User Manual

FCC ID: Z8H89FT0044

Users Manual

Download: PDF

@ Cambium Networks®
                                                 Introduction                                                         STEP 1 (Pole Mount)                                          STEP 2 (Pole Mount)                                                     STEP 3 (Pole Mount)


cnRanger | Tyndall 101                           This guide provides quick installation steps for cnRanger
                                                 Tyndall 101 Subscriber Module (SM).

LTE 14dBi Subscriber Module                      Package Contents


Quick Start Guide

                                                   Pole mounting bracket       Po Infector




                                                                                                     Tyndall 101 8M

                                                       Hose clmp              Power Cord =*
                                                       (aty. 2
                                    HHHHIH   :
                                        i


                                                   Mi2x 60 Bole                 MIZ Nut & Wesher


                                                 Tools Required
   cnMaestro                                     + Flat head scrowdriver   (Pole Mounting)                            Assemble the radio to the pole mounting bracket.             Secure pole mounting bracket with MB nut and bolt by applying           Insert hose clamps through pole mounting bracket and

        READY                       4            * 12 mm wrench            (Pole Mounting)                                                                                         3.0 Nm torque.                                                          clamp to pole by applying 3.0 Nm torque.
                                                 ** SKU "2LTE—SM—404" does not contain Power cord.




                                                 STEP 4                                                               STEP 5 (Pole Mount)                                          Powering Up                                                             Configure Management PC
                                                                                                                      4                                                            A1.   Connect the Ethernet cable from Eth1/PoE—IN of cnRanger Tynall      1.   Select Propartias for the Ethernat port.
                                                                                                                                                                                         101 to the PoE port of Gigabit Data + Power                              * In Windows,it is found in Control Panel > Network and Internat >
                                                                                                                                                                                         Connect an Ethernet cable from your LAN or Computer to the




                                                                                                                                                                                     P
                                                                                                                                                                                                                                                                  Network Connections > Local Area Connection.
                                                                                                                                                                                         Gigabit Data port of the PoE adapter.                                    + In MAC, it is found in System Preferences > Network,
                                                                                                                                                                                                                                                                  + In Linux, It‘s found In System Settings > Network > Wired > Options

                                                                                                                                                                                                                                                             2.   IP Address configuration to use the static Tyndall factory default
                                                                                                                                                                                                                                                                  eddress:
                                                                                                                                                                                                                                                                  a.. Assign a static address on the 169,254.0.0/16 subnet other
       ( Cambium Networks                                                                                                                                                                                                                                               than 169,254.1., It is recommended to use 169.254.1.3.
              Community Forum                                                                                                                                                                                                                                     b. Assign a subnet mask of 255.255.0.0
                                                                                                                                                                                                                                                                  c.    Leave the default gateway blank
                                                                                                                                                                                         Connect the Power Cord to the adapter, and then plug the Power




                                                                                                                                                                                     F
                                                                                                                                                                                                                                                                  — IP address configuration using dynamically assigned address:
                                                                                                                                                                                         Cord Into a power outlet.




                                                                                                                                                                                                  B.
                                                                                                                                                                                                                                                                       in this case, the management PC is configured to automatically detect
                                                                                                                                                                                                                                                                       the network configuration (e, DHCP),
                                                                                                                                                                                                                                                                       Once the network configuration is detected, use the web browser to
                                                                                                                                                                                                                                                                       navigate to the discovered default gateway IP addrass and login using
                                                                                                                                                                                                                                                                       the following credentials
                                                                                                                                                                                                                                                                        * Username: admin
                                                                                                                                                                                                                                                                        * Password: admin
    JOIN THE CONVERSATION                                                                                              Align radio to required angle by tilting up and down. The
                                                                                                                                                                                         Once powered ON — Power LED should illuminate continuously on
                                                                                                                                                                                         PoE Adapter.
    community.cambiumnetworks.com                Remove cap and connect RJ 45 cable to the radio.                      maximum radio tilting angle is + 40°, with an incremental         **shielded Categary 5 (or above) cabling should be used for all
                                                                                                                       of 10®. Secure radio with max 5.0 Nm torque.                      outdboor wired Ethernet connections andshould be grounded
                                                                                                                                                                                         through the AC ground ofthe PoE.


43



Document Created: 2019-07-09 18:16:06
Document Modified: 2019-07-09 18:16:06

© 2019 FCC.report