Report BLE rev.1

FCC ID: ZKJ-KITCHENHUB1

Test Report

Download: PDF
FCCID_4178186

Haier US Appliance Solutions, Inc.
RF TEST REPORT
Report Type:
FCC Part 15.247 & ISED RSS-247 RF report


Model:
UVH13012M1SS


Additional Model:
See Page 2


REPORT NUMBER:
190100007SHA-005


ISSUE DATE:
February 18, 2019


DOCUMENT CONTROL NUMBER:
TTRF15.247-02_V1 © 2018 Intertek


                                                                                                                 Intertek Testing Services Shanghai
                                                                                                       Building No.86, 1198 Qinzhou Road (North)
                                                                                                                      Caohejing Development Zone
                                                                                                                           Shanghai 200233, China

                                                                                                                      Telephone: 86 21 6127 8200
TEST REPORT                                                                                                                   www.intertek.com
                                                                                                                   Report no.: 190100007SHA-005


 Applicant:                              Haier US Appliance Solutions, Inc.
                                         Appliance Park AP2-226, Louisville, KY, 40225, United States
 Manufacturer:                           Haier US Appliance Solutions, Inc.
                                         Appliance Park AP2-226, Louisville, KY, 40225, United States
 Product Name:                           KITCHEN HUB
 Type/Model:                             UVH13012M1SS
 Additional Model:                       UVH13012M2SS, UVH13012M3SS, UVH13012M4SS, UVH13012M5SS,
                                         UVH13013M1DS, UVH13013M2DS, UVH13013M3DS, UVH13013M4DS,
                                         UVH13013M5DS, UVH13014M1WM, UVH13014M2WM, VH13014M3WM,
                                         UVH13014M4WM, UVH13014M5WM, UVH13013M1TS, UVH13013M2TS,
                                         UVH13013M3TS, UVH13013M4TS, UVH13013M5TS
 FCC ID:                                 ZKJ-KITCHENHUB1
 IC:                                     10229A-KITCHENHUB1



SUMMARY:
 The equipment complies with the requirements according to the following standard(s) or Specification:
 47CFR Part 15 (2017): Radio Frequency Devices (Subpart C)

 ANSI C63.10 (2013): American National Standard of Procedures for Compliance Testing of Unlicensed Wireless
 Devices

 RSS‐247 Issue 2 (February 2017): Digital Transmission Systems (DTSs), Frequency Hopping Systems (FHSs) and
 Licence-Exempt Local Area Network (LE-LAN) Devices

 RSS‐Gen Issue 5 (April 2018): General Requirements for Compliance of Radio Apparatus




PREPARED BY:                                                                REVIEWED BY:




Project Engineer                                                            Reviewer
Wade Zhang                                                                  Daniel Zhao

This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's
responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the
Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to
permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or
advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this
report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under
an Intertek certification program.

 TTRF15.247-02_V1 © 2018 Intertek                                  Page 2 of 31


                                                                                                                               Report No.: 190100007SHA-005



TEST REPORT

                                                                             Content
REVISION HISTORY................................................................................................................................................ 5
MEASUREMENT RESULT SUMMARY ..................................................................................................................... 6
1        GENERAL INFORMATION ............................................................................................................................. 7
     1.1     DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ..................................................................................................... 7
     1.2     TECHNICAL SPECIFICATION .................................................................................................................................... 7
     1.3     ANTENNA INFORMATION....................................................................................................................................... 7
     1.4     DESCRIPTION OF TEST FACILITY .............................................................................................................................. 8
2        TEST SPECIFICATIONS ................................................................................................................................... 9
     2.1     STANDARDS OR SPECIFICATION ............................................................................................................................... 9
     2.2     MODE OF OPERATION DURING THE TEST................................................................................................................... 9
     2.3     TEST SOFTWARE LIST .......................................................................................................................................... 10
     2.4     TEST PERIPHERALS LIST ....................................................................................................................................... 10
     2.5     TEST ENVIRONMENT CONDITION:.......................................................................................................................... 10
     2.6     INSTRUMENT LIST .............................................................................................................................................. 11
     2.7     MEASUREMENT UNCERTAINTY ............................................................................................................................. 12
3        MINIMUM 6DB BANDWIDTH..................................................................................................................... 13
     3.1     LIMIT .............................................................................................................................................................. 13
     3.2     MEASUREMENT PROCEDURE ............................................................................................................................... 13
     3.3     TEST CONFIGURATION ........................................................................................................................................ 13
     3.4     TEST RESULTS OF MINIMUM 6DB BANDWIDTH ....................................................................................................... 13
4        MAXIMUM CONDUCTED OUTPUT POWER AND E.I.R.P. ............................................................................. 14
     4.1     LIMIT .............................................................................................................................................................. 14
     4.2     MEASUREMENT PROCEDURE ............................................................................................................................... 14
     4.3     TEST CONFIGURATION ........................................................................................................................................ 14
     4.4     TEST RESULTS OF MAXIMUM CONDUCTED OUTPUT POWER........................................................................................ 14
5        POWER SPECTRUM DENSITY ..................................................................................................................... 15
     5.1     LIMIT .............................................................................................................................................................. 15
     5.2     MEASUREMENT PROCEDURE ............................................................................................................................... 15
     5.3     TEST CONFIGURATION ........................................................................................................................................ 15
     5.4     TEST RESULTS OF POWER SPECTRUM DENSITY ......................................................................................................... 15
6        EMISSION OUTSIDE THE FREQUENCY BAND .............................................................................................. 16
     6.1     LIMIT .............................................................................................................................................................. 16
     6.2     MEASUREMENT PROCEDURE ............................................................................................................................... 16
     6.3     TEST CONFIGURATION ........................................................................................................................................ 17
     6.4     THE RESULTS OF EMISSION OUTSIDE THE FREQUENCY BAND........................................................................................ 17
7        RADIATED EMISSIONS IN RESTRICTED FREQUENCY BANDS ........................................................................ 18
     7.1     LIMIT .............................................................................................................................................................. 18
     7.2     MEASUREMENT PROCEDURE ............................................................................................................................... 18
     7.3     TEST CONFIGURATION ........................................................................................................................................ 20
     7.4     TEST RESULTS OF RADIATED EMISSIONS ................................................................................................................. 22
8        POWER LINE CONDUCTED EMISSION......................................................................................................... 26
     8.1     LIMIT .............................................................................................................................................................. 26
     8.2     TEST CONFIGURATION ........................................................................................................................................ 26
     8.3     MEASUREMENT PROCEDURE ............................................................................................................................... 27

    TTRF15.247-02_V1 © 2018 Intertek                                             Page 3 of 31


                                                                                                                              Report No.: 190100007SHA-005



TEST REPORT

     8.4    TEST RESULTS OF POWER LINE CONDUCTED EMISSION............................................................................................... 28
9        OCCUPIED BANDWIDTH ............................................................................................................................ 30
     9.1    LIMIT .............................................................................................................................................................. 30
     9.2    MEASUREMENT PROCEDURE ............................................................................................................................... 30
     9.3    TEST CONFIGURATION ........................................................................................................................................ 30
     9.4    THE RESULTS OF OCCUPIED BANDWIDTH ................................................................................................................ 30
10       ANTENNA REQUIREMENT .......................................................................................................................... 31




    TTRF15.247-02_V1 © 2018 Intertek                                            Page 4 of 31


                                                                              Report No.: 190100007SHA-005



TEST REPORT

                                             Revision History

     Report No.                    Version              Description                      Issued Date
 190100007SHA-005                  Rev. 01          Initial issue of report            February 18, 2019




TTRF15.247-02_V1 © 2018 Intertek                Page 5 of 31


                                                                           Report No.: 190100007SHA-005



TEST REPORT

                                    Measurement result summary


                  TEST ITEM                FCC REFERANCE        IC REFERANCE             RESULT

                                                               RSS-247 Issue 2
        Minimum 6dB Bandwidth               15.247(a)(2)                                   Pass
                                                                  Clause 5.2
 Maximum conducted output power                                RSS-247 Issue 2
                                            15.247(b)(3)                                   Pass
           and e.i.r.p.                                           Clause 5.4
                                                               RSS-247 Issue 2
        Power spectrum density                15.247(e)                                    Pass
                                                                  Clause 5.2
                                                               RSS-247 Issue 2
Emission outside the frequency band           15.247(d)                                    Pass
                                                                  Clause 5.5
   Radiated Emissions in restricted          15.247(d),        RSS-Gen Issue 5
                                                                                           Pass
          frequency bands                  15.205&15.209       Clause 8.9&8.10
                                                               RSS-Gen Issue 5
    Power line conducted emission             15.207(a)                                    Pass
                                                                  Clause 8.8
                                                               RSS-Gen Issue 5
           Occupied bandwidth                      -                                      Tested
                                                                  Clause 6.6

          Antenna requirement                  15.203                  -                   Pass


Notes: 1: NA =Not Applicable
2. Determination of the test conclusion is based on IEC Guide 115 in consideration of measurement
uncertainty.
3: Additions, Deviations and Exclusions from Standards: None.




 TTRF15.247-02_V1 © 2018 Intertek              Page 6 of 31


                                                                               Report No.: 190100007SHA-005



TEST REPORT

1 GENERAL INFORMATION

1.1 Description of Equipment Under Test (EUT)

 Product name:                     KITCHEN HUB
 Type/Model:                       UVH13012M1SS
                                   UVH13012M2SS, UVH13012M3SS, UVH13012M4SS, UVH13012M5SS,
                                   UVH13013M1DS, UVH13013M2DS, UVH13013M3DS, UVH13013M4DS,
                                   UVH13013M5DS, UVH13014M1WM, UVH13014M2WM, VH13014M3WM,
                                   UVH13014M4WM, UVH13014M5WM, UVH13013M1TS, UVH13013M2TS,
 Additional Model:                 UVH13013M3TS, UVH13013M4TS, UVH13013M5TS
                                   The EUT is a kitchen hood which was install wireless modules, there have
                                   20 models, and they are electrically identical except different PCB
                                   silkscreen, different software version and the man-machine interface (not
                                   change the RF parameters), appearance skin and surface treatment
 Description of EUT:               process.
 Rating:                           120VAC 60Hz, 4A
 Software Version:                 /
 Hardware Version:                 /
 Sample received date:             January 10, 2019
 Date of test:                     January 10, 2019 ~ January 31, 2019

1.2 Technical Specification

 Frequency Range:                  2400MHz ~ 2483.5MHz
 Support Standards:                Bluetooth LE
 Type of Modulation:               GFSK
 Channel Number:                   40 (0-39)
 Data Rate:                        1Mbps
 Power Class:                      Class II
 Channel Separation:               2 MHz

1.3 Antenna information

 Antenna No.             Model                 Antenna type              Antenna Gain             Note
       1                    /                     Internal                  3.1dBi




TTRF15.247-02_V1 © 2018 Intertek                      Page 7 of 31


                                                                           Report No.: 190100007SHA-005



TEST REPORT


1.4 Description of Test Facility

 Name:                   Intertek Testing Services Shanghai

 Address:                Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China

 Telephone:              86 21 61278200

 Telefax:                86 21 54262353



 The test facility is    CNAS Accreditation Lab
 recognized,             Registration No. CNAS L0139
 certified, or
                         FCC Accredited Lab
 accredited by these
                         Designation Number: CN1175
 organizations:
                         IC Registration Lab
                         Registration code No.: 2042B-1
                         VCCI Registration Lab
                         Registration No.: R-4243, G-845, C-4723, T-2252
                         A2LA Accreditation Lab
                         Certificate Number: 3309.02




TTRF15.247-02_V1 © 2018 Intertek                   Page 8 of 31


                                                                                     Report No.: 190100007SHA-005



TEST REPORT

2 TEST SPECIFICATIONS

2.1 Standards or specification

47CFR Part 15 (2017)
ANSI C63.10 (2013)
RSS-247 Issue 2 (February 2017)
RSS-Gen Issue 5 (April 2018)
KDB 558074 (v05)



2.2 Mode of operation during the test

While testing transmitting mode of EUT, the internal modulation and continuously transmission was
applied.

The lowest, middle and highest channel were tested as representatives.
                 Frequency Band (MHz)                                              2402 ~ 2480
                Frequency                     Frequency                     Frequency                 Frequency
 Channel                            Channel                  Channel                      Channel
                  (MHz)                         (MHz)                         (MHz)                     (MHz)
      0            2402               10         2422               20         2442          30          2462
      1            2404               11         2424               21         2444          31          2464
      2            2406               12         2426               22         2446          32          2466
      3            2408               13         2428               23         2448          33          2468
      4            2410               14         2430               24         2450          34          2470
      5            2412               15         2432               25         2452          35          2472
      6            2414               16         2434               26         2454          36          2474
      7            2416               17         2436               27         2456          37          2476
      8            2418               18         2438               28         2458          38          2478
      9            2420               19         2440               29         2460          39          2480

Data rate VS Power:
The test setting software is offered by the manufactory. The pre-scan for the conducted power with all
rates in each modulation and bands was used, and the worst case was found and used in all test cases.
                                     Test software and Power Setting parameter
          Test Software                                                  adb command

          Working Mode                                                       BLE

           Test Channel                         2402MHz                       2440MHz               2480MHz
          Power Setting                           max                              max               max




 TTRF15.247-02_V1 © 2018 Intertek                    Page 9 of 31


                                                                               Report No.: 190100007SHA-005



TEST REPORT


The UVH13012M1SS was chosen as a representative, and there have the following test mode:

Radiated test mode:
  Mode 1: EUT transmitted signal with internal antenna;

Conducted test mode:
  Mode 2: EUT transmitted signal from PCBA RF port connected to SPA directly;

We have verified all test modes and choose the worst mode 1 for radiated test and mode 2 for
conducted test as representatively to list the results in this report.

2.3 Test software list

     Test Items                     Software             Manufacturer                    Version

Conducted emission                  ESxS-K1                      R&S                      V2.1.0

 Radiated emission                    ES-K1                      R&S                      V1.71


2.4 Test peripherals list

      Item No.                        Name             Band and Model                  Description

           1                   Laptop computer               HP, 6470b                AC 230V 50Hz




2.5 Test environment condition:

                         Test items                              Temperature               Humidity
                Minimum 6dB Bandwidth
   Maximum conducted output power and e.i.r.p.

                Power spectrum density                              23C                   52% RH
         Emission outside the frequency band

                   Occupied bandwidth
 Radiated Emissions in restricted frequency bands                   22C                   55% RH

            Power line conducted emission                           21C                   52% RH




 TTRF15.247-02_V1 © 2018 Intertek                Page 10 of 31


                                                                          Report No.: 190100007SHA-005



TEST REPORT


2.6 Instrument list

Conducted Emission
Used          Equipment              Manufacturer               Type       Internal no.    Due date
             Test Receiver              R&S                   ESCS 30        EC 2107      2019-07-15
                A.M.N.                  R&S                   ESH2-Z5        EC 3119      2019-11-30
            Shielded room             Zhongyu                     -          EC 2838      2020-01-07
Radiated Emission
Used          Equipment              Manufacturer              Type        Internal no.    Due date
                 Test Receiver            R&S                 ESIB 26        EC 3045      2019-09-12
                Bilog Antenna            TESEQ               CBL 6112D       EC 4206      2019-06-10
                Horn antenna              R&S                 HF 906         EC 3049      2019-11-17
                Horn antenna              ETS                  3117         EC 4792-1     2020-01-09
                Horn antenna             TOYO                HAP18-26W      EC 4792-3     2020-07-09
                 Pre-amplifier            R&S                Pre-amp 18      EC5262       2019-06-10
          Semi-anechoic chamber     Albatross project            -           EC 3048      2019-07-31
RF test
Used              Equipment          Manufacturer              Type        Internal no.    Due date
             PXA Signal Analyzer        Keysight              N9030A         EC 5338      2019-03-05
             PXA Signal Analyzer        Keysight              N9030B         EC 6078      2019-12-22
                Power sensor            Agilent               U2021XA       EC 5338-1     2019-03-05
          Vector Signal Generator       Agilent               N5182B         EC 5175      2019-03-05
      MXG Analog Signal Generator       Agilent               N5181A        EC 5338-2     2019-03-05
                 Test Receiver            R&S                  ESCI 7        EC 4501      2019-09-12
Additional instrument
Used            Equipment            Manufacturer              Type        Internal no.    Due date
            Therom-Hygrograph            ZJ1-2A               S.M.I.F.       EC 3783      2019-02-28
               Pressure meter             YM3            Shanghai Mengde     EC 3320      2019-07-01




 TTRF15.247-02_V1 © 2018 Intertek            Page 11 of 31


                                                                      Report No.: 190100007SHA-005



TEST REPORT


2.7 Measurement uncertainty

The measurement uncertainty represents an expanded uncertainty expressed at approximately
the 95% confidence level using a coverage factor of k=2.


                          Test item                           Measurement uncertainty


             Maximum peak output power                                0.74dB


 Radiated Emissions in restricted frequency bands
                                                                      4.90dB
                  below 1GHz

 Radiated Emissions in restricted frequency bands
                                                                      5.02dB
                  above 1GHz

        Emission outside the frequency band                           2.89dB


            Power line conducted emission                             3.19dB




 TTRF15.247-02_V1 © 2018 Intertek             Page 12 of 31


                                                                        Report No.: 190100007SHA-005



TEST REPORT


3 Minimum 6dB bandwidth
      Test result:           Pass

3.1 Limit

For systems using digital modulation techniques that may operate in the 902 - 928 MHz, 2400 - 2483.5
MHz and 5725 - 5850 MHz bands, the minimum 6 dB bandwidth shall be at least 500 kHz.



3.2 Measurement Procedure

a)   Set RBW = 100 kHz.
b)   Set the video bandwidth (VBW) ≥ 3 × RBW.
c)   Detector = Peak.
d)   Trace mode = max hold.
e)   Sweep = auto couple.
f)   Allow the trace to stabilize.
g)   Measure the maximum width of the emission that is constrained by the frequencies associated with
     the two outermost amplitude points (upper and lower frequencies) that are attenuated by 6 dB
     relative to the maximum level measured in the fundamental emission.



3.3 Test Configuration



                                    EUT                       Spectrum Analyzer




3.4 Test Results of Minimum 6dB bandwidth

       Please refer to Appendix A




 TTRF15.247-02_V1 © 2018 Intertek             Page 13 of 31


                                                                           Report No.: 190100007SHA-005



TEST REPORT


4 Maximum conducted output power and e.i.r.p.
      Test result:           Pass

4.1 Limit

For systems using digital modulation in the 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz bands:
1 W. (The e.i.r.p. shall not exceed 4 W)

If the transmitting antenna of directional gain greater than 6dBi is used, the power shall be reduced by
the amount in dB that the directional gain of the antenna exceeds 6dBi. If there have a beam forming
type, the limit should be the minimum of 30dBm and 30+ (6 –antenna gain-beam forming gain).



4.2 Measurement Procedure

a)   Set the RBW ≥ DTS bandwidth.
b)   Set VBW ≥ 3 × RBW.
c)   Set span ≥ 3 x RBW
d)   Sweep time = auto couple.
e)   Detector = peak.
f)   Trace mode = max hold.
g)   Allow trace to fully stabilize.
h)   Use peak marker function to determine the peak amplitude level.



4.3 Test Configuration



                                    EUT                         Spectrum Analyzer




4.4 Test Results of Maximum conducted output power

      Please refer to Appendix A




 TTRF15.247-02_V1 © 2018 Intertek               Page 14 of 31


                                                                           Report No.: 190100007SHA-005



TEST REPORT


5 Power spectrum density
      Test result:           Pass

5.1 Limit

For digitally modulated systems, the power spectral density conducted from the intentional radiator to
the antenna shall not be greater than 8dBm in any 3 kHz band during any time interval of continuous
transmission.

If the transmitting antenna of directional gain greater than 6dBi is used, the power shall be reduced by
the amount in dB that the directional gain of the antenna exceeds 6dBi. If there have a beam forming
type, the limit should be the minimum of 8dBm/MHz and 8+ (6 –antenna gain-beam forming gain).



5.2 Measurement Procedure

a)   Set analyzer center frequency to DTS channel center frequency.
b)   Set the span to 1.5 times the DTS bandwidth.
c)   Set the RBW to: 3 kHz ≤ RBW ≤ 100 kHz.
d)   Set the VBW ≥ 3 × RBW.
e)   Detector = peak.
f)   Sweep time = auto couple.
g)   Trace mode = max hold.
h)   Allow trace to fully stabilize.
i)   Use the peak marker function to determine the maximum amplitude level within the RBW.
j)   If measured value exceeds limit, reduce RBW (no less than 3 kHz) and repeat.


5.3 Test Configuration



                                    EUT                         Spectrum Analyzer




5.4 Test Results of Power spectrum density

      Please refer to Appendix A




 TTRF15.247-02_V1 © 2018 Intertek               Page 15 of 31


                                                                          Report No.: 190100007SHA-005



TEST REPORT


6 Emission outside the frequency band
      Test result:           Pass

6.1 Limit

In any 100 kHz bandwidth outside the frequency band in which the spread spectrum intentional radiator
is operating, the radio frequency power that is produced by the intentional radiator shall be at least 30
dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired
power.

6.2 Measurement Procedure

Reference level measurement
Establish a reference level by using the following procedure:
a) Set instrument center frequency to DTS channel center frequency.
b) Set the span to ≥ 1.5 times the DTS bandwidth.
c) Set the RBW = 100 kHz.
d) Set the VBW ≥ 3 x RBW.
e) Detector = peak.
f) Sweep time = auto couple.
g) Trace mode = max hold.
h) Allow trace to fully stabilize.
i) Use the peak marker function to determine the maximum PSD level.

Emission level measurement
a) Set the center frequency and span to encompass frequency range to be measured.
b) Set the RBW = 100 kHz.
c) Set the VBW ≥ 3 x RBW.
d) Detector = peak.
e) Sweep time = auto couple.
f) Trace mode = max hold.
g) Allow trace to fully stabilize.
h) Use the peak marker function to determine the maximum amplitude level.

Ensure that the amplitude of all unwanted emissions outside of the authorized frequency band
(excluding restricted frequency bands) are attenuated by at least the minimum requirements specified
in 11.1 a) or 11.1 b). Report the three highest emissions relative to the limit.




 TTRF15.247-02_V1 © 2018 Intertek              Page 16 of 31


                                                                   Report No.: 190100007SHA-005



TEST REPORT


6.3 Test Configuration



                                   EUT                   Spectrum Analyzer




6.4 The results of Emission outside the frequency band

      Please refer to Appendix A




TTRF15.247-02_V1 © 2018 Intertek         Page 17 of 31


                                                                        Report No.: 190100007SHA-005



TEST REPORT


7 Radiated Emissions in restricted frequency bands
      Test result:           Pass

7.1 Limit

The radiated emissions which fall in the restricted bands, must also comply with the radiated
emission limits specified showed as below:

                   Frequencies                  Field Strength           Measurement Distance
                      (MHz)                   (microvolts/meter)               (meters)
                  0.009 ~ 0.490                  2400/F(kHz)                     300
                  0.490 ~ 1.705                   24000/F(kHz)                      30
                  1.705 ~ 30.0                           30                         30
                     30 ~ 88                            100                         3
                     88 ~ 216                           150                         3
                    216 ~ 960                           200                         3
                   Above 960                            500                         3



7.2 Measurement Procedure
For Radiated emission below 30MHz:

a) The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter
   chamber room. The table was rotated 360 degrees to determine the position of the highest
   radiation.
b) The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on
   the top of a variable-height antenna tower.
c) Both X and Y axes of the antenna are set to make the measurement.
d) For each suspected emission, the EUT was arranged to its worst case and the rotatable table was
   turned from 0 degrees to 360 degrees to find the maximum reading.
e) The test-receiver system was set to Quasi-Peak Detect Function and Specified Bandwidth with
   Maximum Hold Mode.
NOTE:
 1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 9kHz at
    frequency below 30MHz.




 TTRF15.247-02_V1 © 2018 Intertek             Page 18 of 31


                                                                         Report No.: 190100007SHA-005



TEST REPORT


For Radiated emission above 30MHz:

a) The EUT was placed on the top of a rotating table 0.8 meters (for 30MHz ~ 1GHz) / 1.5 meters (for
   above 1GHz) above the ground at 3 meter chamber room for test. The table was rotated 360
   degrees to determine the position of the highest radiation.
b) The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on
   the top of a variable-height antenna tower.
c) The height of antenna is varied from one meter to four meters above the ground to determine the
   maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are
   set to make the measurement.
d) For each suspected emission, the EUT was arranged to its worst case and then the antenna was
   tuned to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360
   degrees to find the maximum reading.
e) The test-receiver system was set to quasi-peak detect function and specified bandwidth with
   maximum hold mode when the test frequency is below 1 GHz.
f)   The test-receiver system was set to peak and average detect function and specified bandwidth with
     maximum hold mode when the test frequency is above 1 GHz. If the peak reading value also meets
     average limit, measurement with the average detector is unnecessary.

Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for
    Quasi-peak detection (QP) at frequency below 1GHz.
2.   The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 3
     MHz for Peak detection (PK) at frequency above 1GHz.
3.   The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is ≥
     1/T (Duty cycle < 98%) or 3 x RBW (Duty cycle ≥ 98%) for Average detection (AV) at frequency above
     1GHz.
4.   All modes of operation were investigated and the worst-case emissions are reported




 TTRF15.247-02_V1 © 2018 Intertek              Page 19 of 31


                                                                         Report No.: 190100007SHA-005



TEST REPORT


7.3 Test Configuration

For Radiated emission below 30MHz:




               EUT&                        3m
               Support Units
                                   Turn Table

                  80cm



                                         Test Receiver




 For Radiated emission 30MHz to 1GHz:


                                                            Ant. Tower          1‐4m
                                                                                Variable
                EUT&                        3m
                Support Units
                                   Turn Table

                   80cm



                                          Test Receiver




TTRF15.247-02_V1 © 2018 Intertek            Page 20 of 31


                                                                        Report No.: 190100007SHA-005



TEST REPORT



 For Radiated emission above 1GHz:


                                                           Ant. Tower           1‐4m
                                                                                Variable
                EUT&                        3m
                Support Units
                                   Turn Table
                                                 Absorber
                   150cm



                                         Test Receiver




TTRF15.247-02_V1 © 2018 Intertek           Page 21 of 31


                                                                                              Report No.: 190100007SHA-005



TEST REPORT


7.4 Test Results of Radiated Emissions

Consider simultaneous transmission, EUT was tested with Zigbee, Z-wave and BLE on and off, and the
worst data was listed in the report. The low frequency, which started from 9 kHz to 30MHz, was pre-
scanned and the result which was 20dB lower than the limit line per 15.31(o) was not reported.

The worst waveform from 30MHz to 1000MHz is listed as below:

                                                                      Horizontal
        Level [dB礦/m]
     80


     70


     60


     50


     40                                                                 x                                          x
                                                                                         x       x
     30
                                                                                                        x
                                                                                   x
              x
     20                               x             x


     10


          0
              30M             50M             70M       100M                   200M    300M      500M       700M   1G
                                                            Frequency [Hz]

    x             MES 0111-H2_red
                  MES 0111-H2_pre
                  LIM FCC 15 F 3 QP       Field Strength QP


                                                                        Vertical
        Level [dB礦/m]
     80


     70


     60


     50


     40
                                                                         x
              x                x          x
     30                                                                            x     x       x                 x
                                                                                                        x

     20                                                        x


     10


          0
              30M             50M             70M       100M                   200M    300M      500M       700M   1G
                                                            Frequency [Hz]

    x             MES 0111-V2_red
                  MES 0111-V2_pre
                  LIM FCC 15 F 3 QP       Field Strength QP




 TTRF15.247-02_V1 © 2018 Intertek                                     Page 22 of 31


                                                                           Report No.: 190100007SHA-005



TEST REPORT


Test data below 1GHz
                                    Corrected
                     Frequency                   Correct Factor     Limit        Margin
   Antenna                           Reading                                                 Detector
                       (MHz)                        (dB/m)        (dBuV/m)        (dB)
                                    (dBuV/m)
       H                30.00        23.10             18.60       40.00          16.90         PK

       H                57.21        18.80              7.30       40.00          21.20         PK

       H                74.71        19.70              7.50       40.00          20.30         PK

       H               146.63        39.90             11.90       43.50           3.60         PK

       H               197.17        26.50             10.90       43.50          17.00         PK

       H               296.31        34.10             14.70       46.00          11.90         PK

       H               451.82        32.80             18.60       46.00          13.20         PK

       H               601.50        28.10             20.80       46.00          17.90         PK

       H               900.86        38.50             23.50       46.00           7.50         PK

       V                30.00        34.40             18.60       40.00           5.60         PK

       V                47.49        33.60              9.70       40.00           6.40         PK

       V                61.10        33.30              6.90       40.00           6.70         PK

       V               111.64        20.40             12.70       43.50          23.10         PK

       V               148.58        36.30             11.80       43.50           7.20         PK

       V               197.17        29.70             10.90       43.50          13.80         PK

       V               300.20        29.40             14.70       46.00          16.60         PK

       V               451.82        30.90             18.60       46.00          15.10         PK

       V               595.67        27.10             20.70       46.00          18.90         PK

       V               900.86        30.90             23.50       46.00          15.10         PK




 TTRF15.247-02_V1 © 2018 Intertek               Page 23 of 31


                                                                          Report No.: 190100007SHA-005



TEST REPORT


Test result above 1GHz:
The emission was conducted from 1GHz to 25GHz

                                         Correct         Corrected
                             Frequency                                  Limit      Margin
   CH        Antenna                      Factor          Reading                            Detector
                               (MHz)                                  (dBuV/m)      (dB)
                                         (dB/m)          (dBuV/m)
                 H            2402.00     30.70            95.90     Fundamental      /         PK
                 V            2402.00    30.70              94.80    Fundamental      /         PK
                 H            2390.00    30.30              47.80       74.00       26.20       PK
                 H            2390.00    30.30              43.50       54.00       10.50       AV
                 H            4804.00     -1.50             45.20       74.00       28.80       PK
    L
                 H            7206.00     3.50              44.10       74.00       29.90       PK
                 V            2390.00    30.30              46.30       74.00       27.70       PK
                 V            2390.00    30.30              40.50       54.00       13.50       AV
                 V            4804.00     -1.50             43.70       74.00       30.30       PK
                 V            7206.00     3.50              44.60       74.00       29.40       PK
                 H            2440.00    30.70              96.30    Fundamental      /         PK
                 V            2440.00    30.70              94.60    Fundamental      /         PK
                 H            4880.00     -1.10             44.60       74.00       29.40       PK
   M
                 H            7320.00     3.60              45.20       74.00       28.80       PK
                 V            4880.00     -1.10             43.70       74.00       30.30       PK
                 V            7320.00     3.60              45.50       74.00       28.50       PK
                 H            2480.00    30.70              96.10    Fundamental      /         PK
                 V            2480.00    30.70              95.30    Fundamental      /         PK
                 H            2483.50    30.80              48.60       74.00       25.40       PK
                 H            2483.50    30.80              44.90       54.00       9.10        AV
                 V            2483.50    30.80              45.20       74.00       28.80       PK
    H
                 V            2483.50    30.80              42.60       54.00       11.40       AV
                 H            4960.00     -0.80             44.50       74.00       29.50       PK
                 H            7440.00     3.80              48.20       74.00       25.80       PK
                 V            4960.00     -0.80             43.50       74.00       30.50       PK
                 V            7440.00     3.80              46.50       74.00       27.50       PK

Remark: 1. Correct Factor = Antenna Factor + Cable Loss (+ Amplifier, for higher than 1GHz), the
          value was added to Original Receiver Reading by the software automatically.
       2. Corrected Reading = Original Receiver Reading + Correct Factor
       3. Margin = Limit - Corrected Reading
       4. If the PK Corrected Reading is lower than AV limit, the AV test can be elided.

 TTRF15.247-02_V1 © 2018 Intertek                  Page 24 of 31


                                                                  Report No.: 190100007SHA-005



TEST REPORT


Example: Assuming Antenna Factor = 30.20dB/m, Cable Loss = 2.00dB,
        Gain of Preamplifier = 32.00dB, Original Receiver Reading = 10.00dBuV,
        Limit = 40.00dBuV/m.
        Then Correct Factor = 30.20 + 2.00 – 32.00 = 0.20dB/m;
        Corrected Reading = 10dBuV + 0.20dB/m = 10.20dBuV/m;
        Margin = 40.00dBuV/m - 10.20dBuV/m = 29.80dB.




 TTRF15.247-02_V1 © 2018 Intertek         Page 25 of 31


                                                                          Report No.: 190100007SHA-005



TEST REPORT


8 Power line conducted emission
     Test result:            Pass

8.1 Limit

                                                               Conducted Limit (dBuV)
    Frequency of Emission (MHz)
                                                      QP                                 AV

                   0.15-0.5                        66 to 56*                          56 to 46 *
                     0.5-5                                56                             46
                     5-30                                 60                             50
* Decreases with the logarithm of the frequency.



8.2 Test Configuration




                                         EUT
                          Peripheral
                           devices




                              LISN       LISN                          EMI receiver




TTRF15.247-02_V1 © 2018 Intertek          Page 26 of 31


                                                                          Report No.: 190100007SHA-005



TEST REPORT


8.3 Measurement Procedure
Measured levels of ac power-line conducted emission shall be the emission voltages from the voltage
probe, where permitted, or across the 50 Ω LISN port (to which the EUT is connected), where permitted,
terminated into a 50 Ω measuring instrument. All emission voltage and current measurements shall be
made on each current-carrying conductor at the plug end of the EUT power cord by the use of mating
plugs and receptacles on the LISN, if used. Equipment shall be tested with power cords that are normally
supplied or recommended by the manufacturer and that have electrical and shielding characteristics
that are the same as those cords normally supplied or recommended by the manufacturer. For those
measurements using a LISN, the 50 Ω measuring port is terminated by a measuring instrument having
50 Ω input impedance. All other ports are terminated in 50 Ω loads.

Tabletop devices shall be placed on a platform of nominal size 1 m by 1.5 m, raised 80 cm above the
reference ground plane. The vertical conducting plane or wall of an RF-shielded (screened) room shall
be located 40 cm to the rear of the EUT. Floor-standing devices shall be placed either directly on the
reference ground-plane or on insulating material as described in ANSI C63.4. All other surfaces of
tabletop or floor-standing EUTs shall be at least 80 cm from any other grounded conducting surface,
including the case or cases of one or more LISNs.

The bandwidth of the test receiver is set at 9 kHz.




 TTRF15.247-02_V1 © 2018 Intertek               Page 27 of 31


                                                                          Report No.: 190100007SHA-005



TEST REPORT


8.4 Test Results of Power line conducted emission

Test Curve:
                                                   L Line




Test Data:
                                    Quasi‐peak                                Average
    Frequency
      (MHz)                level       Limit         Margin       level         limit       Margin
                          dB(V)      dB(V)          (dB)       dB(V)        dB(V)        (dB)
       0.315               47.17       59.83         12.66        39.73         49.83       10.10
       1.131               44.61      56.00           11.39      29.65         46.00         16.35
       2.009               46.54      56.00            9.46      32.29         46.00         13.71
       2.765               44.62      56.00           11.38      32.90         46.00         13.10
       5.052               40.26      60.00           19.74      32.10         50.00         17.90
      14.964               32.26      60.00           27.74      22.22         50.00         27.78




 TTRF15.247-02_V1 © 2018 Intertek                Page 28 of 31


                                                                          Report No.: 190100007SHA-005



TEST REPORT


Test Curve:
                                                   N Line




Test Data:
                                    Quasi‐peak                                Average
    Frequency
      (MHz)                level       Limit         Margin       level         limit        Margin
                          dB(V)      dB(V)          (dB)       dB(V)        dB(V)         (dB)
       0.475               45.74       56.42          10.68       39.50         46.42          6.92
       0.789               47.03      56.00            8.97      37.22          46.00          8.78
       1.061               47.15      56.00            8.85      38.45          46.00          7.55
       1.747               45.91      56.00           10.09      37.68          46.00          8.32
       2.901               46.43      56.00            9.57      41.61          46.00          4.39
    23.968             24.57         60.00          35.43          18.89          50.00        31.11
Remark: 1. Correct Factor = LISN Factor + Cable Loss, the value was added to Original Receiver Reading
           by the software automatically.
        2. Corrected Reading = Original Receiver Reading + Correct Factor
        3. Margin = Limit ‐ Corrected Reading
        4. If the PK Corrected Reading is lower than AV limit, the AV test can be elided.




 TTRF15.247-02_V1 © 2018 Intertek                Page 29 of 31


                                                                           Report No.: 190100007SHA-005



TEST REPORT


9 Occupied Bandwidth
      Test result:           Tested

9.1 Limit

None


9.2 Measurement Procedure

The occupied bandwidth per RSS-Gen Issue 5 Clause 6.6 was measured using the Spectrum Analyzer.

The span of the analyzer shall be set to capture all products of the modulation process, including the
emission skirts.

The resolution bandwidth (RBW) shall be in the range of 1% to 5% of the occupied bandwidth (OBW)
and video bandwidth (VBW) shall be approximately 3x RBW.



9.3 Test Configuration



                                    EUT                         Spectrum Analyzer




9.4 The results of Occupied Bandwidth

        Please refer to Appendix A




 TTRF15.247-02_V1 © 2018 Intertek               Page 30 of 31


                                                                           Report No.: 190100007SHA-005



TEST REPORT


10 Antenna requirement
Requirement:
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply
with the provisions of this section.

Result:
EUT uses used a no-standard electrical connector antenna to the intentional radiator, so it can comply
with the provisions of this section.




  **************************************** END ****************************************




 TTRF15.247-02_V1 © 2018 Intertek              Page 31 of 31



Document Created: 2019-02-22 15:28:47
Document Modified: 2019-02-22 15:28:47

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC