B_15I20528v0 System Validation Plots

FCC ID: ZNF329G

RF Exposure Info

Download: PDF
FCCID_2819018

Test Laboratory: UL Verification Services Inc. SAR Lab C                           Date: 5/12/2015

HAC-RF Emission
Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2339; ConvF(1, 1, 1); Calibrated: 2/26/2015;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

Dipole E-Field measurement/835 MHz/Hearing Aid Compatibility Test at 15mm distance
(41x361x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 122.9 V/m; Power Drift = 0.01 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 110.2 V/m
Near-field category: M4 (AWF 0 dB)
                                         PMF scaled E-field
                                          Grid 1 M4 Grid 2 M4 Grid 3 M4
                                          107.9 V/m        109.2 V/m   107.5 V/m
                                          Grid 4 M4        Grid 5 M4   Grid 6 M4
                                          62.59 V/m        64.23 V/m   63.77 V/m
                                          Grid 7 M4        Grid 8 M4   Grid 9 M4
                                          107.8 V/m        110.2 V/m   108.7 V/m
Cursor:
Total = 110.2 V/m
E Category: M4
Location: -0.5, 70.5, 9.7 mm




              0 dB = 110.2 V/m = 40.84 dBV/m


Test Laboratory: UL Verification Services Inc. SAR Lab C                           Date: 5/12/2015

HAC-RF Emission
Communication System: UID 0, CW; Frequency: 1880 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2339; ConvF(1, 1, 1); Calibrated: 2/26/2015;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

Dipole E-Field measurement/1880 MHz/Hearing Aid Compatibility Test at 15mm
distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 132.3 V/m; Power Drift = 0.01 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 89.35 V/m
Near-field category: M3 (AWF 0 dB)
                                         PMF scaled E-field
                                          Grid 1 M3 Grid 2 M3 Grid 3 M3
                                          83.98 V/m        84.89 V/m   83.65 V/m
                                          Grid 4 M3        Grid 5 M3   Grid 6 M3
                                          71.14 V/m        72.36 V/m   71.84 V/m
                                          Grid 7 M3        Grid 8 M3   Grid 9 M3
                                          87.87 V/m        89.35 V/m   87.88 V/m
Cursor:
Total = 89.35 V/m
E Category: M3
Location: 0, 30.5, 9.7 mm




             0 dB = 89.35 V/m = 39.02 dBV/m



Document Created: 2015-05-13 17:37:59
Document Modified: 2015-05-13 17:37:59

© 2025 FCC.report