Test Report_JBP

FCC ID: YZZGXV3380

Test Report

Download: PDF
FCCID_4316526

                                                                                                  REPORT No.:SZ19040167E01




                                          TEST REPORT

                                 APPLICANT                               : Grandstream Networks,Inc.

                                 PRODUCT NAME                            : IP Multimedia Phone

                                 MODEL NAME                              : GXV3380

                                 BRAND NAME                              : GRANDSTREAM

                                 STANDARD(S)                             : 47 CFR Part 15 Subpart B

                                 FCC ID                                  : YZZGXV3380

                                 RECEIPT DATE                            : 2019-04-12

                                 TEST DATE                               : 2019-05-30 to 2019-06-06

                                 ISSUE DATE                              : 2019-06-10




                                                                  Edited by:
                                                                                               Zeng Jianqing (Rapporteur)


                                                                  Approved by:
                                                                                               Andy Yeh(Technical Director)



NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the
company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for
validation and information confirmed at our website.


 MORLAB
                         SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                      Tel: 86-755-36698555   Fax: 86-755-36698525
                         FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China      Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                                Page 1 of 20


                                                                                           REPORT No.:SZ19040167E01


                                                         DIRECTORY
1. Technical Information········································································································ 3
1.1. Applicant and Manufacturer Information····································································· 3
1.2. Equipment Under Test (EUT) Description ··································································· 3
2. Test Results ························································································································ 5
2.1. Applied Reference Documents ····················································································· 5
2.2. EUT Setup and Operating Conditions ·········································································· 6
3. 47 CFR Part 15B Requirements ······················································································· 7
3.1. Conducted Emission ······································································································ 7
3.2. Radiated Disturbance ··································································································· 11
Annex A Test Uncertainty ··································································································· 18
Annex B Testing Laboratory Information ········································································· 19




                                                               Change History
           Version                                  Date                                     Reason for change
              1.0                             2019-06-10                                             First edition




MORLAB
                     SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                     FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                     Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                         Page 2 of 20


                                                                                       REPORT No.:SZ19040167E01

1. Technical Information
Note: Provide by applicant

1.1. Applicant and Manufacturer Information

 Applicant:                             Grandstream Networks,Inc.
 Applicant Address:                     126 Brookline Ave., 3rd Floor Boston, MA 02215, USA
 Manufacturer:                          Grandstream Networks,Inc.
 Manufacturer Address:                  126 Brookline Ave., 3rd Floor Boston, MA 02215, USA


1.2. Equipment Under Test (EUT) Description

 EUT Type:                     IP Multimedia Phone
 Serial No:                    (N/A, marked #1 by test site)
 Hardware Version:             V1.6
 Software Version:             1.0.0.10
 Frequency Range:              Bluetooth: 2402 MHz ~ 2480 MHz
                               802.11b/g/n-20: 2412 MHz ~ 2462 MHz
                               802.11a/ac/n: 5180 MHz ~ 5240 MHz; 5260 MHz ~ 5320 MHz;
                               5500 MHz ~ 5700 MHz;5745MHz ~ 5825 MHz;
 Ancillary                     AC Adapter 1
 Equipment:                    Brand Name:                      FRECOM
                               Model No.:                       F18W8-120150SPAUY
                               Serial No:                       (N/A, marked #1 by test site)
                               Rated Input:                     100-240V             50/60Hz 0.6A
                               Rated Output:                    12.0V 1.5A
                               Manufacturer:                    Shenzhen Frecom Electronics Co., Ltd.
                               AC Adapter 2
                               Brand Name:                      SUNLIGHT
                               Model No.:                       H18US1200150A
                               Serial No.:                      (N/A, marked #1 by test site)
                               Rated Input:                     100-240V             50/60Hz 0.8A
                               Rated Output:                    12.0V 1.5A
                               Manufacturer:                    Shenzhen Sunlight Electronic Technology Co., Ltd.
                               HDMI Type1:
                               Brand Name:                      CE-LINK




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                     Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China     Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                     Page 3 of 20


                                                                                     REPORT No.:SZ19040167E01

                               Model No.:                       T04130-0002
                               Manufacturer:                    Hinen Electronics (ShenZhen) Co., Ltd
                               HDMI Type2:
                               Brand Name:                      ZONG
                               Model No.:                       HDMI-30-1
                               Manufacturer:                    ZONG Cable Technology Co.,Ltd.
Note:
1. The product provides two adapters, which are shipped randomly. Both of the two adaptors were

   tested, only the worst test result(Adapter2) were recorded in the test report.

2. The product provides two HDMI lines, which are shipped randomly.

3. For a more detailed description, please refer to specification or user’s manual supplied by the

   applicant and/or manufacturer.




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 4 of 20


                                                                                      REPORT No.:SZ19040167E01

2. Test Results
2.1. Applied Reference Documents
The objective of the report is to perform testing according to 47 CFR Part 15 Subpart B:

         No.   Identity                                                   Document Title
         1     47 CFR Part 15                                             Radio Frequency Devices

Test detailed items/section required by FCC rules and results are as below:

     No.     Section         Description                             Test Date        Test Engineer              Result
     1       15.107          Conducted Emission                      2019.06.06       Li Zihao                   PASS
     2       15.109          Radiated Emission                       2019.05.30       Li Zihao                   PASS

NOTE: The tests were performed according to the method of measurements prescribed in ANSI
C63.4-2014.




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page 5 of 20


                                                                                      REPORT No.:SZ19040167E01

2.2. EUT Setup and Operating Conditions

Test Item
Radiated Emission
Mode 1      : EUT+ADAPTER(sunlight)+ HDMI in(for DELL NB) + HDMI out (for SONY TV)
             +Mouse+Earphone+8G TF Card+RJ45 LINK
Mode 2       EUT+ADAPTER(frecom)+ HDMI in(for DELL NB) + HDMI out (for SONY TV)
             +Mouse+Earphone+8G TF Card+RJ45 LINK
Mode 3       EUT+ADAPTER(sunlight)+ HDMI in(for DELL NB) + HDMI out (for SONY TV)
             +Mouse+Earphone+8G TF Card +POE LINK
Conducted Emission
Mode 1      : EUT+ADAPTER(sunlight)+ HDMI in(for DELL NB) + HDMI out (for SONY TV)
              +Mouse+Earphone+8G TF Card+RJ45 LINK
Mode 2        EUT+ADAPTER(frecom)+ HDMI in(for DELL NB) + HDMI out (for SONY TV)
              +Mouse+Earphone+8G TF Card+RJ45 LINK
Mode 3        EUT+ADAPTER(sunlight)+ HDMI in(for DELL NB) + HDMI out (for SONY TV)
              +Mouse+Earphone+8G TF Card +POE LINK
Remark:
The above test modes in boldface were the worst cases of conducted emission, radiated emission
tests; only the test data of these modes was reported.

During the measurement, the environmental conditions were within the listed ranges:

 Temperature (°C):                                                        15 - 35
 Relative Humidity (%):                                                   30 - 60
 Atmospheric Pressure (kPa):                                              86 - 106




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page 6 of 20


                                                                                          REPORT No.:SZ19040167E01


3.        47 CFR Part 15B Requirements
3.1. Conducted Emission
3.1.1.    Requirement
According to FCC section 15.107, the radio frequency voltage that is conducted back onto the AC
power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the
following table, as measured using a 50µH/50Ω line impedance stabilization network (LISN).

   Frequency range                                                          Conducted Limit (dBµV)
        (MHz)                                            Quasi-peak                                              Average
         0.15 - 0.50                                        66 to 56                                             56 to 46
          0.50 - 5                                               56                                                 46
           5 - 30                                                60                                                 50
     NOTE:
     a) The limit subjects to the Class B digital device.
     b) The lower limit shall apply at the band edges.
     c) The limit decreases linearly with the logarithm of the frequency in the range 0.15 -
     0.50MHz.


3.1.2.    Test Setup

Please refer to Annex A for the photographs of the Test Configuration.




MORLAB
                    SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555    Fax: 86-755-36698525
                    FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                    Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn    E-mail: service@morlab.cn

                                                                                                                                         Page 7 of 20


                                                                                      REPORT No.:SZ19040167E01

The EUT is placed on a 0.8m high insulating table, which stands on the grounded conducting floor,
and keeps 0.4m away from the grounded conducting wall. The EUT is connected to the power
mains through a LISN which provides 50Ω/50µH of coupling impedance for the measuring
instrument. A Pulse Limiter is used to protect the measuring instrument. The factors of the whole
test system are calibrated to correct the reading.

The power strip or extension cord has been investigated to make sure that the LISN integrity in
maintained with respect to the impedance characteristics as prescribed in ANSI C63.4-2014 at
Clause 4.3.


3.1.3.   Test Result

The maximum conducted interference is searched using Peak (PK), Quasi-peak (QP) and Average
(AV) detectors; the emission levels more than the AV and QP limits, and that have narrow margins
from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase
and N phase lines of the power mains connected to the EUT are performed. All test modes are
considered, refer to recorded points and plots below.




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page 8 of 20


                                                                                      REPORT No.:SZ19040167E01

A. Test Plot and Suspicious Points:




                                                           (Plot A:L Phase)




        Fre.        Emission Level (dBµV)                                     Limit (dBµV)
 NO.                                                                                                         Power-line            Verdict
       (MHz)        Quai-peak                 Average                Quai-peak        Average
  1    0.1993           52.63                    39.70                    63.64          53.64                                        PASS
  2    0.2488           47.38                    35.84                    61.80          51.80                                        PASS
  3    0.4603           45.36                    30.82                    56.69          46.69                                        PASS
  4    1.4415           44.22                    36.64                    56.00          46.00                  Line                  PASS
  5    1.7085           46.28                    33.33                    56.00          46.00                                        PASS
  6    1.9169           46.97                    36.65                    56.00          46.00                                        PASS
  7    3.2863           43.46                    32.18                    56.00          46.00                                        PASS




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555     Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                      Page 9 of 20


                                                                                      REPORT No.:SZ19040167E01




                                                         (Plot B: N Phase)




        Fre.         Emission Level (dBµV)                                    Limit (dBµV)
 NO.                                                                                                         Power-line            Verdict
       (MHz)         Quai-peak                Average                Quai-peak        Average
  1    0.1904            52.18                   42.00                    64.02          54.02                                        PASS
  2    0.4429            46.18                   32.63                    57.01          47.01                                        PASS
  3    0.8290            47.98                   34.35                    56.00          46.00                                        PASS
                                                                                                              Neutral
  4    1.0312            48.57                   35.55                    56.00          46.00                                        PASS
  5    3.3198            42.78                   30.89                    56.00          46.00                                        PASS
  6    10.6311           44.29                   36.55                    60.00          50.00                                        PASS




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555     Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                      Page 10 of 20


                                                                                      REPORT No.:SZ19040167E01

3.2. Radiated Disturbance

3.2.1. Requirement

According to FCC section 15.109 (a), the field strength of radiated emissions from unintentional
radiators at a distance of 3 meters shall not exceed the following values:

              Frequency                 Field Strength Limitation at 3m Measurement Dist
             range (MHz)                              (µV/m)                                  (dBµV/m)
              30.0 - 88.0                                100                                  20log 100
             88.0 - 216.0                                150                                  20log 150
            216.0 - 960.0                                200                                  20log 200
             Above 960.0                                 500                                  20log 500

As shown in FCC section 15.35(b), for frequencies above 1000MHz, the field strength limits are
based on average detector. When average radiated emission measurements are specified in this
part, including emission measurements below 1000MHz, there also is a limit on the radio
frequency emissions, as measured using instrumentation with a peak detector function,
corresponding to 20dB above the maximum permitted average limit for the frequency being
investigated unless a different peak emission limit is otherwise specified in the rules.

Note:

1)   The tighter limit shall apply at the boundary between two frequency range.
2)   Limitation expressed in dBµV/m is calculated by 20log Emission Level(µV/m).


3.2.2. Frequency range of measurement

According to 15.33(b)(1), the frequency range of radiated measurement for the EUT is listed in the
following table:




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page 11 of 20


                                                                                     REPORT No.:SZ19040167E01

3.2.3. Test Setup

1)   For radiated emissions from 30MHz to1GHz




2)   For radiated emissions above 1GHz




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 12 of 20


                                                                                      REPORT No.:SZ19040167E01

The test is performed in a 3m Semi-Anechoic Chamber; the antenna factor, cable loss and so on of
the site (factors) is calculated to correct the reading. The EUT is placed on a 0.8m high insulating
Turn Table, and keeps 3m away from the Test Antenna, which is mounted onavariable-height
antenna master tower.

For the test Antenna:

In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) and Horn Test
Antenna (above 1GHz) are used. Test Antenna is 3m away from the EUT. Test Antenna height is
varied from 1m to 4m above the ground to determine the maximum value of the field strength. The
emission levels at both horizontal and vertical polarizations should be tested.


3.2.4.   Test Result

The maximum radiated emission is searched using PK, QP and AV detectors; the emission levels
more than the limits, and that have narrow margins from the limits will be re-measured with AV and
QP detectors. Both the vertical and the horizontal polarizations of the Test Antenna are considered
to perform the tests. All test modes are considered, refer to recorded points and plots below.

The amplitude of emissions which (6GHz-30GHz) are attenuated more than 20 dB below the
permissible value need not be reported.

Note: All radiated emission tests were performed in X, Y, Z axis direction, and only the worst axis
test condition was recorded in this test report.




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page 13 of 20


                                                                                      REPORT No.:SZ19040167E01




                                         (Plot A: ANT-Vertical,30MHz - 1GHz)




         Fre.              Pk               QP                AV           Limit-PK   Limit-QP           Limit-AV
 No.                                                                                                                     ANT          Verdict
         MHz           dBµV/m           dBµV/m            dBµV/m            dBµV/m    dBµV/m             dBµV/m
 1     30.0051           41.58             35.27             N.A.              N.A.     40.00                N.A.           V         PASS
 2     37.6289           38.27             33.68             N.A.              N.A.     40.00                N.A.           V         PASS
 3     144.5746          38.04              N.A.             N.A.              N.A.     43.50                N.A.           V         PASS
 4     279.5395          32.76              N.A.             N.A.              N.A.     46.00                N.A.           V         PASS
 5     599.9853          43.46             40.69             N.A.              N.A.     46.00                N.A.           V         PASS
 6     864.0641          40.81              N.A.             N.A.              N.A.     46.00                N.A.           V         PASS




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555     Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                      Page 14 of 20


                                                                                      REPORT No.:SZ19040167E01




                                          (Plot A: ANT-Vertical,1GHz - 6GHz)




         Fre.              Pk               QP                AV           Limit-PK   Limit-QP           Limit-AV
 No.                                                                                                                     ANT          Verdict
         MHz           dBµV/m           dBµV/m            dBµV/m            dBµV/m    dBµV/m             dBµV/m
 1     1600.1200         49.71              N.A.             N.A.             74.00      N.A.                54.00          V         PASS
 2     1996.1992         48.83              N.A.             N.A.             74.00      N.A.                54.00          V         PASS
 3     2137.2274         43.12              N.A.             N.A.             74.00      N.A.                54.00          V         PASS
 4     2510.3021         47.33              N.A.             N.A.             74.00      N.A.                54.00          V         PASS
 5     2884.3452         53.46              N.A.            35.93             74.00      N.A.                54.00          V         PASS
 6     3199.4399         49.72              N.A.             N.A.             74.00      N.A.                54.00          V         PASS
 7     4146.6293         49.18              N.A.             N.A.             74.00      N.A.                54.00          V         PASS




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555     Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                      Page 15 of 20


                                                                                      REPORT No.:SZ19040167E01




                                      (Plot B:ANT- Horizontal, 30MHz - 1GHz)




         Fre.              Pk               QP                AV           Limit-PK   Limit-QP          Limit-AV
 No.                                                                                                                     ANT          Verdict
         MHz          dBµV/m            dBµV/m           dBµV/m            dBµV/m     dBµV/m             dBµV/m
 1     35.8258           33.15             N.A.             N.A.              N.A.      40.00                N.A.          H          PASS
 2     238.7588          35.20             N.A.             N.A.              N.A.      46.00                N.A.          H          PASS
 3     445.5756          34.69             N.A.             N.A.              N.A.      46.00                N.A.          H          PASS
 4     581.5115          42.30             N.A.             N.A.              N.A.      46.00                N.A.          H          PASS
 5     612.6021          43.98            34.88             N.A.              N.A.      46.00                N.A.          H          PASS
 6     864.0641          41.15             N.A.             N.A.              N.A.      46.00                N.A.          H          PASS




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555     Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                      Page 16 of 20


                                                                                      REPORT No.:SZ19040167E01




                                       (Plot B:ANT- Horizontal, 1GHz - 6GHz)




         Fre.              Pk               QP                AV           Limit-PK   Limit-QP          Limit-AV
 No.                                                                                                                     ANT          Verdict
         MHz          dBµV/m            dBµV/m           dBµV/m            dBµV/m     dBµV/m             dBµV/m
 1     1120.0240         45.58             N.A.             N.A.             74.00       N.A.                54.00         H          PASS
 2     1600.1200         46.10             N.A.             N.A.             74.00       N.A.                54.00         H          PASS
 3     2884.2891         54.07             N.A.            33.76             74.00       N.A.                54.00         H          PASS
 4     3199.4399         48.88             N.A.             N.A.             74.00       N.A.                54.00         H          PASS
 5     4146.6003         54.67             N.A.            43.47             74.00       N.A.                54.00         H          PASS
 6     5785.9572         50.85             N.A.             N.A.             74.00       N.A.                54.00         H          PASS




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555     Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                      Page 17 of 20


                                                                                    REPORT No.:SZ19040167E01

Annex A Test Uncertainty
The uncertainty is calculated using the methods suggested in the "Guide to the Expression of
Uncertainty in Measurement" (GUM) published by ISO.

Uncertainty of Conducted Emission Measurement

 Measuring Uncertainty for 9kHz-150kHz                                                   ±4.1 dB
 a Level of Confidence of 150kHz-30MHz                                                   ±3.7dB
 95%(U=2Uc(y))

Uncertainty of Radiated Emission Measurement

 Measuring Uncertainty for 30MHz-200MHz                                                  ±5.06dB
 a Level of Confidence of 200MHz-1000MHz                                                 ±5.24dB
 95%(U=2Uc(y))             1GHz-6GHz                                                     ±5.18dB
                                      6GHz-18GHz                                         ±5.48dB




MORLAB
              SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                  Page 18 of 20


                                                                                     REPORT No.:SZ19040167E01

Annex B Testing Laboratory Information
1. Identification of the Responsible Testing Laboratory

 Laboratory Name:                             Shenzhen Morlab Communications Technology Co., Ltd.
                                              Morlab Laboratory
 Laboratory Address:                          FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                              Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                              Province, P. R. China
 Telephone:                                   +86 755 36698555
 Facsimile:                                   +86 755 36698525

2. Identification of the Responsible Testing Location

                                               Shenzhen Morlab Communications Technology Co., Ltd.
 Name:
                                               Morlab Laboratory
                                               FL.3, Building A, FeiYang Science Park, No.8 LongChang
 Address:                                      Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                               Province, P. R. China

3. Accreditation Certificate

 Accredited Testing                            The FCC designation number is CN1192.
 Laboratory:                                   Test firm registration number is 226174.
                                               (Shenzhen Morlab Communications Technology Co., Ltd.)

4. Test Software Utilized

              Model                                      Version Number                                     Producer
            JS32-RE                                        Version 2.0.2.0                                  Tonscend
        TS+ -[ JS32-CE]                                     Version2.5.0.0                                  Tonscend




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 19 of 20


                                                                                             REPORT No.:SZ19040167E01

5. Test Equipments Utilized

  Description           Manufacturer                        Model                       Serial No.           Cal. Date            Due. Date
   MXE EMI
                              Agilent                      N9038A                  MY54130016               2018.08.04           2019.08.03
   Receiver
  Test Receiver                 R&S                          ESPI                        101052             2018.08.04           2019.08.03
      LISN               Schwarzbeck                    NSLK 8127                        812744             2019.05.08           2020.05.07
  Pulse Limiter
                               VTSD                         9561D                         9537              2019.05.08           2020.05.07
     (20dB)
 Test Antenna -
                         Schwarzbeck                    VULB 9163                       9163-519            2019.05.08           2020.05.07
     Bi-Log
 Test Antenna -
                         Schwarzbeck                  BBHA 9120D                          1774              2019.05.08           2020.05.07
      Horn
   Radiated
                                                      S020180L320
  Disturbance                  rflight                                              61171/61172             2018.07.12           2019.07.11
                                                           3
  Preamplifier
   Radiated
                                                      S10M100L38
  Disturbance                  rflight                                                   46732              2018.07.12           2019.07.11
                                                          02
  Preamplifier
 Semi-Anechoic
                                CRT                     9m*6m*6m                           N/A              2017.01.12           2020.01.11
   Chamber

                                                           END OF REPORT




MORLAB
                  SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                        Tel: 86-755-36698555   Fax: 86-755-36698525
                  FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                  Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China        Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                           Page 20 of 20