Test Report

FCC ID: YZZUCM6510

Test Report

Download: PDF
FCCID_2907725

                                                                  E506, 5th Floor, No.39 Keji Middle 2nd Rd, Science & Technology
                                                                  Park, Nanshan District, Shenzhen, P. R. China
                                                                  Tel: + 86 755 83642690       Fax: + 86 755 83297077
                                                                  www.kmolab.com




                         FCC TEST REPORT
                                                 Under:
                                            FCC Part 15, Class B

                                                 Prepared For:

                             Grandstream Networks, Inc.
4th Floor, Rainbow Technology Building #16 New West Rd, Nanshan Science & Technology Park
                           (North District),Shenzhen, China 518057


                                         FCC ID: YZZUCM6510
                                                EUT: IP PBX
                                             Model: UCM6510


                                               February 4, 2016
                                                    Issue Date:

                                              Extension Report
                                                  Report Type:



                                             Test Engineer: Eric Guo




                                          Review By: Apollo Liu / Manager




The test report consists 22 pages in total. It may be duplicated completely for legal use with the allowance of the
applicant. It shall not be reproduced except in full, without the written approval of Ke Mei Ou Laboratory
Corporation. The test result in the report only applied to the tested sample.


Grandstream Networks, Inc.                                                                                                                           FCC ID: YZZUCM6510


                                                                   TABLE OF CONTENTS

1. General Information ........................................................................................................................................................... 3
   1. 1 Notes............................................................................................................................................................................... 3
   1. 2 Testing Laboratory .......................................................................................................................................................... 3
   1. 3 Details of Applicant ........................................................................................................................................................ 3
   1. 4 Application Details ......................................................................................................................................................... 3
   1. 5 Test Item ......................................................................................................................................................................... 3
   1. 6 Test Standards ................................................................................................................................................................. 3
2. Technical Test ...................................................................................................................................................................... 4
   2. 1 Summary of Test Results ................................................................................................................................................ 4
   2. 2 Measurement Uncertainty ............................................................................................................................................... 4
3. Modifications ....................................................................................................................................................................... 4
4. Conducted Power Line Test................................................................................................................................................ 5
   4. 1 Test Equipment ............................................................................................................................................................... 5
   4. 2 Test Procedure ................................................................................................................................................................ 5
   4. 3 Test Setup ....................................................................................................................................................................... 5
   4. 4 Configuration of The EUT.............................................................................................................................................. 6
   4. 5 EUT Operating Condition............................................................................................................................................... 7
   4. 6 Conducted Power Line Emission Limits ........................................................................................................................ 7
   4. 7 Conducted Power Line Test Result ................................................................................................................................. 8
5. Radiated Emission Test ..................................................................................................................................................... 10
   5. 1 Test Equipment ............................................................................................................................................................. 10
   5. 2 Test Procedure .............................................................................................................................................................. 10
   5. 3 Radiated Test Setup ...................................................................................................................................................... 10
   5. 4 Configuration of The EUT.............................................................................................................................................11
   5. 5 EUT Operating Condition..............................................................................................................................................11
   5. 6 Radiated Emission Limit ...............................................................................................................................................11
   5. 7 Radiated Emission Test Result...................................................................................................................................... 12
6. Photo of Testing ................................................................................................................................................................. 15
   6.1 Emission test view ......................................................................................................................................................... 15
   6.2 Photograph - EUT.......................................................................................................................................................... 17
7. FCC ID Label..................................................................................................................................................................... 21
8. Test Equipment.................................................................................................................................................................. 22




KMO FCC ID Report                                                                         Page 2 of 22                                          Report #: KSZ2016010703J


Grandstream Networks, Inc.                                                                       FCC ID: YZZUCM6510


1. General Information
1. 1 Notes
The test results of this report relate exclusively to the test item specified in 1.5. The KMO Lab does not assume
responsibility for any conclusions and generalizations drawn from the test results with regard to other specimens or samples
of the type of the equipment represented by the test item. The test report may only be reproduced or published in full.
Reproduction or publication of extracts from the report requires the prior written approval of the KMO Lab.

1. 2 Testing Laboratory
Ke Mei Ou Laboratory Co., Ltd.
ANSI-ASQ National Accreditation Board/ACLASS ISO/IEC 17025 Accredited Lab for telecommunication standards. The
Registration Number is AT-1532. The testing quality system meets with ISO/IEC-17025 requirements, This approval results
is accepted by MRA of ILAC.
FCC Test Site Registration Number: 962205
IC Test Site Registration Number: 4986A-2
Internet: www.kmolab.com

1. 3 Details of Applicant
 Name         : Grandstream Networks, Inc.
 Address      : 4th Floor, Rainbow Technology Building #16 New West Rd, Nanshan Science & Technology Park
                (North District),Shenzhen, China 518057




1. 4 Application Details
Date of Receipt of Application            : January 7, 2016
Date of Receipt of Test Item              : January 7, 2016
Date of Test                              : January 18~February 4, 2016

1. 5 Test Item
 Manufacturer                              : Same as applicant
 Address                                   : Same as applicant
 Trade Name                                : Grandstream
 Model No.(Base)                           : UCM6510
 Model No.(Extension)                      : N/A
 Description                               : IP PBX

Additional Information
 Product Type                              : N/A
 Radio Type                                : N/A
 Power Type                                : DC 12V/1.5A(Adapter model:F18W8-120150SPAU)
 Modulation                                : N/A
 Data Modulation                           : N/A
 Date Rate (Mbps)                          : N/A
 Frequency Range                           : N/A
 Channel Number                            : N/A
 Antenna                                   : N/A

1. 6 Test Standards
                                               FCC Part 15, Class B
Note: All radiated measurements were made in all three orthogonal planes. The values reported are the maximum values.




KMO FCC ID Report                                          Page 3 of 22                       Report #: KSZ2016010703J


Grandstream Networks, Inc.                                                                     FCC ID: YZZUCM6510


2. Technical Test
2. 1 Summary of Test Results

                    The EUT has been tested according to the following specifications:
                      Standard                        Test Type       Result           Notes
               FCC Part 15, Paragraph 15.107                   Conducted Test      PASS               Complies
               FCC Part 15, Paragraph 15.109                    Radiated Test      PASS               Complies


2. 2 Measurement Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT as
specified in CISPR 16-4-2:
           Measurement                               Frequency                                 Uncertainty
        Conducted emissions                      0.15MHz~30MHz                                     1.72
         Radiated emissions                      30MHz ~ 300MHz                                    3.88
         Radiated emissions                     300MHz ~1000MHz                                    3.86
         Radiated emissions                    1000MHz ~18000MHz                                   5.28

This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage
factor of k=2.

Consistent with industry standard (e.g. CISPR 22: 2006, clause 11, Measurement Uncertainty) determining compliance with
the limits shall be base on the results of the compliance measurement. Consequently the measure emissions being less than
the maximum allowed emission result in this be a compliant test or passing test.

The acceptable measurement uncertainty value without requiring revision of the compliance statement is base on conducted
and radiated emissions being less than UCISPR which is 3.6dB and 5.2dB respectively. KMO values (called ULab in CISPR
16-4-2) is less than UCISPR as shown in the table above.
Therefore, MU need not be considered for compliance.


3. Modifications
This product is an extension of original report under FCC ID: YZZUCM6510
The applicant declare that the reasons for this Class II permissive change as below:
*Add one power adapter(Model:F18W8-120150SPAU)and has the same electrical specification with original power
adapter
Anything else are the same as before.




KMO FCC ID Report                                         Page 4 of 22                      Report #: KSZ2016010703J


Grandstream Networks, Inc.                                                                    FCC ID: YZZUCM6510



4. Conducted Power Line Test
4. 1 Test Equipment
Please refer to Section 8 this report.


4. 2 Test Procedure
The EUT and simulators are connected to the main power through a line impedance stabilization network (L.I.S.N.). This
provides a 50 ohm/50uH coupling impedance for the measuring equipment. The peripheral devices are also connected to the
main power through a LISN that provides a 50ohm/50uH coupling impedance with 50ohm termination.

Both sides of A.C. line are checked for maximum conducted interference. In order to find the maximum emission., the
relative positions of equipment and all of the interface cables must be changed according to ANSI C63.4:2014 on conducted
measurement. Conducted emissions were invested over the frequency range from 0.15MHz to 30MHz using a receiver
bandwidth of 9kHz.


4. 3 Test Setup


             Vertical Reference
               Ground Plane



                                                                            Test receiver
      40cm
                    EUT                  Peripheral




                                                      80cm
       LISN



                                                        Horizontal Reference
                                                            Ground Plane
For the actual test configuration, Please refer to the related items – Photos of Testing.




KMO FCC ID Report                                         Page 5 of 22                      Report #: KSZ2016010703J


Grandstream Networks, Inc.                                                                   FCC ID: YZZUCM6510


4. 4 Configuration of The EUT
The EUT was configured according to ANSI C63.4:2014. All interface ports were connected to the appropriate peripherals.
All peripherals and cables are listed below.


A. EUT
           Device                         Manufacturer                           Model #                 FCC ID
           IP PBX                         Same as applicant                      UCM6510             YZZUCM6510


B. Internal Devices
          Device                         Manufacturer                            Model #             FCCID / DoC
            N/A




C. Peripherals
                                                   Model #             FCC ID/
      Device              Manufacturer                                                             Cable
                                                   Serial #             DoC
     Notebook                 DELL                  PP10L               DoC             1.5m unshielded power cord
     IP Phone           GRANDSTREAM                GXP1625         YZZGXP16XX                      N/A
   Analog Phone             SINATEL                GCE6010              DoC                        N/A




KMO FCC ID Report                                       Page 6 of 22                       Report #: KSZ2016010703J


Grandstream Networks, Inc.                                                              FCC ID: YZZUCM6510


4. 5 EUT Operating Condition

Operating condition is according to ANSI C63.4:2014.
A. Setup the EUT and simulators as shown on follow.
B. Enable RF signal and confirm EUT active.
A. Modulate output capacity of EUT up to specification.




                  120V/60Hz                                                                120V/60Hz
                  AC Mains                                                                 AC Mains
                  Via Class 2                                                              Via Class 2
                  Adaptors                                                                 Adaptors


                                  Telephone     Telephone         Notebook   EUT




4. 6 Conducted Power Line Emission Limits

               Frequency Range (MHz)              Class A QP/AV (dBuV)       Class B QP/AV (dBuV)
                      0.15 – 0.5                              79/66                66 –56/56 –46
                       0.5 – 5.0                              73/60                    56/46
                        5.0 – 30                              73/60                    60/50
Note: In the above table, the tighter limit applies at the band edges.




KMO FCC ID Report                                           Page 7 of 22              Report #: KSZ2016010703J


Grandstream Networks, Inc.                                                                           FCC ID: YZZUCM6510


4. 7 Conducted Power Line Test Result
 Product                : IP PBX                                      Test Mode            : Normal Link / Auto
 Test Item              : Conducted Emission Data                     Temperature          : 25 ℃
 Test Voltage           : DC 12V                                      Humidity             : 56%RH
 Test Result            : PASS                                        Adapter Model        :

The frequency spectrum from 0.15 MHz to 30 MHz was investigated. All readings are quasi -peak values with a resolution
bandwidth of 9 KHz.
. Temperature : 26 ℃
. Humidity      : 53 % RH
Adapter model:F18W8-120150SPAU
                                            FCC 15 Class B
                Read Level                  Emission                         Limit             Margin
 Frequency       (dBuV)         Factor       (dBuV)       Line/             (dBuV)             (dBuV)
   (MHz)        QP     AV        (dB)      QP      AV Neutral              QP      AV        QP       AV
    0.150       31.97   21.04    10.30    42.27     31.34      Line        66.00   56.00    -23.73     -24.66
    0.150       32.58   21.94    10.30    42.88     32.24    Neutral       66.00   56.00    -23.12     -23.76
    0.158       31.92   22.16    10.30    42.22     32.46     Line         65.57   55.57    -23.35     -23.11
    0.210       31.16   26.54    10.30    41.46     36.84    Neutral       63.21   53.21    -21.75     -16.37
    0.266       30.52   24.63    10.30    40.82     34.93     Line         61.24   51.24    -20.42     -16.31
    0.270       32.81   24.57    10.30    43.11     34.87    Neutral       61.12   51.12    -18.01     -16.25
                                              FCC 15 Class B
Note: NF = No Significant Peak was Found.
Note:
1.Uncertainty in conducted emission measured is <+/ -2dB.
2.The emission levels of other frequencies were very low against the limit.
3.All Reading Levels are Quasi-Peak and Average value.
4.Emission = Meter Reading + Factor; Factor = Insertion Loss + Cable Loss.
5.Margin Value = Emission Level - Limit Value.




KMO FCC ID Report                                           Page 8 of 22                        Report #: KSZ2016010703J


Grandstream Networks, Inc.                          FCC ID: YZZUCM6510


Conducted Emission
FCC 15.107
Test Specification: LINE&NEUTRAL
Comment:
Adapter model: F18W8-120150SPAU




KMO FCC ID Report                  Page 9 of 22   Report #: KSZ2016010703J


Grandstream Networks, Inc.                                                                       FCC ID: YZZUCM6510



5. Radiated Emission Test
5. 1 Test Equipment
Please refer to Section 8 this report.


5. 2 Test Procedure

1. The EUT was tested according to ANSI C63.4:2014.
2. The EUT, peripherals were put on the turntable which table size is 1m x 1.5 m, table high 0.8 m, and which is 1.5 m high
   for above 1 GHz. All set up is according to ANSI C63.4:2014 .
3. The frequency spectrum from 9 kHz to 25 GHz was investigated. All readings from 9 kHz to 150 kHz are quasi-peak
   values with a resolution bandwidth of 200 Hz. All readings from 150 kHz to 30 MHz are quasi-peak values with a
   resolution bandwidth of 9 KHz. All readings from 30 MHz to 1 GHz are quasi-peak values with a resolution bandwidth of
   120 KHz. All readings are above 1 GHz , peak values with a resolution bandwidth of 1 MHz . Measurements were made
   at 3 meters.
4. The emissions from the EUT were measured continuously at every azimuth by rotating the turntable. The Receiving
   antenna high is varied from 1 m to 4 m high to find the maximum emission for each frequency. Emissions below 30MHz
   were measured with a loop antenna while emission above 30MHz were measured using a broadband E-field antenna.
5. Maximizing procedure was performed on the six (6) highest emissions to ensure EUT compliance is with all installation
   combinations. All data was recorded in the peak detection mode. Quasi-peak readings was performed only when an
   emission was found to be marginal (within -4 dB of specification limit), and are distinguished with a "QP" in the data
   table.
6. Each emission was to be maximized by changing the polarization of receiving antenna both horizontal and vertical. In
   order to find out the max. emission, the relative positions of this transmitter(EUT) was rotated through three orthogonal
   axes according to the requirements in Section 8 and 13 of ANSI C63.4:2014

5. 3 Radiated Test Setup
For Frequencies below 30 MHz




                                                                  3M
                                         EUT


Ground
Plane           80cm


                                TURN TABLE


                                                                                           Test Receiver
          For the actual test configuration , please refer to the related items – Photos of Testing




KMO FCC ID Report                                         Page 10 of 22                       Report #: KSZ2016010703J


Grandstream Networks, Inc.                                                                        FCC ID: YZZUCM6510


For Frequencies above 30 MHz

                                                                            Antenna        Antenna Tower




                                                                                                         1- 4m
                                                                                                        Variable



                                                                   3M
                                     EUT


Ground
Plane          80cm


                               TURN TABLE


                                                                                          Test Receiver
                 For the actual test configuration , please refer to the related items – Photos of Testing


5. 4 Configuration of The EUT
Same as section 4.4 of this report
5. 5 EUT Operating Condition
Same as section 4.5 of this report
5. 6 Radiated Emission Limit
All emission from a digital device, including any network of conductors and apparatus connected thereto, shall not exceed
the level of field strength specified below:

                          Frequencies in restricted band are complied to limit on Paragraph 15.109.
                        Frequency (MHz)          Distance (m)         Field Strength (dBuV/m)
                                30 - 88                 3                         40.0
                               88 - 216                 3                         43.5
                              216 - 960                 3                         46.0
                              Above 960                 3                         54.0
Note:
1. In the emission tables above, the tighter limit applies at the band edges.
2. Distance refers to the distance between measuring instrument, antenna, and the closest point of any part of the device or
   system.
3. The lower limit shall apply at the transition frequencies.




KMO FCC ID Report                                           Page 11 of 22                     Report #: KSZ2016010703J


Grandstream Networks, Inc.                                                                   FCC ID: YZZUCM6510


5. 7 Radiated Emission Test Result
 Product                 : IP PBX                                    Test Mode       : Normal Link / Auto
 Test Item               : Fundamental Radiated Emission Data        Temperature     : 25 ℃
 Test Voltage            : DC 12V                                    Humidity        : 56%RH
 Test Result             : PASS                                      Model           :

For Frequency below 30MHz
     Freq.        Emission (dBuV/m)             HORIZ /             Limits              Margin
    (MHz)              QP Detector               VERT             (dBuV/m)               (dB)
      N/A
      N/A
      N/A
      N/A
      N/A
      N/A
Note:      (1) All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements
                as necessary.
           (2) “N/A” remark, if no specific emissions from the EUT are recorded (ie: margin>20dB from the applicable
                limit) and considered that’s already beyond the background noise floor.
           (3) Emission Level = Reading Level + Probe Factor + Cable Loss.
For Frequency from 30MHz to 1GHz
                                         Adapter model:F18W8-120150SPAU
                                FCC 15 Class B
                Read                 Emission
 Frequency     Level      Factor                   Horiz./     Limit      Margin
   (MHz)      (dBuV)        (dB)    (dBuV/m)        Vert.   (dBuV/m)       (dB)
  250.000        27.38        14.93     42.31      Horiz./        46.0      -3.69
   40.000        22.57        12.41     34.98       Vert.         40.0      -5.02
  325.000        26.66        17.13     43.78      Horiz./        46.0       -2.22
  250.000        19.82        14.93     34.75       Vert.         46.0      -11.25
  375.000        27.79        17.13     44.91      Horiz./        46.0       -1.09
  375.000        24.36        17.13     41.48       Vert.         46.0      -4.52
                                  FCC 15 Class B
Note:           (1) All Readings below 1GHz are Quasi-Peak, above are performed
                    with peak and/or average measurements as necessary.
                (2) “N/A” remark, if no specific emissions from the EUT are
                    recorded (ie: margin>20dB from the applicable limit) and
                    considered that’s already beyond the background noise floor.
                (3) Emission Level = Reading Level + Probe Factor + Cable Loss.




KMO FCC ID Report                                           Page 12 of 22                 Report #: KSZ2016010703J


Grandstream Networks, Inc.                                                                 FCC ID: YZZUCM6510


Frequency above 1 GHz
                                             FCC 15 Class B
                 Read
 Frequency    Level(dBuV)    Factor    Emission(dBuV/m)       Horiz./   Limit (dBuV/m)       Margin(dB)
   (MHz)      PK      AV      (dB)      PK        AV           Vert.     PK       AV         PK     AV
  2237.20    31.66   18.59    14.93     46.59      33.52      Horiz./   74.0      54.0      -27.41   -20.48
  2128.00    33.27   20.13    12.41     45.68      32.54       Vert.    74.0      54.0      -28.32   -21.46
  2466.80    36.11   16.85    17.13     53.23      33.97      Horiz./   74.0      54.0      -20.77   -20.03
  2496.40    31.63   18.41    14.93     46.56      33.34       Vert.    74.0      54.0      -27.44   -20.66
  2844.00    32.24   18.89    17.13     49.36      36.01      Horiz./   74.0      54.0      -24.64   -17.99
  2897.60    31.87   19.10    17.13     48.99      36.22       Vert.    74.0      54.0      -25.01   -17.78
                                             FCC 15 Class B

 Note:       (1) All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average
                 measurements as necessary.
             (2) Emission Level = Reading Level + Probe Factor + Cable Loss.




KMO FCC ID Report                                     Page 13 of 22                      Report #: KSZ2016010703J


Grandstream Networks, Inc.                                                             FCC ID: YZZUCM6510


Radiated Emission
FCC 15.109
For Frequency from 30MHz to 1GHz
Adapter model: F18W8-120150SPAU
                                         RBW    120 kHz Marker 1 [T1 ]
                                         MT     100 ms          44.86 dBµV/m
                              Att 0 dB   PREAMP OFF        375.000000000 MHz
dBµV    100                   100 MHz                                 1 GHz
/m

        90

1 PK
VIEW
        80

2 PK
MAXH
        70                                                                     TDS



        60



        50
                                                       1

        FCC15BF
        40



        30



        20



        10


        0

        30 MHz                                                         1 GHz



Date:         19.JAN.2016   10:10:47




KMO FCC ID Report                                          Page 14 of 22             Report #: KSZ2016010703J


Grandstream Networks, Inc.                                    FCC ID: YZZUCM6510



6. Photo of Testing
6.1 Emission test view

                             Conducted Emission test view




KMO FCC ID Report                       Page 15 of 22       Report #: KSZ2016010703J


Grandstream Networks, Inc.                                                    FCC ID: YZZUCM6510


                    Radiated Emission test view (Frequency from 30MHz to 1GHz)




                         Radiated Emission test view (Frequency above 1GHz)




KMO FCC ID Report                              Page 16 of 22              Report #: KSZ2016010703J


Grandstream Networks, Inc.                        FCC ID: YZZUCM6510


6.2 Photograph - EUT

                             EUT top view




KMO FCC ID Report               Page 17 of 22   Report #: KSZ2016010703J


Grandstream Networks, Inc.                          FCC ID: YZZUCM6510




                             EUT bottom view




KMO FCC ID Report                 Page 18 of 22   Report #: KSZ2016010703J


Grandstream Networks, Inc.                     FCC ID: YZZUCM6510




KMO FCC ID Report            Page 19 of 22   Report #: KSZ2016010703J


Grandstream Networks, Inc.                          FCC ID: YZZUCM6510


                             Adapter top view




                             Adapter side view




KMO FCC ID Report                 Page 20 of 22   Report #: KSZ2016010703J


Grandstream Networks, Inc.                                                                      FCC ID: YZZUCM6510



7. FCC ID Label




The following note shall be conspicuously placed in the users manual: “Operation is subject to the following two
conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of this device.”

The Label must not be a stick-on paper label. The Label on these products must be permanently affixed to the product and
readily visible at the time of purchase and must last the expected lifetime of the equipment not be readily detachable.


                                        Proposed Label Location on EUT




KMO FCC ID Report                                         Page 21 of 22                      Report #: KSZ2016010703J


Grandstream Networks, Inc.                                                       FCC ID: YZZUCM6510



8. Test Equipment
        The following test equipments were used during the radiated & conducted emission test:
     Equipment/            Manufacturer            Model #             Serial No.        Due Date
      Facilities
          Turntable           Innco systems GmbH        CT-0801      KMO-SZ114               NCR
        Antenna Tower         Innco systems GmbH      MM4000-PP      KMO-SZ115               NCR
          Controller          Innco systems GmbH        CO2000       KMO-SZ116               NCR
        Pre-Amplifier                Agilent            87405C       KMO-SZ155            Dec.6, 2016
        Pre-Amplifier             Com-Power            PAM-840       KMO-SZ156            Dec.6, 2016
        Horn Antenna              Com-Power             AH-840       KMO-SZ157            Dec.6, 2016
     EMI Test Receiver          Rohde & Schwarz          ESPI7       KMO-SZ002           June 27, 2016
     Spectrum Analyzer          Rohde & Schwarz          FSP40       KMO-SZ003           June 27, 2016
       Signal Generator              FLUKE            PM5418+Y/C     KMO-SZ020           May 27, 2016
        Loop Antenna            Rohde & Schwarz        HFH2-Z2       KMO-SZ004          August 19, 2018
  Trilog-Super Broadband
                               SCHWARZBECK             VULB9161      KMO-SZ005          August 27, 2018
           Antenna
  Trilog-Super Broadband
                               SCHWARZBECK             VULB9161      KMO-SZ006          August 19, 2018
           Antenna
 Broad-Band Horn Antenna       SCHWARZBECK           BBHA 9120D      KMO-SZ007          August 19, 2018
 Broad-Band Horn Antenna       SCHWARZBECK           BBHA 9120D      KMO-SZ008          August 19, 2018
            AMN                Rohde & Schwarz         ESH3-Z5       KMO-SZ009           June 27, 2016
         Pulse Limiter         SCHWARZBECK           VTSD 9561-F     KMO-SZ077           Nov.29, 2016
             ISN               SCHWARZBECK          NTFM 8158 CAT3   KMO-SZ070           Nov.19, 2016
             ISN               SCHWARZBECK          NTFM 8158 CAT5   KMO-SZ071           Nov.19, 2016
             ISN               SCHWARZBECK          NTFM 8158 CAT6   KMO-SZ072           Nov.19, 2016
    KMO Shielded Room               KMO                KMO-001       KMO-SZ036               NCR
     Coaxial Cable with
                               SCHWARZBECK              AK9515H      KMO-SZ037           Sep.18, 2016
        N-Connectors
AC Power Source / Analyzer         Agilent               6813B       KMO-SZ166           July 22, 2016
         Power Meter           Rohde & Schwarz          OSP-B157     KMO-HK015            Nov.6, 2016
Digital Radio Communication
                               Rohde & Schwarz           CMD60       KMO-SZ169           April 10, 2016
            Tester
       Universal Radio
                               Rohde & Schwarz          CMU200       KMO-SZ170           April 10, 2016
   Communication Tester
   Regulatory Test System
                               Rohde & Schwarz           TS8997      KMO-HK015            Nov.6, 2016
     30 MHz to 40 GHz
 Program Control Telephone
                                   Excelltel           CDX8000-M     KMO-SZ221               NCR
          Exchanger
   3m Anechoic Chamber              KMO                KMO-3AC       KMO-3AC-1           Nov.12, 2016
         Temperature
                                   TABAI               PSL-4GTW         N/A              Feb.10, 2016
           Chamber




KMO FCC ID Report                                  Page 22 of 22              Report #: KSZ2016010703J



Document Created: 2019-11-21 04:41:05
Document Modified: 2019-11-21 04:41:05

© 2024 FCC.report