Test Laboratory: UL Verification Services Inc. SAR Lab E                     Date/Time: 4/23/2015 11:34:11 PM

CDMA BC0

Frequency: 848.31 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                  3
Medium parameters used (interpolated): f = 848.31 MHz; σ = 0.926 S/m; ε r = 42.021; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1257; Calibrated: 9/29/2014
- Probe: EX3DV4 - SN3772; ConvF(8.58, 8.58, 8.58); Calibrated: 2/23/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM with CRP; Type: SAM;

RHS/Touch_1xRTT_RC3 SO55_Ch 777/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 1.25 W/kg

RHS/Touch_1xRTT_RC3 SO55_Ch 777/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 36.875 V/m; Power Drift = -0.01 dB
Peak SAR (extrapolated) = 1.50 W/kg
SAR(1 g) = 1.11 W/kg; SAR(10 g) = 0.784 W/kg
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 1.28 W/kg




                      0 dB = 1.28 W/kg = 1.07 dBW/kg




                                                                                                               Plot No. 1


Test Laboratory: UL Verification Services Inc. SAR Lab E                     Date/Time: 4/24/2015 12:17:07 AM

CDMA BC0

Frequency: 836.52 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                 3
Medium parameters used (interpolated): f = 836.52 MHz; σ = 0.982 S/m; εr = 53.963; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1257; Calibrated: 9/29/2014
- Probe: EX3DV4 - SN3772; ConvF(8.46, 8.46, 8.46); Calibrated: 2/23/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 A; Type: QD OVA 002 AA; Serial: 1180

Rear/1xRTT_RC3 SO32_Ch 384/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.853 W/kg

Rear/1xRTT_RC3 SO32_Ch 384/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 26.504 V/m; Power Drift = -0.13 dB
Peak SAR (extrapolated) = 0.999 W/kg
SAR(1 g) = 0.742 W/kg; SAR(10 g) = 0.525 W/kg
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.861 W/kg




                      0 dB = 0.861 W/kg = -0.65 dBW/kg




                                                                                                               Plot No. 2


Test Laboratory: UL Verification Services Inc. SAR Lab H                    Date/Time: 4/23/2015 12:09:31 PM

CDMA BC1

Frequency: 1880 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                               3
Medium parameters used: f = 1880 MHz; σ = 1.42 S/m; εr = 38.812; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1258; Calibrated: 5/15/2014
- Probe: EX3DV4 - SN7335; ConvF(8.21, 8.21, 8.21); Calibrated: 3/13/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: SAM with CRP v5.0; Type: QD000P40CD; Serial: 1830

RHS/Touch_1xRTT_RC3 SO55_Ch 600/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 1.27 W/kg

RHS/Touch_1xRTT_RC3 SO55_Ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 28.798 V/m; Power Drift = -0.12 dB
Peak SAR (extrapolated) = 1.89 W/kg
SAR(1 g) = 1.21 W/kg; SAR(10 g) = 0.713 W/kg
Maximum value of SAR (measured) = 1.51 W/kg




                      0 dB = 1.51 W/kg = 1.79 dBW/kg




                                                                                                            Plot No. 3


Test Laboratory: UL Verification Services Inc. SAR Lab H                    Date/Time: 4/23/2015 4:08:13 PM

CDMA BC1

Frequency: 1908.75 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                   3
Medium parameters used (interpolated): f = 1908.75 MHz; σ = 1.583 S/m; ε r = 51.351; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1258; Calibrated: 5/15/2014
- Probe: EX3DV4 - SN7335; ConvF(7.9, 7.9, 7.9); Calibrated: 3/13/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: ELI v5.0 B; Type: QDOVA002AA; Serial: 1248

Rear/1xRTT_RC3 SO32_Ch 1175/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 1.42 W/kg

Rear/1xRTT_RC3 SO32_Ch 1175/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 30.562 V/m; Power Drift = -0.14 dB
Peak SAR (extrapolated) = 1.81 W/kg
SAR(1 g) = 1.13 W/kg; SAR(10 g) = 0.649 W/kg
Info: Interpolated medium parameters used for SAR evaluation.




                      0 dB = 1.42 W/kg = 1.52 dBW/kg