RF Exposure Report

FCC ID: ZBCWD-241B

RF Exposure Info

Download: PDF
FCCID_4501140

                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch




                                                                   Report No.: SZEM190801731502
                                                                   Page:       1 of 9


1     COVER PAGE

                      Human Exposure Report
Application No.:          SZEM1908017315CR
Applicant:                SHENZHEN DNS INDUSTRIES CO., LTD.
Address of Applicant:     23/F Building A, Shenzhen International Innovation Center, No.1006
                          Shennan Road, Futian, shenzhen, 518026 China
Manufacturer:             SHENZHEN DNS INDUSTRIES CO., LTD.
Address of Manufacturer:  23/F Building A, Shenzhen International Innovation Center, No.1006
                          Shennan Road, Futian, Shenzhen, China
Factory:                  HUIZHOU D&S CABLE CO., LTD.
Address of Factory:       LONGJIN DONGJIANG INDUSTRY ZONE, SHUIKOU, HUICHENG,
                          HUIZHOU, GUANGDONG, CHINA
Equipment Under Test (EUT):
EUT Name:                 WIRELESS CHARGER
Model No.:                WD-241B, CRC#2046770 ♣
♣                         Please refer to section 3.2 of this report which indicates which model was
                          actually tested and which were electrically identical.
Trade mark:               DNS, omars, mbest, power zone, NOVOO
FCC ID:                   ZBCWD-241B
Standards:                47 CFR PART 1, Subpart I, Section 1.1310
                          47 CFR PART 2, Subpart J, Section 2.1091
Date of Receipt:          2019-08-09
Date of Test:             2019-08-14 to 2019-09-27
Date of Issue:            2019-10-08
Test Result :               Pass*
* In the configuration tested, the EUT complied with the standards specified above




             Keny Xu
      EMC Laboratory Manager


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                         Report No.: SZEM190801731502
                                                         Page:       2 of 9




                                       Revision Record
    Version        Chapter              Date                Modifier       Remark

     01                              2019-10-08                            Original




Authorized for issue by:




                             Peter Geng /Project Engineer




                             Eric Fu /Reviewer


                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                             Shenzhen Branch
                                                                                                 Report No.: SZEM190801731502
                                                                                                 Page:       3 of 9




2         Contents
1      COVER PAGE ..................................................................................................................................... 1

2      CONTENTS ......................................................................................................................................... 3

3      GENERAL INFORMATION .................................................................................................................. 4
    3.1    DETAILS OF E.U.T. ............................................................................................................................. 4
    3.2    DESCRIPTION OF SUPPORT UNITS ........................................................................................................ 4
    3.3    TEST LOCATION ................................................................................................................................. 5
    3.4    TEST FACILITY.................................................................................................................................... 5
    3.5    DEVIATION FROM STANDARDS .............................................................................................................. 5
    3.6    ABNORMALITIES FROM STANDARD CONDITIONS...................................................................................... 5
4      EQUIPMENTS USED DURING TEST .................................................................................................. 6

5      TEST RESULTS .................................................................................................................................. 7
    5.1 RF EXPOSURE TEST ........................................................................................................................... 7
       5.1.1 E.U.T. Operation ...................................................................................................................... 7
6      PHOTOGRAPHS- RF EXPOSURE SETUP ......................................................................................... 9


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                                  Report No.: SZEM190801731502
                                                                  Page:       4 of 9




3   General Information
3.1 Details of E.U.T.
    Power supply:              Input: DC 5V/2A, DC 9V/1.67A
                               Output: DC 5V/1A, DC 9V/1.1A
    Operation frequency        111.54kHz-162.02kHz
    Modulation type:           Load modulation
    Antenna type:              Inductive loop coil antenna
    Remark:                    1) Tests were conducted in both load modes and the worst case(10W) is
                                     reported only.
                               2) The device contains two inductive coils built-in, vertical and horizontal,
                                     tests were conducted in both condition and the worst case(vertical) is
                                     reported only.

3.2 Description of Support Units
    Description                          Manufacturer            Model No.               Serial No.
    Adapter                                   Apple           A1357 W010A051         REF. No.SEA0500
    Adapter                                SAMSUNG                EP-TA200           R37J8YA7W71DK3
    Adapter(for radiated emission)            LeTV               EQ-24BCN               65201C44220
    Micro USB Cable                         PHILIPS               SWR2101            REF. No.SEA0700
    SAMSUNG Galaxy S8                      SAMSUNG               SM-G9500               R28J9140LPB



     Declaration of EUT Family Grouping:

     Model No.: WD-241B, CRC#2046770

     Only the model WD-241B was tested, since the electrical circuit design, layout, components used,
     internal wiring and functions were identical for the above models, with only difference on the model.


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                               Report No.: SZEM190801731502
                                                               Page:       5 of 9




3.3 Test Location
     All tests were performed at:
     SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch E&E Lab,
     No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong,China
     518057.
     Tel: +86 755 2601 2053         Fax: +86 755 2671 0594
     No tests were sub-contracted.

3.4 Test Facility
    The test facility is recognized, certified, or accredited by the following organizations:
    • CNAS (No. CNAS L2929)
    CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
    Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
    Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
    Laboratories) for the competence in the field of testing.
    • A2LA (Certificate No. 3816.01)
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
    American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
    • VCCI
    The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
    Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
    Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
    been registered in accordance with the Regulations for Voluntary Control Measures with Registration
    No.: G-20026, R-14188, C-12383 and T-11153 respectively.
    • FCC –Designation Number: CN1178
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    as an accredited testing laboratory.
    Designation Number: CN1178. Test Firm Registration Number: 406779.
    • Innovation, Science and Economic Development Canada
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    by ISED as an accredited testing laboratory.
    CAB identifier: CN0006.
    IC#: 4620C.

3.5 Deviation from Standards
    None.

3.6 Abnormalities from Standard Conditions
    None.


                          SGS-CSTC Standards Technical Services Co., Ltd.
                          Shenzhen Branch
                                                         Report No.: SZEM190801731502
                                                         Page:       6 of 9




4   Equipments Used during Test

                                                              Inventory
    Item     Test Equipment        Manufacturer   Model No.               Cal. Due date
                                                                 No.

     1       Shielding Room          SAEMC        MSR733      SEM001-09     2020-05-09

           Electric and Magnetic
     2                                Narda       EHP-50F      EMC092       2020-05-06
              Field Analyzer


                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                 Shenzhen Branch
                                                                     Report No.: SZEM190801731502
                                                                     Page:       7 of 9




5       Test Results
5.1 RF Exposure test
        Test Requirement:               47 CFR PART 1, Subpart I, Section 1.1310
        Measurement Distance:           15cm
        Limit:

    Frequency range Electric field strength Magnetic field strength Power density Averaging time
         (MHz)               (V/m)                  (A/m)             (mW/cm2)      (minutes)
                             (A) Limits for Occupational/Controlled Exposures
           0.3-3.0                614                      1.63               *(100)              6
           3.0-30                1842/f                    4.89/f            *(900/f 2)           6
           30-300                 61.4                     0.163                1.0               6
          300-1500                  /                        /                 f/300              6
        1500-100,000                /                        /                     5              6
                          (B) Limits for General Population/Uncontrolled Exposure
          0.3-1.34                614                      1.63               *(100)             30
           1.34-30               824/f                     2.19/f            *(180/f 2)          30
           30-300                 27.5                     0.073                0.2              30
          300-1500                  /                        /                f/1500             30
        1500-100,000                /                        /                  1.0              30
    F=frequency in MHz
    *=Plane-wave equivalent power density
    RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of the FCC
    rules. The emissions should be within the limits at 300kHz in Table 1 of 1.1310(use the 300kHz limits
    for 150kHz:614V/m,1.63A/m).
5.1.1     E.U.T. Operation

        Operating Environment:
        Temperature:     24.0 °C            Humidity:   52 % RH         Atmospheric Pressure: 1015 mbar

        EUT Operation:
        This device has been tested with mobile phone at zero charge, intermediate charge, and full
         charge.


                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                 Shenzhen Branch
                                                                    Report No.: SZEM190801731502
                                                                    Page:       8 of 9




5.1.2   Measurement Data


        Output Voltage=DC 9V; The max output power =10W
        Magnetic Field Emissions
          Operation     Test Distance      Test Position         Probe Measure      50% Limit
          frequency                                               Result (A/m)
                                 (cm)                                                    (A/m)

                                                  Side 1              0.1138              0.815
                                                  Side 2              0.1882              0.815
            141 kHz               15              Side 3              0.1264              0.815
                                                  Side 4              0.0659              0.815
                                                   Top                0.0983              0.815

        Mobile phone has been charge at zero charge, intermediate charge, and full charge.

        Magnetic Field Emissions

         Operation       Test                              Probe Measure Result(A/m)
                                         Test                                                50%Limit
         frequency     Distance
                                        Position     zero        intermediate   full
                                                     charge         charge      charge            (A/m)
                           (cm)

                                         Side 1       0.1254        0.1133       0.0998           0.815
                                         Side 2       0.1982        0.1836       0.1693           0.815
          141 kHz           15           Side 3       0.1359        0.1415       0.1083           0.815
                                         Side 4       0.0793        0.0637       0.0512           0.815
                                          Top         0.1102        0.0986       0.0841           0.815


                 SGS-CSTC Standards Technical Services Co., Ltd.
                 Shenzhen Branch
                                                Report No.: SZEM190801731502
                                                Page:       9 of 9



6   Photographs- RF exposure setup




                        - End of the Report -



Document Created: 2019-10-25 09:25:12
Document Modified: 2019-10-25 09:25:12

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC