Test Report

FCC ID: ZFT-K105

Test Report

Download: PDF
FCCID_1453237

              Report No.: KS110407B01-EF              FCC ID: ZFT-K105          Date of Issue: April 14, 2011



                    FCC 47 CFR PART 15 SUBPART B
                            TEST REPORT
                                                      for

                                             Mobile Phone
                                         MODEL: K105,P32D
                                       Trade Name: B-mobile
                                        Test Report Number:
                                          KS110407B01-EF

                                                  Issued to:

                       Global Mobile Communication (HK) Ltd.,
                    7/F,Kin On Commercial Building,49-51 Jervois
                         Street,Sheung Wan,HongKong,China

                                                  Issued by:

                               Compliance Certification Services Inc.
                                       Linkuo Laboratory
                            No. 81-1, Lane 210, Pa-De 2nd Rd., Luchu
                                             Hsiang,
                              Taoyuan Shien, (338), Taiwan, R.O.C.
                                       TEL: 886-3-324-0332
                                          FAX: 886-3-324-5235
                                      Issued Date: April 14, 2011




Note: This report shall not be reproduced except in full, without the written approval of Compliance
Certification Services Inc. This document may be altered or revised by Compliance Certification Services Inc.
personnel only, and shall be noted in the revision section of the document. The client should not use it to claim
product endorsement by , A2LA, NIST or any government agencies. The test results in the report only apply
to the tested sample.


                                                  Page 1 / 28


             Report No.: KS110407B01-EF                    FCC ID: ZFT-K105             Date of Issue: April 14, 2011



                                                Revision History


                                                                                 Effect Page
Rev.          Issue Date                         Revisions                                              Revised By

00           April 14, 2011                      Initial Issue                       ALL                Hadiif.Hoo




                                                        Page 2
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                Report No.: KS110407B01-EF                                 FCC ID: ZFT-K105                    Date of Issue: April 14, 2011


                                                   TABLE OF CONTENTS

1       TEST RESULT CERTIFICATION................................................................................... 4
2       EUT DESCRIPTION........................................................................................................... 5
3       TEST METHODOLOGY ................................................................................................... 6
 3.1.   DECISION OF FINAL TEST MODE ....................................................................................................6
4       SETUP OF EQUIPMENT UNDER TEST ........................................................................ 7
 4.1.   DESCRIPTION OF SUPPORT UNITS................................................................................................7
 4.2.   CONFIGURATION OF SYSTEM UNDER TEST ................................................................................8
5       FACILITIES AND ACCREDITATIONS ......................................................................... 9
 5.1.   FACILITIES..........................................................................................................................................9
 5.2.   ACCREDITATIONS .............................................................................................................................9
 5.3.   MEASUREMENT UNCERTAINTY ......................................................................................................9
 5.4.   LIST OF TEST EQUIPMENT ............................................................................................................10
6       CONDUCTED EMISSION MEASUREMENT.............................................................. 12
 6.1.   LIMITS OF CONDUCTED EMISSION MEASUREMENT .................................................................12
 6.2.   TEST INSTRUMENTS ......................................................................................................................12
 6.3.   TEST PROCEDURES .......................................................................................................................13
 6.4.   TEST SETUP.....................................................................................................................................14
 6.5.   DATA SAMPLE..................................................................................................................................14
 6.6.   TEST RESULTS ................................................................................................................................15
7       RADIATED EMISSION MEASUREMENT .................................................................. 17
 7.1.   LIMITS OF RADIATED EMISSION MEASUREMENT ......................................................................17
 7.2.   TEST INSTRUMENTS ......................................................................................................................19
 7.3.   TEST PROCEDURES .......................................................................................................................19
 7.4.   TEST SETUP.....................................................................................................................................21
 7.5.   DATA SAMPLE..................................................................................................................................22
 7.6.   TEST RESULTS ................................................................................................................................23
PHOTOGRAPHS OF THE TEST CONFIGURATION ........................................................... 27
APPENDIX 1 - PHOTOGRAPHS OF EUT ...................................................................A1-1




                                                                       Page 3
    This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                Report No.: KS110407B01-EF                  FCC ID: ZFT-K105             Date of Issue: April 14, 2011


1 TEST RESULT CERTIFICATION
  Product Name:          Mobile Phone

         Model No.:      K105, P32D
    Brand Name:          B-mobile
          Applicant:     Global Mobile Communication (HK) Ltd.,
          Address :      7/F,Kin On Commercial Building,49-51 Jervois Street,Sheung
                         Wan,HongKong,China
   Manufacturer:         Water World Technology Co., Ltd
          Address :      6 Floor, Block B, Digital Building, Garden City,No.1079.Nanhai Road,
                         NanshanDistrict, Shenzhen, Guangdong, China
        Tested Date:     April 12,2011-April 14,2011

                                                      EMISSION
             Standard                               Item                  Result                  Remarks

FCC 47 CFR Part 15 Subpart B,          Conducted (Power Port)              PASS               Meet Class B limit
ICES-003 Issue 4
ANSI C63.4-2009                        Radiated                            PASS               Meet Class B limit


Note:     1. The statements of test result on the above are decided by the request of test standard only; the
             measurement uncertainties are not factored into this compliance determination.
          2. The information of measurement uncertainty is available upon the customer’s request.


                                     Deviation from Applicable Standard

                                                          None


The above equipment has been tested by Compliance Certification Services Inc., and found
compliance with the requirements set forth in the technical standards mentioned above. The
results of testing in this report apply only to the product/system, which was tested. Other
similar equipment will not necessarily produce the same results due to production tolerance
and measurement uncertainties.


Approved by:                                                     Reviewed by:




Hadiif.Hoo                                                       Dohnny.Lu
EMC Manager                                                      EMC Section Manager
Compliance Certification Service Inc.                            Compliance Certification Service Inc.


                                                         Page 4
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


              Report No.: KS110407B01-EF                    FCC ID: ZFT-K105             Date of Issue: April 14, 2011


2 EUT DESCRIPTION

Product Name                     Mobile Phone

Brand Name                       B-mobile

Model Number                     K105,P32D

FCC ID                           FCC ID: ZFT-K105

Applicant                        Global Mobile Communication (HK) Ltd.,

Housing material                 plastic casing

EUT Type                            Engineering Sample.             Product Sample.          Mass Product Sample.

                                 Powered from an AC/DC power adapter
                                 Model Number :UTC-24
                                 Input:100-240V 200mA 50-60Hz
                                 Output:5.0V 500mA
EUT Power Rating
                                 Battery
                                 Model: BL-5B
                                 Standard Voltage:3.7V
                                 Rating Capacity:600mAh
AC Power Cord Type               N/A
I/O Cable Type                   Shielded,1m


I/O PORT

         I/O PORT TYPES                                     Q’TY                              TESTED WITH
1. Micro B Port                                               1                                        1




                                                         Page 5
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


             Report No.: KS110407B01-EF                    FCC ID: ZFT-K105             Date of Issue: April 14, 2011


3 TEST METHODOLOGY
3.1. DECISION OF FINAL TEST MODE
    The EUT was tested together with the above additional components, and a
    configuration, which produced the worst emission levels, was selected and recorded
    in this report.
    The test configuration modes are as the following:
    Conduction Modes:
      1     Micro B Port Data rate
      2     Micro B Port Adapter

    Radiation Modes:
      1     Micro B Port Data rate
      2     Micro B Port Adapter

    After the preliminary scan, the following test mode was found to produce the final emission
    level.
   Conduction: Mode 2
   Radiation: Mode 2




                                                        Page 6
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                 Report No.: KS110407B01-EF                    FCC ID: ZFT-K105             Date of Issue: April 14, 2011


4 SETUP OF EQUIPMENT UNDER TEST
4.1. DESCRIPTION OF SUPPORT UNITS
The EUT has been tested as an independent unit together with other necessary accessories or
support units. The following support units or accessories were used to form a representative test
configuration during the tests.

                                                                                 Trade            Data
 No. Equipment Model No.                    Serial No.          FCC ID                                         Power Cord
                                                                                 Name             Cable
                                                                                                Shielded,
                                                                                                  1.8m         Un-Shielded,
  1           PC           6010GC           CNG44001T2            DoC               HP
                                                                                                with two          1.8m
                                                                                                  Core
Note:
1) All the equipment/cables were placed in the worst-case configuration to maximize the emission during the test.
2) Grounding was established in accordance with the manufacturer’s requirements and conditions for the intended use.




                                                            Page 7
      This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


             Report No.: KS110407B01-EF                    FCC ID: ZFT-K105             Date of Issue: April 14, 2011


4.2. CONFIGURATION OF SYSTEM UNDER TEST




Receiver                                                                                  120VAC


                                                   **EUT
                                              (Included Support
                                                     units)


                                                 Test Table




                                                        Page 8
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


              Report No.: KS110407B01-EF                    FCC ID: ZFT-K105             Date of Issue: April 14, 2011


5 FACILITIES AND ACCREDITATIONS
5.1. FACILITIES
All measurement facilities used to collect the measurement data are located at
No. 81-1, Lane 210, Pa-De 2nd Rd., Luchu Hsiang, Taoyuan Shien, Taiwan.

The sites are constructed in conformance with the requirements of ANSI C63.4 and CISPR 22. All
receiving equipment conforms to CISPR 16-1-1, CISPR 16-1-2, CISPR 16-1-3, CISPR 16-1-4,
CISPR 16-1-5.


5.2. ACCREDITATIONS
Our laboratories are accredited and approved by the following accreditation body according to
ISO/IEC 17025.
                 USA                        A2LA
The measuring facility of laboratories has been authorized or registered by the following approval
agencies.
                 Canada                     Industry Canada
                 Japan                      VCCI
                 Taiwan                     BSMI
                 USA                        FCC
Copies of granted accreditation certificates are available for downloading from our web site,
http:///www.ccsrf.com


5.3. MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated for
tests performed on the EUT as specified in CISPR 16-4-2:
               Measurement                               Frequency                           Uncertainty
            Conducted emissions                       0.15MHz~30MHz                             ± 3.43 dB


           Measurement                    Polarity                   Frequency                   Uncertainty
                                                                  30MHz ~ 200MHz                   +/- 4.72dB
                                              H
        Radiated emissions                                       200MHz ~1000MHz                   +/- 4.72dB
            (below 1GHz)                                          30MHz ~ 200MHz                   +/- 4.83dB
                                              V
                                                                 200MHz ~1000MHz                   +/- 4.70dB
                                                                1000MHz ~5000MHz                   +/- 3.92dB
                                              H
        Radiated emissions                                      5000MHz ~8000MHz                   +/- 3.94dB
            (above 1GHz)                                        1000MHz ~5000MHz                   +/- 3.92dB
                                              V
                                                                5000MHz ~8000MHz                   +/- 3.93dB

This uncertainty represents an expanded uncertainty expressed at approximately the 95%
confidence level using a coverage factor of k=2.
Consistent with industry standard (e.g. CISPR 22: 2005, clause 11, Measurement Uncertainty)
determining compliance with the limits shall be base on the results of the compliance
measurement. Consequently the measure emissions being less than the maximum allowed

                                                         Page 9
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


               Report No.: KS110407B01-EF                    FCC ID: ZFT-K105             Date of Issue: April 14, 2011

emission result in this be a compliant test or passing test.
The acceptable measurement uncertainty value without requiring revision of the compliance
statement is base on conducted and radiated emissions being less than UCISPR which is 3.6dB
and 5.2dB respectively. CCS values (called ULab in CISPR 16-4-2) is less than UCISPR as shown
in the table above. Therefore, MU need not be considered for compliance.

5.4. LIST OF TEST EQUIPMENT
                                                 Conducted Emission

  Name of Equipment               Manufacturer                Model              Serial Number Calibration Due

   EMI TEST RECEIVER                    R&S                    ESCI3                  100781               04/29/2011

         V (V-LISN)                Schwarzbeck              NNLK 8129                8129-143              04/29/2011

                                                       FCC-LISN-50/250-5
         LISN (EUT)                     FCC                                          SN:05012              04/29/2011
                                                               0-2-02

   TRANSIENT LIMITER               SCHAFFNER                 CFL9206                    1710               04/29/2011

       Test Software                                                      EZ-EMC

NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
      2. N.C.R = No Calibration Request.


                 Radiated Emission (Test Site A (10m chamber) for 30MHz-1GHz)
  Name of Equipment               Manufacturer                Model              Serial Number Calibration Due

    EMI Test Receiver                   R&S                    ESI26                  100068               05/26/2011

       Bilog Antenna                   Sunol                    JB1                  A110204               06/24/2011

        Pre-Amplifier                  Anritsu               MH648A                   M64192               05/28/2011

     System Controller                 Sunol                  SC99V                  121501-1                N.C.R.

         Turn Table                    Sunol                FM3022HS                    N/A                  N.C.R.

       Antenna Mast                    Sunol                 TWR 99-4                121501-3                N.C.R.
       Test Software                                                      EZ-EMC

NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
      2. N.C.R = No Calibration Request.




                                                          Page 10
    This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


               Report No.: KS110407B01-EF                    FCC ID: ZFT-K105             Date of Issue: April 14, 2011




            Radiated Emission (3M Semi Anechoic Chamber (977) For 1 GHz -18GHz)

  Name of Equipment               Manufacturer               Model            Serial Number           Calibration Due
    Spectrum Analyzer                  Agilent               E4446A             MY44020154                05/26/2011
    EMI Test Receiver                   R&S                   ESPI3                 101026                04/29/2011
        Pre-Amplfier                    MINI             ZFL-1000VH2               d041703                06/30/2011
        Pre-Amplfier                    Miteq             NSP4000-NF                870629                06/30/2011
       Bilog Antenna                   Sunol                   JB1                A110204-2               06/24/2011
       Horn-antenna             SCHWARZBECK               BBHA9120D                  D:266                05/07/2011
        Turn Table                       CT                   CT123                  4165                    N.C.R
      Antenna Tower                      CT                CTERG23                   3256                    N.C.R
         Controller                      CT                  CT1OO                   95637                   N.C.R
       Test Software                                                      EZ-EMC
NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
      2.N.C.R = No Calibration Request.




                                                          Page 11
    This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


               Report No.: KS110407B01-EF                    FCC ID: ZFT-K105             Date of Issue: April 14, 2011


6 CONDUCTED EMISSION MEASUREMENT
6.1. LIMITS OF CONDUCTED EMISSION MEASUREMENT
                                         Class A (dBuV)                               Class B (dBuV)
 FREQUENCY (MHz)
                               Quasi-peak             Average              Quasi-peak                 Average
       0.15 - 0.5                   79                    66                  66 - 56                   56 - 46
       0.50 - 5.0                   73                    60                     56                       46
       5.0 - 30.0                   73                    60                     60                       50
NOTE:
(1) The lower limit shall apply at the transition frequencies.
(2) The limit decreases in line with the logarithm of the frequency in the range 0.15 to 0.50 MHz.
(3) All emanations from a class A/B digital device or system, including any network of conductors and
    apparatus connected thereto, shall not exceed the level of field strengths specified above.


6.2. TEST INSTRUMENTS
See list of test equipment of this test report.




                                                          Page 12
    This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


              Report No.: KS110407B01-EF                    FCC ID: ZFT-K105             Date of Issue: April 14, 2011




6.3. TEST PROCEDURES
Procedure of Preliminary Test
  z    The EUT and support equipment, if needed, were set up as per the test configuration
       to simulate typical usage per the user’s manual. When the EUT is a tabletop system,
       a wooden table with a height of 0.8 meters is used and is placed on the ground plane
       as per ANSI C63.4 (see Test Facility for the dimensions of the ground plane used).
       When the EUT is a floor standing equipment, it is placed on the ground plane, which
       has a 12 mm non-conductive covering to insulate the EUT from the ground plane.
  z    All I/O cables were positioned to simulate typical actual usage as per ANSI C63.4.
  z    The test equipment EUT installed by AC 120VAC/60Hz main power, through a Line
       Impedance Stabilization Network (LISN), which was supplied power source and was
       grounded to the ground plane.
  z    All support equipment power by from a second LISN.
  z    The test program of the EUT was started. Emissions were measured on each
       current carrying line of the EUT using an EMI Test Receiver connected to the LISN
       powering the EUT.
  z    The Receiver scanned from 150kHz to 30MHz for emissions in each of the test
       modes.
  z    During the above scans, the emissions were maximized by cable manipulation.
  z    The test mode(s) described in Item 3.1 were scanned during the preliminary test.
  z    After the preliminary scan, we found the test mode described in Item 3.1 producing
       the highest emission level.
  z    The worst configuration of EUT and cable of the above highest emission level were
       recorded for reference of the final test.
Procedure of Final Test
  z    EUT and support equipment were set up on the test bench as per the configuration
       with highest emission level in the preliminary test.
  z    A scan was taken on both power lines, Line 1 and Line 2, recording at least the six
       highest emissions. Emission frequency and amplitude were recorded into a
       computer in which correction factors were used to calculate the emission level and
       compare reading to the applicable limit.
  z    The test data of the worst-case condition(s) was recorded.




                                                         Page 13
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


              Report No.: KS110407B01-EF                    FCC ID: ZFT-K105             Date of Issue: April 14, 2011


6.4. TEST SETUP

                                                   Vert. reference plane

                                                                                                 EMI receiver




                       40cm
                                      EUT




                                                            80cm




              LISN
                                                                   Reference ground plane




   z   For the actual test configuration, please refer to the related item – Photographs of
       the Test Configuration.


6.5. DATA SAMPLE
 Frequency   QuasiPeak     Average Correction      QuasiPeak       Average   QuasiPeak      Average     QuasiPeak     Average
              Reading      Reading  Factor          Result          Result     Limit         Limit       Margin        Margin
              (dBuV)       (dBuV)    (dB)           (dBuV)         (dBuV)     (dBuV)        (dBuV)        (dB)          (dB)


   x.xx        35.81          34.89     10.16         45.97        45.05        59.93        49.93        -13.96        -4.88


Correction factor (dB)         = cable loss + Insertion loss of LISN+ Insertion loss of transient limiter
                      (The transient limiter included 10 dB attenuation)
(QuasiPeak/ Average)Result = (QuasiPeak/ Average)reading + Correction Factor (dB)

Calculation Formula
(QuasiPeak/ Average)Margin (dB) = (QuasiPeak/ Average)Result (dBuV) –(QuasiPeak/
                             Average)Limit (dBuV)




                                                         Page 14
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                    Report No.: KS110407B01-EF                     FCC ID: ZFT-K105            Date of Issue: April 14, 2011


 6.6. TEST RESULTS
                                                                   L1




                    QuasiPeak   Average    Correction   QuasiPeak    Average     QuasiPeak   Average   QuasiPeak   Average
No.     Frequency                                                                                                            Remark
                     reading     reading     factor       result        result     limit      limit     margin     margin

         (MHz)       (dBuV)      (dBuV)       (dB)       (dBuV)      (dBuV)       (dBuV)     (dBuV)      (dB)       (dB)

1        0.1546       36.99       25.65      10.05        47.04         35.70      65.75      55.75     -18.71     -20.05        Pass

2*       0.5398       30.62       22.25      10.84        41.46         33.09      56.00      46.00     -14.54     -12.91        Pass

3        0.6170       30.71       22.15      10.89        41.60         33.04      56.00      46.00     -14.40     -12.96        Pass

4        1.1596       30.03       20.46      11.03        41.06         31.49      56.00      46.00     -14.94     -14.51        Pass

5        1.6212       30.70       19.85      11.06        41.76         30.91      56.00      46.00     -14.24     -15.09        Pass

6        2.1604       29.04       17.16      11.10        40.14         28.26      56.00      46.00     -15.86     -17.74        Pass




      Note: 1. L1 = Line One (Live Line) / L2 = Line Two (Neutral Line).




                                                              Page 15
        This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                  Report No.: KS110407B01-EF                     FCC ID: ZFT-K105           Date of Issue: April 14, 2011




                                                             L2




                  QuasiPeak   Average    Correction   QuasiPeak    Average   QuasiPeak   Average   QuasiPeak    Average
No.   Frequency                                                                                                           Remark
                   reading     reading     factor       result      result     limit       limit     margin     margin

       (MHz)       (dBuV)      (dBuV)       (dB)       (dBuV)      (dBuV)     (dBuV)     (dBuV)       (dB)        (dB)

1*     0.1544       37.30       24.66      10.15        47.45       34.81      65.76      55.76      -18.31      -20.95        Pass

2      0.2329       33.84       20.88      10.17        44.01       31.05      62.35      52.35      -18.34      -21.30        Pass

3      0.5478       26.47       15.81      10.14        36.61       25.95      56.00      46.00      -19.39      -20.05        Pass

4      1.1722       26.07       13.06      10.27        36.34       23.33      56.00      46.00      -19.66      -22.67        Pass

5      1.7193       25.88       11.62      10.47        36.35       22.09      56.00      46.00      -19.65      -23.91        Pass

6      2.1881       25.00       10.31      10.61        35.61       20.92      56.00      46.00      -20.39      -25.08        Pass



 Note:      1. L1 = Line One (Live Line) / L2 = Line Two (Neutral Line).




                                                            Page 16
      This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


               Report No.: KS110407B01-EF                    FCC ID: ZFT-K105             Date of Issue: April 14, 2011


7 RADIATED EMISSION MEASUREMENT
7.1. LIMITS OF RADIATED EMISSION MEASUREMENT
Below 1GHz (for digital device)
                                                                   dBuV/m (At 10m)
       FREQUENCY (MHz)
                                                       Class A                             Class B
              30 ~ 230                                   40                                  30
             230 ~ 1000                                  47                                  37

Limit tables for non-digital device:
Class A Radiated Emission limit at 10m (for others)
      Frequency                      Field Strength Limit                          Field Strength Limit
        (MHZ)                             (uV/m)Q.P.                                  (dBuV/m)Q.P.
        30 - 88                                90                                           39
       88 - 216                               150                                          43.5
      216 – 960                               210                                          46.4
      Above 960                               300                                          49.5

Class B Radiated Emission limit at 3m (for others)
      Frequency                      Field Strength Limit                          Field Strength Limit
        (MHZ)                             (uV/m)Q.P.                                  (dBuV/m)Q.P.
        30 - 88                               100                                           40
       88 - 216                               150                                          43.5
      216 – 960                               200                                           46
      Above 960                               500                                           54

Above 1GHz(for all device)
      Frequency                  Class A (dBuV/m) (At 10m)                     Class B (dBuV/m) (At 3m)
        (MHZ)                     Average          Peak                        Average          Peak
      Above 1000                    49.5           69.5                          54              74

NOTE: (1) The lower limit shall apply at the transition frequencies.
      (2) Emission level (dBuV/m) = 20 log Emission level (uV/m).
      (3) The measurement above 1GHz is at close-in distances 3m,and determine the limit L2
          corresponding to the close-in distance d2 by applying the following relation: L2 = L1 (d1/d2), where
          L1 is the specified limit in microvolts per metre (uV/m) at the distance d1 (10m), L2 is the new limit
          for distance d2 (3m).
          So the new Class A limit above 1GHz at 3m is as following table:




                                                          Page 17
    This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


               Report No.: KS110407B01-EF                    FCC ID: ZFT-K105             Date of Issue: April 14, 2011


                       Frequency                                          Class A (dBuV/m) (At 3m)
                         (MHZ)                                           Average                 Peak
                      Above 1000                                            60                     80
According to FCC Part 15.33 (b), for an unintentional radiator, including a digital device, the
spectrum shall be investigated from the lowest radio frequency signal generated or used in the
device, without going below the lowest frequency for which a radiated emission limit is specified, up
to the frequency shown in the following table:

 Highest frequency generated or used in the
                                                                  Upper frequency of measurement range
 device or on which the device operates or
                                                                                         (MHz)
                      tunes (MHz)
                       Below 1.75                                                           30
                        1.75-108                                                          1000
                         108-500                                                          2000
                        500-1000                                                          5000
                                                              5th harmonic of the highest frequency or 40GHz,
                      Above 1000
                                                                                  whichever is lower




                                                          Page 18
    This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


               Report No.: KS110407B01-EF                    FCC ID: ZFT-K105             Date of Issue: April 14, 2011


7.2. TEST INSTRUMENTS
See list of test equipment of this test report.

7.3. TEST PROCEDURES
Procedure of Preliminary Test
   z    The equipment was set up as per the test configuration to simulate typical usage per
        the user’s manual. When the EUT is a tabletop system, a wooden turntable with a
        height of 0.8 meters is used which is placed on the ground plane. When the EUT is a
        floor standing equipment, it is placed on the ground plane which has a 12 mm
        non-conductive covering to insulate the EUT from the ground plane.
   z    Support equipment, if needed, was placed as per ANSI C63.4.
   z    All I/O cables were positioned to simulate typical usage as per ANSI C63.4.
   z    The EUT received AC 120VAC/60Hz power source from the outlet socket under the
        turntable. All support equipment power received from another socket under the
        turntable.
   z    The antenna was placed at 3 or 10 meter away from the EUT as stated in ANSI
        C63.4. The antenna connected to the Spectrum Analyzer via a cable and at times a
        pre-amplifier would be used.
   z    The Analyzer / Receiver quickly scanned from 30MHz to 40GHz. The EUT test
        program was started. Emissions were scanned and measured rotating the EUT to
        360 degrees and positioning the antenna 1 to 4 meters above the ground plane, in
        both the vertical and the horizontal polarization, to maximize the emission reading
        level.
   z    Set the spectrum analyzer/ Receiver in the following setting as:
        Below 1GHz:
         RBW=100kHz / VBW=100kHz / Sweep=AUTO
       Above 1GHz:
         Peak: RBW=VBW=1MHz / Sweep=AUTO
         Average: RBW=1MHz / VBW=10Hz / Sweep=AUTO
   z    The test mode(s) described in Item 3.1 were scanned during the preliminary test:
   z    After the preliminary scan, we found the test mode described in Item 3.1 producing
        the highest emission level.
   z    The worst configuration of EUT and cable of the above highest emission level were
        recorded for reference of the final test.




                                                          Page 19
    This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


              Report No.: KS110407B01-EF                    FCC ID: ZFT-K105             Date of Issue: April 14, 2011


Procedure of Final Test
  z    EUT and support equipment were set up on the turntable as per the configuration
       with highest emission level in the preliminary test.
  z    The Analyzer / Receiver scanned from 30MHz to 40GHz. Emissions were scanned
       and measured rotating the EUT to 360 degrees, varying cable placement and
       positioning the antenna 1 or 1 to 4 meters above the ground plane, in both the
       vertical and the horizontal polarization, to maximize the emission reading level.
  z    Recording at least the six highest emissions. Emission frequency, amplitude,
       antenna position, polarization and turntable position were recorded into a computer
       in which correction factors were used to calculate the emission level and compare
       reading to the applicable limit. Below 1GHz the Q.P. reading and above 1GHz the
       Peak and Average reading are presented.
  z    The test data of the worst-case condition(s) was recorded.




                                                         Page 20
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


              Report No.: KS110407B01-EF                    FCC ID: ZFT-K105             Date of Issue: April 14, 2011


7.4. TEST SETUP
Below 1 GHz




. Above 1 GHz




  z    For the actual test configuration, please refer to the related item – Photographs of
       the Test Configuration.




                                                         Page 21
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


              Report No.: KS110407B01-EF                    FCC ID: ZFT-K105             Date of Issue: April 14, 2011


7.5. DATA SAMPLE
 Frequency Reading             Correct        Result          Limit          Margin        Height       Degree Remark
   (MHz)   (dBuV)              Factor       (dBuV/m)        (dBuV/m)          (dB)          (cm)         (°)
                               (dB/m)

    x.xx          37.04         -14.00         23.04           30.00          -6.96          300           40         peak

Freq.          = Emission frequency in MHz
Reading        = Uncorrected Analyzer/Receiver reading
Correct Factor = Antenna Factor + Cable Loss - Amplifier Gain
Result         = Reading + Factor
Limit          = Limit stated in standard
Margin         = Reading in reference to limit
Height         = Height of antenna
Degree         = Position of turn table
Remark         = Information of value (Peak/ QuasiPeak/Average)

Calculation Formula
Margin (dB) = Result (dBuV/m) – Limit (dBuV/m)




                                                         Page 22
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                 Report No.: KS110407B01-EF                    FCC ID: ZFT-K105              Date of Issue: April 14, 2011


7.6. TEST RESULTS
                                                         Below 1GHz
Model No.                    K105                                  Test Mode                  Mode 2
Environmental
                             26deg.C, 78% RH, 1010hPa              6dB Bandwidth              100 kHz
Conditions
Antenna Pole                 Vertical                              Antenna Distance           3m
Detector Function            Quasi-peak.                           Tested by                  Star
Standard                     FCC CLASS B




No.       Frequency      Reading        Correct          Result        Limit        Margin      Height      Degree     Remark

            (MHz)        (dBuV)      Factor(dB/m)      (dBuV/m)      (dBuV/m)        (dB)          (cm)     (deg.)

 1         30.0000        30.41           1.87           32.28         40.00         -7.72         100        42         peak
 2         45.5200        45.07           -8.78          36.29         40.00         -3.71         100       319         peak
 3         59.1000        46.53          -11.47          35.06         40.00         -4.94         100        10         peak
 4         88.2000        44.70          -11.30          33.40         43.50        -10.10         100       168         peak
 5        229.8200        38.07           -6.44          31.63         46.00        -14.37         100       290         peak
 6        960.2300        26.85           8.07           34.92         54.00        -19.08         100       286         peak




Note:        1. The other emission levels were very low against the limit.




                                                            Page 23
      This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                 Report No.: KS110407B01-EF                    FCC ID: ZFT-K105              Date of Issue: April 14, 2011



Model No.                    K105                                  Test Mode                  Mode 2
Environmental
                             26deg.C, 78% RH, 1010hPa              6dB Bandwidth              100 kHz
Conditions
Antenna Pole                 Horizontal                            Antenna Distance           3m
Detector Function            Quasi-peak.                           Tested by                  Star
Standard                     FCC CLASS B




No.       Frequency      Reading        Correct          Result        Limit        Margin      Height      Degree     Remark

            (MHz)        (dBuV)      Factor(dB/m)      (dBuV/m)      (dBuV/m)        (dB)          (cm)     (deg.)

 1         30.0000        28.20           1.87           30.07         40.00         -9.93         100       229         peak
 2         59.1000        41.13           -11.47         29.66         40.00        -10.34         100       114         peak
 3         88.2000        45.06           -11.30         33.76         43.50         -9.74         100         0         peak
 4        335.5500        36.22           -3.02          33.20         46.00        -12.80         100       111         peak
 5        358.8300        32.49           -2.36          30.13         46.00        -15.87         100       158         peak
 6        960.2300        27.50           8.07           35.57         54.00        -18.43         100       210         peak



                        Note:       1. The other emission levels were very low against the limit.




                                                            Page 24
      This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                 Report No.: KS110407B01-EF                    FCC ID: ZFT-K105              Date of Issue: April 14, 2011

                                                       Above 1GHz
Model No.                    K105                                  Test Mode                  Mode 2
Environmental
                             26deg.C, 78% RH, 1010hPa              6dB Bandwidth              1 MHz
Conditions
Antenna Pole                 Vertical                              Antenna Distance           3m
Detector Function            Peak or average.                      Tested by                  Star
Standard                     FCC CLASS B




No.       Frequency      Reading        Correct          Result        Limit        Margin      Height      Degree     Remark

            (MHz)        (dBuV)      Factor(dB/m)      (dBuV/m)      (dBuV/m)        (dB)          (cm)      (°)

 1        1434.870        50.40          -10.37          40.03         74.00        -33.97         100       126         peak
 2        1434.870        39.44          -10.37          29.07         54.00        -24.93         100       103         AVG
 3        2991.984        48.96           -5.88          43.08         74.00        -30.92         100       133         peak
 4        2991.984        32.86           -5.88          26.98         54.00        -27.02         100       152         AVG
 5        6667.335        48.84           0.07           48.91         74.00        -25.09         100       299         peak
 6        6667.335        30.98           0.07           31.05         54.00        -22.95         100       316         AVG



Note:        1. The other emission levels were very low against the limit.




                                                       Above 1GHz

                                                            Page 25
      This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                  Report No.: KS110407B01-EF                    FCC ID: ZFT-K105              Date of Issue: April 14, 2011


Model No.                    K105                                  Test Mode                  Mode 2
Environmental
                             26deg.C, 78% RH, 1010hPa              6dB Bandwidth              1 MHz
Conditions
Antenna Pole                 Horizontal                            Antenna Distance           3m
Detector Function            Peak or average.                      Tested by                  Star
Standard                     FCC CLASS B




 No.       Frequency      Reading         Correct         Result        Limit        Margin        Height    Degree     Remark

             (MHz)        (dBuV)      Factor(dB/m)      (dBuV/m)      (dBuV/m)        (dB)           (cm)     (°)

  1        2052.104        55.53           -9.01          46.52         74.00        -27.48          100      129         peak
  2        2052.104        37.82           -9.01          28.81         54.00        -25.19          100      120         AVG
  3        2991.984        50.51           -5.88          44.63         74.00        -29.37          100      256         peak
  4        2991.984        36.07           -5.88          30.19         54.00        -23.81          100      244         AVG
  5        6456.914        50.85           -0.70          50.15         74.00        -23.85          100       38         peak
  6        6456.914        30.47           -0.70          29.77         54.00        -24.23          100       13         AVG


Note:         1. The other emission levels were very low against the limit.




                                                             Page 26
       This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


            Report No.: KS110407B01-EF                    FCC ID: ZFT-K105             Date of Issue: April 14, 2011


PHOTOGRAPHS OF THE TEST CONFIGURATION
                                 CONDUCTED EMISSION TEST




                                                       Page 27
 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


           Report No.: KS110407B01-EF                    FCC ID: ZFT-K105             Date of Issue: April 14, 2011


                                  RADIATED EMISSION TEST




                                                      Page 28
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.



Document Created: 2011-04-20 10:55:03
Document Modified: 2011-04-20 10:55:03

© 2024 FCC.report