WHFCC RADIO EXPOSURE TEST REPORT                                                       Report No. : FA891915—03


                                                                                                 o ow
                                                                                                 ’z,//;“\\}‘    ‘eting Latertony
                                                                                                  "alubuie®          1190



     FCC RADIO EXPOSURE TEST REPORT

         FCC ID                  : Z8H89FTO044
         Equipment               : 2 GHz Tyndall 101
         Brand Name              : Cambium Networks
         Model Name              : 2 GHz Tyndall 101
         Applicant               : Cambium Networks Inc.
                                   3800 Golf Road, Suite 360 Rolling Meadows, IL 60008, USA
         Manufacturer            : Cambium Networks Inc.
                                   3800 Golf Road, Suite 360 Rolling Meadows, IL 60008, USA
         Standard                : 47 CFR Part 21091

  The product was received on Sep. 12, 2018, and testing was started from Sep. 12, 2018 and
  completed on Sep. 17, 2018. We, SPORTON INTERNATIONAL INC. EMC & Wireless Communications
  Laboratory, would like to declare that the tested sample has been evaluated in accordance with the
  procedures given in 47 CFR Part 21091 and shown compliance with the applicable technical
  standards.

  The report must not be used by the client to claim product certification, approval, or endorsement by
  TAF or any agency of government.

  The test results in this report apply exclusively to the tested model / sample. Without written
  approval of SPORTON INTERNATIONAL INC. EMC & Wireless Communications Laboratory, the test
  report shall not be reproduced except in full.




                   ([eills [CP
                       Approved by: Cliff fy‘g

         SPORTON INTERNATIONAL INC. EMC & Wireless Communications Laboratory
                            No. 52, Huaya 1st Rd., Guishan Dist., Taoyuan City, Taiwan (R.O.C.)




TEL : 886—3—656—9065                                                            Page Number       : 1 of 7
FAX : 886—3—656—9085                                                            Issued Date       : Jun. 17, 2019
Report Template No.: CB Ver1.0                                                  Report Version    : 02


               FCC RADIO EXPOSURE TEST REPORT                                                                              Report No. : FA891915-03




                                                            Table of Contents
History of this test report.................................................................................................................................3
Summary of Test Result...................................................................................................................................4
1      General Description .............................................................................................................................5
1.1    EUT General Information .......................................................................................................................5
1.2    Testing Location .....................................................................................................................................5
2      RF Exposure Limit Introduction..........................................................................................................6
2.1    MPE Calculation Method........................................................................................................................6
3      Radio Frequency Radiation Exposure Evaluation ............................................................................7
3.1    Power Density Calculation .....................................................................................................................7
Photographs of EUT v01




TEL : 886-3-656-9065                                                                                              Page Number          : 2 of 7
FAX : 886-3-656-9085                                                                                              Issued Date          : Jun. 17, 2019
Report Template No.: CB Ver1.0                                                                                    Report Version       : 02


            FCC RADIO EXPOSURE TEST REPORT                                   Report No. : FA891915-03




                                 History of this test report

   Report No.          Version                 Description                                 Issued Date

 FA891915-03              01               Initial issue of report                        May 09, 2019

 FA891915-03              02          Revising FCC ID “Z8H89FT0044”                       Jun. 17, 2019




TEL : 886-3-656-9065                                                  Page Number      : 3 of 7
FAX : 886-3-656-9085                                                  Issued Date      : Jun. 17, 2019
Report Template No.: CB Ver1.0                                        Report Version   : 02


            FCC RADIO EXPOSURE TEST REPORT                                           Report No. : FA891915-03




                                       Summary of Test Result

  Report       Ref Std.                                                       Result
                                             Test Items                                               Remark
  Clause        Clause                                                    (PASS/FAIL)

     3              -        Exposure evaluation                              PASS             -



Declaration of Conformity:
The test results with all measurement uncertainty excluded are presented in accordance with the regulation limits
or requirements declared by manufacturers.
Comments and Explanations:
The declared of product specification for EUT presented in the report are provided by the manufacturer, and
the manufacturer takes all the responsibilities for the accuracy of product specification.
Reviewed by: Sam Chen
Report Producer: Viola Huang




TEL : 886-3-656-9065                                                          Page Number      : 4 of 7
FAX : 886-3-656-9085                                                          Issued Date      : Jun. 17, 2019
Report Template No.: CB Ver1.0                                                Report Version   : 02


            FCC RADIO EXPOSURE TEST REPORT                                                Report No. : FA891915-03




1         General Description
1.1       EUT General Information
                                              RF General Information
Evaluation Mode TX Frequency (MHz)                    RX Frequency (MHz)           Modulation Type
                        5 MHz: 2498.5 ~ 2687.5         5 MHz: 2498.5 ~ 2687.5
                        10 MHz: 2501 ~ 2685            10 MHz: 2501 ~ 2685
 LTE Band 41                                                                        QPSK / 16QAM / 64QAM
                        15 MHz: 2503.5 ~ 2682.5        15 MHz: 2503.5 ~ 2682.5
                        20 MHz: 2506 ~ 2680            20 MHz: 2506 ~ 2680

1.2         Testing Location
                                                  Testing Location
      HWA YA        ADD     :    No. 52, Hwa Ya 1st Rd., Kwei-Shan Hsiang, Tao Yuan Hsien, Taiwan, R.O.C.
                    TEL     :    886-3-327-3456        FAX    :   886-3-327-0973
      JHUBEI        ADD     :    No.8, Lane 724, Bo-ai St., Jhubei City, HsinChu County 302, Taiwan, R.O.C.
                    TEL     :    886-3-656-9065        FAX    :   886-3-656-9085
Test site Designation No. TW0006 with FCC.
Test site registered number IC 4086B with Industry Canada.




TEL : 886-3-656-9065                                                               Page Number      : 5 of 7
FAX : 886-3-656-9085                                                               Issued Date      : Jun. 17, 2019
Report Template No.: CB Ver1.0                                                     Report Version   : 02


            FCC RADIO EXPOSURE TEST REPORT                                                    Report No. : FA891915-03




2         RF Exposure Limit Introduction
(A) Limits for Occupational / Controlled Exposure
                                                                                                        Averaging Time
  Frequency Range            Electric Field       Magnetic Field        Power Density (S)
                                                                                                         |E|²,|H|² or S
       (MHz)               Strength (E) (V/m)   Strength (H) (A/m)         (mW/ cm²)
                                                                                                           (minutes)
         0.3-3.0                   614                 1.63                     (100)*                           6
         3.0-30                  1842 / f             4.89 / f                 (900 / f)*                        6
         30-300                   61.4                0.163                       1.0                            6
       300-1500                                                                 F/300                            6
     1500-100,000                                                                  5                             6
(B) Limits for General Population / Uncontrolled Exposure
                                                                                                     Averaging Time
 Frequency Range             Electric Field       Magnetic Field        Power Density (S)
                                                                                                      |E|²,|H|² or S
      (MHz)                Strength (E) (V/m)   Strength (H) (A/m)         (mW/ cm²)
                                                                                                        (minutes)
        0.3-1.34                  614                  1.63                     (100)*                           30
        1.34-30                   824/f               2.19/f                   (180/f)*                          30
        30-300                    27.5                0.073                      0.2                             30
       300-1500                                                                F/1500                            30
    1500-100,000                                                                 1.0                             30
Note: f = frequency in MHz ; *Plane-wave equivalent power density

2.1       MPE Calculation Method
The MPE was calculated at 43 cm to show compliance with the power density limit.
The following formula was used to calculate the Power Density:


               30  P  G                                                      E2
E (V/m) =                                   Power Density:       Pd (W/m²) =
                   d                                                           377
E = Electric field (V/m)
P = RF output power (W)
G = EUT Antenna numeric gain (numeric)
d = Separation distance between radiator and human body (m)
The formula can be changed to

Pd =
        30  P  G
         377  d 2


TEL : 886-3-656-9065                                                                   Page Number        : 6 of 7
FAX : 886-3-656-9085                                                                   Issued Date        : Jun. 17, 2019
Report Template No.: CB Ver1.0                                                         Report Version     : 02


            FCC RADIO EXPOSURE TEST REPORT                                                   Report No. : FA891915-03




3         Radio Frequency Radiation Exposure Evaluation
3.1       Power Density Calculation
                                                                  Tune-up   Tune-up
                             DG     Power      EIRP   Tolerance                        Distance    S      S Limit
         Mode                                                       EIRP     EIRP                     2          2
                            (dBi)   (dBm)     (dBm)      (dB)                            (cm)   (mW/cm ) (mW/cm )
                                                                   (dBm)      (W)
 Band 41_LTE_20MHz_
                             14     29.05     43.05      0.5       43.55    22.646         43       0.97464       1.00000
       (16QAM)

Note: The above information was declared by manufacturer.
Conclusion:
According to 47 CFR Part 2.1091, the RF exposure analysis concludes that the RF Exposure is compliant.




                                            ─────THE END─────
TEL : 886-3-656-9065                                                                  Page Number      : 7 of 7
FAX : 886-3-656-9085                                                                  Issued Date      : Jun. 17, 2019
Report Template No.: CB Ver1.0                                                        Report Version   : 02



Document Created: 2019-07-09 18:48:49
Document Modified: 2019-07-09 18:48:49

© 2019 FCC.report
This site is not affiliated with or endorsed by the FCC