RF exposure info

FCC ID: Z9G-EDF75

RF Exposure Info

Download: PDF
FCCID_4497340

1 Safety Human Exposure
1.1 Radio Frequency Exposure Compliance
1.1.1 Electromagnetic Fields
RESULT:                                                                                          Pass

Test Specification
Test standard                                   :   CFR47 FCC Part 2: Section 2.1091
                                                    CFR47 FCC Part 1: Section 1.1310
                                                    FCC KDB Publication 447498 v06
                                                    FCC KDB Publication 865664 D02 v01r02
                                                    OET Bulletin 65 (Edition 97-01)
                                                    RSS-102 Issue 5 March 2015


FCC ID: Z9G-EDF65
IC: 1004A-EDF65

 FCC requirements
FCC requirement: Systems operating under the provisions of this section shall be operat ed in a manner
that ensures that the public is not exposed to radio frequency energy level in excess limit for maximum
permissible exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 t his devic e has
been defined as a mobile device whereby a distance of 20cm normally can be maintained between the user
and the device.


MPE Calculation Method according to OET Bulletin 65
Power Density: S (mW/cm2)= PG/4πR2 or EIRP/4πR2


Where:
S = power density (mW/cm 2)
P = power input to the antenna (mW)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator
R = distance to the center of radiation of the antenna (cm)


The nominal maximum conducted output power specified:
2.4GHz FHSS: 0.34 dBm
5.8GHz: 3.60 dBm


From the peak RF output power, the minimum mobile separation distance, d=20 cm, as well as the antenna
gain (Max. 2.5 dBi for 2.4GHz FHSS and 1.5 dBi 5.8GHz), the RF power density can be calculated as
below:


For 2.4GHz FHSS: S(mW/cm2)= PG/4πR2 = 0.0004 mW/cm2
For 5.8GHz: S(mW/cm2)= PG/4πR2 = 0.001 mW/cm2


Limits for Maximum Permissible Exposure (MPE) according to FCC Part 1.1310:
1.0 mW/cm2


For Simultaneous transmitting of 2.4GHz FHSS and 5.8GHz:
According to 865664D02 2.2 d) 1):


The sum of the ratios of the spatially averaged results to the applicable frequency dependent MPE limits =
0.0003/1 + 0.004/1 = 0.0043 < 1


 IC requirements: The EUT shall comply with the requirement of RSS-102 section 2.5.2.


Exemption from Routine Evaluation Limits – RF Exposure Evaluation
RF exposure evaluation is required if the separation distance between the user and/or bystander and the
device’s radiating element is greater than 20 cm, except when the device operates as follows:

at or above 300 MHz and below 6 GHz and the source-based, time-averaged maximum e.i.r.p. of the
device is equal to or less than 1.31 x 10-2 ƒ0.6834 W (adjusted for tune-up tolerance), where ƒ is in MHz;
     RF exposure evaluation exempted power for 2.4GHz FHSS: 2.676 W
       RF exposure evaluation exempted power for 5.8GHz: 4.849 W


The nominal maximum conducted output power specified:


2.4GHz FHSS: 0.34 dBm
5.8GHz: 3.60 dBm


Antenna Gain: 2.5 dBi for 2.4GHz FHSS
Antenna Gain: 1.5 dBi for 5.8GHz


The Max. e.i.r.p. for 2.4GHz FHSS: 2.84 dBm = 0.002 W
The Max. e.i.r.p. for 5.8GHz: 5.10 dBm = 0.003 W


For Simultaneous transmitting of 2.4GHz FHSS and 5.8GHz:
According to 865664D02 2.2 d) 1):
The sum of the ratios of the spatially averaged results to the applicable frequency dependent MPE limits =
0.001/2.676 + 0.019/4.849 = 0.0043 < 1

Both e.i.r.p. for the 2.4GHz FHSS and 5.8GHz are less than the RF exposure evaluation exempted power.
So RF exposure evaluation is not required.



“RF Radiation Exposure Statement Caution: This Transmitter must be installed to provide a
separation distance of at least 20 cm from all persons.”



Document Created: 2019-07-31 17:18:20