Novii
Wireless Patch
System
Improved Maternal
Fetal Monitoring


The Monica Novii Wireless
Patch System provides the
opportunity to enhance
your current monitoring
experience.


It connects with your
maternal/fetal monitor1 and
the data flows seamlessly to
your existing surveillance
and archival system.



Enhanced monitoring
for difficult to monitor
patients

The Monica Novii monitors
fetal heart rate, maternal heart
rate and uterine activity, all
with a single patch. It is an
effective solution for monitoring
high BMI patients (Ref 1, 2) and
                                    “We found Monica
minimizes the risk of maternal/
fetal heart rate confusion (Ref
3, 4). In addition, the Patch
                                     to perform excellently
requires no repositioning (Ref 4,
8) and the cable-free system
                                     in very obese women
                                     (35>BMI<60)”
keeps the work environment
clear and safe allowing for
easier monitoring during some
clinical procedures.                Prof W Cohen,
                                    University of Arizona College of Medicine, Tucson USA
Patient satisfaction

The single-patient use Novii
Patch is a completely belt-free,
wireless solution. It allows for
greater freedom of movement
during labour and a more
comfortable experience for the
patient (Ref 7, 8).


                                                                                   Your Fetal Monitor

                                                                                   The Novii System connects seamlessly
                                                                                   with your monitor1. The Novii Pod,
                                                                                   a small signal-processing and
                                                                                   transmission device, connects effortlessly
                                                                                   using magnets to the ‘peel and stick’
                                                                                   Novii Patch shown below. The Novii
                                                                                   Pod communicates via Bluetooth – no
                                                                                   cables – no belts – no transducers– with
                                                                                   the Novii Interface display device shown
                                                                                   on the left, which connects to your fetal
                                                                                   monitor transducer inputs.




                                                Expanding
                                              maternal/fetal
                                                monitoring                         Monitoring High BMI Patients

                                                                                   Picking up consistent, reliable fetal
                                                                                   heart rate and uterine activity can be
                                                                                   challenging on high BMI patients.
                                                                                   Monica Novii monitors the electrical
                                                                                   signals on the patient’s abdomen.
                                                                                   The electrical signals are minimally
                                                                                   effected by adipose tissue and therefore,
                                                                                   the quality of the monitoring is not
                                                                                   compromised by high BMI. Studies,
                                                                                   recruiting women up to a BMI of 60,
                                                                                   have shown minimal loss in FHR and
                                                                                   UA performance as the BMI increases.
                                                                                   (Ref 1, Ref 2).




1
    Contact Monica Healthcare or their authorized representative for a full list


                                             Accuracy                                              Mobility and Freedom

                                             Monica Novii uses the abdominal fECG                  With no cables, belts or transducers
                                             and mECG wave shape to uniquely                       and no re-positioning, the Novii System
                                             identify and separate the maternal and                allows real freedom and mobility which
                                             fetal heart rates. The fetal QRS complex              can help the birthing process (Ref 6). The
                                             has a width less than 50% of the maternal             system’s line of sight range of 30m (90
                                             QRS. This and other differences between               feet) allows the patient to move about
                                             the maternal and fetal ECG allow the                  the room freely.
                                             Monica Novii to be reasonably certain
                                             that the true FHR has been detected                   With no transducer leads between the
                                             (Ref 3, Ref 4).   You can be confident that           patient and the fetal monitor, the working
                                             you are monitoring the fetal heart even               environment around the bed is kept clear
                                             in the most challenging circumstances                 and safe. The patient is free to get up
                                             shown below. In addition, the uterine                 without asking for assistance.
                                             EMG is used to extract the UA trace and
                                             has been shown in a clinical study to be
                                             equivalent to TOCO UA (Ref 5).



                                       210

                                       180

                                       150

                                       120

                                       90

                                       60




                                     18:50


      Scalp FHR                              Risk Mitigation
      Monica FHR
      SpO2 MHR
                                             In a high BMI patient, finding the ideal
      Monica UA                              transducer placement can be difficult.
      IUPC UA                                Because the Novii uses electrical signals,
                                             it is not impacted by maternal weight.
This is data from the multi-centre
clinical trial (Ref 1) showing the           This translates into more reliable tracings           Waterproof
FSE FHR, IUPC UA and SpO2                    (Ref 1, Ref 2). In addition, the Novii’s ability to
MHR traces used to manage                                                                          The Monica Novii Patch and Pod,
                                             simultaneously monitor and differentiate
the patient. Superimposed are
                                             between the fetal and maternal heart rate             when connected, are rated for total
the simultaneously monitored
                                                                                                   water immersion to 1 meter, so they can
Monica UA and FHR. The Monica                can significantly reduce the likelihood of
                                                                                                   be left in place during a bath or shower.
UA and FHR trace was not seen                maternal/fetal confusion.
by the Doctors and Nurses
managing the patient.                                                                              Monitoring continuity cannot be
                                                                                                   guaranteed when the Novii Pod is totally
                                                                                                   immersed in water.


Patient Friendly                                 Workflow
and Convenient                                   Improvements

The Monica Novii is a comfortable                The Novii’s simple, ‘peel and stick’ design
alternative to transducers with belts,           eliminates the need to re-position
which can cause irritation for some              transducers. The single-patient-use patch
patients. The patch only needs to be             minimizes the risk of cross-contamination
placed once, which means that the                caused by inadequate cleaning. In
patient does not need to be disturbed            addition, the system’s ‘intelligent’
for repositioning, and since it is cordless,     automated set-up provides help and
the patient has greater flexibility in           support messages to optimize and
the room.                                        simplify operation. To prevent Pods
                                                 from being lost in operation, they are
                 Studies have shown (Ref 7,      non-white and the Interface will alert
                  8) that patient satisfaction   the user if a Pod is not returned to a
                  is likely to be higher when    charging bay after use.
                  monitored on the Novii
                   compared to traditional
                     transducers. It is light,
                       small and causes
                       minimal discomfort.




                                                 Long Inductions and Labours

                                                 The Novii Interface has two inductive
                                                 charging bays allowing two Pods
                                                 to be charged at the same time.
                                                 The Pod battery life is up to 11 hours,
                                                 with up to 2 hours recharging time.
                                                 Swapping Pods could not be simpler,
                                                 just remove and replace, ensuring
                                                 minimal trace loss and the ability to
                                                 offer continuity of monitoring over
                                                 extended periods.


References                                                                       About Monica Healthcare
High BMI:
Ref 1 – Cohen WR, Hayes-Gill B. Influence of maternal body mass index            Monica Healthcare is developing a series of innovative wearable
on accuracy and reliability of external fetal monitoring techniques.
Acta Obstet Gynecol Scand. 2014 Jun ; 93 (6) : 590-5.                            devices that uses wireless technologies to facilitate globally
Ref 2 – Graatsma EM, Miller J, Mulder EJ, Harman C, Baschat AA, Visser           accessible obstetric services in the home and hospital.
GH. Maternal body mass index does not affect performance of fetal
electrocardiography. Am J Perinatol. 2010 Aug ; 27 (7) : 573-7.

MHR/FHR Confusion:                                                               Monica Healthcare Ltd was formed in May 2005 and was the
Ref 3 – Cohen WR, Ommani S, Hassan S, Mirza FG, Solomon M, Brown
R, Schifrin BS, Himsworth JM, Hayes-Gill BR. Accuracy and reliability
                                                                                 culmination of 15 years of research at the School of Electrical and
of fetal heart rate monitoring using maternal abdominal surface                  Electronic Engineering and the School of Human Development
electrodes. Acta Obstet Gynecol Scand. 2012 Nov ; 91 (11) : 1306-13.
Ref 4 – Stampalija T, Signaroldi M, Mastroianni C, Rosti E, Signorelli
                                                                                 at The University of Nottingham, UK.
V, Casati D, Ferrazzi EM. Fetal and maternal heart rate confusion
during intra-partum monitoring: comparison of trans-abdominal fetal
electrocardiogram and Doppler telemetry.                                         The patented technology is based on the acquisition of electro-
J Matern Fetal Neonatal Med. 2012 Aug ; 25 (8) : 1517-20.
                                                                                 physiological signals that can be passively detected by electrodes
Monica UA Compares with IUPC:
Ref 5 – Hayes-Gill B, Hassan S, Mirza FG, Ommani S, Himsworth J,
                                                                                 positioned on the maternal abdomen. From these signals a
Solomon M, Brown R, Schifrin BS, Wayne R. Cohen WR. Accuracy                     number of parameters, fetal heart rate, maternal heart rate, uterine
and Reliability of Uterine Contraction Identification Using Abdominal
Surface Electrodes. Clinical Medicine Insights: Women’s Health 2012 : 5 65–75.   activity, maternal movements and parameters describing Fetal ECG
Mobility and Impact on Stage 1 of Labour:                                        morphology and RR intervals (for research only) can be extracted,
Ref 6 – Lawrence A, Lewis L, Hofmeyr GJ, Dowswell T, Styles C.
Maternal positions and mobility during first stage labour.
                                                                                 in real time and over an extended period of time.
Cochrane Database Syst Rev. 2009 Apr 15 ; (2) : CD003934.

Patient Satisfaction:                                                            Monica Healthcare is working with business partners to distribute
Ref 7 – Reinhard J, Hayes-Gill BR, Yi Q, Hatzmann H, Schiermeier
S. Comparison of non-invasive fetal electrocardiogram to Doppler                 and deliver professional solutions meeting the needs of modern
cardiotocogram during the 1st stage of labor.                                    obstetric care, risk management and patient satisfaction.
J Perinat Med. 2010 Mar ; 38 (2) : 179-85.

Ref 8 – Rauf Z, O’Brien E, Stampalija T, Ilioniu FP, Lavender T, Alfirevic Z.
Home Labour Induction with Retrievable Prostaglandin Pessary and
Continuous Telemetric Trans-Abdominal Fetal ECG Monitoring.
PLoS ONE 2011 6 (11) : e28129.



In the USA: US law restricts this device to sale by or on the order of a
physician for use in a clinical setting.

The Novii device is for use in singleton term intrapartum patients,
using surface electrodes on the maternal abdomen in a clinical setting.




                                                                                 0843
                                                                                 Part No: 107-TF-102-ENrevA
                                                                                 © Copyright 2015 Monica Healthcare Ltd
                                                                                 All rights reserved

                                                                                 Monica Healthcare reserves the right to make changes to the
                                                                                 features shown herein or discontinue the product described at
                                                                                 any time without notice or obligation and will not be liable for
                                                                                 any consequences resulting from the use of this document.




                                                                                 Monica Healthcare Limited                           Monica Healthcare Inc.
                                                                                 Unit 8, Interchange 25 Business Park,               3862 Brentview Place
                                                                                 Bostocks Lane,                                      Kennesaw
                                                                                 Nottingham                                          GA 30144
                                                                                 NG10 5QG UK                                         USA
                                                                                 Tel: +44 115 9496960                                Tel: +1 877 320 5174
Monica and Novii are registered trademarks of                                    E-mail: sales@monicahealthcare.com
Monica Healthcare in USA, EU, China and Japan                                    www.monicahealthcare.com



Document Created: 2016-05-23 16:30:12
Document Modified: 2016-05-23 16:30:12

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC