RF Exposure Info

FCC ID: Z9G-EDF89

RF Exposure Info

Download: PDF
FCCID_4405324

                                   SGS-CSTC Standards Technical Services Co., Ltd.
                                   Shenzhen Branch




                                                                          Report No.: SZEM190601498203
                                                                          Page:        1 of 7
1    Cover page


                       SAR Evaluation Report
Application No.:                 SZEM1906014982CR
Applicant:                       Edifier International Limited
Address of Applicant:            P.O. Box 6264 General Post Office Hong Kong
Manufacturer:                    Beijing Edifier Technology Co., Ltd.
Address of Manufacturer:         8th floor, ZuoAn Building, NO.68 BeiSiHuanXiLu, Haidian District, Beijing
                                 100080, CHINA
Factory:                         Dongguan Edifier Technology Co., Ltd.
Address of Factory:              No.2 Gongyedong Road, Songshan Lake Sci&Tech Industry Park, Dongguan,
                                 Guangdong 523808, PR.China
Equipment Under Test (EUT):
EUT Name:                        True Wireless Earbuds with Balanced Armature Drivers
Model No.:                       TWS BA1, Ebuds3         ♣
♣                                Please refer to section 2 of this report which indicates which model was
                                 actually tested and which were electrically identical.
Trade mark:                      EDIFIER
FCC ID:                          Z9G-EDF89
Standards:                       47 CFR Part 1.1307
                                 47 CFR Part 2.1093
                                 KDB447498D01 General RF Exposure Guidance v06
Date of Receipt:                 2019-06-11
Date of Test:                    2019-06-12 to 2019-07-15
Date of Issue:                   2019-07-17
Test Result :                      PASS*

*   In the configuration tested, the EUT complied with the standards specified above.




            Keny Xu
      EMC Laboratory Manager


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                               Report No.: SZEM190601498203
                                                               Page:       2 of 7


2    Version


                                             Revision Record

         Version       Chapter               Date                  Modifier       Remark

         01                               2019-07-17                              Original




    Authorized for issue by:




                                  Harry Wu /Project Engineer




                                  Eric Fu /Reviewer


                                                SGS-CSTC Standards Technical Services Co., Ltd.
                                                Shenzhen Branch
                                                                                                      Report No.: SZEM190601498203
                                                                                                      Page:       3 of 7


3         Contents
                                                                                                                                                               Page
1       COVER PAGE .............................................................................................................................................. 1
2       VERSION ...................................................................................................................................................... 2
3       CONTENTS .................................................................................................................................................. 3
4       GENERAL INFORMATION .......................................................................................................................... 4
    4.1         GENERAL DESCRIPTION OF EUT ............................................................................................................. 4
    4.2         TEST LOCATION...................................................................................................................................... 5
    4.3         TEST FACILITY........................................................................................................................................ 5
    4.4         DEVIATION FROM STANDARDS ................................................................................................................. 6
    4.5         ABNORMALITIES FROM STANDARD CONDITIONS ....................................................................................... 6
    4.6         OTHER INFORMATION REQUESTED BY THE CUSTOMER ............................................................................. 6
5       SAR EVALUATION ...................................................................................................................................... 7
    5.1     RF EXPOSURE COMPLIANCE REQUIREMENT ............................................................................................ 7
       5.1.1 Standard Requirement ..................................................................................................................... 7
       5.1.2 Limits ................................................................................................................................................ 7
       5.1.3 EUT RF Exposure ............................................................................................................................ 7


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                                  Report No.: SZEM190601498203
                                                                  Page:       4 of 7


4    General Information
4.1 General Description of EUT
    Power supply:              Ear Phone: DC3.7V Rechargeable Battery
                               Charge Case: DC 5V,500mA
    Operation Frequency:       2402MHz to 2480MHz
    Bluetooth Version:         V5.0
    Spectrum Spread            Frequency Hopping Spread Spectrum(FHSS)
    Technology:
    Modulation Type:           GFSK, π/4DQPSK, 8DPSK
    Number of Channels:        79
    Channel Spacing:           1MHz
    Antenna Type:              Integral Antenna
    Antenna Gain:              0.7dBi

    Declaration of EUT Family Grouping:

    Model No.: TWS BA1, Ebuds3

    Only the model TWS BA1 was tested, since the electrical circuit design, layout, components used,
    internal wiring and functions were identical for the above models, with only difference on product model.


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                     Report No.: SZEM190601498203
                                                                     Page:       5 of 7


4.2 Test Location
    All tests were performed at:
    SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch
    No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China
    518057
    Telephone: +86 (0) 755 2601 2053 Fax: +86 (0) 755 2671 0594
    No tests were sub-contracted.

4.3 Test Facility
    The test facility is recognized, certified, or accredited by the following organizations:
    • CNAS (No. CNAS L2929)
    CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
    Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
    Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
    Laboratories) for the competence in the field of testing.
    • A2LA (Certificate No. 3816.01)
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
    American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
    • VCCI
    The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
    Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
    Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
    been registered in accordance with the Regulations for Voluntary Control Measures with Registration
    No.: G-20026, R-14188, C-12383 and T-11153 respectively.
    • FCC –Designation Number: CN1178
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    as an accredited testing laboratory.
    Designation Number: CN1178. Test Firm Registration Number: 406779.
    • Innovation, Science and Economic Development Canada
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    by ISED as an accredited testing laboratory.
    CAB identifier: CN0006.
    IC#: 4620C.


                   SGS-CSTC Standards Technical Services Co., Ltd.
                   Shenzhen Branch
                                             Report No.: SZEM190601498203
                                             Page:       6 of 7


4.4 Deviation from Standards
   None.

4.5 Abnormalities from Standard Conditions
   None.

4.6 Other Information Requested by the Customer
   None.


                                   SGS-CSTC Standards Technical Services Co., Ltd.
                                   Shenzhen Branch
                                                                                     Report No.: SZEM190601498203
                                                                                     Page:       7 of 7


5    SAR Evaluation
5.1 RF Exposure Compliance Requirement
5.1.1 Standard Requirement
    According to KDB447498D01 General RF Exposure Guidance v06
    4.3.1. Standalone SAR test exclusion considerations
           Unless specifically required by the published RF exposure KDB procedures, standalone 1-g
    head or body and 10-g extremity SAR evaluation for general population exposure conditions, by
    measurement or numerical simulation, is not required when the corresponding SAR Exclusion
    Threshold condition, listed below, is satisfied.
5.1.2 Limits
    The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
    ≤ 50 mm are determined by:

    [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·
    [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where

     f(GHz) is the RF channel transmit frequency in GHz
     Power and distance are rounded to the nearest mW and mm before calculation17
     The result is rounded to one decimal place for comparison
    The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and
    for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation
    distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion
5.1.3 EUT RF Exposure


      The Max. power (including tune-up tolerance) is 8.31 dBm on the lowest channel                   2.441   GHz (*)
      8.31 dBm logarithmic terms convert to numeric result is nearly 6.78 mW
      According to the formula. calculate the test exclusion thresholds:
                              .         ,              ,    ∗   
      General RF Exposure 
                                              .  ! !    !    ,
      General RF Exposure = (6.78 mW / 5 mm) x √2.441 GHz = 2.12                                       (1)
      SAR requirement:
      S = 3.0                                                                                          (2)
      (1) < (2)
      So the SAR report is not required.

      (*) Max. power refer to Report No.:SZEM190601498202

                                                   - End of the Report -



Document Created: 2019-08-14 06:34:08