RF Exposure

FCC ID: ZKJ-WCATA007

RF Exposure Info

Download: PDF
FCCID_4188954

                              CTK Co., Ltd.
                (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea
                        Tel: +82-31-339-9970       Fax: +82-31-624-9501
                                          www.e-ctk.com




         RF EXPOSURE EVALUATION



Applicant              : Haier US Appliance Solutions, Inc.

                       : Appliance Park, AP2-226, Louisville, KY 40225,
Applicant Address
                        United States

Kind of Product        : Wi-Fi Module

Equipment
                       : WCATA007
model name

FCC ID                 : ZKJ-WCATA007

Certification
                       : 10229A-WCATA007
Number IC

Antenna type           : Chip Antenna


Antenna Gain           : 1.47 dBi




                                                                                     Page 1 of 4


                                             CTK Co., Ltd.
                        (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea
                                Tel: +82-31-339-9970       Fax: +82-31-624-9501
                                                  www.e-ctk.com




Standard Requirement

     The following RF exposure procedures are applicable :


     -      FCC Rules
          Part 1.1310 Radiofrequency radiation exposure limits

          Table 1 below sets forth limits for Maximum Permissible Exposure (MPE) to
          radiofrequency electromagnetic fields.

                           Table 1—Limits for Maximum Permissible Exposure (MPE)
         Frequency range    Electric field strength   Magnetic field strength   Power density      Averaging time
              (MHz)                 (V/m)                     (A/m)               (mW/cm2)            (minutes)
                                       (A) Limits for Occupational/Controlled Exposure
             0.3-3.0                 614                       1.63                  *100                 6
                                                                                             2
             3.0-30                 1842/f                    4.89/f                *900/f                6
             30-300                  61.4                     0.163                   1.0                 6
            300-1,500                                                                f/300                6
          1,500-100,000                                                                5                  6
                                  (B) Limits for General Population/Uncontrolled Exposure
             0.3-1.34                614                       1.63                  *100                 30
                                                                                             2
             1.34-30                 824/f                    2.19/f                *180/f                30
             30-300                  27.5                     0.073                   0.2                 30
            300-1,500                                                               f/1500                30
          1,500-100,000                                                               1.0                 30
     f = frequency in MHz
     * = Plane-wave equivalent power density


     -      ISED Rules
          RSS-102 Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All
          Frequency Bands)

                Table 4 : RF Field Strength Limits for Devices Used by the General Public
                                        (Uncontrolled Environment)
         Frequency Range        Electric Field            Magnetic Field        Power Density      Reference Period
              (MHz)              (V/m rms)                  (A/m rms)              (W/m2)             (minutes)

            0.003-10                  83                        90                     -            Instantaneous*
             0.1-10                    -                      0.73/ ƒ                  -                  6**
             1.1-10                87/ ƒ 0.5                     -                     -                  6**
              10-20                 27.46                     0.0728                  -2                  6
              20-48               58.07/ ƒ0.25             0.1540/ ƒ0.25          8.944/ ƒ0.5             6
             48-300                 22.06                    0.05852                1.291                 6
            300-6000             3.142 ƒ 0.3417          0.008335 ƒ 0.3417      0.02619 ƒ 0.6834          6
           6000-15000                61.4                     0.163                   10                  6
          15000-150000               61.4                     0.163                   10             616000/ ƒ 1.2
                                             0.5                     -4   0.5                -5
          150000-300000           0.158 ƒ                 4.21 x 10 ƒ            6.67 x 10 ƒ          616000/ƒ1.2

     Note: ƒ is frequency in MHz.
     * Based on nerve stimulation (NS).
     ** Based on specific absorption rate (SAR).

                                                                                                                      Page 2 of 4


                                 CTK Co., Ltd.
                   (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea
                           Tel: +82-31-339-9970       Fax: +82-31-624-9501
                                             www.e-ctk.com




MPE Calculations


The EUT will only be used with a separation of 20 centimeters or greater between the antenna
and the body of the user. The MPE calculation for this exposure is shown below.

The peak radiated output power (EIRP) is calculated as follows:

EIRP = P + G                          Where,
                                      P = Power input to the antenna (mW)
                                      G = Power gain of the antenna (dBi)




The numeric gain(G) of the antenna with a gain specified in dB is determined by:
G = Log-1 (dB antenna gain / 10)




Power density at the specific separation:

S = PG/(4R2π)                         Where,
                                          S = Maximum power density (mW/cm2)
                                          P = Power input to the antenna (mW)
                                          G = Numeric power gain of the antenna
                                          R = Distance to the center of the radiation of the
                                      antenna
                                              (20cm = limit for MPE)




Estimated safe separation:

R = √(PG / 4π)                        Where,
                                          P = Power input to the antenna (mW)
                                          G = Numeric power gain of the antenna
                                          R = Distance to the center of the radiation of the
                                      antenna
                                            (20cm = limit for MPE)




                                                                                        Page 3 of 4


                               CTK Co., Ltd.
                 (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea
                         Tel: +82-31-339-9970       Fax: +82-31-624-9501
                                           www.e-ctk.com




RF Exposure Results

                                                                Power Density
                        P            G           EIRP
     Mode                                                      FCC            ISED    R (cm)
                     (dBm)         (dBi)        (dBm)
                                                           (mW/cm2)         (W/m2)
    802.11b           19.85                     21.32        0.0270          0.0270
    802.11g           14.35        1.47         15.82        0.0076          0.0076      20
  802.11n HT20        14.26                     15.73        0.0074          0.0074




                                                                                      Page 4 of 4



Document Created: 2019-02-27 14:09:40