Test Report

FCC ID: YNIJAZWARES16106

Test Report

Download: PDF
FCCID_1967136

                                                                                                    Bay Area Compliance            Labs Corp.




                                           FCC PART 15.229

                                               TEST REPORT
                                                              For


                                           JAZWARES INC
                                       1067 Shotgun Road, Sunrise, FL 33326, USA




                                  FCC ID: YNIJAZWARES16106



             Report Type:                                        Product Type:

             Original Report                                     Walkic Talkie


                                                                                  &avlfl% kMg,
                 Test Engineer:         —_Rocky Kang



               Report Number:           —_RSZ130428832—00


                    Report Date:        2013—05—14


                                        Alvin Huang                               t.o )_é/+t MW/
                   Reviewed By:         _RF Leader

                   Prepared By:         Bay Area Compliance Laboratories Corp. (Shenzhen)
                                        6/F, the 3rd Phase of WanLi Industrial Building,
                                        ShiHua Road, FuTian Free Trade Zone
                                        Shenzhen, Guangdong, China
                                        Tel: +86—755—33320018
                                        Fax: +86—755—33320008
                                        www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the equipment described hercin. It may not be duplicated
or used in part without prior written consent from Bay Area Compliance Laboratories Corp.


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                                            Report No.: RSZ130428832-00




                                                       TABLE OF CONTENTS


GENERAL INFORMATION.......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S).............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 TEST FACILITY .............................................................................................................................................................3
SYSTEM TEST CONFIGURATION..........................................................................................................................4
  JUSTIFICATION .............................................................................................................................................................4
  EUT EXERCISE SOFTWARE ..........................................................................................................................................4
  EQUIPMENT MODIFICATIONS .......................................................................................................................................4
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................4
SUMMARY OF TEST RESULTS ...............................................................................................................................5
FCC §15.203 - ANTENNA REQUIREMENT.............................................................................................................6
  APPLICABLE STANDARD ..............................................................................................................................................6
  ANTENNA CONNECTED CONSTRUCTION ......................................................................................................................6
FCC §15.229, §15.205 & §15.209 - RADIATED EMISSIONS TEST .......................................................................7
  APPLICABLE STANDARD ..............................................................................................................................................7
  MEASUREMENT UNCERTAINTY ....................................................................................................................................7
  EUT SETUP ..................................................................................................................................................................7
  EMI TEST RECEIVER SETUP .........................................................................................................................................8
  CORRECTED AMPLITUDE & MARGIN CALCULATION ...................................................................................................8
  TEST EQUIPMENT LIST AND DETAILS ...........................................................................................................................8
  TEST RESULTS SUMMARY ............................................................................................................................................8
  TEST DATA ..................................................................................................................................................................9
FCC §15.229(G) - FREQUENCY STABILITY .........................................................................................................10
  APPLICABLE STANDARD ............................................................................................................................................10
  TEST PROCEDURE ......................................................................................................................................................10
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................10
  TEST DATA ................................................................................................................................................................10
FCC §15.215(F) - 20GB EMISSION BANDWIDTH TESTING ..............................................................................12
  REQUIREMENT ...........................................................................................................................................................12
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................12
  TEST PROCEDURE ......................................................................................................................................................12
  TEST DATA ................................................................................................................................................................12
PRODUCT SIMILARITY DECLARATION LETTER ..........................................................................................14




FCC Part 15.229                                                                                                                                         Page 2 of 14


Bay Area Compliance Laboratories Corp. (Shenzhen)                                Report No.: RSZ130428832-00

GENERAL INFORMATION
Product Description for Equipment Under Test (EUT)
The JAZWARES INC’s product, model number: 16106 (FCC ID: YNIJAZWARES16106) the “EUT” in this
report is a Walkie Talkie, the EUT is measured approximately: 20.7 cm (L) x 7.0 cm (W) x 6.8 cm (H),
rated with input voltage: DC 9V battery.

Note: The product Walkie Talkie, series model 13510, 17305, 16106, 13310 and 14555, they share the same PCB and
schematics, the differences among them are color and appearance, which was explained in the attached declaration
letter. And the model 16106 was selected to test.

* All measurement and test data in this report was gathered from production sample serial number: 13042801
(Assigned by BACL, Shenzhen). The EUT supplied by the applicant was received on 2013-04-28.


Objective
This Type approval report is prepared on behalf of JAZWARES INC in accordance with Part 2, Subpart J,
and Part 15, Subparts A, B and C of the Federal Communication Commissions rules.

The objective is to determine the compliance of the EUT with FCC rules, sec 15.203, 15.205, 15.209 and
15.229.


Related Submittal(s)/Grant(s)
No Related Submittals.


Test Methodology
All measurements contained in this report were conducted with ANSI C63.4-2009, American National
Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and
Electronic Equipment in the range of 9 kHz to 40 GHz.

All radiated and conducted emissions measurement was performed at Bay Area Compliance Lab Corp.
(Shenzhen). The radiated testing was performed at an antenna-to-EUT distance of 3 meters.


Test Facility
The test site used by Bay Area Compliance Laboratories Corp.(Shenzhen) to collect test data is located on
the 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen,
Guangdong, China.

Test site at Bay Area Compliance Laboratories Corp. (Shenzhen) has been fully described in reports
submitted to the Federal Communication Commission (FCC). The details of these reports have been
found to be in compliance with the requirements of Section 2.948 of the FCC Rules on December 06, 2010.
The facility also complies with the radiated and AC line conducted test site criteria set forth in ANSI
C63.4-2009.

The Federal Communications Commission has the reports on file and is listed under FCC Registration No.:
382179. The test site has been approved by the FCC for public use and is listed in the FCC Public Access
Link (PAL) database.



FCC Part 15.229                                                                                   Page 3 of 14


Bay Area Compliance Laboratories Corp. (Shenzhen)                             Report No.: RSZ130428832-00

SYSTEM TEST CONFIGURATION
Justification
The system was configured for testing in a typical fashion (as normally used by a typical user).


EUT Exercise Software
No exercise software was used.


Equipment Modifications
No modification on the EUT.


Block Diagram of Test Setup




                                                                                           1.0 Meter
                                                       EUT




                  Non-Conductive Table
                  80 cm above Ground Plane


                                                    1.5 Meter




FCC Part 15.229                                                                                        Page 4 of 14


Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ130428832-00

SUMMARY OF TEST RESULTS


              FCC Rules                          Description of Test                 Result

                  §15.203                       Antenna Requirement               Compliance
                  §15.207                   AC Line Conducted Emission           Not Applicable
                §15.229
                                               Radiated Emission Test             Compliance
            §15.209 §15.205
               §15.229(d)                        Frequency Stability              Compliance
               §15.215(c)                 20dB Emission Bandwidth Testing         Compliance

      Note: Not Applicable - EUT is battery operation only.




FCC Part 15.229                                                                               Page 5 of 14


Bay Area Compliance Laboratories Corp. (Shenzhen)                             Report No.: RSZ130428832-00

FCC §15.203 - ANTENNA REQUIREMENT
Applicable Standard
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with
the provisions of this section.


Antenna Connected Construction
The EUT has a molopole antenna arrangement, which was permanently attached, fulfill the requirement of
this section. Please refer to the internal photos.




FCC Part 15.229                                                                                Page 6 of 14


Bay Area Compliance Laboratories Corp. (Shenzhen)                             Report No.: RSZ130428832-00

FCC §15.229, §15.205 & §15.209 - RADIATED EMISSIONS TEST
Applicable Standard
As per FCC Part 15.229
(a) Unless operating pursuant to the provisions in § 15.231, the field strength of any emissions within this
    band shall not exceed 1,000 microvolts/meter at 3 meters.
(b) As an alternative to the limit in paragraph (a) of this section, perimeter protection systems may
    demonstrate compliance with the following: the field strength of any emissions within this band shall
    not exceed 500 microvolts/meter at 3 meters, as determined using measurement instrumentations
    employing an average detector. The provisions in § 15.35 for limiting peak emissions apply where
    compliance of these devices is demonstrated under this alternative emission limit.
(c) The field strength of any emissions appearing outside of this band shall not exceed the general
    radiated emission limits in § 15.209

Measurement Uncertainty
All measurements involve certain levels of uncertainties, especially in field of EMC. The factors
contributing to uncertainties are spectrum analyzer, cable loss, antenna factor calibration, antenna
directivity, antenna factor variation with height, antenna phase center variation, antenna factor frequency
interpolation, measurement distance variation, site imperfections, mismatch (average), and system
repeatability.
Based on CISPR 16-4-4, The Treatment of Uncertainty in EMC Measurements, the best estimate of the
uncertainty of a radiation emissions measurement at Bay Area Compliance Laboratories Corp. (Shenzhen)
is 4.0 dB.(k=2, 95% level of confidence), and the uncertainty will not be taken into consideration for all
the test data recorded in the report.


EUT Setup




The radiated emission tests were performed in the 3-meter chamber a test site, using the setup accordance
with the ANSI C63.4-2009. The specification used was the FCC Part Subpart C limits.

FCC Part 15.229                                                                                Page 7 of 14


Bay Area Compliance Laboratories Corp. (Shenzhen)                                 Report No.: RSZ130428832-00

EMI Test Receiver Setup
According to FCC Rules, 47 CFR 15.33, the EUT emissions were investigated up to 1000 MHz.

During the radiated emission test, the EMI test Receiver was set with the following configurations:

         Frequency Range              RBW              Video B/W            IF B/W            Detector
        30MHz – 1000 MHz             100 kHz            300 kHz             120kHz               QP


Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:
        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin = Limit – Corrected Amplitude


Test Equipment List and Details

                                                                     Serial        Calibration     Calibration
     Manufacturer            Description            Model
                                                                    Number            Date          Due Date
   Rohde & Schwarz        EMI Test Receiver          ESCI            101122         2012-08-08     2013-08-07
           HP                  Amplifier            8447E         1937A01046        2012-11-24     2013-11-23
     Sunol Sciences         Bi-log Antenna            JB1          A040904-2        2011-11-28     2014-11-27

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
 been performed in accordance to requirements that traceable to National Primary Standards and International
 System of Units (SI).


Test Results Summary
According to the data in the following table, the EUT complied with the FCC Part 15.209 with the worst
margin reading of:

                             2.76 dB at 40.685 MHz in the Vertical polarization




FCC Part 15.229                                                                                     Page 8 of 14


Bay Area Compliance Laboratories Corp. (Shenzhen)                             Report No.: RSZ130428832-00

Test Data
     Environmental Conditions

               Temperature:               25 ℃
        Relative Humidity:                50 
              ATM Pressure:             100.0 kPa

    The testing was performed by Rocky Kang on 2013-05-10.

    Test mode: Transmitting

1) Field Strength of Radiated Emissions (Fundamental)

       Frequency            Emissions                          Limits       Detector
                                                 H/V                                         Margin (dB)
         (MHz)             (dBuV/m)                          (dBuV/m)     (PK/QP/Ave)

         40.685               57.24              V              60           Ave.               2.76
         40.685               63.27              V              80            PK                16.73
         40.685               34.22              H              60           Ave.               25.78
         40.685               40.43              H              80            PK                39.57



2) Spurious Emission, up to 1000MHz:

                                              Rx Antenna       Corrected Corrected      FCC PDUW 15.229
  Frequency       Reading     Turntable
                                            Height   Polar      Factor   Amplitude      Limit     Margin
    (MHz)         (dBμV)       Degree
                                             (m)     (H/V)       (dB)    (dBμV/m)     (dBμV/m)      (dB)
    81.368         44.26          213         1.3      V        -19.76      24.5          40            15.5
    81.368         44.06          68          1.5      H        -19.76      24.3          40            15.7
    162.74         32.75          84          1.5      V        -14.05      18.7         43.5           24.8
    162.74         32.35          174         1.4      H        -14.05      18.3         43.5           25.2
    122.041        30.43          174         1.4      V        -13.03      17.4         43.5           26.1
    122.041        30.13          113         1.1      H        -13.03      17.1         43.5           26.4
    203.474         27.8          111         1.1      V         -12.7      15.1         43.5           28.4
    203.474         27.4          111         1.1      H         -12.7      14.7         43.5           28.8

Note:
Corrected Amplitude = Corrected Factor + Reading
Corrected Factor=Antenna factor (RX) + Cable loss – Amplifier Factor
Margin = Limit – Corr. Amplitude




FCC Part 15.229                                                                                 Page 9 of 14


Bay Area Compliance Laboratories Corp. (Shenzhen)                                 Report No.: RSZ130428832-00

FCC §15.229(d) - FREQUENCY STABILITY
Applicable Standard
The frequency tolerance of the carrier signal shall be maintained within ±0.01% of the operating frequency
over a temperature variation of −20 degrees to +50 degrees C at normal supply voltage, and for a variation
in the primary supply voltage from 85% to 115% of the rated supply voltage at a temperature of 20 degrees
C. For battery operated equipment, the equipment tests shall be performed using a new battery.


Test Procedure
Frequency Stability vs. Temperature: The equipment under test worked with a new battery, and rod
antenna was connected to a spectrum analyzer. The EUT was placed inside the temperature chamber.

After the temperature stabilized for approximately 20 minutes, the frequency output was recorded from the
Spectrum Analyzer.


Test Equipment List and Details

                                                                      Serial       Calibration     Calibration
     Manufacturer            Description             Model
                                                                     Number           Date          Due Date
   Rohde & Schwarz        EMI Test Receiver          ESCI            101122         2012-08-08     2013-08-07
                           Temperature &
         ESPEC                                     EL-10KA          09107726        2012-11-02     2013-11-01
                          Humidity Chamber

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
 been performed in accordance to requirements that traceable to National Primary Standards and International System
 of Units (SI).


Test Data
     Environmental Conditions

             Temperature:                25 ℃
        Relative Humidity:               50 
            ATM Pressure:              100.0 kPa

   The testing was performed by Rocky Kang on 2013-05-10.

   Test Mode: Transmitting

    Test Result: Pass




FCC Part 15.229                                                                                     Page 10 of 14


Bay Area Compliance Laboratories Corp. (Shenzhen)                     Report No.: RSZ130428832-00



                                                Measured
                           Temperature                        Frequency        Part 15.229
        Power Supply                            Frequency
                              (℃)                               Error            Limit
                                                  (MHz)
                                -20              40.6845      -0.0012%          ±0.01%
                                -10              40.6844      -0.0015%          ±0.01%
                                 0               40.6847      -0.0007%          ±0.01%
                                 10                 40.6846   -0.0009%          ±0.01%
           DC 9V
                                 20                 40.6849   -0.0002%          ±0.01%
                                 30                 40.6848   -0.0005%          ±0.01%
                                 40                 40.6847   -0.0007%          ±0.01%
                                 50                 40.6846   -0.0009%          ±0.01%

     Note: Centre frequency is 40.685 MHz




FCC Part 15.229                                                                      Page 11 of 14


Bay Area Compliance Laboratories Corp. (Shenzhen)                                 Report No.: RSZ130428832-00

FCC §15.215(c) - 20 dB EMISSION BANDWIDTH TESTING
Requirement
Per FCC §15.215 (c) Intentional radiators operating under the alternative provisions to the general emission
limits, as contained in §15.217 through 15.257 and in Subpart E of this part, must be designed to ensure
that the 20 dB bandwidth of the emission, or whatever bandwidth may otherwise be specified in the
specific rule section under which the equipment operates, is contained within the frequency band
designated in the rule section under which the equipment is operated. The requirement to contain the
designated bandwidth of the emission within the specified frequency band includes the effects from
frequency sweeping, frequency hopping and other modulation techniques that may be employed as well as
the frequency stability of the transmitter over expected variations in temperature and supply voltage. If a
frequency stability is not specified in the regulations, it is recommended that the fundamental emission be
kept within at least the central 80% of the permitted band in order to minimize the possibility of out-of-
band operation.


Test Equipment List and Details

                                                                      Serial       Calibration     Calibration
      Manufacturer             Description            Model
                                                                     Number           Date          Due Date
    Rohde & Schwarz          EMI Test Receiver         ESCI           101122        2012-08-08     2013-08-07
            HP                  Amplifier             8447E        1937A01046       2012-11-24     2013-11-23
      Sunol Sciences          Bilog Antenna            JB1          A040904-2       2011-11-28     2014-11-27

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
been performed in accordance to requirements that traceable to National Primary Standards and International System
of Units (SI).


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT without connection to measurement instrument. Turn on the EUT and connect it to
   measurement instrument. Then set it to any one convenient frequency within its operating range. Set a
   reference level on the measuring instrument equal to the highest peak value.
3. Measure the frequency difference of two frequencies that were attenuated 20 dB from the reference
   level. Record the frequency difference as the emission bandwidth.


Test Data
    Environmental Conditions

             Temperature:              25 ℃
        Relative Humidity:             50 
           ATM Pressure:             100.0 kPa

   The testing was performed by Rocky Kang on 2013-05-10.

   Test Mode: Transmitting

   Test Result: Pass
FCC Part 15.229                                                                                    Page 12 of 14


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                    Report No.: RSZ130428832-00


                                              20 dB Emission Bandwidth
                                                                   * RBW 10 kHz   Marker 1 [T1 ]
                                                                   * VBW 30 kHz             63.25 dBµV
                         Ref   87 dBµV        Att    10 dB          SWT 2.5 ms        40.685800000 MHz

                                                                                  ndB [T1]   20.00 dB
                         80                                                       BW 26.800000000 kHz
                                                                                  Temp 1 [T1 ndB]       B

                                                                                            43.58 dBµV
                  1 PK
                         70                                                           40.671400000 MHz
                  MAXH
                                                               1                  Temp 2 [T1 ndB]
                                                                                            43.50 dBµV
                         60
                                                                                      40.698200000 MHz TDF


                         50                                                                              PS
                                                T1                         T2

                         40



                         30                                                                              3DB
                                                                                                         AC


                         20



                         10



                         0



                         -10

                         Center 40.6856 MHz                  10 kHz/                      Span 100 kHz




                  EUT
                  Date: 10.MAY.2013      12:16:56




FCC Part 15.229                                                                                                     Page 13 of 14


Bay Area Compliance Laboratories Corp. (Shenzhen)              Report No.: RSZ130428832-00

PRODUCT SIMILARITY DECLARATION LETTER




                                   ***** END OF REPORT *****



FCC Part 15.229                                                               Page 14 of 14



Document Created: 2019-11-20 00:40:51
Document Modified: 2019-11-20 00:40:51

© 2024 FCC.report