RF Exposure Info

FCC ID: ZBCAC75L4C

RF Exposure Info

Download: PDF
FCCID_4005204

                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch

No. 1 Workshop, M-10, Middle Section, Science & Technology Park,
Shenzhen, China 518057
Telephone:            +86 (0) 755 2601 2053                                                                                        Report No.: SZEM180600493502
Fax:                  +86 (0) 755 2671 0594
                                                                                                                                   Page:      1 of 10
Email:                ee.shenzhen@sgs.com


                                           Human Exposure Report
Application No.:                                           SZEM1806004935CR
Applicant:                                                 SHENZHEN DNS INDUSTRIES CO., LTD.
Address of Applicant:                                      23/F Building A, Shenzhen International Innovation Center, No.1006 Shennan
                                                           Road, Futian, Shenzhen, China
Manufacturer:                                              SHENZHEN DNS INDUSTRIES CO., LTD.
Address of Manufacturer:                                   23/F Building A, Shenzhen International Innovation Center, No.1006 Shennan
                                                           Road, Futian, Shenzhen, China
Factory:                                                   HUIZHOU D&S CABLE CO., LTD.
Address of Factory:                                        LONGJIN DONGJIANG INDUSTRY                                                      ZONE,            SHUIKOU,                 HUICHENG,
                                                           HUIZHOU, GUANGDONG, CHINA
Equipment Under Test (EUT):
EUT Name:                                                  WIRELESS CHARGER
Model No.:                                                 AC75L4C, AC75L4N, WD19L4C, WD19L4N ♣
♣                                                          Please refer to section 2.1 of this report which indicates which model was
                                                           actually tested and which were electrically identical.
FCC ID:                                                    ZBCAC75L4C
Trade mark:                                                DNS
Standards:                                                 47 CFR PART 1, Subpart I, Section 1.1310
Date of Receipt:                                           2018-06-08
Date of Test:                                              2018-06-20 to 2018-06-22
Date of Issue:                                             2018-06-22
Test Result :                                                 Pass*

* In the configuration tested, the EUT complied with the standards specified above




                   Keny Xu
             EMC Laboratory Manager
The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report.
If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new
system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS
International Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by SGS
International Electrical Approvals in writing.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights
and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification
of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the
sample(s) tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                             Report No.: SZEM180600493502
                                                                                                                             Page:       2 of 10


1          Contents
                                                                                                                                                                                                 Page
1         COVER PAGE ............................................................................................................................................1

1         CONTENTS .............................................................................................................................................................. 2

2         GENERAL INFORMATION .................................................................................................................................... 3
     2.1       DETAILS OF E.U.T. ................................................................................................................................................. 3
     2.2       DESCRIPTION OF SUPPORT UNITS ............................................................................................................................ 4
     2.3       TEST LOCATION ...................................................................................................................................................... 5
     2.4       TEST FACILITY ........................................................................................................................................................ 5
     2.5       DEVIATION FROM STANDARDS................................................................................................................................ 5
     2.6       ABNORMALITIES FROM STANDARD CONDITIONS .................................................................................................... 5
3         EQUIPMENTS USED DURING TEST .................................................................................................................. 6

4         TEST RESULTS ...................................................................................................................................................... 7
     4.1 RF EXPOSURE TEST ................................................................................................................................................ 7
        4.1.1 E.U.T. Operation ........................................................................................................................................ 7
        4.1.2 Measurement Data .................................................................................................................................... 8
5         PHOTOGRAPHS ................................................................................................................................................... 10




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                             Report No.: SZEM180600493502
                                                                                                                             Page:       3 of 10



2          General Information
2.1 Details of E.U.T.
           Power supply:                                      AC/DC adapter information:
                                                              MODEL: AC74S29
                                                              INPUT: AC 100-240V, 50/60Hz, 1.1A
                                                              OUTPUT: DC 12V/3.5A
                                                              for wireless charge pad:
                                                              Input: DC 12V/3.5A
                                                              Output 1: DC 5V/1A, OR 9V/1.67A, OR 12V/1.25A
                                                              Output 2: DC 5V/1A, OR 9V/1.67A, OR 12V/1.25A
                                                              30W MAX
           Cable:                                             DC line: 150cm, unshielded
           Operation frequency:                               129.3-183.7kHz
           Antenna type:                                      Inductive Loop Coil Antenna
           Modulation type:                                   Load modulation
           Remark:                                            Tests were conducted in all load modes(5W/10W/15W/30W) and the worst
                                                              case (30W) is reported only.

            Declaration of EUT Family Grouping:
            Model No.: AC75L4C, AC75L4N, WD19L4C, WD19L4N
            Only the model AC75L4C was tested, since the electrical circuit design, PCB layout, components used
            and internal wiring and functions were identical for the above models, only different on model number,
            appearance, capacitance type, Power panel and indicator circuit.
            Details see below:
                                                                                                                                                           capacitance
                     Trade mark                         Model number                             appearance
                                                                                                                                   NPO capacitance                       CBB capacitance

                           DNS                               AC75L4C                                  Type 1                                    NO                                   YES

                           DNS                               AC75L4N                                  Type 1                                   YES                                    NO

                           DNS                              WD19L4C                                   Type 2                                    NO                                   YES

                           DNS                              WD19L4N                                   Type 2                                   YES                                    NO




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                             Report No.: SZEM180600493502
                                                                                                                             Page:       4 of 10




2.2 Description of Support Units
             Description                                            Manufacturer                                          Model No.                                         Serial No.
             E-loading                                           Provided by client                                              N/A                                      DC 5V/1A
             E-loading                                           Provided by client                                              N/A                                     DC 9V/1.67A
             E-loading                                           Provided by client                                              N/A                                     DC 12V/1.25A




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                             Report No.: SZEM180600493502
                                                                                                                             Page:       5 of 10




2.3 Test Location
             All tests were performed at:
             SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch
             No. 1 Workshop, M-10, Middle Section, Science & Technology Park, Shenzhen, Guangdong, China.
             518057.
             Tel: +86 755 2601 2053                                  Fax: +86 755 2671 0594
             No tests were sub-contracted.

2.4 Test Facility
           The test facility is recognized, certified, or accredited by the following organizations:
           • CNAS (No. CNAS L2929)
           CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
           Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
           Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
           Laboratories) for the competence in the field of testing.
           • A2LA (Certificate No. 3816.01)
           SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
           American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
           • VCCI
           The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
           Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
           Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
           been registered in accordance with the Regulations for Voluntary Control Measures with Registration
           No.: G-20026, R-14188, C-12383 and T-11153 respectively.
           • FCC –Designation Number: CN1178
           SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
           as an accredited testing laboratory.
           Designation Number: CN1178. Test Firm Registration Number: 406779.
           • Industry Canada (IC)
           Two 3m Semi-anechoic chambers and the 10m Semi-anechoic chamber of SGS-CSTC Standards
           Technical Services Co., Ltd. Shenzhen Branch EMC Lab have been registered by Certification and
           Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 4620C-1,
           4620C-2, 4620C-3.

2.5 Deviation from Standards
           None.

2.6 Abnormalities from Standard Conditions
           None.


This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                             Report No.: SZEM180600493502
                                                                                                                             Page:       6 of 10




3          Equipments Used during Test

                                                                                                                                          Inventory                 Cal. Due date
             Item               Test Equipment                             Manufacturer                        Model No.
                                                                                                                                             No.                      (yyyy-mm-dd)

                1             Electric Field Meter                             Schaffner                          EMC20                    EMC068                      2019-03-21




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                             Report No.: SZEM180600493502
                                                                                                                             Page:       7 of 10



4          Test Results
4.1 RF Exposure test
           Test Requirement:                                        47 CFR PART 1, Subpart I, Section 1.1310
           Measurement Distance:                                    15cm
           Limit:

      Frequency range Electric field strength Magnetic field strength Power density Averaging time
           (MHz)               (V/m)                  (A/m)             (mW/cm2)      (minutes)
                                                    (A) Limits for Occupational/Controlled Exposures
                 0.3-3.0                                     614                                           1.63                                  *(100)                              6
                 3.0-30                                   1842/f                                          4.89/f                               *(900/f2)                             6
                 30-300                                     61.4                                          0.163                                     1.0                              6
              300-1500                                          /                                              /                                  f/300                              6
          1500-100,000                                          /                                              /                                      5                              6
                                             (B) Limits for General Population/Uncontrolled Exposure
                0.3-1.34                                     614                                           1.63                                  *(100)                             30
                1.34-30                                     824/f                                         2.19/f                               *(180/f2)                            30
                 30-300                                     27.5                                          0.073                                     0.2                             30
              300-1500                                          /                                              /                                 f/1500                             30
          1500-100,000                                          /                                              /                                    1.0                             30
      F=frequency in MHz
      *=Plane-wave equivalent power density
      RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of the FCC rules.
      The emissions should be within the limits at 300kHz in Table 1 of 1.1310(use the 300kHz limits for
      150kHz:614V/m,1.63A/m).
4.1.1             E.U.T. Operation
           Operating Environment:
           Temperature:                        24.0 °C                      Humidity:                52 % RH                         Atmospheric Pressure: 1015 mbar
          EUT Operation:
          This device has been tested the worst status of full load and the device has been tested with mobile
           phone at zero charge, intermediate charge, and full charge.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                             Report No.: SZEM180600493502
                                                                                                                             Page:       8 of 10



4.1.2         Measurement Data


             Output Voltage=DC 9V; The max output power =30W
             Electric Field Emissions
                    Operation                     Test Distance                    Test Position                        Probe Measure                            50% Limit
                    frequency                                                                                            Result (V/m)
                                                           (cm)                                                                                                       (V/m)
                                                                                           Side 1                                   6.86                                307
                                                                                           Side 2                                   6.92                                307
                     149.8 kHz                                15                           Side 3                                   6.88                                307
                                                                                           Side 4                                   6.84                                307
                                                                                             Top                                    6.90                                307


             Magnetic Field Emissions
                    Operation                     Test Distance                    Test Position                        Probe Measure                             50% Limit
                    frequency                                                                                            Result (A/m)
                                                           (cm)                                                                                                       (A/m)
                                                                                           Side 1                                0.0576                                0.815
                                                                                           Side 2                                0.0547                                0.815
                     149.8 kHz                                15                           Side 3                                0.0562                                0.815
                                                                                           Side 4                                0.0572                                0.815
                                                                                             Top                                 0.0634                                0.815




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                             Report No.: SZEM180600493502
                                                                                                                             Page:       9 of 10


             Mobile phone has been charge at zero charge, intermediate charge, and full charge.

             Electric Field Emissions

                 Operation                       Test                                                   Probe Measure Result(V/m)
                                                                               Test                                                                                           50%Limit
                 frequency                     Distance
                                                                           Position                zero                intermediate                       full
                                                                                                  charge                  charge                        charge                    (V/m)
                                                    (cm)
                                                                             Side 1                   6.82                       6.82                       6.83                    307
                                                                             Side 2                   6.97                       6.94                       6.95                    307

                  149.8 kHz                           15                     Side 3                   6.81                       6.87                       6.81                    307
                                                                             Side 4                   6.81                       6.83                       6.86                    307
                                                                                Top                   6.94                       6.98                       6.94                    307


             Magnetic Field Emissions

                 Operation                       Test                                                   Probe Measure Result(A/m)
                                                                               Test                                                                                           50%Limit
                 frequency                     Distance
                                                                           Position               zero                 intermediate                    full
                                                                                                  charge                  charge                       charge                     (A/m)
                                                    (cm)
                                                                             Side 1                0.0573                     0.0573                     0.0573                    0.815
                                                                             Side 2                0.0541                     0.0546                     0.0545                    0.815

                  144.3kHz                            15                     Side 3                0.0565                     0.0564                     0.0567                    0.815
                                                                             Side 4                0.0577                     0.0578                     0.0578                    0.815
                                                                                Top                0.0632                     0.0631                     0.0630                    0.815




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                             Report No.: SZEM180600493502
                                                                                                                             Page:       10 of 10


5          Photographs
           Please refer to RF exposure


                                                                                 - End of the Report -




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only



Document Created: 2018-09-13 07:05:36
Document Modified: 2018-09-13 07:05:36

© 2024 FCC.report