Test Report

FCC ID: YZZ-GXW4216

Test Report

Download: PDF
FCCID_4201348

                                   FCC PART 15B, CLASS B
                                                 TEST REPORT

                                                                 For


                                Grandstream Networks, Inc.
                            126 Brookline Ave., 3rd Floor Boston, MA 02215, USA



                                          FCC ID: YZZ-GXW4216


               Report Type:                                         Product Type:
               Original Report                                      Analog IP Gateway



                    Report Number:             RSZ181225006-00


                         Report Date:          2019-02-20
                                               Xiangguang Kong

                        Reviewed By:           Engineer

                         Prepared By:          Bay Area Compliance Laboratories Corp. (Shenzhen)
                                               6/F., West Wing, Third Phase of Wanli Industrial
                                               Building, Shihua Road, Futian Free Trade Zone,
                                               Shenzhen, Guangdong, China
                                               Tel: +86-755-33320018
                                               Fax: +86-755-33320008
                                               www.baclcorp.com.cn




Note: This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of
the Federal Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk
“*”.


  Bay Area Compliance Laboratories Corp. (Shenzhen)                                                                          Report No.: RSZ181225006-00




                                                       TABLE OF CONTENTS


GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 MEASUREMENT UNCERTAINTY ....................................................................................................................................3
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  SPECIAL ACCESSORIES .................................................................................................................................................5
  EQUIPMENT MODIFICATIONS .......................................................................................................................................5
  SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................5
  EXTERNAL I/O CABLE..................................................................................................................................................5
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................7

TEST EQUIPMENT LIST ...........................................................................................................................................8
FCC §15.107 – AC LINE CONDUCTED EMISSIONS .............................................................................................9
  APPLICABLE STANDARD ..............................................................................................................................................9
  EUT SETUP ..................................................................................................................................................................9
  EMI TEST RECEIVER SETUP .........................................................................................................................................9
  TEST PROCEDURE ........................................................................................................................................................9
  CORRECTED FACTOR & MARGIN CALCULATION .......................................................................................................10
  TEST RESULTS SUMMARY ..........................................................................................................................................10
  TEST DATA ................................................................................................................................................................10
FCC §15.109 - RADIATED SPURIOUS EMISSIONS ............................................................................................15
  APPLICABLE STANDARD ............................................................................................................................................15
  EUT SETUP ................................................................................................................................................................15
  EMI TEST RECEIVER SETUP .......................................................................................................................................16
  TEST PROCEDURE ......................................................................................................................................................16
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................16
  TEST RESULTS SUMMARY ..........................................................................................................................................16
  TEST DATA ................................................................................................................................................................17




FCC Part 15B, Class B                                                                                                                                  Page 2 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)                             Report No.: RSZ181225006-00

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)

                 Product                Analog IP Gateway
              Tested Model              GXW4216
             Voltage Range              DC 12.0V from adapter
                Measure                 44.0 cm (L) *18.5 cm (W) *4.4 cm (H)
       Highest operating frequency      400 MHz
               Date of Test             Jan 16, 2019~ Jan 23, 2019
          Sample serial number          181225006
             Received date              2018-12-25
           Sample/EUT Status            Good condition
                                        Model: NBS65A120500M3
          Adapter information           Input: AC 100-240V, 50/60Hz, 1.5 A
                                        Output: DC 12.0V, 5.0 A


Objective
This test report is prepared on behalf of Grandstream Networks, Inc. in accordance with Part 2-Subpart J,
Part 15-Subparts A, B of the Federal Communication Commissions rules.

The objective of the manufacturer is to determine the compliance of the EUT with FCC Part 15 B.


Related Submittal(s)/Grant(s)
No Related Submittal(s)/Grant(s).


Test Methodology
All measurements contained in this report were conducted with ANSI C63.4-2014, American National
Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and
Electronic Equipment in the range of 9 kHz to 40 GHz.

All emissions measurement was performed at Bay Area Compliance Laboratories Corp. (Shenzhen). The
radiated testing was performed at an antenna-to-EUT distance of 3 meters.


Measurement Uncertainty

                        Parameter                              uncertainty
                Conducted Emissions                             ±1.95dB

            Radiated            Below 1GHz                      ±4.75dB
            Emissions           Above 1GHz                      ±4.88dB




FCC Part 15B, Class B                                                                         Page 3 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)                         Report No.: RSZ181225006-00

Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Shenzhen) to collect test data is located
on the 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road, Futian Free Trade Zone,
Shenzhen, Guangdong, China.

The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public
Access Link (PAL) database, FCC Registration No.: 342867, the FCC Designation No.: CN1221.

The test site has been registered with ISED Canada under ISED Canada Registration Number 3062B.




FCC Part 15B, Class B                                                                      Page 4 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)                            Report No.: RSZ181225006-00

SYSTEM TEST CONFIGURATION
Description of Test Configuration
The system was configured for testing in a manufacturer testing fashion.


EUT Exercise Software
No exercise software was used.


Special Accessories
No special accessory.


Equipment Modifications
No modification was made to the EUT tested.


Support Equipment List and Details


       Manufacturer          Description              Model                    Serial Number

         ASKPCB              FXS test tool           E239218                        N/A
          Sagem                  Router          F@ST 1704N                     3c81d839027c

External I/O Cable

               Cable Description               Length (m)          From/Port                   To

        Unshielded detachable AC cable               1.0            Adapter                  LISN

       Unshielded un-detachable DC cable             0.95           Adapter                   EUT

        Unshielded detachable RJ45 cable             10.0             EUT                    Router

        Unshielded detachable RJ11 cable             0.75             EUT                 FXS test tool




FCC Part 15B, Class B                                                                          Page 5 of 25


          Bay Area Compliance Laboratories Corp. (Shenzhen)                              Report No.: RSZ181225006-00

     Block Diagram of Test Setup
     RJ11:


                                                                                                                      LISN
 Router
                                                   FXS Test                EUT            Adapter
                                                     Tool         10cm            10cm




                                                                                                       1.0 meter
                     Non-Conductive Table
                     80 cm above Ground Plane

                                                      1.5 meters


     50-pin Telco connectors:

                                                                                                                           LISN

Router
                                                                         EUT             Adapter
                                                    FXS Test                     10cm
                                                      Tool
                                                                                                    1.0 meter




                    Non-Conductive Table
                    80 cm above Ground Plane

                                                     1.5 meters




     FCC Part 15B, Class B                                                                                         Page 6 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)                      Report No.: RSZ181225006-00

SUMMARY OF TEST RESULTS

                FCC Rules                     Description of Test              Results

                  §15.107                AC Line Conducted Emissions         Compliance

                  §15.109                 Radiated Spurious Emissions        Compliance




FCC Part 15B, Class B                                                                    Page 7 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)                                Report No.: RSZ181225006-00

TEST EQUIPMENT LIST

                                                                     Serial        Calibration     Calibration
     Manufacturer            Description            Model
                                                                    Number            Date          Due Date
                                       AC Line Conducted Emission Test
   Rohde & Schwarz       EMI Test Receiver          ESCS30          100176         2018-07-11      2019-07-11
                                                                 3560.6650.12-
   Rohde & Schwarz              LISN                ENV216                         2018-12-21      2019-12-21
                                                                  101613-Yb
   Rohde & Schwarz        Transient Limiter         ESH3Z2         DE25985         2018-11-12      2019-05-12

   Rohde & Schwarz        CE Test software          EMC 32          V8.53.0           NCR              NCR
                         Conducted Emission                      UF A210B-1-
       Unknown                                       78652                         2018-11-12      2019-05-12
                               Cable                             0720-504504

                                               Radiated Emission Test
      A.H.System            Horn Antenna          SAS-200/571           135        2018-09-01      2021-08-31
   Rohde & Schwarz         Signal Analyzer           FSEM         845987/005       2018-06-23      2019-06-23
     Sunol Sciences      Broadband Antenna            JB1         A040904-1        2017-12-22      2020-12-21
     COM-POWER              Pre-amplifier           PA-122          181919         2018-11-12      2019-05-12
   Sonoma instrument          Amplifier              310N           186238         2018-11-12      2019-05-12
   Rohde & Schwarz        EMI Test Receiver          ESCI           101120         2019-01-11      2020-01-11
       Ducommun                                    UFA147A-       MFR64639
                              RF Cable                                             2018-07-11      2021-07-10
      technologies                                2362-100100     231029-003

       Ducommun
                              RF Cable              104PEA        218124002        2018-11-12      2019-05-12
      technologies
       Ducommun
                              RF Cable              RG-214               1         2018-11-12      2019-05-12
      technologies
       Ducommun
                              RF Cable              RG-214               2         2018-11-12      2019-05-12
      technologies

   Rohde & Schwarz        Auto test software        EMC 32           V9.10            NCR              NCR


* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
been performed in accordance to requirements that traceable to National Primary Standards and International System
of Units (SI).




FCC Part 15B, Class B                                                                              Page 8 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)                          Report No.: RSZ181225006-00

FCC §15.107 – AC LINE CONDUCTED EMISSIONS
Applicable Standard
According to FCC §15.107


EUT Setup




The measurement procedure of EUT setup is according with per ANSI C63.4-2014. The related limit was
specified in FCC Part 15.107 Class B.

The spacing between the peripherals was 10 cm.

EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                              Frequency Range                      IF B/W
                              150 kHz – 30 MHz                      9 kHz


Test Procedure
During the conducted emission test, the host PC was connected to the first LISN and the other relevant
equipments were conncected to the second LISN.
Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.

FCC Part 15B, Class B                                                                       Page 9 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)                               Report No.: RSZ181225006-00

Corrected Factor & Margin Calculation
The Corrected factor is calculated by adding LISN/ISN VDF (Voltage Division Factor), Cable Loss and
Transient Limiter Attenuation. The basic equation is as follows:
      Correction Factor = LISN VDF + Cable Loss + Transient Limiter Attenuation
The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7 dB means the emission is 7 dB below the limit. The equation for margin
calculation is as follows:
      Margin = Limit – Corrected Amplitude

Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Part 15.107,

Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level is in compliance with the limit if

                                            Lm + U(Lm) ≤ Llim + Ucispr

In BACL., U(Lm) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.

Test Data
     Environmental Conditions

               Temperature:                24 ℃
          Relative Humidity:               60 %
              ATM Pressure:              101.0 kPa

      The testing was performed by Joson Xiao on 2019-01-16.

      EUT Operation Mode: Full load




FCC Part 15B, Class B                                                                             Page 10 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)                                     Report No.: RSZ181225006-00


RJ11 Port:
    AC 120V/60 Hz, Line



                         90


                         80


                         70

                                                                                                        QP
                         60
          Level in dBu




                                                                                                        AV
                         50


                         40


                         30


                         20


                         10


                         0
                         150k   300 400 500   800 1M        2M     3M     4M 5M 6     8 10M       20M    30M
                                                        Frequency in Hz



                                Corrected     Correction
         Frequency                                                Limit         Margin          Detector
                                Amplitude      Factor
           (MHz)                                                 (dBμV)          (dB)         (PK/Ave./QP)
                                 (dBμV)         (dB)
           0.158000               50.0           19.8             65.6              15.6           QP
           0.514000               38.7           19.8             56.0              17.3           QP
           1.130000               52.0           19.8             56.0              4.0            QP
           1.598000               51.0           19.9             56.0              5.0            QP
           2.414000               47.4           19.9             56.0              8.6            QP
           3.782000               41.6           20.0             56.0              14.4           QP
           0.158000               35.8           19.8             55.6              19.8          Ave.
           0.514000               30.9           19.8             46.0              15.1          Ave.
           1.130000               40.6           19.8             46.0              5.4           Ave.
           1.598000               39.6           19.9             46.0              6.4           Ave.
           2.414000               37.8           19.9             46.0              8.2           Ave.
           3.782000               32.4           20.0             46.0              13.6          Ave.




FCC Part 15B, Class B                                                                                   Page 11 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)                                       Report No.: RSZ181225006-00

     AC 120V/60 Hz, Neutral



                         90


                         80


                         70

                                                                                                           QP
                         60
          Level in dBu




                                                                                                          AV
                         50


                         40


                         30


                         20


                         10


                         0
                         150k   300 400 500   800 1M        2M     3M     4M 5M 6     8 10M         20M    30M
                                                        Frequency in Hz



                                Corrected     Correction
         Frequency                                             Limit            Margin            Detector
                                Amplitude      Factor
           (MHz)                                              (dBμV)             (dB)           (PK/Ave./QP)
                                 (dBμV)         (dB)
          0.154000                49.7           19.8            65.8               16.1             QP
          0.558000                37.3           19.7            56.0               18.7             QP
          1.154000                55.5           19.8            56.0               0.5              QP
          1.506000                53.9           19.9            56.0               2.1              QP
          2.330000                47.4           19.9            56.0               8.6              QP
          4.226000                40.5           20.0            56.0               15.5             QP
          0.154000                36.2           19.8            55.8               19.6            Ave.
          0.558000                30.0           19.7            46.0               16              Ave.
          1.154000                44.0           19.8            46.0               2.0             Ave.
          1.506000                41.6           19.9            46.0               4.4             Ave.
          2.330000                40.0           19.9            46.0               6.0             Ave.
          4.226000                32.1           20.0            46.0               13.9            Ave.




FCC Part 15B, Class B                                                                                     Page 12 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)                                     Report No.: RSZ181225006-00

50-pin Telco connectors:
     AC 120V/60 Hz, Line



                         90


                         80


                         70

                                                                                                         QP
                         60
          Level in dBu




                                                                                                        AV
                         50


                         40


                         30


                         20


                         10


                         0
                         150k   300 400 500   800 1M        2M     3M     4M 5M 6     8 10M       20M    30M
                                                        Frequency in Hz



                                Corrected     Correction
         Frequency                                                Limit         Margin          Detector
                                Amplitude      Factor
           (MHz)                                                 (dBμV)          (dB)         (PK/Ave./QP)
                                 (dBμV)         (dB)
           0.150000               49.4           19.8             66.0              16.6           QP
           0.298000               44.0           19.8             60.3              16.3           QP
           0.530000               42.9           19.8             56.0              13.1           QP
           1.186000               35.8           19.7             56.0              20.2           QP
           1.418000               30.8           19.8             56.0              25.2           QP
         23.130000                33.2           20.3             60.0              26.8           QP
           0.150000               36.8           19.8             56.0              19.2          Ave.
           0.298000               38.3           19.8             50.3              12.0          Ave.
           0.530000               36.9           19.8             46.0              9.1           Ave.
           1.186000               27.2           19.7             46.0              18.8          Ave.
           1.418000               23.7           19.8             46.0              22.3          Ave.
         23.130000                30.8           20.3             50.0              19.2          Ave.




FCC Part 15B, Class B                                                                                   Page 13 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)                                     Report No.: RSZ181225006-00

     AC 120V/60 Hz, Neutral



                         90


                         80


                         70

                                                                                                         QP
                         60
          Level in dBu




                                                                                                        AV
                         50


                         40


                         30


                         20


                         10


                         0
                         150k   300 400 500   800 1M        2M     3M     4M 5M 6     8 10M       20M    30M
                                                        Frequency in Hz



                                Corrected     Correction
         Frequency                                                Limit         Margin          Detector
                                Amplitude      Factor
           (MHz)                                                 (dBμV)          (dB)         (PK/Ave./QP)
                                 (dBμV)         (dB)
           0.150000               49.1           19.8             66.0              16.9           QP
           0.298000               44.4           19.8             60.3              15.9           QP
           0.522000               43.2           19.8             56.0              12.8           QP
           1.050000               37.6           19.8             56.0              18.4           QP
           1.386000               29.1           19.8             56.0              26.9           QP
         23.130000                34.5           20.3             60.0              25.5           QP
           0.150000               36.3           19.8             56.0              19.7          Ave.
           0.298000               38.7           19.8             50.3              11.6          Ave.
           0.522000               37.2           19.8             46.0              8.8           Ave.
           1.050000               30.2           19.8             46.0              15.8          Ave.
           1.386000               23.1           19.8             46.0              22.9          Ave.
         23.130000                32.3           20.3             50.0              17.7          Ave.

     Note:
     1) Correction Factor =LISN VDF (Voltage Division Factor) + Cable Loss + Transient Limiter Attenuation
     2) Corrected Amplitude = Reading + Correction Factor
     3) Margin = Limit – Corrected Amplitude

FCC Part 15B, Class B                                                                                   Page 14 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)                          Report No.: RSZ181225006-00

FCC §15.109 - RADIATED SPURIOUS EMISSIONS
Applicable Standard
FCC §15.109


EUT Setup
Below 1GHz:




Above 1GHz:




                                        1m or




The radiated emission tests were performed in the 3 meters chamber test site, using the setup accordance
with the ANSI C63.4-2014. The specification used was the FCC Part 15.109 Class B limits.


FCC Part 15B, Class B                                                                       Page 15 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)                                 Report No.: RSZ181225006-00

The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the
middle.

The spacing between the peripherals was 10 cm.


EMI Test Receiver Setup
The system was investigated from 30 MHz to 2 GHz.

During the radiated emission test, the EMI test receiver was set with the following configurations:

          Frequency Range              RBW             Video B/W           IF B/W          Measurment

         30 MHz – 1000 MHz           100 kHz            300 kHz            120 kHz             QP
                                      1MHz               3 MHz                 /               PK
             Above 1 GHz
                                      1MHz                10 Hz                /               Ave.


Test Procedure
Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.
All data was recorded in the Quasi-peak detector mode from 30 MHz to 1 GHz and PK and average
detector modes for frequencies above 1 GHz.

Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:
        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain
The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7 dB means the emission is 7 dB below the limit. The equation for margin
calculation is as follows:
        Margin = Limit – Corrected Amplitude

Test Results Summary
According to the data in the following table, the EUT complied with the FCC §15.109 Class B,

Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level is in compliance with the limit if
                                            Lm + U(Lm) ≤ Llim + Ucispr
In BACL, U(Lm) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.




FCC Part 15B, Class B                                                                             Page 16 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ181225006-00

Test Data
     Environmental Conditions

              Temperature:              25 ℃
         Relative Humidity:             52 %
             ATM Pressure:            101.0 kPa

      The testing was performed by Andy Yu on 2019-01-16 and Leo Huang on 2019-01-23.

     EUT Operation Mode: Full load




FCC Part 15B, Class B                                                                       Page 17 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)                                                        Report No.: RSZ181225006-00

     RJ11 Port:
     30 MHz~1 GHz:




                              80



                              70



                              60
             Level in dBuV/




                              50                                                         FCC Part 15 Class B Electric Field Strength QP



                              40



                              30



                              20



                              10



                               0
                               30M             50    60      80   100M               200         300      400   500         800    1G
                                                                             Frequency in Hz



                                   Corrected        Antenna                    Turntable       Correction
     Frequency                                                    Antenna                                         Limit       Margin
                                   Amplitude         height                     position        Factor
       (MHz)                                                      Polarity                                      (dBμV/m)       (dB)
                                   (dBμV/m)           (cm)                      (degree)        (dB/m)
     48.583125                       25.0            130.0           V            71.0            -19.0           40.00         15.0
     60.192000                       27.12           130.0           V           320.0            -20.2           40.00         12.88
     66.223000                       30.05           107.0           V            78.0            -20.5           40.00         9.95
     85.353875                       31.35           123.0           V           274.0            -19.5           40.00         8.65
     86.505375                       30.38           116.0           V            81.0            -19.4           40.00         9.62
     953.424000                      31.56           274.0           H           255.0             9.7            46.00         14.44




FCC Part 15B, Class B                                                                                                       Page 18 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)                     Report No.: RSZ181225006-00


    1 GHz – 2 GHz:

                        Receiver            Rx Antenna Corrected Corrected    FCC Part 15B
  Frequency                       Turntable
                                                        Factor Amplitude
    (MHz)      Reading             Degree Height Polar
                       PK/QP/Ave.                       (dB/m) (dBuV/m) Limit        Margin
               (dBμV)                       (m) (H / V)                    (dBuV/m)   (dB)
   1243.54      44.31         PK         360         1.2   H   -3.66   40.65     74        33.35
   1243.54      29.43         Ave.       360         1.2   H   -3.66   25.77     54        28.23
   1243.54      43.16         PK         231         1.5   V   -3.66   39.50     74        34.50
   1243.54      28.48         Ave.       231         1.5   V   -3.66   24.82     54        29.18
   1977.96      46.15         PK         137         1.8   H   -1.60   44.55     74        29.45
   1977.96      30.00         Ave.       137         1.8   H   -1.60   28.40     54        25.60
   1977.96      44.31         PK         323         2.1   V   -1.60   42.71     74        31.29
   1977.96      29.83         Ave.       323         2.1   V   -1.60   28.23     54        25.77




FCC Part 15B, Class B                                                                 Page 19 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)              Report No.: RSZ181225006-00

                                            Horizontal – Peak




                        74dBuV




                                             Vertical - Peak




                        74dBuV




FCC Part 15B, Class B                                                          Page 20 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)               Report No.: RSZ181225006-00

                                          Horizontal – Average




                        54dBuV




                                            Vertical - Average




                        54dBuV




FCC Part 15B, Class B                                                           Page 21 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)                                                   Report No.: RSZ181225006-00


     50-pin Telco connectors:
     30 MHz~1 GHz:




                             80



                             70



                             60
                                                                               FCC Part 15 Class B Electric Field Strength QP-3m

                             50
            Level in dBμV/




                             40



                             30



                             20



                             10



                             0
                             30M              50    60      80 100M              200         300     400   500        800   1G
                                                                         Frequency in Hz



                                  Corrected        Antenna                 Turntable       Correction
     Frequency                                                Antenna                                        Limit     Margin
                                  Amplitude         height                  position        Factor
       (MHz)                                                  Polarity                                     (dBμV/m)     (dB)
                                  (dBμV/m)           (cm)                   (degree)        (dB/m)
     38.964250                      32.24           104.0        V            61.0           -13.1          40.00       7.76
     47.810375                      29.39           109.0        V           357.0           -18.6          40.00       10.61
     85.509500                      29.33           107.0        V           290.0           -19.5          40.00       10.67
     86.029750                      27.02           109.0        V             0.0           -19.4          40.00       12.98
     837.542375                     29.31           260.0        V           176.0            5.7           46.00       16.69
     890.531750                     26.21           280.0        V            21.0            4.7           46.00       19.79




FCC Part 15B, Class B                                                                                                 Page 22 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ181225006-00

     1 GHz – 2GHz:

                         Receiver            Rx Antenna Corrected Corrected    FCC Part 15B
  Frequency                        Turntable
                                                         Factor Amplitude
    (MHz)       Reading             Degree Height Polar
                        PK/QP/Ave.                       (dB/m) (dBuV/m) Limit        Margin
                (dBμV)                       (m) (H / V)                    (dBuV/m)   (dB)
    1354.26      44.47         PK           219      2.1     H       -2.36   42.11     74        31.89
    1354.26      29.37         Ave.         219      2.1     H       -2.36   27.01     54        26.99
    1354.26      43.49         PK           305      1.5     V       -2.36   41.13     74        32.87
    1354.26      28.61         Ave.         305      1.5     V       -2.36   26.25     54        27.75
    1987.96      45.62         PK           167      1.6     H       -1.50   44.12     74        29.88
    1987.96      29.97         Ave.         167      1.6     H       -1.50   28.47     54        25.53
    1987.96      44.28         PK           161      1.5     V       -1.50   42.78     74        31.22
    1987.96      28.46         Ave.         161      1.5     V       -1.50   26.96     54        27.04

Note:
1) Correction Factor=Antenna factor (RX) + cable loss – amplifier factor
2) Corrected Amplitude = Correction Factor + Reading
3) Margin = Limit - Corrected Amplitude




FCC Part 15B, Class B                                                                       Page 23 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)              Report No.: RSZ181225006-00



                                            Horizontal – Peak




                        74dBuV




                                             Vertical - Peak




                        74dBuV




FCC Part 15B, Class B                                                          Page 24 of 25


 Bay Area Compliance Laboratories Corp. (Shenzhen)               Report No.: RSZ181225006-00

                                          Horizontal – Average




                        54dBuV




                                            Vertical - Average




                        54dBuV




                                  ***** END OF REPORT *****

FCC Part 15B, Class B                                                           Page 25 of 25



Document Created: 2019-03-14 15:01:44
Document Modified: 2019-03-14 15:01:44

© 2024 FCC.report