                 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen
                 Branch

                                                                                 Report No.: ZR/2019/6003102
                                                                                 Page:       1 of 7




                 RF Exposure Evaluation Report
Application No.:                      ZR/2019/60031
Applicant:                            Fibocom Wireless Inc.
Address of Applicant                  5/F,Tower A,Technology Building II,1057 Nanhai Avenue,Shenzhen,China
Manufacturer:                         Fibocom Wireless Inc.
Address of Manufacturer               5/F,Tower A,Technology Building II,1057 Nanhai Avenue,Shenzhen,China
Factory:                              Shenzhen Eternity Technology Co.,Ltd
                                      1F,2F,4F Building A2, Yingzhan Industrial Zone, Longtian Community,
Address of Factory:                   Longtian Road, Pingshan District, Shenzhen, Guangdong Province, P.R.
                                      China
Product Name:                         NB-IoT Module
Model No.(EUT):                       N510-GL
Trade Mark:                           Fibocom
FCC ID:                               ZMON510GL
Standards:                            47 CFR Part 2
                                      47 CFR Part 22 subpart H
                                      47 CFR Part 24 subpart E
                                      47 CFR Part 27 subpart C
Date of Receipt:                      2019/6/27
Date of Test:                         2019/6/28 to 2019/8/22
Date of Issue:                        2019/8/22
Test Result:                           PASS*
*      In the configuration tested, the EUT complied with the standards specified above.




    Authorized Signature:




          Derek Yang
    Wireless Laboratory Manager


                SGS-CSTC Standards Technical Services Co.,Ltd.Shenzhen
                Branch
                                                               Report No.: ZR/2019/6003102
                                                               Page:       2 of 7




1 Version

                                       Revision Record
      Version        Chapter        Date                   Modifier       Remark

      01                            2019/8/22                             Original




  Authorized for issue by:




                                                                       2019/8/22


                               Mike Hu /Project Engineer


                                                                       2019/8/22


                               David Chen /Reviewer


                               SGS-CSTC Standards Technical Services Co.,Ltd.Shenzhen
                               Branch
                                                                                                                     Report No.: ZR/2019/6003102
                                                                                                                     Page:       3 of 7


                                                                                   Contents
1       VERSION ......................................................................................................................................................................2

CONTENTS ............................................................................................................................................................................3

2       GENERAL INFORMATION ........................................................................................................................................4
    2.1          CLIENT INFORMATION ...........................................................................................................................................4
    2.2          GENERAL DESCRIPTION OF EUT .........................................................................................................................4
    2.3          TEST LOCATION ....................................................................................................................................................5
    2.4          TEST FACILITY ......................................................................................................................................................5
    2.5          DEVIATION FROM STANDARDS .............................................................................................................................5
    2.6          ABNORMALITIES FROM STANDARD CONDITIONS .................................................................................................5
    2.7          OTHER INFORMATION REQUESTED BY THE CUSTOMER ......................................................................................5
3       RF EXPOSURE EVALUATION .................................................................................................................................6
    3.1     RF EXPOSURE COMPLIANCE REQUIREMENT ......................................................................................................6
       3.1.1 Limits ...............................................................................................................................................................6
       3.1.2 Test Procedure ...............................................................................................................................................6
       3.1.3 EUT RF Exposure Evaluation ......................................................................................................................7


                    SGS-CSTC Standards Technical Services Co.,Ltd.Shenzhen
                    Branch
                                                                   Report No.: ZR/2019/6003102
                                                                   Page:       4 of 7




2     General Information
2.1 Client Information
Applicant:                  Fibocom Wireless Inc.
Address of Applicant:       5/F, Tower A, Technology Building II, 1057 Nanhai Avenue, Shenzhen, China
Manufacturer:               Fibocom Wireless Inc.
Address of Manufacturer:    5/F, Tower A, Technology Building II, 1057 Nanhai Avenue, Shenzhen, China
Factory:                    Shenzhen Eternity Technology Co., Ltd
Address of Factory:         1F, 2F, 4F Building A2, Yingzhan Industrial Zone, Longtian Community,
                            Longtian Road, Pingshan District, Shenzhen, Guangdong Province, P.R. China

2.2 General Description of EUT
EUT Description:           NB-IoT Module
Model No.:                 N510-GL
Trade Mark:                Fibocom
Hardware Version:          V1.0.0
Software Version:          54000.1000.35.03.07.03
Sample Type:                 Portable Device,    Module
Antenna Type:                External,     Integrated
                           LTE NB1 Band 2:3.22dBi;
                           LTE NB1 Band 4:2.64dBi;
                           LTE NB1 Band 5:1.12dBi;
                           LTE NB1 Band 12:1.20dBi;
                           LTE NB1 Band 13:1.11dBi;
Antenna Gain:
                           LTE NB1 Band 17:1.41dBi;
                           LTE NB1 Band 25:2.92dBi;
                           LTE NB1 Band 66: 2.64dBi;
                           LTE NB1 Band 71:1.20dBi;
                           LTE NB1 Band 85:1.20dBi;


                 SGS-CSTC Standards Technical Services Co.,Ltd.Shenzhen
                 Branch
                                                                     Report No.: ZR/2019/6003102
                                                                     Page:       5 of 7


2.3 Test Location
    All tests were performed at:
    SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch
    No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China
    518057
    Telephone: +86 (0) 755 2601 2053    Fax: +86 (0) 755 2671 0594
    No tests were sub-contracted.

2.4 Test Facility
    The test facility is recognized, certified, or accredited by the following organizations:
    • CNAS (No. CNAS L2929)
    CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
    Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
    Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
    Laboratories) for the competence in the field of testing.
    • A2LA (Certificate No. 3816.01)
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
    American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
    • VCCI
    The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
    Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
    Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been
    registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: G-
    20026, R-14188, C-12383 and T-11153 respectively.
    • FCC –Designation Number: CN1178
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized as
    an accredited testing laboratory.
    Designation Number: CN1178. Test Firm Registration Number: 406779.
    • Industry Canada (IC)
    Two 3m Semi-anechoic chambers and the 10m Semi-anechoic chamber of SGS-CSTC Standards
    Technical Services Co., Ltd. Shenzhen Branch EMC Lab have been registered by Certification and
    Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 4620C-1,
    4620C-2, 4620C-3.

2.5 Deviation from Standards
    None.

2.6 Abnormalities from Standard Conditions
    None.

2.7 Other Information Requested by the Customer
    None.


                      SGS-CSTC Standards Technical Services Co.,Ltd.Shenzhen
                      Branch
                                                                       Report No.: ZR/2019/6003102
                                                                       Page:       6 of 7


3 RF Exposure Evaluation
3.1 RF Exposure Compliance Requirement
3.1.1 Limits
    Frequency range Electric field strength Magnetic field strength Power density Averaging time
         (MHz)               (V/m)                  (A/m)             (mW/cm2)      (minutes)
                              (A) Limits for Occupational/Controlled Exposures
          0.3-3.0                 614                     1.63                 *(100)              6
          3.0-30                 1842/f                   4.89/f              *(900/f2)            6
          30-300                  61.4                    0.163                  1.0               6
        300-1500                      /                     /                   f/300              6
      1500-100,000                    /                     /                    5                 6
                          (B) Limits for General Population/Uncontrolled Exposure
         0.3-1.34                 614                     1.63                 *(100)             30
         1.34-30                  824/f                   2.19/f              *(180/f2)           30
          30-300                  27.5                    0.073                  0.2              30
        300-1500                      /                     /                  f/1500             30
      1500-100,000                    /                     /                    1.0              30
   F=frequency in MHz
   *=Plane-wave equivalent power density
   RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of the FCC rules.
   The emissions should be within the limits at 300kHz in Table 1 of 1.1310(use the 300kHz limits for
   150kHz:614V/m,1.63A/m).
Friis Formula
Friis transmission formula: Pd = (Pout*G)/(4* Pi * R 2)
Where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416

R = distance between observation point and center of the radiator in cm
Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total power input to the
antenna, through the calculation, we will know the distance r where the MPE limit is reached.

3.1.2 Test Procedure
      Software provided by client enabled the EUT to transmit data at lowest, middle and highest channel
      individually.


                        SGS-CSTC Standards Technical Services Co.,Ltd.Shenzhen
                        Branch
                                                                                                 Report No.: ZR/2019/6003102
                                                                                                 Page:       7 of 7



3.1.3 EUT RF Exposure Evaluation
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 2.0 / 2.0 in linear scale.
Output Power Into Antenna & RF Exposure Evaluation Distance:
                                        Max
                                                Output                              Power
                                     Conducted                         Output                           Gain
                  Frequenc Antenna              Power    EIRP(ERP)                  Density                          Gain       Max Gain
   Operating                          Average                           Power                  Limit  according
                      y     Gain                  to        Limit                  at R = 20                       according    Allowed    conclusion
     Band                              Output                        to Antenna              (mW/cm2) to EIRP
                    (MHz)   (dBi)              Antenna     (dBm)                      cm                          to Pd (dBi)    (dBi)
                                       Power                            (mw)                            (dBi)
                                                (dBm)                             (mW/cm2)
                                       (dBm)
 LTE NB1 Band 2    1850.1   3.22       24.00    27.22      33.00     251.1886      0.1049    1.0000      9.00       13.01         9.00       Pass
 LTE NB1 Band 4    1710.1   2.64       24.00    26.64      30.00     251.1886      0.0918    1.0000      6.00       13.01         6.00       Pass
 LTE NB1 Band 5    824.10   1.12       24.00    22.97      38.45     251.1886      0.0647    0.5494     16.60       10.41        10.41       Pass
LTE NB1 Band 12    699.10   1.20       24.00    23.05      34.77     251.1886      0.0659    0.4661     12.92       9.69          9.69       Pass
LTE NB1 Band 13    777.10   1.11       24.00    22.96      34.77     251.1886      0.0645    0.5181     12.92       10.15        10.15       Pass
LTE NB1 Band 17    704.1    1.41       24.00    23.26      34.77     251.1886      0.0691    0.4694     12.92       9.72          9.72       Pass
LTE NB1 Band 25    1850.1   2.92       24.00    26.92      33.00     251.1886      0.0979    1.0000      9.00       13.01         9.00       Pass
LTE NB1 Band 66    1710.1   2.64       24.00    25.20      30.00     251.1886      0.0659    1.0000      6.00       13.01         6.00       Pass
LTE NB1 Band 71    663.1    1.20       24.00    23.05      34.77     251.1886      0.0659    0.4421     12.92       9.46          9.46       Pass
LTE NB1 Band 85    698.1    1.20       24.00    21.85      34.77     251.1886      0.0500    0.4654     12.92       9.69          9.69       Pass



Note: Refer to report No. ZR/2019/6003101 for EUT test Max Conducted Output Power value.



Document Created: 2019-09-02 10:57:30
Document Modified: 2019-09-02 10:57:30