RF Exposure Info (MPE).pdf

FCC ID: Z3M-ZBMOD1

RF Exposure Info

Download: PDF
FCCID_2169458

                                     RF EXPOSURE REPORT


                                         REPORT NO.: SA130927E08B

                                          MODEL NO.: FiOS-ZBMod1

                                                    FCC ID: Z3M-ZBMOD1

                                             RECEIVED: Oct. 11, 2013
                                                  TESTED: Oct. 31, 2013
                                                   ISSUED: Dec. 23, 2013


                                           APPLICANT: Greenwave Reality Pte Ltd

                                              ADDRESS: 41 Science Park Road, #03-01, The
                                                       Gemini, Science Park II, Singapore,
                                                       117610 Singapore



                                             ISSUED BY: Bureau Veritas Consumer Products Services
                                                        (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory

                                     LAB ADDRESS: No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen,
                                                  Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan,
                                                  R.O.C.

  This report should not be used by the client to claim
  product certification, approval, or endorsement by any
  government agencies.




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is
permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set
forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or
identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the
information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our
negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue
within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the
report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or
non-compliance to the specification

 Report No.: SA130927E08B                                               1 of 6                                             Report Format Version 5.0.0
 Reference No.: 131011E10


                                  TABLE OF CONTENTS
RELEASE CONTROL RECORD .................................................................................... 3
1.   CERTIFICATION ...................................................................................................... 4
2.   RF EXPOSURE LIMIT.............................................................................................. 5
3.   MPE CALCULATION FORMULA ............................................................................. 5
4.   CLASSIFICATION .................................................................................................... 5
5.   CALCULATION RESULT OF MAXIMUM CONDUCTED POWER ........................... 6




Report No.: SA130927E08B                              2 of 6                                   Report Format Version 5.0.0
Reference No.: 131011E10


                             RELEASE CONTROL RECORD

 ISSUE NO.                 REASON FOR CHANGE             DATE ISSUED
 SA130927E08B              Original release              Dec. 23, 2013




Report No.: SA130927E08B                      3 of 6   Report Format Version 5.0.0
Reference No.: 131011E10


1. CERTIFICATION

               PRODUCT:         Zigbee Wireless Module

         BRAND NAME:            GreenWave Reality

             MODEL NO.:         FiOS-ZBMod1

         TEST SAMPLE:           ENGINEERING SAMPLE

            APPLICANT:          Greenwave Reality Pte Ltd

        TESTED DATE:            Oct. 31, 2013

           STANDARDS:           FCC Part 2 (Section 2.1091)

                                FCC OET Bulletin 65, Supplement C (01-01)

                                IEEE C95.1


The above equipment (Model: FiOS-ZBMod1) has been tested by Bureau Veritas
Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance
with the requirement of the above standards. The test record, data evaluation &
Equipment Under Test (EUT) configurations represented herein are true and accurate
accounts of the measurements of the sample’s EMC characteristics under the
conditions specified in this report.




 PREPARED BY               :                                 ,   DATE:   July 24, 2012
                               ( Midoli Peng, Specialist )


 APPROVED BY               :                                 ,   DATE:   July 24, 2012
                                ( May Chen, Manager )




Report No.: SA130927E08B                       4 of 6                     Report Format Version 5.0.0
Reference No.: 131011E10


2. RF EXPOSURE LIMIT

LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
   FREQUENCY               ELECTRIC FIELD MAGNETIC FIELD POWER DENSITY    AVERAGE TIME
   RANGE (MHz)             STRENGTH (V/m) STRENGTH (A/m)   (mW/cm2)         (minutes)
                 LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE
      300-1500                  …                …          F/1500                30
   1500-100,000                 …                …            1.0                 30

F = Frequency in MHz


3. MPE CALCULATION FORMULA
Pd = (Pout*G) / (4*pi*r2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
pi = 3.1416
r = distance between observation point and center of the radiator in cm


4. CLASSIFICATION
The antenna of this product, under normal use condition, is at least 20cm away from the
body of the user. So, this device is classified as Mobile Device.




Report No.: SA130927E08B                     5 of 6                  Report Format Version 5.0.0
Reference No.: 131011E10


5. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER

 FREQUENCY          CONDUCTED        ANTENNA                      POWER
                                                      DISTANCE                       LIMIT
    BAND              POWER            GAIN                       DENSITY
                                                         (cm)                      (mW/cm2)
    (MHz)              (mW)            (dBi)                     (mW/ cm2)
  2405 - 2480              106.170     3.5               20       0.04729             1.00




 --- END ---




Report No.: SA130927E08B                     6 of 6                     Report Format Version 5.0.0
Reference No.: 131011E10



Document Created: 2013-12-23 11:31:13
Document Modified: 2013-12-23 11:31:13

© 2024 FCC.report