RF Exposure

FCC ID: Z9G-EDF48

RF Exposure Info

Download: PDF
FCCID_3367340

                            RF Exposure evaluation

According to KDB 447498 D01 General RF Exposure Guidance v05
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test
separation distances ≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation
distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,
where
    f(GHz) is the RF channel transmit frequency in GHz
    Power and distance are rounded to the nearest mW and mm before
calculation
    The result is rounded to one decimal place for comparison


Worse case is as below: [2480MHz      3.39dBm(2.183mW)output power]


(2.183 mW /5mm) ·[√2.480 (GHz)]= 0.69 <3.0 for 1-g SAR

Then SAR evaluation is not required