HAC Validation plot

FCC ID: ZNFD820

Test Report

Download: PDF
FCCID_2037394

Test Laboratory: UL Verification Services Inc. SAR Lab C                           Date: 7/3/2013

HAC-RF Emission
Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/29/2013;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1258; Calibrated: 3/6/2013
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

Dipole E-Field measurement/835 MHz/Hearing Aid Compatibility Test at 15mm distance
(41x361x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 110.1 V/m; Power Drift = 0.03 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 111.8 V/m
Near-field category: M4 (AWF 0 dB)

                                         PMF scaled E-field
                                          Grid 1 M4 Grid 2 M4 Grid 3 M4
                                          108.8 V/m        111.1 V/m   110.0 V/m
                                          Grid 4 M4        Grid 5 M4   Grid 6 M4
                                          61.63 V/m        62.81 V/m   61.88 V/m
                                          Grid 7 M4        Grid 8 M4   Grid 9 M4
                                          109.4 V/m        111.8 V/m   109.7 V/m




             0 dB = 111.8 V/m = 40.97 dBV/m


Test Laboratory: UL Verification Services Inc. SAR Lab C                           Date: 7/3/2013

HAC-RF Emission
Communication System: UID 0, CW; Frequency: 1880 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/29/2013;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1258; Calibrated: 3/6/2013
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

Dipole E-Field measurement/1880 MHz/Hearing Aid Compatibility Test at 15mm
distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 156.7 V/m; Power Drift = 0.04 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 91.40 V/m
Near-field category: M3 (AWF 0 dB)

                                         PMF scaled E-field
                                          Grid 1 M3 Grid 2 M3 Grid 3 M3
                                          89.26 V/m        91.40 V/m   90.42 V/m
                                          Grid 4 M3        Grid 5 M3   Grid 6 M3
                                          70.58 V/m        71.48 V/m   70.31 V/m
                                          Grid 7 M3        Grid 8 M3   Grid 9 M3
                                          86.14 V/m        88.92 V/m   88.42 V/m




             0 dB = 91.40 V/m = 39.22 dBV/m



Document Created: 2013-07-22 17:17:03
Document Modified: 2013-07-22 17:17:03

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC