Test Report

FCC ID: Z23012A

Test Report

Download: PDF
FCCID_4064342

                                                               SGS-CSTC Standards Technical Services Co., Ltd.
                                                               Shenzhen Branch

No. 1 Workshop, M-10, Middle section, Science & Technology Park,
Shenzhen, Guangdong, China 518057
Telephone:            +86 (0) 755 2601 2053                                                                                       Report No.: SZEM180300231601
Fax:                  +86 (0) 755 2671 0594
                                                                                                                                  Page:        1 of 14
Email:                ee.shenzhen@sgs.com




                                                                    TEST REPORT
Application No.:                                            SZEM1803002316CR
Applicant:                                                  Teenage Engineering AB
Address of Applicant:                                       Virkesvagen 3A, Stockholm, 12030, Sweden
Manufacturer:                                               Teenage Engineering AB
Address of Manufacturer:                                    Virkesvagen 3A, Stockholm, 12030, Sweden
Factory:                                                    S&O Electronics (M) Sdn. Bhd.
Address of Factory:                                         Lot 202, Bakar Arang Industrial Estate, 08000 Sungai Petani, Kedah, West
                                                            Malaysia
Equipment Under Test (EUT):
EUT Name:                                                   Portable Musical Instrument
Model No.:                                                  TE012AS001
Trade mark:                                                 OP-Z
FCC ID:                                                     Z23012A
Standard(s) :                                               47 CFR Part 15, Subpart B
Date of Receipt:                                            2018-09-10
Date of Test:                                               2018-09-25 to 2018-09-29
Date of Issue:                                              2018-09-30
Test Result:                                                Pass*
* In the configuration tested, the EUT complied with the standards specified above.




                   Keny Xu
             EMC Laboratory Manager
The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report.
If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new
system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS International
Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by SGS International
Electrical Approvals in writing.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180300231601
                                                                                                                                 Page:       2 of 14


                                                                                            Revision Record
                 Version                    Chapter                                           Date                                        Modifier                               Remark

                 01                                                                   2018-09-27                                                                                 Original




       Authorized for issue by:




                                                                     Moon Zhang /Project Engineer




                                                                     Eric Fu /Reviewer




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180300231601
                                                                                                                                 Page:       3 of 14


2          Test Summary
            Emission Part
                              Item                               Standard                                    Method                                     Requirement                               Result
            Conducted Emissions
                                                           47 CFR Part 15,
             at Mains Terminals                                                                     ANSI C63.4:2014                                           Class B                               Pass
                                                              Subpart B
              (150kHz-30MHz)
              Radiated Emissions                           47 CFR Part 15,
                                                                                                    ANSI C63.4:2014                                           Class B                               Pass
                (30MHz-1GHz)                                  Subpart B


                         Internal Source                                                                                   Upper Frequency
                        Below 1.705MHz                                                                                               30MHz
                    1.705MHz to 108MHz                                                                                                 1GHz
                      108MHz to 500MHz                                                                                                 2GHz
                        500MHz to 1GHz                                                                                                 5GHz
                             Above 1GHz                                    5th harmonic of the highest frequency or 40GHz, whichever is lower




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                              SGS—CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                    Report No.: SZENM1etso0zst601
                                                    Page        Aof 14

3          Contents
                                                                                Page
1.         covenprce
2.     Test summany.
s          contents
a    eenenaL inFonmation                                                            s
 41—     bemuscrEUT                                                                 s
 42.     Descartonor Supzort Uins                                                   s
 43      Mexsureent Uicermiay                                                       s
 aa     TesLoownon                                                                  s
 45— TestFroum                                                                      s
 48.     Devamonrromstawowes                                                        s
 47     AmvommumesrronStaicaro Conmions                                             s
s Eoupment List.                                                                    3
s          emssion tesr resuuts.                                                     a
     a.1 Coroucren EmssonsarMans Teruus B0z000z                                      s
    €.1.1 EUT. Operaton                                                              a
    €.1.2 TestSotup Diagram                                                          a
    618| Measuremont Data                                                            a
 s2 MaowieoBussous GoVHz1GH2)                                                       n
    €21 EUT.Operation                                                               n
    €22.. TestSetupDiagram                                                          n
    €28.| Measurmmont Data                                                          n
7 protocnaphs
 71— Tesrseme                                                                       14
 72. EUT Construenor«. Detas (2UT Proros;                                           14


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180300231601
                                                                                                                                 Page:       5 of 14


4          General Information
4.1 Details of E.U.T.
           Power supply:                                    Rechargeable battery LI-ION: DC 3.7V 740mAh 2.74Wh
                                                            Supplied by DC 5V Type-C port
           Cable:                                           Type-C cable: 80cm
                                                            3* Aux in cable: 8cm
           Internal source:                                 32MHz
           Frequency Range:                                 2402MHz to 2480MHz
           Bluetooth Version:                               V4.0 BT Single mode
                                                            Bluetooth LE
           Modulation Type:                                 GFSK
           Number of Channels:                              40
           Operation Frequency                              2402MHz to 2480MHz
           Receiver Category:                               2
           Antenna Type:                                    Chip Antenna
           Antenna Gain:                                    3.3dBi


4.2 Description of Support Units

     Description                                  Manufacturer                                              Model No.                                                   Serial No.
         Adapter                                   Apple                                            A1357 W010A051                                              REF. No.SEA0500
         Earphone                             Supplied by Client                                          N/A                                                          N/A
           Laptop                                        Lenovo                                                  T430u                                          REF. No.SEA1800
           Mouse                                         Lenovo                                             M-U0025-O                                           REF. No.:SEA2400
           Router                                    NETGEAR                                                 DGN2200                                            REF. No.SEA2200


4.3 Measurement Uncertainty

No.                                                      Item                                                                         Measurement Uncertainty
   1                                      Conduction Emission                                                                        ± 3.0dB (150kHz to 30MHz)
   2                                        Radiated Emission                                                                             ± 4.5dB (30MHz-1GHz)
   3                                          Temperature test                                                                                             ± 1°C
   4                                              Humidity test                                                                                            ± 3%




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180300231601
                                                                                                                                 Page:       6 of 14

4.4 Test Location
            All tests were performed at:
            SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch
            No. 1 Workshop, M-10, Middle Section, Science & Technology Park, Shenzhen, Guangdong, China.
            518057.
            Tel: +86 755 2601 2053                                    Fax: +86 755 2671 0594
            No tests were sub-contracted.

4.5 Test Facility
            The test facility is recognized, certified, or accredited by the following organizations:
            • CNAS (No. CNAS L2929)
            CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
            Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
            Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
            Laboratories) for the competence in the field of testing.
            • A2LA (Certificate No. 3816.01)
            SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
            American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
            • VCCI
            The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
            Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
            Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
            been registered in accordance with the Regulations for Voluntary Control Measures with Registration
            No.: G-20026, R-14188, C-12383 and T-11153 respectively.
            • FCC –Designation Number: CN1178
            SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
            as an accredited testing laboratory.
            Designation Number: CN1178. Test Firm Registration Number: 406779.
            • Innovation, Science and Economic Development Canada
            SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
            by ISED as an accredited testing laboratory.
            CAB identifier: CN0006.
            IC#: 4620C.
4.6 Deviation from Standards
            None
4.7 Abnormalities from Standard Conditions
            None




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180300231601
                                                                                                                                 Page:       7 of 14


5          Equipment List
Conducted Emissions at Mains Terminals (150kHz-30MHz)
            Equipment                                   Manufacturer                             Model No                   Inventory No                      Cal Date                Cal Due Date
        Shielding Room                           ChangZhou ZhongYu                                  GB-88                     SEM001-06                    2017-05-10                   2020-05-09
 Measurement Software                                          AUDIX                         e3 V5.4.1221d                            N/A                          N/A                         N/A
          Coaxial Cable                                          SGS                                   N/A                    SEM024-01                    2018-07-12                   2019-07-11
                   LISN                             Rohde & Schwarz                                ENV216                     SEM007-01                    2018-09-25                   2019-09-24
                   LISN                               ETS-LINDGREN                                  3816/2                    SEM007-02                    2018-04-02                   2019-04-01
      EMI Test Receiver                             Rohde & Schwarz                                   ESCI                    SEM004-02                    2018-04-02                   2019-04-01


Radiated Emissions (30MHz-1GHz)
            Equipment                                   Manufacturer                             Model No                   Inventory No                      Cal Date                Cal Due Date
     3m Semi-Anechoic
                                                      ETS-LINDGREN                                     N/A                    SEM001-01                    2017-08-05                   2020-08-04
         Chamber
                                                                                             e3 V8.2014-6-
 Measurement Software                                          AUDIX                                                                  N/A                          N/A                         N/A
                                                                                                  27
          Coaxial Cable                                          SGS                                   N/A                    SEM025-01                    2018-07-12                   2019-07-11
      EMI Test Receiver                           Agilent Technologies                             N9038A                     SEM004-05                    2018-09-25                   2019-09-24
     BiConiLog Antenna
                                                      ETS-LINDGREN                                  3142C                     SEM003-01                    2017-06-27                   2020-06-26
       (26-3000MHz)
          Pre-amplifier
                                                  Agilent Technologies                              8447D                     SEM005-01                    2018-04-02                   2019-04-01
         (0.1-1300MHz)


General used equipment
             Equipment                                  Manufacturer                             Model No                   Inventory No                      Cal Date                Cal Due Date
                                                         Shanghai
  Humidity/ Temperature
                                                       Meteorological                               ZJ1-2B                    SEM002-03                    2017-09-29                   2018-09-28
        Indicator
                                                      Industry Factory
                                                         Shanghai
  Humidity/ Temperature
                                                       Meteorological                               ZJ1-2B                    SEM002-04                    2017-09-29                   2018-09-28
        Indicator
                                                      Industry Factory
  Humidity/ Temperature
                                                                Mingle                                 N/A                    SEM002-08                    2017-09-29                   2018-09-28
        Indicator
                                                        Changchun
              Barometer                                Meteorological                                DYM3                     SEM002-01                    2018-04-08                   2019-04-07
                                                      Industry Factory




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180300231601
                                                                                                                                 Page:       8 of 14



6          Emission Test Results
6.1 Conducted Emissions at Mains Terminals (150kHz-30MHz)
           Test Requirement:                                47 CFR Part 15, Subpart B
           Test Method:                                     ANSI C63.4:2014
           Frequency Range:                                 150kHz to 30MHz
           Limit:
           0.15M-0.5MHz                                     66dB(µV)-56dB(µV) quasi-peak, 56dB(µV)-46dB(µV) average
           0.5M-5MHz                                        56dB(µV) quasi-peak, 46dB(µV) average
           5M-30MHz                                         60dB(µV) quasi-peak, 50dB(µV) average
           Detector:                                        Peak for pre-scan (9kHz resolution bandwidth) 0.15M to 30MHz

6.1.1 E.U.T. Operation
      Operating Environment:
      Temperature:      25 °C           Humidity: 60 % RH          Atmospheric Pressure: 1010 mbar
      Test mode         e: Normal working and being charged ,Keep the EUT working at normal working
                        with earphone.
6.1.2 Test Setup Diagram




6.1.3 Measurement Data
      An initial pre-scan was performed with peak detector.Quasi-Peak or Average measurement were
      performed at the frequencies with maximized peak emission were detected.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180300231601
                                                                                                                                 Page:       9 of 14


Mode:e; Line:Live Line




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180300231601
                                                                                                                                 Page:       10 of 14


Mode:e; Line:Neutral Line




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180300231601
                                                                                                                                 Page:       11 of 14


6.2 Radiated Emissions (30MHz-1GHz)
           Test Requirement:                                47 CFR Part 15, Subpart B
           Test Method:                                     ANSI C63.4:2014
           Frequency Range:                                 30MHz to 1GHz
           Measurement Distance:                            3m
           Limit:
           30MHz -88MHz                                     40.0(dBµV/m) quasi-peak
           88MHz-216MHz                                     43.5(dBµV/m) quasi-peak
           216MHz-960MHz                                    46.0(dBµV/m) quasi-peak
           960MHz-1000MHz                                   54.0(dBµV/m) quasi-peak
           Detector:                                        Peak for pre-scan (120kHz resolution bandwidth) 30M to1000MHz

6.2.1 E.U.T. Operation
      Operating Environment:
      Temperature:      25.4 °C         Humidity: 57.4 % RH        Atmospheric Pressure: 1010 mbar
      Pretest these     c: PC mode,Keep EUT working with PC and comunicating with each other.
      modes to find     d: Normal working,Keep the EUT working at normal working with earphone.
      the worst case:
                        e: Normal working and being charged ,Keep the EUT working at normal working
                        with earphone.
      The worst case    c:PC mode,Keep EUT working with PC and comunicating with each other.
      for final test:
6.2.2 Test Setup Diagram




6.2.3 Measurement Data
      An initial pre-scan was performed in the chamber using the spectrum analyser in peak detection
      mode. Quasi-peak measurements were conducted based on the peak sweep graph. The EUT was
      measured by BiConiLog antenna with 2 orthogonal polarities.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180300231601
                                                                                                                                 Page:       12 of 14


Mode:c; Polarization:Horizontal




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180300231601
                                                                                                                                 Page:       13 of 14


Mode:c; Polarization:Vertical




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180300231601
                                                                                                                                 Page:       14 of 14


7         Photographs

7.1 Test Setup
            Refer to EUT Setup photos

7.2 EUT Constructional Details (EUT Photos)
           Refer to EUT external and internal photos


                                                                                   - End of the Report -




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.



Document Created: 2018-11-02 03:51:07
Document Modified: 2018-11-02 03:51:07

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC