MPE Report

FCC ID: ZDEG2

RF Exposure Info

Download: PDF
FCCID_3913461

1. MAXIMUM PERMISSIBLE EXPOSURE (MPE)

1.1 General Information

 Client Information
 Applicant:                           ShenZhen Foscam Intelligent Technology Co., Limited
 Address of applicant:                Room A, 9/F, Block F5, TCL International E City, No. 1001
                                      Zhongshanyuan Road, Xili, Shenzhen, China

 Manufacturer:                        ShenZhen Foscam Intelligent Technology Co., Limited
 Address of manufacturer:             Room A, 9/F, Block F5, TCL International E City, No. 1001
                                      Zhongshanyuan Road, Xili, Shenzhen, China

 General Description of EUT:
 Product Name:                        Outdoor HD IP Camera
 Trade Name:                          FOSCAM
 Model No.:                           G2
                                      G2VX、G2C VX、G2E VX、G2 Plus VX、G2 Lite VX、G4 VX、G4C
                                      VX、G4E VX、G4 Plus VX、G4 Lite VX、FI9900P VX、FI9900EP VX、
 Adding Model(s):                     FI9901P VX、FI9901EP VX、FI9902P VX、FC5415P VX、FC5618P VX、
                                      FC5618EP VX、FC5718EP VX(which “X”can be from 0 to 9,the default
                                      state is null while it is V0)
 FCC ID:                              ZDEG2
 Rated Voltage:                       Power Port:DC12V

 Technical Characteristics of EUT:
 Support Standards:                802.11b, 802.11g, 802.11n
                                   2412-2462MHz for 802.11b/g/n(HT20)
 Frequency Range:
                                   2422-2452MHz for 802.11n(HT40)
 RF Output Power:                  9.66dBm (Conducted)
 Type of Modulation:               CCK, OFDM, QPSK, BPSK, 16QAM, 64QAM
 Data Rate:                        1-11Mbps, 6-54Mbps, up to 150Mbps
 Quantity of Channels:             11 for 802.11b/g/n(HT20); 7 for 802.11n(HT40)
 Channel Separation:               5MHz
 Type of Antenna:                  External Antenna
 Antenna Gain:                     2.0dBi

Note 1: The test data is gathered from a production sample provided by the manufacturer. The appearance of
others models listed in the report is different from main-test model MOPLUS, but the circuit and the electronic
construction do not change, declared by the manufacturer.


1.2 Standard Applicable

According to §1.1307(b)(1) and KDB 447498 D01 General RF Exposure Guidance v06, system operating under
the provisions of this section shall be operating in a manner that the public is not exposed to radio frequency
energy level in excess limit for maximum permissible exposure.

(a) Limits for Occupational / Controlled Exposure


                                Electric Field      Magnetic Field                              Averaging Times
         Frequency range                                                  Power Density
                                Strength (E)         Strength (H)                                | E |2, | H |2 or
             (MHz)                                                        (S) (mW/cm2)
                                   (V/m)                (A/m)                                      S (minutes)
              0.3-3.0                614                  1.63                (100)*                    6
              3.0-30               1842/f                4.89/f              (900/f)*                   6
              30-300                 61.4                0.163                  1.0                     6
             300-1500                 /                     /                 F/300                     6
           1500-100000                /                     /                    5                      6


(b) Limits for General Population / Uncontrolled Exposure


                                Electric Field      Magnetic Field                              Averaging Times
         Frequency range                                                  Power Density
                                Strength (E)         Strength (H)                                | E |2, | H |2 or
             (MHz)                                                        (S) (mW/cm2)
                                   (V/m)                (A/m)                                      S (minutes)
             0.3-1.34                614                  1.63                (100)*                   30
              1.34-30               824/f                2.19/f              (180/f)*                  30
              30-300                 27.5                0.073                  0.2                    30
             300-1500                 /                     /                 F/1500                   30
           1500-100000                /                     /                    1                     30
       Note: f = frequency in MHz: * = Plane-wave equivalents power density

1.3 MPE Calculation Method

S = (30*P*G) / (377*R2)
S = power density (in appropriate units, e.g., mw/cm2)
P = power input to the antenna (in appropriate units, e.g., mw)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator,
  the power gain factor is normally numeric gain.
R = distance to the center of radiation of the antenna (in appropriate units, e.g., cm)


1.4 MPE Calculation Result

WIFI2.4G:
Maximum Tune-Up output power: 9.66 (dBm)
Maximum peak output power at antenna input terminal: 9.25 (mW)
Prediction distance: >20(cm)
Prediction frequency: 2437 (MHz)
Antenna gain: 2.0 (dBi)
Directional gain (numeric gain): 1.58
The worst case is power density at prediction frequency at 20cm: 0.003(mw/cm2)
MPE limit for general population exposure at prediction frequency: 1 (mw/cm2)


Result: Pass


1.5 Test Setup Photos



Document Created: 2018-07-05 10:48:53
Document Modified: 2018-07-05 10:48:53

© 2025 FCC.report