RF Exposure

FCC ID: YZZGSC3510

RF Exposure Info

Download: PDF
FCCID_4350914

Bay Area Compliance Laboratories Corp. (Shenzhen)                                  Report No.: RSZ190401001-00B

FCC §15.247 (i) & §1.1307 (b) (1) & §2.1091- MAXIMUM PERMISSIBLE
EXPOSURE (MPE)
Applicable Standard
According to subpart 15.247 (i) and subpart 1.1307 (b)(1), 2.1091 systems operating under the provisions
of this section shall be operated in a manner that ensures the public is not exposed to RF energy level in
excess of the communication guidelines.

                                Limits for General Population/Uncontrolled Exposure

                               Limits for General Population/Uncontrolled Exposure
             Frequency           Electric Field     Magnetic Field        Power            Averaging
               Range                Strength           Strength          Density             Time
               (MHz)                 (V/m)              (A/m)           (mW/cm2)           (Minutes)
               0.3-1.34               614                   1.63         *(100)                 30
               1.34-30               824/f                 2.19/f       *(180/f2)               30
                30-300                27.5                 0.073             0.2                30
               300-1500                   /                  /           f/1500                 30
           1500-100,000                   /                  /               1.0                30

f = frequency in MHz
* = Plane-wave equivalent power density


Result
Calculated Formulary:

Predication of MPE limit at a given distance

                                                            PG
                                                      S=
                                                           4R 2
S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW).
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain
    factor, is normally numeric gain.
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)


                                              Tune-up Conducted      Evaluation         Power
   Frequency              Antenna Gain                                                               MPE Limit
                                                    Power             Distance         Density
     (MHz)                                                                                           (mW/cm2)
                    (dBi)       (numeric)     (dBm)     (mW)           (cm)           (mW/cm2)
   2402-2480          5            3.16        1.5           1.41       20              0.001             1
   2412-2462          5            3.16        23.5         223.87      20              0.141             1

Note: To maintain compliance with the FCC’s RF exposure guidelines, place the equipment at least 20cm
from nearby persons.

Result: Compliance