MPE

FCC ID: ZKJ-BLEB001

RF Exposure Info

Download: PDF
FCCID_3498365

                                                                                                         REPORT No.:SZ17050201S01




                                        RF EXPOSURE
                           EVALUATION REPORT


             APPLICANT                         :         Haier US Appliance Solutions, Inc.

             PRODUCT NAME                      :         BB2707-25 Bluetooth Dual Mode Module

             MODEL NAME                        :         BLEB001


             TRADE NAME                        :


             BRAND NAME                        :         Haier

             FCC ID                            :         ZKJ-BLEB001

                                                         47CFR 2.1093
             STANDARD(S)                       :         KDB 447498                      D01         General        RF        Exposure
                                                         Guidance v06

             ISSUE DATE                        :         2017-07-14




             SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.

NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the
company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for
validation and information confirmed at our website.



MORLAB GROUP
                                         FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
                                         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn


                                                                                                           REPORT No.:SZ17050201S01



                                                                DIRECTORY

 TEST REPORT DECLARATION ······················································································································ 3


 1. TECHNICAL INFORMATION ···················································································································· 4


 1.1. IDENTIFICATION OF APPLICANT··················································································································· 4
 1.2. IDENTIFICATION OF MANUFACTURER ··········································································································· 4
 1.3. EQUIPMENT UNDER TEST (EUT) ················································································································ 4
 1.3.1. PHOTOGRAPHS OF THE EUT·······························································································································5
 1.3.2. IDENTIFICATION OF ALL USED EUT·······················································································································6
 1.4. APPLIED REFERENCE DOCUMENTS ·············································································································· 6


 2.DEVICE CATEGORY AND RF EXPOSURE LIMIT··························································································· 7


 3.MEASUREMENT OF CONDUCTED PEAK OUTPUT POWER ········································································· 8


 4. RF EXPOSURE EVALUATION···················································································································· 8


 ANNEX A GENERAL INFORMATION ············································································································ 9



                                                                   Change History
  Issue                Date                                                           Reason for change
    1.0           2017-07-14                                                                First edition




MORLAB GROUP
                                           FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
                                           Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                                  Page 2 0f 9


                                                                                          REPORT No.:SZ17050201S01



                        TEST REPORT DECLARATION

 Applicant               Haier US Appliance Solutions, Inc.
                         Appliance Park AP5-2N-67, Louisville, KY, United States (Zip
 Applicant Address
                         Code : 40225)
 Manufacturer            iTON Technology Corp.
                         7 Floor East,Building C, No. 1006 Shennan Road, Shenzhen
 Manufacturer Address
                         International Innovation Certer, Shenzhen, China.
 Product Name            BB2707-25 Bluetooth Dual Mode Module

 Model Name              BLEB001

 Brand Name              Haier

 HW Version              Ver 1.3

 SW Version              Ver 2.0
                         47CFR 2.1093;
 Test Standards
                         KDB 447498 D01 General RF Exposure Guidance v06

 Issue Date              2017-06-03

 SAR Evaluation          Not Required




                  Tested by           :
                                                        Peng Fuwei (Test engineer)


                  Approved by         :
                                                          Peng Huarui (Supervisor)




MORLAB GROUP
                          FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
                          Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                 Page 3 0f 9


                                                                                            REPORT No.:SZ17050201S01



 1. TECHNICAL INFORMATION
 Note: the following data is based on the information by the applicant.

 1.1. Identification of Applicant
 Company Name:               Haier US Appliance Solutions, Inc.
 Address:                    Appliance Park AP5-2N-67, Louisville, KY, United States (Zip
                             Code : 40225)
 1.2. Identification of Manufacturer
 Company Name:               iTON Technology Corp.
 Address:                    7 Floor East,Building C, No. 1006 Shennan Road, Shenzhen
                             International Innovation Certer, Shenzhen, China.
 1.3. Equipment Under Test (EUT)
 Model Name:                 BLEB001
 Trade Name:



 Brand Name:                 Haier
 Hardware Version:           Ver 1.3
 Software Version:           Ver 2.0
 Frequency Bands:            Bluetooth 4.2:2402-2480MHz;
 Modulation Mode:            Bluetooth 4.2: GFSK, π/4-DQPSK, 8-DPSK
 Antenna Type:               PCB Antenna
 Antenna Gain:               -2.65 dBi




MORLAB GROUP
                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
                            Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                   Page 4 0f 9


                                                                                         REPORT No.:SZ17050201S01



 1.3.1. Photographs of the EUT


 1.   EUT front view




 2.   EUT rear view




MORLAB GROUP
                         FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
                         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                Page 5 0f 9


                                                                                            REPORT No.:SZ17050201S01



 1.3.2. Identification of all used EUT

 The EUT identity consists of numerical and letter characters, the letter character indicates the test
 sample, and the following two numerical characters indicate the software version of the test
 sample.


               EUT
                            Hardware Version                                         Software Version
             Identity
                   1#                Ver 1.3                                                Ver 2.0


 1.4. Applied Reference Documents
 Leading reference documents for testing:
 No.    Identity                           Document Title
 1      47 CFR§2.1093                      Radiofrequency Radiation Exposure Evaluation: portable
                                           devices
 2      KDB 447498 D01v06                  General RF Exposure Guidance




MORLAB GROUP
                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
                            Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                   Page 6 0f 9


                                                                                             REPORT No.:SZ17050201S01



 2. DEVICE CATEGORY AND RF EXPOSURE LIMIT

 Per user manual, this device is a Bluetooth Dual Mode Module. Based on 47CFR 2.1093, this
 device belongs to portable device category with General Population/Uncontrolled exposure.
 Portable Devices:
 47CFR 2.1093(b)
 For purposes of this section, a portable device is defined as a transmitting device designed to be
 used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the
 user.

 GENERAL POPULATION / UNCONTROLLED EXPOSURE
 47CFR 2.1093(d) (2)
 Limits for General Population/Uncontrolled exposure: 0.08 W/kg as averaged over the whole-body
 and spatial peak SAR not exceeding 1.6 W/kg as averaged over any 1 gram of tissue (defined as a
 tissue volume in the shape of a cube). Exceptions are the hands, wrists, feet and ankles where the
 spatial peak SAR shall not exceed 4 W/kg, as averaged over any 10 grams of tissue (defined as a
 tissue volume in the shape of a cube). General Population/Uncontrolled limits apply when the
 general public may be exposed, or when persons that are exposed as a consequence of their
 employment may not be fully aware of the potential for exposure or do not exercise control over
 their exposure. Warning labels placed on consumer devices such as cellular telephones will not be
 sufficient reason to allow these devices to be evaluated subject to limits for occupational/controlled
 exposure in paragraph (d)(1) of this section.




MORLAB GROUP
                             FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
                             Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                    Page 7 0f 9


                                                                                              REPORT No.:SZ17050201S01



 3. MEASUREMENT OF CONDUCTED PEAK OUTPUT POWER
 1. Bluetooth Peak output power


                                                                        Output Power(dBm)
                 Band         Channel
                                                      GFSK                 π/4-DQPSK                    8-DPSK
                                    0                  6.78                       6.05                     6.56
                  BT
                                   39                  6.73                       6.48                     6.75
               4.2+EDR
                                   78                  6.92                       7.03                     6.46



                                                                                            Output
                                                             Frequency                    Power(dBm)
                        Band             Channel
                                                               (MHz)
                                                                                              GFSK
                                               0                  2402                        5.71
                         BT                   19                  2440                        5.81
                                              39                  2480                        6.03



 4. RF EXPOSURE EVALUATION
 The device only incorporates a Bluetooth transmitter, so standalone SAR evaluation is required for
 Bluetooth and simultaneous SAR is not required.

 Standalone transmission SAR evaluation

 According to KDB 447498 section 4.3.1, the 1-g SAR test exclusion thresholds at test separation
 Distances ≤ 50 mm are determined by:
 [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
 mm)]·[√f(GHz)] ≤ 3.0
 The maximum tune-up limit power is 5.62mW @ 2.480GHz
 When Bluetooth Dual Mode Module is close to the body, so use 5mm as the most conservative
 minimum test separation distance,
 [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
 mm)]·[√f(GHz)] =1.55 ≤ 3.0

 So SAR evaluation is not required for this device.



MORLAB GROUP
                              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
                              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                     Page 8 0f 9


                                                                                          REPORT No.:SZ17050201S01




 ANNEX A GENERAL INFORMATION

 1. Identification of the Responsible Testing Laboratory
  Company Name:                             Shenzhen Morlab Communications Technology Co., Ltd.
  Department:                               Morlab Laboratory
  Address:                                  FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                            Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                            Province, P. R. China
  Responsible Test Lab Manager:             Mr. Su Feng
  Telephone:                                +86 755 36698555
  Facsimile:                                +86 755 36698525


 2. Identification of the Responsible Testing Location
  Name:                                     Shenzhen Morlab Communications Technology Co., Ltd.
                                            Morlab Laboratory
  Address:                                  FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                            Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                            Province, P. R. China



                                    ***** END OF REPORT *****




MORLAB GROUP
                          FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555    Fax: 86-755-36698525
                          Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.com   E-mail: service@morlab.cn

                                                                                                                                 Page 9 0f 9



Document Created: 2017-07-24 16:06:09
Document Modified: 2017-07-24 16:06:09

© 2024 FCC.report