table and the antenna mast
in such a way so as to maximize the reduction of reflections. For measurements below 1GHz, the absorbers
are removed. An ETS Lindgren Model 2188 raised turntable is used for radiated measurement. It is a
continuously rotatable, remote-controlled, metallic turntable and 2 meters (6.56 ft.) in diameter. The turn table
is flush with the raised floor of the chamber in order to maintain its function as a ground plane. A 78cm high
PVC support structure is placed on top of the turntable. A ¾” (~1.9cm) sheet of high density polyethylene is
used as the table top and is placed on top of the PVC supports to bring the total height of the table to 80cm.

For all measurements, the spectrum was scanned through all EUT azimuths and from 1 to 4 meter receive
antenna height using a broadband antenna from 30MHz up to the upper frequency shown in 15.33(b)(1)
depending on the highest frequency generated or used in the device or on which the device operates or tunes.
For frequencies above 1GHz, linearly polarized double ridge horn antennas were used. For frequencies below
30MHz, a calibrated loop antenna was used. When exploratory measurements were necessary, they were
performed at 1 meter test distance inside the semi-anechoic chamber using broadband antennas, broadband
amplifiers, and spectrum analyzers to determine the frequencies and modes producing the maximum
emissions. Sufficient time for the EUT, support equipment, and test equipment was allowed in order for them
to warm up to their normal operating condition. The test set-up was placed on top of the 0.8 meter high, 1 x
1.5 meter table. The EUT, support equipment, and interconnecting cables were arranged and manipulated to
maximize each emission. Appropriate precaution was taken to ensure that all emissions from the EUT were
maximized and investigated. The system configuration, clock speed, mode of operation or video resolution, if
applicable, turntable azimuth, and receive antenna height was noted for each frequency found.

Final measurements were made in the semi-anechoic chamber using calibrated, linearly polarized broadband
and horn antennas. The test setup was configured to the setup that produced the worst case emissions. The
spectrum analyzer was set to investigate all frequencies required for testing to compare the highest radiated
disturbances with respect to the specified limits. The turntable containing the EUT was rotated through 360
degrees and the height of the receive antenna was varied 1 to 4 meters and stopped at the azimuth and height
producing the maximum emission. Each emission was maximized by changing the orientation of the EUT
through three orthogonal planes and changing the polarity of the receive antenna, whichever produced the
worst-case emissions. For the EUT positioning, “H” is defined with the EUT lying flat on the test surface, “H2”
is defined with the EUT standing up on its side, and “V” is defined with the EUT standing upright.




                                                            FCC Pt. 15.225 MEASUREMENT REPORT      Reviewed by:
FCC ID: ZNFD850
                                                               (CLASS II PERMISSIVE CHANGE)        Quality Manager
Test Report S/N:                    Test Date(s):     EUT Type:
                                                                                                   Page 6 of 17
0Y1405060929.ZNF                    5/7 - 5/29/2014   Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                       V5.0
                                                                                                           01/13/2014


4.0          ANTENNA REQUIREMENTS

 Excerpt from §15.203 of the FCC Rules/Regulations:
 “An intentional radiator antenna shall be designed to ensure that no antenna other than that furnished by the
 responsible party can be used with the device. The use of a permanently attached antenna or of an antenna
 that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the
 provisions of this section.”


         The antenna of the LG Portable Handset are permanently attached.

         There are no provisions for connection to an external antenna.

         This unit was tested with its standard battery.


 Conclusion:
 The LG Portable Handset FCC ID: ZNFD850 unit complies with the requirement of §15.203.




                                                             FCC Pt. 15.225 MEASUREMENT REPORT   Reviewed by:
  FCC ID: ZNFD850
                                                                (CLASS II PERMISSIVE CHANGE)     Quality Manager
  Test Report S/N:                   Test Date(s):     EUT Type:
                                                                                                 Page 7 of 17
  0Y1405060929.ZNF                   5/7 - 5/29/2014   Portable Handset
 © 2014 PCTEST Engineering Laboratory, Inc.                                                                    V5.0
                                                                                                         01/13/2014


5.0             SAMPLE CALCULATIONS

5.1         Conducted Emission Measurement Sample Calculation
            @ 20.3 MHz

                        Class B limit                 = 60.0 dBV (Quasi-peak limit)
                        Reading                       = - 57.8 dBm (calibrated quasi-peak level)
                        Convert to dbV               = - 57.8 + 107 = 49.2 dBV


                        Margin                        = 49.2 - 60.0 = - 10.8 dB
                                                      = 10.8 dB below limit


5.2         Radiated Emission Measurement Sample Calculation
            @ 66.7 MHz
                        Class B limit                          = 100 V/m = 40.0 dBV/m
                        Reading                                = - 76.0 dBm (calibrated level)
                        Convert to dbV                        = - 76.0 + 107 = 31.0 dBV
                        Antenna Factor + Cable Loss            = 5.8 dB/m
                                                      Total    = 36.8 dBV/m


                        Margin                                 = 36.8 - 40.0 = - 3.2 dB
                                                               = 3.2 dB below limit




                Note:


                   Level [dBV] = 20 log 10 (Level [V/m])
                     Level [dBV] = Level [dBm] + 107




                                                              FCC Pt. 15.225 MEASUREMENT REPORT    Reviewed by:
FCC ID: ZNFD850
                                                                 (CLASS II PERMISSIVE CHANGE)      Quality Manager
Test Report S/N:                    Test Date(s):       EUT Type:
                                                                                                   Page 8 of 17
0Y1405060929.ZNF                    5/7 - 5/29/2014     Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                       V5.0
                                                                                                           01/13/2014


6.0             TEST EQUIPMENT CALIBRATION DATA

Test Equipment Calibration is traceable to the National Institute of Standards and Technology (NIST).

  Manufacturer                 Model                         Description                 Cal Date    Cal Interval   Cal Due     Serial Number

       ‐                         RE1            Radiated Emissions Cable Set (UHF/EHF)   3/25/2014     Annual       3/25/2015       N/A
    Agilent                     8447D                    Broadband Amplifier             5/31/2013     Annual       5/31/2014    2443A01900
  Com‐Power                     AL‐130                9kHz ‐ 30MHz Loop Antenna          6/26/2013     Annual       6/26/2014      121034
     Emco                        6502             Active Loop Antenna (10k ‐ 30 MHz)     5/31/2012    Biennial      5/31/2014        267
     Espec                     ESX‐2CA                 Environmental Chamber             4/16/2014     Annual       4/16/2015       17620
Rohde & Schwarz                 ESU26                 EMI Test Receiver (26.5GHz)        1/27/2014     Annual       1/27/2015      100342
     Sunol                       JB5                 Bi‐Log Antenna (30M ‐ 5GHz)         1/28/2014    Biennial      1/28/2016     A051107
                                     Table 6-1. Annual Test Equipment Calibration Schedule

Note:

For equipment listed above that has a calibration due date that falls within the test date range, care was taken
to ensure that this equipment was utilized prior to the calibration due date.




                                                                  FCC Pt. 15.225 MEASUREMENT REPORT                             Reviewed by:
FCC ID: ZNFD850
                                                                     (CLASS II PERMISSIVE CHANGE)                               Quality Manager
Test Report S/N:                    Test Date(s):           EUT Type:
                                                                                                                                Page 9 of 17
0Y1405060929.ZNF                    5/7 - 5/29/2014        Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                                    V5.0
                                                                                                                                        01/13/2014


7.0             ENVIRONMENTAL CONDITIONS


   The temperature is controlled within range of 15oC to 35oC.
   The relative humidity is controlled within range of 10% to 75%.
   The atmospheric pressure is controlled within the range 86-106kPa (860-1060mbar).




                                                            FCC Pt. 15.225 MEASUREMENT REPORT   Reviewed by:
FCC ID: ZNFD850
                                                               (CLASS II PERMISSIVE CHANGE)     Quality Manager
Test Report S/N:                    Test Date(s):     EUT Type:
                                                                                                Page 10 of 17
0Y1405060929.ZNF                    5/7 - 5/29/2014   Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                    V5.0
                                                                                                        01/13/2014


8.0             TEST DATA

8.1         Summary


         Company Name:                                LG Electronics MobileComm U.S.A
         FCC ID:                                      ZNFD850
         FCC Classification:                          Low Power Communications Device Transmitter (DXX)
         Frequencies Examined:                        13.56MHz



        FCC Part                                                                                   Test       Test
                               Test Description                       Test Limit                                      Reference
        Section(s)                                                                               Condition   Result

       TRANSMITTER MODE (Tx)
                                                          15,848µV/m @ 30m
                                                          13.553 – 13.567 MHz

                                                          334µV/m @ 30m
       15.225                                              13.410 – 13.553 MHz
                            In-Band Emissions                                                                 PASS    Section 8.2
       (a)(b)(c)                                          13.567 – 13.710 MHz

                                                          106µV/m @ 30m                          RADIATED
                                                          13.110 – 13.410 MHz
                                                          13.710 – 14.010 MHz

                                                          Emissions outside of the specified
       15.225 (d)                                         band (13.110 – 14.010 MHz) must
                            Out-of-Band Emissions                                                             PASS    Section 8.3
       15.209                                             meet the radiated limits detailed in
                                                          15.209

                                                       Table 8-1. Summary of Test Results

Note:

This unit was tested with its standard battery.




                                                                   FCC Pt. 15.225 MEASUREMENT REPORT                   Reviewed by:
FCC ID: ZNFD850
                                                                      (CLASS II PERMISSIVE CHANGE)                     Quality Manager
Test Report S/N:                    Test Date(s):            EUT Type:
                                                                                                                       Page 11 of 17
0Y1405060929.ZNF                    5/7 - 5/29/2014         Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                           V5.0
                                                                                                                               01/13/2014


8.2         In-Band Radiated Spurious Emission Measurements
§15.225(a)(b)(c)

Radiated emission testing was performed in the band 13.110 – 14.010 MHz.


          Frequency:                                   13.56MHz

          Measurement Distance:                        3 Meters

                                                                                           30m
                                                                              3m Field
 Frequency Antenna EUT Pol.                           Level        AFCL                    Field       Limit       Limit  Margin
                                                                               Strength
   [MHz]   Position [H/H2/V]                          [dBm]       [dB/m]                 Strength     [µV/m]     [dBµV/m]  [dB]
                                                                              [dBµV/m]
                                                                                        [dBµV/m]
     13.240                X                 V        -90.37      14.41         31.04     -8.96        106.00     40.51     -49.47

     13.350                X                 V        -86.96      14.40         34.44     -5.56        106.00     40.51     -46.06

     13.450                X                 V        -84.62      14.40         36.78     -3.22        334.00     50.47     -53.69

     13.560                X                 V        -73.37      14.40         48.03     8.03        15848.00    84.00     -75.97

     13.660                X                 V        -84.23      14.39         37.16     -2.84        334.00     50.47     -53.31

     13.760                X                 V        -87.20      14.39         34.19     -5.81        106.00     40.51     -46.32

     13.870                X                 V        -93.23      14.39         28.16    -11.84        106.00     40.51     -52.35

                                                 Table 8-2. In-Band Radiated Measurements


NOTES:

1.    All measurements were performed using a loop antenna. The antenna was positioned in three orthogonal
      positions (X front, Y side, Z top) and the position with the highest emission level was recorded.
2.    The EUT was positioned in three orthogonal planes to determine the orientation resulting in the worst
      case emissions.
3.    Measurements were performed at 3m and the data was extrapolated to the specified measurement
      distance of 30m using the square of an inverse linear distance extrapolation factor (40 dB/decade) as
      specified in §15.31(f)(2). Extrapolation Factor = 20 log10(30/3)2 = 40dB.
4.    The spectrum was investigated from 9kHz up to 30MHz using the loop antenna. Only the emissions
      shown in the table above were found to be significant.
5.    All measurements were recorded using a spectrum analyzer employing a quasi-peak detector.
6.    Field Strength Level [dBV/m] = Analyzer Level [dBm] + 107 + AFCL [dB/m]
7.    AFCL [dB/m] = Antenna Factor [dB/m] + Cable Loss [dB]
8.    Margin [dB] = Field Strength Level [dBV/m] – Limit [dBV/m]

                                                                  FCC Pt. 15.225 MEASUREMENT REPORT                   Reviewed by:
FCC ID: ZNFD850
                                                                     (CLASS II PERMISSIVE CHANGE)                     Quality Manager
Test Report S/N:                    Test Date(s):          EUT Type:
                                                                                                                      Page 12 of 17
0Y1405060929.ZNF                    5/7 - 5/29/2014        Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                          V5.0
                                                                                                                              01/13/2014


In-Band Radiated Spurious Emission Measurements with WCC
§15.225(a)(b)(c)

Radiated emission testing was performed in the band 13.110 – 14.010 MHz.


          Frequency:                                   13.56MHz

          Measurement Distance:                        3 Meters

                                                                                           30m
                                                                              3m Field
 Frequency Antenna EUT Pol.                           Level        AFCL                    Field       Limit       Limit  Margin
                                                                               Strength
   [MHz]   Position [H/H2/V]                          [dBm]       [dB/m]                 Strength     [µV/m]     [dBµV/m]  [dB]
                                                                              [dBµV/m]
                                                                                        [dBµV/m]
     13.170                Y                  H       -89.15      14.41         32.26     -7.74        106.00     40.51     -48.25

     13.290                Y                  H       -88.06      14.40         33.34     -6.66        106.00     40.51     -47.16

     13.450                Y                  H       -88.38      14.40         33.02     -6.98        334.00     50.47     -57.45

     13.560                Y                  H       -76.99      14.40         44.41     4.41        15848.00    84.00     -79.59

     13.660                Y                  H       -83.81      14.39         37.58     -2.42        334.00     50.47     -52.89

     13.760                Y                  H       -86.41      14.39         34.98     -5.02        106.00     40.51     -45.53

     13.950                Y                  H       -89.24      14.39         32.15     -7.85        106.00     40.51     -48.36

                                             Table 8-3. In-Band Radiated Measurements with WCC

NOTES:

9.    All measurements were performed using a loop antenna. The antenna was positioned in three orthogonal
      positions (X front, Y side, Z top) and the position with the highest emission level was recorded.
10. The EUT was positioned in three orthogonal planes to determine the orientation resulting in the worst
      case emissions.
11. Measurements were performed at 3m and the data was extrapolated to the specified measurement
      distance of 30m using the square of an inverse linear distance extrapolation factor (40 dB/decade) as
      specified in §15.31(f)(2). Extrapolation Factor = 20 log10(30/3)2 = 40dB.
12. The spectrum was investigated from 9kHz up to 30MHz using the loop antenna. Only the emissions
      shown in the table above were found to be significant.
13. All measurements were recorded using a spectrum analyzer employing a quasi-peak detector.
14. Field Strength Level [dBV/m] = Analyzer Level [dBm] + 107 + AFCL [dB/m]
15. AFCL [dB/m] = Antenna Factor [dB/m] + Cable Loss [dB]
16. Margin [dB] = Field Strength Level [dBV/m] – Limit [dBV/m]


                                                                  FCC Pt. 15.225 MEASUREMENT REPORT                   Reviewed by:
FCC ID: ZNFD850
                                                                     (CLASS II PERMISSIVE CHANGE)                     Quality Manager
Test Report S/N:                    Test Date(s):          EUT Type:
                                                                                                                      Page 13 of 17
0Y1405060929.ZNF                    5/7 - 5/29/2014        Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                          V5.0
                                                                                                                              01/13/2014


8.3         Radiated Spurious Emission Measurements, Out-of-Band
§15.209 §15.225(d)

The EUT was tested from 9kHz up to the 1GHz excluding the band 13.110 – 14.010 MHz. All measurements
up to 960MHz were recorded with a spectrum analyzer employing a quasi-peak detector. All out-of-band
emissions must not exceed the limits shown in Table 8-4 per Section 15.209. A loop antenna was used to
investigate emissions below 30MHz.



                                                                  Field Strength           Measured Distance
                                    Frequency
                                                                      [V/m]                   [Meters]


                               0.009 – 0.490 MHz                    2400/F (kHz)                      300



                               0.490 – 1.705 MHz                   24000/F (kHz)                      30



                               1.705 – 30.00 MHz                          30                          30



                               30.00 – 88.00 MHz                          100                          3



                               88.00 – 216.0 MHz                          150                          3



                               216.0 – 960.0 MHz                          200                          3



                                Above 960.0 MHz                           500                          3

                                                    Table 8-4. Radiated Limits – Out of band

Sample Calculation

o     Field Strength Level [dBV/m] = Analyzer Level [dBm] + 107 + AFCL [dB/m]
o     AFCL [dB/m] = Antenna Factor [dB/m] + Cable Loss [dB]
o     Margin [dB] = Field Strength Level [dBV/m] – Limit [dBV/m]




                                                                  FCC Pt. 15.225 MEASUREMENT REPORT            Reviewed by:
FCC ID: ZNFD850
                                                                     (CLASS II PERMISSIVE CHANGE)              Quality Manager
Test Report S/N:                    Test Date(s):           EUT Type:
                                                                                                               Page 14 of 17
0Y1405060929.ZNF                    5/7 - 5/29/2014         Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                   V5.0
                                                                                                                       01/13/2014


Radiated Spurious Emission Measurements, Out-of-Band
§15.209 §15.225(d)


  Tx Frequency                                      13.56MHz

  Measurement Distance:                             3 Meters


                                 Ant.   EUT                                                3m Field
                      Frequency                                  Level             AFCL                Limit  Margin
                                 Pol.   Pol.                                                Strength
                        [MHz]                                    [dBm]            [dB/m]             [dBµV/m]  [dB]
                                [H/V] [H/H2/V]                                             [dBµV/m]

                          27.12              X         V         -90.86           12.87     29.01    69.54    -40.53

                          40.68              V         V         -78.62           14.33     16.91    32.04    -15.13

                          54.24              V         V         -78.62            8.44     11.07    32.04    -20.97

                          67.80              V         V         -78.90            8.64     11.09    32.04    -20.96

                          81.36              V         V         -78.71            8.40     11.02    32.04    -21.02

                          94.92              V         V         -74.41            9.83     16.72    32.77    -16.05

                         108.48              V         V         -78.45           13.09     15.93    32.77    -16.84
                                                           Table 8-5. Radiated Measurements


NOTES:

      1. All measurements were recorded using a spectrum analyzer employing a quasi-peak detector for
            emissions below 960MHz.


      2. Both Vertical and Horizontal polarities of the receive antenna were evaluated with the worst case
            emissions being reported. Below 30MHz the loop antenna was positioned in 3 orthogonal planes (X
            front, Y side, Z top) to determine the orientation resulting in the worst case emissions.


      3. The EUT was positioned in three orthogonal planes to determine the orientation resulting in the worst
            case emissions.


      4. The spectrum is measured from 9kHz to the 10th harmonic and the worst-case emissions are reported.

      5. No spurious emissions levels were found to be greater than the level of the fundamental.




                                                                     FCC Pt. 15.225 MEASUREMENT REPORT                 Reviewed by:
FCC ID: ZNFD850
                                                                        (CLASS II PERMISSIVE CHANGE)                   Quality Manager
Test Report S/N:                    Test Date(s):              EUT Type:
                                                                                                                       Page 15 of 17
0Y1405060929.ZNF                    5/7 - 5/29/2014            Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                           V5.0
                                                                                                                               01/13/2014


Radiated Spurious Emission Measurements, Out-of-Band with WCC
§15.209 §15.225(d)


  Tx Frequency                                      13.56MHz

  Measurement Distance:                             3 Meters


                                 Ant.   EUT                                                3m Field
                      Frequency                                  Level             AFCL                Limit  Margin
                                 Pol.   Pol.                                                Strength
                        [MHz]                                    [dBm]            [dB/m]             [dBµV/m]  [dB]
                                [H/V] [H/H2/V]                                             [dBµV/m]

                          27.12              Y         H         -88.75           12.87     31.12    69.54    -38.42

                          40.68              H         H         -68.63           14.33     26.90    32.04    -5.14

                          54.24              H         H         -64.56            8.44     25.13    32.04    -6.91

                          67.80              H         H         -63.21            8.64     26.78    32.04    -5.27

                          81.36              H         H         -72.72            8.40     17.01    32.04    -15.03

                          94.92              H         H         -74.71            9.83     16.42    32.77    -16.35

                         108.48              H         H         -77.90           13.09     16.48    32.77    -16.29
                                                    Table 8-6. Radiated Measurements with WCC


NOTES:

      1. All measurements were recorded using a spectrum analyzer employing a quasi-peak detector for
            emissions below 960MHz.


      2. Both Vertical and Horizontal polarities of the receive antenna were evaluated with the worst case
            emissions being reported. Below 30MHz the loop antenna was positioned in 3 orthogonal planes (X
            front, Y side, Z top) to determine the orientation resulting in the worst case emissions.


      3. The EUT was positioned in three orthogonal planes to determine the orientation resulting in the worst
            case emissions.


      4. The spectrum is measured from 9kHz to the 10th harmonic and the worst-case emissions are reported.

      5. No spurious emissions levels were found to be greater than the level of the fundamental.




                                                                     FCC Pt. 15.225 MEASUREMENT REPORT                 Reviewed by:
FCC ID: ZNFD850
                                                                        (CLASS II PERMISSIVE CHANGE)                   Quality Manager
Test Report S/N:                    Test Date(s):              EUT Type:
                                                                                                                       Page 16 of 17
0Y1405060929.ZNF                    5/7 - 5/29/2014            Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                                           V5.0
                                                                                                                               01/13/2014


9.0             CONCLUSION


   The data collected relate only to the item(s) tested and show that the LG Portable Handset
   FCC ID: ZNFD850 has been tested to show compliance with the requirements specified in §15.225 of the
   FCC Rules.




                                                            FCC Pt. 15.225 MEASUREMENT REPORT   Reviewed by:
FCC ID: ZNFD850
                                                               (CLASS II PERMISSIVE CHANGE)     Quality Manager
Test Report S/N:                    Test Date(s):     EUT Type:
                                                                                                Page 17 of 17
0Y1405060929.ZNF                    5/7 - 5/29/2014   Portable Handset
© 2014 PCTEST Engineering Laboratory, Inc.                                                                    V5.0
                                                                                                        01/13/2014



Document Created: 2019-10-16 18:28:00
Document Modified: 2019-10-16 18:28:00

© 2025 FCC.report