LCS190805070AEA_WPT 15 Report

FCC ID: ZBCCK102A

Test Report

Download: PDF
FCCID_4475152

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: ZBCCK102A            Report No.: LCS190805070AEA




                                                 FCC TEST REPORT
                                                               FOR
                               SHENZHEN DNS INDUSTRIES CO., LTD
                                     Type C HUB with Wireless Charger
                                                 Test Model: CK-102A
                            Additional Model No.: Please Refer to Page 6




   Prepared for                              :   SHENZHEN DNS INDUSTRIES CO., LTD
   Address                                   :   23/F Building A, Shenzhen International Innovation Center,
                                                 No.1006 Shennan Road, Futian, Shenzhen, China

   Prepared by                               :   Shenzhen LCS Compliance Testing Laboratory Ltd.
   Address                                   :   101, 601, Xingyuan Industrial Park, Tongda Road, Bao’an
                                                 Avenue, Bao’an District, Shenzhen, Guangdong, China
   Tel                                       :   (+86)755-82591330
   Fax                                       :   (+86)755-82591332
   Web                                       :   www.LCS-cert.com
   Mail                                      :   webmaster@LCS-cert.com

   Date of receipt of test sample            :   August 07, 2019
   Number of tested samples                  :   1
   Serial number                             :   Prototype
   Date of Test                              :   August 08, 2019 ~ August 15, 2019
   Date of Report                            :   August 16, 2019




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 1 of 21


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: ZBCCK102A     Report No.: LCS190805070AEA


                                                    FCC TEST REPORT
                                                   FCC CFR 47 PART 15C

  Report Reference No. ............... : LCS190805070AEA

  D&t@ Of ISSU® ... : August 16, 2019

 Testing Laboratory Name............ : Shenzhen LCS Compliance Testing Laboratory Ltd.

  AUQFOSS ..........llseeeeeerermeeeees : 101, 601, Xingyuan Industrial Park, Tongda Road, Bac‘an
                                          Avenue, Bac‘an District, Shenzhen, Guangdong, China

  Testing Location/ Procedure .......... : Full application of Harmonised standards m
                                                   Partial application of Harmonised standards o

                                                   Other standard testing method o

 ApPDIiC@NTS N@MQ .....cennnnecceereeeenss : SHENZHEN DNS INDUSTRIES CO., LTD
  fole (o o—— ie : 23/F Building A, Shenzhen International Innovation Center,
                                                   No.1006 Shennan Road, Futian, Shenzhen, China
 Test Specification

  St@NU@FQ . .....222000000ccsiveeeeeeeeeeeeeeee e : FCC CFR 47 PART 15C

  Test Report Form No. ... : LCSEMC—1.0

  TRF OFIGIN@IOF. ... : Shenzhen LCS Compliance Testing Laboratory Ltd.

  MaSter TRF ... : Dated 2011—03

  Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved.
 This publication may be reproduced in whole or in part for non—commercial purposes as long as the
 Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of
 the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not
 assume liability for damages resulting from the reader‘s interpretation of the reproduced material due to
 its placement and context.
 Test Item Description.................. : Type C HUB with Wireless Charger

  Tr@U® M@IK ............lcccceeeeeee. : DNS, QDOS

  TeSt MOGUBI.............lccccemeeeeee : CK—102A

  R&tIAGS ... : Input :PD 6OW
                                                   USB 3.0 Output: DC 5V, 0.9A,
                                                   USB 2.0 Output :DC 5V, 0.5A Ceach)

                                                   USB 3.0+2*USB 2.0 total Output :7ZW
                                                  Wireless charger Output :S5W, 7.5W, 10W
  R@SUIE ......ccmmemneeeeemmmmmmnnnnerrrrenernenes : Positive


               Compiled by:                                      Supervised by:                        Approved by:

            \lff:&n >huweo                                       Afii.fi Jin                          4,/,:@ Pere


   This report shullnot berepmduced except in full, without the written approval of Shenzhen LCS Complmnce Tesnng Labommry Ltd.
                                                                 Page 2 of21


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: ZBCCK102A            Report No.: LCS190805070AEA


                                               FCC -- TEST REPORT

                                                                                                August 16, 2019
      Test Report No. :                        LCS190805070AEA                                   Date of issue



    Test Model........................           : CK-102A

    EUT....................................      : Type C HUB with Wireless Charger


    Applicant...........................         : SHENZHEN DNS INDUSTRIES CO., LTD
    Address..............................        : 23/F Building A, Shenzhen International Innovation Center,
                                                   No.1006 Shennan Road, Futian, Shenzhen, China
    Telephone..........................          : /
    Fax.....................................     : /


    Manufacturer.....................            : SHENZHEN DNS INDUSTRIES CO., LTD
    Address..............................        : 23/F Building A, Shenzhen International Innovation Center,
                                                   No.1006 Shennan Road, Futian, Shenzhen, China
    Telephone..........................          : /
    Fax.....................................     : /



    Factory..............................        : HUIZHOU D&S CABLE CO., LTD.
    Address..............................        : Longjin Dongjiang Industry ZoneShuikou, Huicheng, Huizhou,
                                                   Guangdong, China
    Telephone..........................          : /
    Fax.....................................     : /




                            Test Result                                                     Positive


   The test report merely corresponds to the test sample.
   It is not permitted to copy extracts of these test result without the written permission of the test
   laboratory.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 3 of 21


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: ZBCCK102A            Report No.: LCS190805070AEA



                                                        Revision History

          Revision                       Issue Date                           Revisions                        Revised By
            000                        August 16, 2019                       Initial Issue                     Gavin Liang




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 4 of 21


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                       FCC ID: ZBCCK102A                  Report No.: LCS190805070AEA



                                                      TABLE OF CONTENTS

    1. GENERAL INFORMATION ......................................................................................................... 6
       1.1 Description of Device (EUT) .............................................................................................................. 6
       1.2 Support equipment List ....................................................................................................................... 6
       1.3 External I/O Cable ............................................................................................................................... 6
       1.4 Description of Test Facility ................................................................................................................. 7
       1.5 Statement of the Measurement Uncertainty .................................................................................... 7
       1.6 Measurement Uncertainty .................................................................................................................. 7
       1.7 Description of Test Modes.................................................................................................................. 8
    2. TEST METHODOLOGY .............................................................................................................. 9
       2.1 EUT Configuration ............................................................................................................................... 9
       2.2 EUT Exercise........................................................................................................................................ 9
       2.3 General Test Procedures ................................................................................................................... 9
       2.3.1 Conducted Emissions ...................................................................................................................... 9
       2.3.2 Radiated Emissions ......................................................................................................................... 9
    3. SYSTEM TEST CONFIGURATION ......................................................................................... 10
       3.1 Justification ......................................................................................................................................... 10
       3.2 EUT Exercise Software ..................................................................................................................... 10
       3.3 Special Accessories .......................................................................................................................... 10
       3.4 Block Diagram/Schematics .............................................................................................................. 10
       3.5 Equipment Modifications .................................................................................................................. 10
       3.6 Test Setup........................................................................................................................................... 10
    4. SUMMARY OF TEST EQUIPMENT ........................................................................................ 11
    5. SUMMARY OF TEST RESULT ................................................................................................ 12
    6. POWER LINE CONDUCTED MEASUREMENT ................................................................... 13
    7. RADIATED EMISSION MEASUREMENT .............................................................................. 15
       7.1. Block Diagram of Test Setup .......................................................................................................... 15
       7.2. Radiated Emission Limit .................................................................................................................. 16
       7.3. EUT Configuration on Measurement ............................................................................................. 16
       7.4. Operating Condition of EUT ............................................................................................................ 16
       7.5. Measuring Setting ............................................................................................................................. 17
       7.6. Test Procedure ................................................................................................................................. 17
       7.7. Test Results....................................................................................................................................... 18
    8. PHOTOGRAPHS OF TEST SETUP ........................................................................................ 21
    9. EXTERNAL PHOTOGRAPHS OF THE EUT ......................................................................... 21
    10. INTERNAL PHOTOGRAPHS OF THE EUT ........................................................................ 21




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                         Page 5 of 21


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: ZBCCK102A            Report No.: LCS190805070AEA




1. GENERAL INFORMATION

   1.1 Description of Device (EUT)

        EUT                              :   Type C HUB with Wireless Charger
        Test Model                       :   CK-102A
        Additional Model No.             :   QD-5139C-HUB, QD-5139C-HUBSG
                                             All the models are identical with each other except the model
                                             name is different, therefore, full test was applied on CK-102A,
        Model Declaration                :
                                             other models are deemed to fulfill the requirement without
                                             further test.
        Hardware Version                 :   /
        Software Version                 :   /
        Operating Frequency              :   110KHz~205.0KHz
        Modulation Type                  :   CW (Continuous Wave)
        Antenna Type                     :   Coil Antenna
        Power supply                     :   Input :PD 60W
                                             USB 3.0 Output: DC 5V, 0.9A,
                                             USB 2.0 Output :DC 5V, 0.5A(each)
                                             USB 3.0+2*USB 2.0 total Output :7W
                                             Wireless charger Output :5W, 7.5W, 10W

   1.2 Support equipment List

           Manufacturer                  Description                    Model              Serial Number          Certificate
            Apple Inc.                  Mobile Phone                  iphone X                    --                FCC


   1.3 External I/O Cable

               I/O Port Description                          Quantity                                 Cable
                 Micro USB Port                                2                                       N/A




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 6 of 21


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: ZBCCK102A            Report No.: LCS190805070AEA




   1.4 Description of Test Facility


    FCC Registration Number is 254912.
    Industry Canada Registration Number is 9642A-1.
    EMSD Registration Number is ARCB0108.
    UL Registration Number is 100571-492.
    TUV SUD Registration Number is SCN1081.
    TUV RH Registration Number is UA 50296516-001.
    NVLAP Accreditation Code is 600167-0.
    FCC Designation Number is CN5024.
    CAB identifier: CN0071
    The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.4:2014 and CISPR
    16-1-4:2010 SVSWR requirement for radiated emission above 1GHz.

   1.5 Statement of the Measurement Uncertainty
    The data and results referenced in this document are true and accurate. The reader is cautioned that
    there may be errors within the calibration limits of the equipment and facilities. The measurement
    uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 – 4
    “Specification for radio disturbance and immunity measuring apparatus and methods – Part 4:
    Uncertainty in EMC Measurements” and is documented in the LCS quality system acc. to DIN EN
    ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may
    result in additional deviation. The manufacturer has the sole responsibility of continued compliance of
    the device.

   1.6 Measurement Uncertainty
                    Test Item                       Frequency Range                      Uncertainty                Note
                                                      9KHz~30MHz                          3.10dB                     (1)
                                                    30MHz~200MHz                          2.96dB                     (1)
            Radiation Uncertainty           :      200MHz~1000MHz                         3.10dB                     (1)
                                                     1GHz~26.5GHz                         3.80dB                     (1)
                                                    26.5GHz~40GHz                         3.90dB                     (1)
           Conduction Uncertainty :                  150kHz~30MHz                         1.63dB                     (1)
             Power disturbance    :                 30MHz~300MHz                          1.60dB                     (1)

    (1) This uncertainty represents an expanded uncertainty expressed at approximately the 95%
    confidence level using a coverage factor of k=2.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 7 of 21


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: ZBCCK102A            Report No.: LCS190805070AEA



   1.7 Description of Test Modes
    Equipment under test was operated during the measurement under the following conditions:
         Charging and communication mode
    Modulation Type: CW (Continuous Wave)


      Test Modes:
      Mode 1       AC/DC Adapter + EUT + Mobile Phone (Battery Status: <1%)                             Record
      Mode 2       AC/DC Adapter + EUT + Mobile Phone (Battery Status: <50%)                            Pre-tested
      Mode 3       AC/DC Adapter + EUT + Mobile Phone (Battery Status: 100%)                            Pre-tested
       Note: All test modes were pre-tested, but we only recorded the worst case in this report.


    For AC conducted emission, pre-test at both AC 120V/60Hz and AC 240V/50Hz, recorded worst case;




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 8 of 21


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: ZBCCK102A            Report No.: LCS190805070AEA




2. TEST METHODOLOGY
    The tests documented in this report were performed in accordance with ANSI C63.10-2013, FCC CFR
    PART 15C 15.207 and 15.209.

   2.1 EUT Configuration
    The EUT configuration for testing is installed on RF field strength measurement to meet the
    Commissions requirement and operating in a manner that intends to maximize its emission
    characteristics in a continuous normal application.

   2.2 EUT Exercise
    The EUT was operated in the charging and compunction mode to fix the TX frequency that was for the
    purpose of the measurements.
    According to its specifications, the EUT must comply with the requirements of the Section 15.207 and
    15.209 under the FCC Rules Part 15 Subpart C.

   2.3 General Test Procedures

   2.3.1 Conducted Emissions
    The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the requirements
    in Section 13.1.4.1 of ANSI C63.10-2013 Conducted emissions from the EUT measured in the
    frequency range between 0.15 MHz and 30MHz using Quasi-peak and average detector modes.

   2.3.2 Radiated Emissions
    The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable shall rotate 360
    degrees to determine the position of maximum emission level. EUT is set 3m away from the receiving
    antenna, which varied from 1m to 4m to find out the highest emission. And also, each emission was to
    be maximized by changing the polarization of receiving antenna both horizontal and vertical. In order
    to find out the maximum emissions, exploratory radiated emission measurements were made
    according to the requirements in Section 13.1.4.1 of ANSI C63.10-2013




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 9 of 21


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: ZBCCK102A            Report No.: LCS190805070AEA




3. SYSTEM TEST CONFIGURATION

   3.1 Justification
    The system was configured for testing in a normal condition.

   3.2 EUT Exercise Software
    N/A.

   3.3 Special Accessories
                                                                                                    shielded/
         No.        Equipment            Manufacturer         Model No.          Serial No.                           Notes
                                                                                                   unshielded
                                             Mobile                                                                  Mobile
           1        Apple Inc.                                 iphone X               --            Apple Inc.
                                             Phone                                                                   Phone


   3.4 Block Diagram/Schematics
    Please refer to the related document.

   3.5 Equipment Modifications
    Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification on the EUT.

   3.6 Test Setup
    Please refer to the test setup photo.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 10 of 21


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: ZBCCK102A              Report No.: LCS190805070AEA




4. SUMMARY OF TEST EQUIPMENT
Item                Equipment                   Manufacturer          Model No.              Serial No.          Cal Date       Due Date
 1              MXA Signal Analyzer                 Agilent             N9020A             MY49100040          2019-06-11      2020-06-10
 2             SPECTRUM ANALYZER                     R&S                 FSP40                100503           2018-11-15      2019-11-14
 3          3m Semi Anechoic Chamber           SIDT FRANKONIA           SAC-3M              03CH03-HY          2019-06-12      2020-06-11
 4             Positioning Controller                 MF               MF-7082                   /             2019-06-12      2020-06-11
 5               EMI Test Software                  AUDIX                  E3                    /                 N/A             N/A
 6               EMI Test Receiver                   R&S                 ESR 7                101181           2019-06-12      2020-06-11
 7             Active Loop Antenna              SCHWARZBECK          FMZB 1519B               00005            2019-07-25      2020-07-24
 8                By-log Antenna                SCHWARZBECK            VULB9163              9163-470          2019-07-25      2020-07-24
 9                 Horn Antenna                 SCHWARZBECK          BBHA 9120D            9120D-1925          2019-07-01      2020-06-30
 10               RF Cable-R03m                    Jye Bao               RG142                CB021            2019-06-12      2020-06-11
 11                RF Cable-HIGH                   SUHNER           SUCOFLEX 106            03CH03-HY          2019-06-12      2020-06-11
 12              EMI Test Receiver                   R&S                  ESPI                101840           2019-06-11      2020-06-10
 13               Artificial Mains                   R&S                ENV216                101288           2019-06-12      2020-06-11
 14              10dB Attenuator                SCHWARZBECK          MTS-IMP-136        261115-001-0032        2019-06-11      2020-06-10
Note: All equipment is calibrated through CHINA CEPREI LABORATORY and GUANGZHOU LISAI CALIBRATION AND TEST CO., LTD.




     This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                Page 11 of 21


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: ZBCCK102A            Report No.: LCS190805070AEA




5. SUMMARY OF TEST RESULT
                         FCC Rule         Temperature          Power source
    Test Item                                                                        C        NC          NA         NP        Remark
                           No.             conditions           conditions
   Radiated
                          §15.209            Nominal               Nominal                                                        -/-
   Emission
 AC conducted
                          §15.207            Nominal               Nominal                                                        -/-
   emission

Remark: The measurement uncertainty is not included in the test result.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                              Page 12 of 21


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         ECC ID: ZBCCKI02A            Report No.: LCS190805070AEA




6. POWER LINE CONDUCTED MEASUREMENT
   6.1. Block Diagram of Test Setup



                                     Vert. reference plane



                                                                                         EMI Receiver
                                            EUT & Auxiliary Equipment                            800
                                                                                                    800
                                                                                        /\’VDDQ


                            LISN
                           qo
                                                               \ Reference ground plane

   6.2. Standard Applicable
   According to §15.207: For all the consumer devices which is designed to be connected to the public
   utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any
   frequency or frequencies within the band 150 kHz to 30 MHz shall not exeeed 250 microvolts (The limit
   decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz). The limits at
   specific frequency range are listed as follows:

          Frequency Range                                                      Limits (dBuV)
                 (MH2z)                                   Quasi—peak                                      Average
              0.15 to 0.50                                 66 to 56                                       56 to 46
               0.50 to 5                                      56                                             46
                 5 to 30                                        60                                           50

   * Decreasing linearly with the logarithm of the frequency


   6.3 Test Results
    PASS.
    The test data please refer to following page.

            Temperature                        25.1°C                       Humidity                         59.2%
            Test Engineer                 Wang Chuang




  This report shall not be reproduced except in full, without the written approval of Shenthen LCS ComplianceTesting Laboratory Ltd.
                                                             Page 13 of21


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: ZBCCK102A            Report No.: LCS190805070AEA



AC Conducted Emission of charge from power adapter mode @ AC 240V/50Hz

Line




Neutral




***Note: Pre-scan all modes and recorded the worst case results in this report.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                              Page 14 of 21


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: ZBCCK102A            Report No.: LCS190805070AEA




7. RADIATED EMISSION MEASUREMENT
   7.1. Block Diagram of Test Setup




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 15 of 21


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: ZBCCK102A            Report No.: LCS190805070AEA



   7.2. Radiated Emission Limit


     15.205 (a) Except as shown in paragraph (d) of this section, only spurious emissions are permitted in
     any of the frequency bands listed below:

             MHz                             MHz                               MHz                      GHz
             0.090-0.110                     16.42-16.423                      399.9-410                4.5-5.15
             \1\ 0.495-0.505                 16.69475-16.69525                 608-614                  5.35-5.46
             2.1735-2.1905                   16.80425-16.80475                 960-1240                 7.25-7.75
             4.125-4.128                     25.5-25.67                        1300-1427                8.025-8.5
             4.17725-4.17775                 37.5-38.25                        1435-1626                9.0-9.2
             4.20725-4.20775                 73-74.6                           1645.5-1646.5            9.3-9.5
             6.215-6.218                     74.8-75.2                         1660-1710                10.6-12.7
             6.26775-6.26825                 108-121.94                        1718.8-1722.2            13.25-13.4
             6.31175-6.31225                 123-138                           2200-2300                14.47-14.5
             8.291-8.294                     149.9-150.05                      2310-2390                15.35-16.2
             8.362-8.366                     156.52475-156.52525               2483.5-2500                17.7-21.4
             8.37625-8.38675                 156.7-156.9                       2690-2900                22.01-23.12
             8.41425-8.41475                 162.0125-167.17                   3260-3267                23.6-24.0
             12.29-12.293.                   167.72-173.2                      3332-3339                31.2-31.8
             12.51975-12.52025               240-285                           3345.8-3358              36.43-36.5
             12.57675-12.57725               322-335.4                         3600-4400                (\2\)
             13.36-13.41
     \1\ Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
     \2\ Above 38.6

                Frequencies                                Field Strength                        Measurement Distance
                   (MHz)                                 (microvolts/meter)                            (meters)
                0.009~0.490                                 2400/F(KHz)                                  300
                0.490~1.705                                24000/F(KHz)                                  30
                1.705~30.0                                       30                                      30
                   30~88                                        100                                       3
                  88~216                                        150                                       3
                  216~960                                       200                                       3
                 Above 960                                      500                                       3

   7.3. EUT Configuration on Measurement

The following equipment are installed on Radiated Emission Measurement to meet the commission
requirements and operating regulations in a manner which tends to maximize its emission characteristics in
normal application.

   7.4. Operating Condition of EUT

(1) Setup the EUT as shown in Section 4.1.
(2) Let the EUT work in worst test mode (Mode 1) and measure it.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                              Page 16 of 21


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: ZBCCK102A            Report No.: LCS190805070AEA



   7.5. Measuring Setting
    The following table is the setting of spectrum analyzer and receiver.

         Receiver Parameter                                     Setting
         Attenuation                                            Auto
         Start ~ Stop Frequency                                 9kHz~150kHz / RB 200Hz for QP/Average
         Start ~ Stop Frequency                                 150kHz~30MHz / RB 9kHz for QP/Average
         Start ~ Stop Frequency                                 30MHz~1000MHz / RB 120kHz for QP

   7.6. Test Procedure
    1) Sequence of testing 9 kHz to 30 MHz
    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or
    described by manufacturer.
    --- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used.
    --- If the EUT is a floor standing device, it is placed on the ground.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions.
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.
    Premeasurement:
    --- The turntable rotates from 0°to 315°using 45°steps.
    --- The antenna height is 0.8 meter.
    --- At each turntable position the analyzer sweeps with peak detection to find the maximum of all
    emissions
    Final measurement:
    --- Identified emissions during the premeasurement the software maximizes by rotating the turntable
    position (0°to 360°) and by rotating the elevation axes (0°to 360°).
    --- The final measurement will be done in the position (turntable and elevation) causing the highest
    emissions with.
    --- The final levels, frequency, measuring time, bandwidth, turntable position, correction factor, margin
    to the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit
    will be stored.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 17 of 21


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: ZBCCK102A            Report No.: LCS190805070AEA




     2) Sequence of testing 30 MHz to 1 GHz
     Setup:
     --- The equipment was set up to simulate a typical usage like described in the user manual or
     described by manufacturer.
     --- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground
     plane.
     --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
     --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
     --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
     --- The measurement distance is 3 meter.
     --- The EUT was set into operation.
     Premeasurement:
     --- The turntable rotates from 0°to 315°using 45°steps.
     --- The antenna is polarized vertical and horizontal.
     --- The antenna height changes from 1 to 3 meter.
     --- At each turntable position, antenna polarization and height the analyzer sweeps three times in peak
     to find the maximum of all emissions.
     Final measurement:
     --- The final measurement will be performed with minimum the six highest peaks.
     --- According to the maximum antenna and turntable positions of premeasurement the software
     maximize the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4
     meter.
     --- The final measurement will be done with QP detector with an EMI receiver.
     --- The final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization,
     turntable angle, correction factor, margin to the limit and limit will be recorded. Also a plot with the
     graph of the premeasurement with marked maximum final measurements and the limit will be stored.

   7.7. Test Results

    PASS.

Only report the worst test data (Mode 1) in test report;
The test data please refer to following page:

             Temperature                     23.8℃                            Humidity                        53.7%
             Test Engineer                 Wang Chuang




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                              Page 18 of 21


   a2.5
                                                                                    ncE mt cor—sor
   55.0        7
                      fulis          a       5

   ars


       *%a0s        o2        s          a                          2           s       10     20    30
Bnv./Ins:                           as.e°C/so.7e
por
               Freq       Reading        CabLos   Antfac   Measured      Limit       Over     Remark
                   rin=    abuy              an   aB/m     dBuy/m       aBuy/m        an
   1                      a7.55           o .30    o .00    a7.es     isa.s1        —7e.5e      or
   2                      a7.10           o.30     0.00     av.ao      asi.36       —73.96      or
   3                      a2.32           o.30     0.00     az.es      ai8.21        —75.59     or
   a                      40.20           o.30     0.00     40.s0      qi6.11       —75.si      or
   s                      40. 41.         o.30     0.00     a0.71     i08.74         —es.03     or
   e                      a2.29           o.30     0.00     a2.ss     108.
Note: 1. All readings are Quasi—pesk velues.
2. Measured= Resding + Antenna Factor + Cable Loss
3. The emission that are 20db below the official limit are not reported


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: ZBCCK102A            Report No.: LCS190805070AEA

30MHz~1000MHz

Horizontal




Vertical




     Note:
     1). Pre-scan all modes and recorded the worst case results in this report.
     2). Emission level (dBuV/m) = 20 log Emission level (uV/m).
     3). Corrected Reading: Antenna Factor + Cable Loss + Read Level = Level.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                              Page 20 of 21


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: ZBCCK102A            Report No.: LCS190805070AEA




8. PHOTOGRAPHS OF TEST SETUP

   Please refer to separated files for Test Setup Photos of the EUT.


9. EXTERNAL PHOTOGRAPHS OF THE EUT

  Please refer to separated files for External Photos of the EUT.


10. INTERNAL PHOTOGRAPHS OF THE EUT

  Please refer to separated files for Internal Photos of the EUT.




                              -------------THE END OF REPORT-------------




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 21 of 21



Document Created: 2019-10-11 01:09:26
Document Modified: 2019-10-11 01:09:26

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC