RF Exposure Info

FCC ID: ZBCAC52CMT0

RF Exposure Info

Download: PDF
FCCID_4123144

                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch

No. 1 Workshop, M-10, Middle Section, Science & Technology Park,
Shenzhen, China 518057
Telephone:            +86 (0) 755 2601 2053                                                                                        Report No.: SZEM181000924002
Fax:                  +86 (0) 755 2671 0594
                                                                                                                                   Page:      1 of 9
Email:                ee.shenzhen@sgs.com


1          COVER PAGE

                                           Human Exposure Report
Application No.:           SZEM1810009240CR
Applicant:                 SHENZHEN DNS INDUSTRIES CO., LTD.
Address of Applicant:      23/F Building A, Shenzhen International Innovation Center, No.1006 Shennan
                           Road, Futian, Shenzhen, China
Manufacturer:              SHENZHEN DNS INDUSTRIES CO., LTD.
Address of Manufacturer:   23/F Building A, Shenzhen International Innovation Center, No.1006 Shennan
                           Road, Futian, Shenzhen, China
Factory:                   HUIZHOU D&S CABLE CO., LTD.
Address of Factory:        Longjin Dongjiang Industry Zone Shuikou, Huicheng, Huizhou, Guangdong,
                           China
Equipment Under Test (EUT):
EUT Name:                  Wireless Charger
Model No.:                 AC52CMT0, AC51CMT0 ♣
♣                          Please refer to section 3.2 of this report which indicates which model was
                           actually tested and which were electrically identical.
Trade mark:                DNS, Omars, Novoo, mbest
FCC ID:                    ZBCAC52CMT0
Standards:                 47 CFR PART 1, Subpart I, Section 1.1310
Date of Receipt:           2018-10-25
Date of Test:              2018-10-26 to 2018-11-02
Date of Issue:             2018-11-08
Test Result :               Pass*
* In the configuration tested, the EUT complied with the standards specified above




                   Keny Xu
             EMC Laboratory Manager
The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report.
If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new
system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS
International Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by SGS
International Electrical Approvals in writing.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights
and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification
of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the
sample(s) tested and such sample(s) are retained for 30 days only.


                           SGS—CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                Report No.: SZEM1e1000322002
                                                Page:       2ot8


2      Contents


1.     covenprce
2      contents
a   eenena. inronmation,




                                                                               ho kassus 6
 31. DemuserEUt
 32— DesernonarserontUners
 33. Testiocmnon
 34. Tesrraoume
 35 DevmonrronStmonos
 36— AcvormtaumesrronStfomroCovomons
a ecupients useo puric tes
s      test nesults




                                                                               4 Lo s 6
     51 RfExrowserest
       §.1.1 EULT. Operation
       5.12 MeasurementData:
s      photochapis


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                             Report No.: SZEM181000924002
                                                                                                                             Page:       3 of 9




3          General Information
3.1 Details of E.U.T.
           Power supply:                                      Input: DC 5V/2A, DC 9V/2A
                                                              Output: DC 5V/1A, DC 9V/1.1A(10W Max.)
           Operation frequency:                               107.05-201.94kHz
           Modulation type:                                   Load modulation
           Antenna type:                                      Inductive Loop Coil Antenna
           Remark:                                            Tests were conducted in both load modes and the worst case(10W) is
                                                              reported only.



3.2 Description of Support Units
             Description                                            Manufacturer                                          Model No.                                         Serial No.
                                                                      provided by
             AC/DC adapter                                                                                                    CD122                                             20839
                                                                  client(UGREEN)
             E-loading                                           provided by client                                              N/A                                             10W
             E-loading                                           provided by client                                              N/A                                               5W
             Micro USB Cable                                             PHILIPS                                          SWR2101                                   REF. No.SEA0700
             Mobile Phone
                                                                       SAMSUNG                                            SM-G9500                                      R28J9140LPB
             (for RE tests only)



           Remark:

           Model No.: AC52CMT0, AC51CMT0

           Only the model AC52CMT0 was tested fully, and the model AC51CMT0 was performed the
           Electrostatic Discharge for discrepancy, since the electrical circuit design, PCB layout, components
           used and internal wiring were identical for the above models, with only difference on enclosure shape,
           model name for the marketing requirement.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                             Report No.: SZEM181000924002
                                                                                                                             Page:       4 of 9



3.3 Test Location
             All tests were performed at:
             SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch E&E Lab,
             No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong,China
             518057.
             Tel: +86 755 2601 2053                                  Fax: +86 755 2671 0594
             No tests were sub-contracted.

3.4 Test Facility
           The test facility is recognized, certified, or accredited by the following organizations:
           • CNAS (No. CNAS L2929)
           CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
           Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
           Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
           Laboratories) for the competence in the field of testing.
           • A2LA (Certificate No. 3816.01)
           SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
           American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
           • VCCI
           The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
           Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
           Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
           been registered in accordance with the Regulations for Voluntary Control Measures with Registration
           No.: G-20026, R-14188, C-12383 and T-11153 respectively.
           • FCC –Designation Number: CN1178
           SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
           as an accredited testing laboratory.
           Designation Number: CN1178. Test Firm Registration Number: 406779.
           • Innovation, Science and Economic Development Canada
           SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
           by ISED as an accredited testing laboratory.
           CAB identifier: CN0006.
           IC#: 4620C.

3.5 Deviation from Standards
           None.

3.6 Abnormalities from Standard Conditions
           None.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                             Report No.: SZEM181000924002
                                                                                                                             Page:       5 of 9


4          Equipments Used during Test

                                                                                                                                          Inventory                Cal. Due date
             Item               Test Equipment                             Manufacturer                        Model No.
                                                                                                                                             No.                     (yyyy-mm-dd)

                1                Shielding Room                                  SAEMC                           MSR733                 SEM001-09                       2020-05-09

                                   Electric and
                2                 Magnetic Field                                   Narda                        EHP-50F                    EMC092                      2019-02-06
                                    Analyzer




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                             Report No.: SZEM181000924002
                                                                                                                             Page:       6 of 9



5          Test Results
5.1 RF Exposure test
           Test Requirement:                                        47 CFR PART 1, Subpart I, Section 1.1310
           Measurement Distance:                                    15cm
           Limit:

      Frequency range Electric field strength Magnetic field strength Power density Averaging time
           (MHz)               (V/m)                  (A/m)             (mW/cm2)      (minutes)
                                                    (A) Limits for Occupational/Controlled Exposures
                 0.3-3.0                                     614                                           1.63                                  *(100)                              6
                 3.0-30                                   1842/f                                          4.89/f                               *(900/f2)                             6
                 30-300                                     61.4                                          0.163                                     1.0                              6
              300-1500                                          /                                              /                                  f/300                              6
          1500-100,000                                          /                                              /                                      5                              6
                                             (B) Limits for General Population/Uncontrolled Exposure
                0.3-1.34                                     614                                           1.63                                  *(100)                             30
                1.34-30                                     824/f                                         2.19/f                               *(180/f2)                            30
                 30-300                                     27.5                                          0.073                                     0.2                             30
              300-1500                                          /                                              /                                 f/1500                             30
          1500-100,000                                          /                                              /                                    1.0                             30
      F=frequency in MHz
      *=Plane-wave equivalent power density
      RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of the FCC rules.
      The emissions should be within the limits at 300kHz in Table 1 of 1.1310(use the 300kHz limits for
      150kHz:614V/m,1.63A/m).
5.1.1         E.U.T. Operation

          Operating Environment:
          Temperature:      24.5 °C                                         Humidity:                52 % RH                         Atmospheric Pressure: 1015 mbar

          EUT Operation:
          This device has been tested the worst status of full load and the device has been tested with mobile
           phone at zero charge, intermediate charge, and full charge.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                             Report No.: SZEM181000924002
                                                                                                                             Page:       7 of 9



5.1.2         Measurement Data


             Output Voltage=DC 9V; The max output power =10W;Calculation of resistor value=8.1Ω
             Electric Field Emissions
                    Operation                     Test Distance                     Test Position                        Probe Measure                            50% Limit
                    frequency                                                                                             Result (V/m)
                                                           (cm)                                                                                                       (V/m)
                                                                                           Side 1                                   1.55                                307
                                                                                           Side 2                                   1.64                                307
                     147.2 kHz                                15                           Side 3                                   1.46                                307
                                                                                           Side 4                                   1.54                                307
                                                                                             Top                                    1.91                                307


             Magnetic Field Emissions
                    Operation                     Test Distance                     Test Position                        Probe Measure                            50% Limit
                    frequency                                                                                             Result (A/m)
                                                           (cm)                                                                                                        (A/m)
                                                                                           Side 1                                0.0220                                0.815
                                                                                           Side 2                                0.0231                                0.815
                     147.2 kHz                                15                           Side 3                                0.0201                                0.815
                                                                                           Side 4                                0.0296                                0.815
                                                                                             Top                                 0.0339                                0.815




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                             Report No.: SZEM181000924002
                                                                                                                             Page:       8 of 9



             Mobile phone has been charge at zero charge, intermediate charge, and full charge.

             Electric Field Emissions

                 Operation                        Test                                                   Probe Measure Result(V/m)
                                                                               Test                                                                                           50%Limit
                 frequency                      Distance
                                                                                                    zero                intermediate                       full
                                                                           Position
                                                                                                   charge                  charge                        charge                   (V/m)
                                                    (cm)
                                                                             Side 1                   1.55                       1.64                       1.43                    307
                                                                             Side 2                   1.64                       1.66                       1.48                    307
                  147.2 kHz                           15                     Side 3                   1.46                       1.38                       1.34                    307
                                                                             Side 4                   1.54                       1.62                       1.49                    307
                                                                                Top                   1.91                       2.02                       1.83                    307


             Magnetic Field Emissions

                 Operation                        Test                                                   Probe Measure Result(A/m)
                                                                               Test                                                                                           50%Limit
                 frequency                      Distance
                                                                                                  zero                  intermediate                   full
                                                                           Position
                                                                                                  charge                   charge                      charge                     (A/m)
                                                    (cm)
                                                                             Side 1                0.0220                     0.0182                     0.0193                    0.815
                                                                             Side 2                0.0231                     0.0196                     0.0188                    0.815
                  147.2 kHz                           15                     Side 3                0.0201                     0.0192                     0.0175                    0.815
                                                                             Side 4                0.0296                     0.0286                     0.0277                    0.815
                                                                                Top                0.0339                     0.0304                     0.0297                    0.815




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                             Report No.: SZEM181000924002
                                                                                                                             Page:       9 of 9


6          Photographs
           Please refer to RF Exposure setup photos.




                                                                                 - End of the Report -




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only



Document Created: 2018-12-26 03:07:33