RF Exposure

FCC ID: Z9G-EDF52

RF Exposure Info

Download: PDF
FCCID_3438626

                RF Exposure evaluation

According to 447498   D01 General RF Exposure Guidance

v05

The 1-g and 10-g SAR test exclusion thresholds for

100 MHz to 6 GHz at test separation distances ≤ 50

mm are determined by:

[(max. power of channel, including tune-up tolerance,

mW)/(min. test separation distance, mm)] ·[√f(GHz)]

≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,

where

  f(GHz) is the RF channel transmit frequency in GHz

  Power and distance are rounded to the nearest mW

and mm before calculation

  The result is rounded to one decimal place for

comparison

Worse case is as below: [2480MHz   9.060 dBm(8.05mW)

output power]

(8.05mW /5 mm) ·[√2.480 (GHz)]= 2.5 <3 for 1-g SAR

Then SAR evaluation is not required



Document Created: 2017-06-25 13:00:20
Document Modified: 2017-06-25 13:00:20

© 2024 FCC.report