Quick Installation Guide

FCC ID: YZZGSC3510

Users Manual

Download: PDF
FCCID_4350940

    Grandstream Networks, Inc.

         126 Brookline Ave, 3rd Floor
           Boston, MA 02215. USA
           Tel : +1 (617) 566 - 9300
          Fax: +1 (617) 249 - 1987

           www.grandstream.com




                                                                 GSC3510
     In all EU member states, operation of 5150
     - 5350 MHz is restricted to indoor use only.   SIP Two-Way Intercom Speaker

For Warranty and RMA information, please visit
           www.grandstream.com                               Quick Installation Guide


EN
                                                             OVERVIEW
     The GSC3510 is not pre-configured to support or         GSC3510 is a two-way, full-duplex SIP intercom speaker featuring one 100Mbps
     make emergency calls to any type of hospital,           Ethernet port with PoE/PoE+, integrated dual-band 2.4G/5G Wi-Fi, integrated
     law enforcement agency, medical care unit               Bluetooth, 3 directional microphones with Multichannel Microphone Array De-
                                                             sign (MMAD), high fidelity 8W speaker and a multi-purpose input port support-
     (“Emergency Service(s)”) or any other kind of           ing a wide range of peripherals. The state-of-art microphone array and Hi-Fi
     Emergency Service. You must make additional             speaker deliver full-duplex and full-band audio with pickup distance up to 4.2
     arrangements to access Emergency Services. It           meters. The built-in whitelist and blacklist features enables easy filtering of un-
                                                             wanted calls from the Internet. Its modern industrial design and rich features
     is your responsibility to purchase SIP-compliant
                                                             make it ideal for classrooms, hospitals, apartments, dormitories and much more.
     Internet telephone service, properly configure
     the GSC3510 to use that service, and periodical-        PRECAUTIONS
     ly test your configuration to confirm that it works     • Do not attempt to open, disassemble, or modify the device.
     as you expect. It is also your responsibility to pur-   • Do not expose this device to temperatures outside range of 0 °C to 40 °C in op-
                                                             eration and -10 °C to 60 °C in storage.
     chase traditional wireless or landline telephone
                                                             • Do not expose the GSC3510 to environments outside of the following humidity
     services to access Emergency Services.                  range: 10-90% RH (non-condensing).
                                                             • Do not power cycle your GSC3510 during system boot up or firmware upgrade.
     GRANDSTREAM DOES NOT PROVIDE CON-                       You may corrupt firmware images and cause the unit to malfunction.

     NECTIONS TO EMERGENCY SERVICES VIA THE                  PACKAGE CONTENTS
     GSC3510. NEITHER GRANDSTREAM NOR ITS OF-
     FICES, EMPLOYEES OR AFFILIATES MAY BE HELD LI-
     ABLE FOR ANY CLAIM, DAMAGE, OR LOSS, AND
     YOU HEREBY WAIVE ANY AND ALL SUCH CLAIMS
     OR CAUSES OF ACTION ARISING FROM OR RE-
     LATING TO YOUR INABILITY TO USE THE GSC3510                      GSC3510                 Metal Bracket             Plastic Bracket

     TO CONTACT EMERGENCY SERVICES, AND YOUR
     FAILURE TO MAKE ADDITIONAL ARRANGEMENTS
     TO ACCESS EMERGENCY SERVICES IN ACCOR-                    3x Screw (PA 3.5 x 20)           3x M3 NUT             3x Plastic Expansion Bolt
     DANCE WITH THE IMMEDIATELY PRECEDING
     PARAGRAPH.
                                                                           1x Quick Installation Guide    3x Screw (PM 3 x 50)
                                                                           1x GPL Statement
                             ~1~                                                                    ~2~


GSC3510 PORTS                                                                        Ceiling Mount
                                                                                     1. Put the ceiling mounting (metal bracket)
                                                                                        in the ceiling’s center and mark the posi-
                                                                                        tion of the three screw holes.
                                                                                     2. Drill a round hole with a diameter of
                                                                                        18mm for Ethernet cable. The distance                               35mm
                                                                                        between its center and the highlighted
                                                                                                                                            1, 2
 Port                  Description
                                                                                        hole on the plastic bracket should be
 Reset                 Factory reset button. Press for 10 seconds to reset factory
                                                                                        35mm.
                       default settings.                                                                                                                   M3 nut
                                                                                     3. Fix the plastic and metal brackets on the     Plastic
 NET/PoE               Ethernet RJ45 port (10/100Mbps) supporting PoE/PoE+.                                                           bracket
                                                                                        ceiling with flat-head screws and lock-
 2-Pin port            2-pin multi-purpose input port.(switch action)                   nuts.Then place an Ethernet cable pass
                                                                                        through the 18mm-round hole.
HARDWARE INSTALLATION                                                                4. Align the position line on device’s back
                                                                                        cover with the positioning slot.               Metal
GSC3510 can be mounted on the wall or ceiling. Please refer to the following                                                           bracket
steps for the appropriate installation.                                                                                                                    M3.0x50
                                                                                     5. Rotate the device clockwise untill it is
                                                                                        locked on the right postion.                          3            screw
Wall Mount

1. Locate the equipment holder on the desired po-                                                                           Positionining
   sition with arrow up. Drill three holes on the wall                                                                      slot
   referring to the positions of holes on the metal                                                                                                           Lock
   bracket.
                                                                              1
2. Fix the metal bracket on the wall by expansion                                          5                                            4
   screws.

3. Align the position line on device’s back cover                                    POWERING AND CONNECTING THE GSC3510
   with the positioning slot.
                                                                                     GSC3510 can be powered on using PoE/PoE+ switch or PoE injector using
4. Rotate the device clockwise untill it is locked on                                following steps:
   the right postion.                                                                - Step 1: Plug a RJ45 Ethernet cable into the network port of the GSC3510.
                                                                              2
                                                                                     - Step 2: Plug the other end into the power over Ethernet (PoE) switch or PoE
                                                                                     injector.




                                                               Lock                                       Network Port

                                                               Positionining slot                                             RJ45 Ethernet Cable to Power over Eth-
                       4                                 3                                                                    ernet (PoE) Switch or PoE injector.

                                       ~3~                                                                                 ~4~


ACCESSING THE CONFIGURATION INTERFACE
A computer connected to the same network as the GSC3510 can discover and          FCC Caution:
access its configuration interface using its MAC address :

1. Locate the MAC address on the MAC tag of the unit, which is on the underside
of the device, or on the package.

2. From a computer connected to same network as the GSC3510, type in the fol-
lowing address using the GSC3510’s MAC address on your browser:
https://gsc_<mac>.local

Example: if a GSC3510 has the MAC address 00:0B:82:11:22:33, this unit can
be accessed by typing https://gsc_000b82112233.local on the browser.




For more information, please download the GSC3510 User Manual from:
http://www.grandstream.com/support




                                     ~5~                                                         ~6~



Document Created: 2019-07-10 20:02:02
Document Modified: 2019-07-10 20:02:02

© 2024 FCC.report