Test Report

FCC ID: YZZ-GXW4248

Test Report

Download: PDF
FCCID_4201224

                                 FCC PART 15B, CLASS B
                                              TEST REPORT

                                                             For


                              Grandstream Networks, Inc.
                              126 Brookline Ave, 3rd Floor Boston, MA 02215, USA



                                        FCC ID: YZZ-GXW4248


              Report Type:                                      Product Type:
              Original Report                                  Analog IP Gateway



                   Report Number:           RSZ181225012-00


                        Report Date:        2019-02-20

                                            Xiangguang Kong

                       Reviewed By:         Engineer

                       Prepared By:         Bay Area Compliance Laboratories Corp. (Shenzhen)
                                            6/F., West Wing, Third Phase of Wanli Industrial
                                            Building, Shihua Road, Futian Free Trade Zone,
                                            Shenzhen, Guangdong, China
                                            Tel: +86-755-33320018
                                            Fax: +86-755-33320008
                                            www.baclcorp.com.cn




Note: This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any
agency of the Federal Government. * This report may contain data that are not covered by the A2LA accreditation and are marked
with an asterisk “*”.
      The information marked # is provided by the applicant, the laboratory is not responsible for its authenticity.


  Bay Area Compliance Laboratories Corp. (Shenzhen)                                                                          Report No.: RSZ181225012-00




                                                       TABLE OF CONTENTS


GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 MEASUREMENT UNCERTAINTY ....................................................................................................................................3
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  SPECIAL ACCESSORIES .................................................................................................................................................5
  EQUIPMENT MODIFICATIONS .......................................................................................................................................5
  SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................5
  EXTERNAL I/O CABLE..................................................................................................................................................5
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................7

TEST EQUIPMENT LIST ...........................................................................................................................................8
FCC §15.107 – AC LINE CONDUCTED EMISSIONS .............................................................................................9
  APPLICABLE STANDARD ..............................................................................................................................................9
  EUT SETUP ..................................................................................................................................................................9
  EMI TEST RECEIVER SETUP .........................................................................................................................................9
  TEST PROCEDURE ........................................................................................................................................................9
  CORRECTED FACTOR & MARGIN CALCULATION .......................................................................................................10
  TEST RESULTS SUMMARY ..........................................................................................................................................10
  TEST DATA ................................................................................................................................................................10
FCC §15.109 - RADIATED SPURIOUS EMISSIONS ............................................................................................13
  APPLICABLE STANDARD ............................................................................................................................................13
  EUT SETUP ................................................................................................................................................................13
  EMI TEST RECEIVER SETUP .......................................................................................................................................14
  TEST PROCEDURE ......................................................................................................................................................14
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................14
  TEST RESULTS SUMMARY ..........................................................................................................................................14
  TEST DATA ................................................................................................................................................................15




FCC Part 15B, Class B                                                                                                                                  Page 2 of 19


 Bay Area Compliance Laboratories Corp. (Shenzhen)                                 Report No.: RSZ181225012-00

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)

                 Product                   Analog IP Gateway
              Tested Model                 GXW4248
             Voltage Range                 DC 24V from adapter.
                Measure                    44.0 cm (L) * 25.5 cm (W) *4.4 cm (H)
       Highest operating frequency         400 MHz
               Date of Test                Jan 23, 2019~ Feb 15, 2019
          Sample serial number             181225012
             Received date                 2018-12-25
           Sample/EUT Status               Good condition
                                           Model: FSP150-AAAN2
           Adapter information             Input: AC 100-240V, 50/60Hz, 2A
                                           Output: DC 24V, 6.25A


Objective
This test report is prepared on behalf of Grandstream Networks, Inc. in accordance with Part 2-Subpart J,
Part 15-Subparts A, B of the Federal Communication Commissions rules.

The objective of the manufacturer is to determine the compliance of the EUT with FCC Part 15 B.


Related Submittal(s)/Grant(s)
No Related Submittal(s)/Grant(s).


Test Methodology
All measurements contained in this report were conducted with ANSI C63.4-2014, American National
Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and
Electronic Equipment in the range of 9 kHz to 40 GHz.

All emissions measurement was performed at Bay Area Compliance Laboratories Corp. (Shenzhen). The
radiated testing was performed at an antenna-to-EUT distance of 3 meters.


Measurement Uncertainty

                        Parameter                                   uncertainty
                 Conducted Emissions                                  ±1.95dB

            Emissions,           Below 1GHz                           ±4.75dB
             radiated            Above 1GHz                           ±4.88dB

Note: Otherwise required by the applicant or Product Regulations, Decision Rule in this report did not consider the
uncertainty.



FCC Part 15B, Class B                                                                                Page 3 of 19


 Bay Area Compliance Laboratories Corp. (Shenzhen)                         Report No.: RSZ181225012-00

Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Shenzhen) to collect test data is located
on the 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road, Futian Free Trade Zone,
Shenzhen, Guangdong, China.

The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public
Access Link (PAL) database, FCC Registration No.: 342867, the FCC Designation No.: CN1221.

The test site has been registered with ISED Canada under ISED Canada Registration Number 3062B.




FCC Part 15B, Class B                                                                      Page 4 of 19


 Bay Area Compliance Laboratories Corp. (Shenzhen)                          Report No.: RSZ181225012-00

SYSTEM TEST CONFIGURATION
Description of Test Configuration
The system was configured for testing in a manufacturer testing fashion.


EUT Exercise Software
No test software was used


Special Accessories
No special accessory.


Equipment Modifications
No modification was made to the EUT tested.


Support Equipment List and Details


       Manufacturer          Description               Model                   Serial Number

         ASKPCB             FXS test tool             E239218                      N/A
          Sagem                   Router         F@ST 1704N                    3c81d839027c


External I/O Cable

              Cable Description               Length (m)           From/Port                   To

      Unshielded detachable AC cable                 1.0            Adapter               LISN
    Unshielded un-detachable DC cable            1.78               Adapter                EUT
     Unshielded detachable RJ45 cable            10.0                 EUT                 Router




FCC Part 15B, Class B                                                                         Page 5 of 19


          Bay Area Compliance Laboratories Corp. (Shenzhen)                 Report No.: RSZ181225012-00

         Block Diagram of Test Setup
         For conducted emission:




                                                                          EUT          Adapter               LISN
                                                              FXS test-
                                                                                10cm
                                                                Tool

Router




                                                                                                 1.0 meter
                         Non-Conductive Table
                         80 cm above Ground Plane

                                                         1.5 meters




         FCC Part 15B, Class B                                                               Page 6 of 19


 Bay Area Compliance Laboratories Corp. (Shenzhen)                      Report No.: RSZ181225012-00

SUMMARY OF TEST RESULTS

                FCC Rules                     Description of Test              Results

                  §15.107                AC Line Conducted Emissions         Compliance

                  §15.109                 Radiated Spurious Emissions        Compliance




FCC Part 15B, Class B                                                                    Page 7 of 19


 Bay Area Compliance Laboratories Corp. (Shenzhen)                                Report No.: RSZ181225012-00

TEST EQUIPMENT LIST

                                                                     Serial        Calibration     Calibration
     Manufacturer            Description            Model
                                                                    Number            Date          Due Date
                                       AC Line Conducted Emission Test
   Rohde & Schwarz       EMI Test Receiver          ESCS30          100176         2018-07-11      2019-07-11
                                                                 3560.6650.12-
   Rohde & Schwarz              LISN                ENV216                         2018-12-21      2019-12-21
                                                                  101613-Yb
   Rohde & Schwarz        Transient Limiter         ESH3Z2         DE25985         2018-11-12      2019-05-12

   Rohde & Schwarz        CE Test software          EMC 32          V8.53.0           NCR              NCR
                         Conducted Emission                      UF A210B-1-
       Unknown                                       78652                         2018-11-12      2019-05-12
                               Cable                             0720-504504

                                               Radiated Emission Test
      A.H. System           Horn Antenna          SAS-200/571           135        2018-09-01      2021-08-31
   Rohde & Schwarz         Signal Analyzer           FSEM         845987/005       2018-06-23      2019-06-23
     Sunol Sciences      Broadband Antenna            JB1         A040904-1        2017-12-22      2020-12-21
     COM-POWER              Pre-amplifier           PA-122          181919         2018-11-12      2019-05-12
   Sonoma instrument          Amplifier              310N           186238         2018-11-12      2019-05-12
   Rohde & Schwarz        EMI Test Receiver          ESCI           101120         2019-01-11      2020-01-11
       Ducommun                                    UFA147A-       MFR64639
                              RF Cable                                             2018-07-11      2021-07-10
      technologies                                2362-100100     231029-003

       Ducommun
                              RF Cable              104PEA        218124002        2018-11-12      2019-05-12
      technologies
       Ducommun
                              RF Cable              RG-214               1         2018-11-12      2019-05-12
      technologies
       Ducommun
                              RF Cable              RG-214               2         2018-11-12      2019-05-12
      technologies

   Rohde & Schwarz        Auto test software        EMC 32           V9.10            NCR              NCR

   Rohde & Schwarz        Auto test software        EMC 32           V9.10            NCR              NCR



* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
been performed in accordance to requirements that traceable to National Primary Standards and International System
of Units (SI).




FCC Part 15B, Class B                                                                              Page 8 of 19


 Bay Area Compliance Laboratories Corp. (Shenzhen)                          Report No.: RSZ181225012-00

FCC §15.107 – AC LINE CONDUCTED EMISSIONS
Applicable Standard
According to FCC §15.107


EUT Setup




The measurement procedure of EUT setup is according with per ANSI C63.4-2014. The related limit was
specified in FCC Part 15.107 Class B.

The spacing between the peripherals was 10 cm.

EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                              Frequency Range                      IF B/W
                              150 kHz – 30 MHz                      9 kHz


Test Procedure
During the conducted emission test, the host PC was connected to the first LISN and the other relevant
equipments were conncected to the second LISN.
Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.

FCC Part 15B, Class B                                                                       Page 9 of 19


 Bay Area Compliance Laboratories Corp. (Shenzhen)                               Report No.: RSZ181225012-00

Corrected Factor & Margin Calculation
The Corrected factor is calculated by adding LISN/ISN VDF (Voltage Division Factor), Cable Loss and
Transient Limiter Attenuation. The basic equation is as follows:
      Correction Factor = LISN VDF + Cable Loss + Transient Limiter Attenuation
The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7 dB means the emission is 7 dB below the limit. The equation for margin
calculation is as follows:
      Margin = Limit – Corrected Amplitude

Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Part 15.107,

Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level is in compliance with the limit if

                                            Lm + U(Lm) ≤ Llim + Ucispr

In BACL., U(Lm) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.

Test Data
     Environmental Conditions

               Temperature:                25 ℃
          Relative Humidity:               50 %
              ATM Pressure:              101.0 kPa

      The testing was performed by Joson Xiao on 2019-02-15.




FCC Part 15B, Class B                                                                             Page 10 of 19


 Bay Area Compliance Laboratories Corp. (Shenzhen)                                 Report No.: RSZ181225012-00


      EUT Operation Mode: Full load

     AC 120V/60 Hz, Line


                         90


                         80


                         70

                                                                                                    QP
                         60
          Level in dBμ




                                                                                                     AV
                         50


                         40


                         30


                         20


                         10


                         0
                         150k   300 400 500   800 1M        2M     3M 4M 5M 6     8 10M       20M    30M
                                                        Frequency in Hz



                                Corrected     Correction
         Frequency                                                Limit     Margin          Detector
                                Amplitude      Factor
           (MHz)                                                 (dBμV)      (dB)         (PK/Ave./QP)
                                 (dBμV)         (dB)
           0.340810               42.7           19.7             59.2          16.5           QP
           2.181210               42.1           19.9             56.0          13.9           QP
           4.875930               39.9           20.1             56.0          16.1           QP
           6.047610               43.1           20.1             60.0          16.9           QP
           6.517130               48.6           20.1             60.0          11.4           QP
           7.069510               46.9           20.1             60.0          13.1           QP
           0.340810               37.6           19.7             49.2          11.6          Ave.
           2.181210               30.2           19.9             46.0          15.8          Ave.
           4.875930               32.0           20.1             46.0          14.0          Ave.
           6.047610               35.7           20.1             50.0          14.3          Ave.
           6.517130               46.1           20.1             50.0          3.9           Ave.
           7.069510               44.0           20.1             50.0          6.0           Ave.




FCC Part 15B, Class B                                                                               Page 11 of 19


 Bay Area Compliance Laboratories Corp. (Shenzhen)                                 Report No.: RSZ181225012-00

     AC 120V/60 Hz, Neutral



                         90


                         80


                         70

                                                                                                     QP
                         60
          Level in dBμ




                                                                                                     AV
                         50


                         40


                         30


                         20


                         10


                         0
                         150k   300 400 500   800 1M        2M     3M 4M 5M 6     8 10M       20M    30M
                                                        Frequency in Hz



                                Corrected     Correction
         Frequency                                             Limit        Margin          Detector
                                Amplitude      Factor
           (MHz)                                              (dBμV)         (dB)         (PK/Ave./QP)
                                 (dBμV)         (dB)
          5.234530                41.5           20.1            60.0           18.5           QP
          5.909350                43.6           20.1            60.0           16.4           QP
          6.705470                43.9           20.1            60.0           16.1           QP
          7.312290                42.8           20.1            60.0           17.2           QP
          7.855170                41.0           20.1            60.0           19.0           QP
          8.719230                40.4           20.1            60.0           19.6           QP
          5.234530                36.2           20.1            50.0           13.8          Ave.
          5.909350                37.1           20.1            50.0           12.9          Ave.
          6.705470                37.1           20.1            50.0           12.9          Ave.
          7.312290                37.0           20.1            50.0           13.0          Ave.
          7.855170                32.9           20.1            50.0           17.1          Ave.
          8.719230                35.4           20.1            50.0           14.6          Ave.

     Note:
     1) Correction Factor =LISN VDF (Voltage Division Factor) + Cable Loss + Transient Limiter Attenuation
     2) Corrected Amplitude = Reading + Correction Factor
     3) Margin = Limit – Corrected Amplitude

FCC Part 15B, Class B                                                                               Page 12 of 19


 Bay Area Compliance Laboratories Corp. (Shenzhen)                          Report No.: RSZ181225012-00

FCC §15.109 - RADIATED SPURIOUS EMISSIONS
Applicable Standard
FCC §15.109


EUT Setup
Below 1GHz:




Above 1GHz:




                                        1m or




The radiated emission tests were performed in the 3 meters chamber test site, using the setup accordance
with the ANSI C63.4-2014. The specification used was the FCC Part 15.109 Class B limits.


FCC Part 15B, Class B                                                                       Page 13 of 19


 Bay Area Compliance Laboratories Corp. (Shenzhen)                                 Report No.: RSZ181225012-00

The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the
middle.

The spacing between the peripherals was 10 cm.


EMI Test Receiver Setup
The system was investigated from 30 MHz to 2 GHz.

During the radiated emission test, the EMI test receiver was set with the following configurations:

          Frequency Range              RBW             Video B/W           IF B/W          Measurment

         30 MHz – 1000 MHz           100 kHz            300 kHz            120 kHz             QP
                                      1MHz               3 MHz                 /               PK
             Above 1 GHz
                                      1MHz                10 Hz                /               Ave.


Test Procedure
Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.
All data was recorded in the Quasi-peak detector mode from 30 MHz to 1 GHz and PK and average
detector modes for frequencies above 1 GHz.

Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:
        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain
The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7 dB means the emission is 7 dB below the limit. The equation for margin
calculation is as follows:
        Margin = Limit – Corrected Amplitude

Test Results Summary
According to the data in the following table, the EUT complied with the FCC §15.109 Class B,

Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level is in compliance with the limit if
                                            Lm + U(Lm) ≤ Llim + Ucispr
In BACL, U(Lm) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.




FCC Part 15B, Class B                                                                             Page 14 of 19


 Bay Area Compliance Laboratories Corp. (Shenzhen)                          Report No.: RSZ181225012-00

Test Data
     Environmental Conditions

              Temperature:              25 ℃
         Relative Humidity:             50 %
             ATM Pressure:            101.0 kPa

      The testing was performed by Andy Yu and Leo Huang on 2019-01-23and 2019-02-15.

     EUT Operation Mode: Full load




FCC Part 15B, Class B                                                                      Page 15 of 19


 Bay Area Compliance Laboratories Corp. (Shenzhen)                                                   Report No.: RSZ181225012-00

     30 MHz~1 GHz:




                             80



                             70



                             60
                                                                               FCC Part 15 Class B Electric Field Strength QP-3m

                             50
            Level in dBμV/




                             40



                             30



                             20



                             10



                             0
                             30M              50    60      80 100M              200         300     400   500        800   1G
                                                                         Frequency in Hz



                                  Corrected        Antenna                 Turntable       Correction
     Frequency                                                Antenna                                        Limit     Margin
                                  Amplitude         height                  position        Factor
       (MHz)                                                  Polarity                                     (dBμV/m)     (dB)
                                  (dBμV/m)           (cm)                   (degree)        (dB/m)
     35.589625                      36.19           107.0        V           356.0           -10.9          40.00       3.81
     41.812875                      38.42           113.0        V             0.0           -15.1          40.00       1.58
     43.769500                      39.35           100.0        V             0.0           -16.4          40.00       0.65
     53.398625                      38.82           107.0        V            51.0           -19.8          40.00       1.18
     62.507375                      30.90           143.0        V           144.0           -20.3          40.00       9.10
     903.670125                     25.35           140.0        H            19.0            4.6           46.00       20.65




FCC Part 15B, Class B                                                                                                 Page 16 of 19


 Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ181225012-00

     1 GHz – 2 GHz:

                         Receiver            Rx Antenna Corrected Corrected    FCC Part 15B
  Frequency                        Turntable
                                                         Factor Amplitude
    (MHz)       Reading             Degree Height Polar
                        PK/QP/Ave.                       (dB/m) (dBuV/m) Limit        Margin
                (dBμV)                       (m) (H / V)                    (dBuV/m)   (dB)
    1453.62      44.32         PK           335      2.4     H       -2.10   42.22     74        31.78
    1453.62      29.62         Ave.         335      2.4     H       -2.10   27.52     54        26.48
    1453.62      43.31         PK           244      1.2     V       -2.10   41.21     74        32.79
    1453.62      28.61         Ave.         244      1.2     V       -2.10   26.51     54        27.49
    1991.98      45.62         PK           322      2.4     H       -1.50   44.12     74        29.88
    1991.98      29.91         Ave.         322      2.4     H       -1.50   28.41     54        25.59
    1991.98      44.54         PK           247      1.6     V       -1.50   43.04     74        30.96
    1991.98      29.93         Ave.         247      1.6     V       -1.50   28.43     54        25.57

Note:
1) Correction Factor=Antenna factor (RX) + cable loss – amplifier factor
2) Corrected Amplitude = Correction Factor + Reading
3) Margin = Limit - Corrected Amplitude




FCC Part 15B, Class B                                                                       Page 17 of 19


 Bay Area Compliance Laboratories Corp. (Shenzhen)              Report No.: RSZ181225012-00

                                            Pre-scan for peak

                                               Horizontal




                        74dBuV




                                                 Vertical




                        74dBuV




FCC Part 15B, Class B                                                          Page 18 of 19


 Bay Area Compliance Laboratories Corp. (Shenzhen)               Report No.: RSZ181225012-00

                                          Horizontal – Average




                        54dBuV




                                            Vertical - Average




                        54dBuV




                                  ***** END OF REPORT *****

FCC Part 15B, Class B                                                           Page 19 of 19



Document Created: 2019-03-14 13:26:11
Document Modified: 2019-03-14 13:26:11

© 2024 FCC.report