RF Exposure

FCC ID: YMX-EC7502A

RF Exposure Info

Download: PDF
FCCID_4495030

                    FCC ID : YMX-EC7502A

Portable device
According to §15.247(e)(i) and §1.1307(b)(1), systems operating under the
provisions of this section shall be operated in a manner that ensures that the
public is not exposed to radio frequency energy level in excess of the
Commission’s guidelines.
According to KDB 447498 D01 General RF Exposure Guidance v06, section
4.3.1

The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test
separation distances ≤ 50 mm are determined by:

 [(max. power of channel, including tune-up tolerance, mW)/(min. test separation
distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity
SAR,16 where
    f(GHz) is the RF channel transmit frequency in GHz
    Power and distance are rounded to the nearest mW and mm before
calculation17
    The result is rounded to one decimal place for comparison
The test exclusions are applicable only when the minimum test separation
distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6
GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm
is applied to determine SAR test exclusion.


Antenna Gain = 2.0dBi

Worse case (8DPSK)

 Frequency     Output Power    Target power Target power Calculation     Threshold
   (MHz)          (dBm)           (dBm)        (mW)        Value          Value

    2402            3.45            3±1          2.512        0.779         3.0

Threshold at which no SAR required is ≤ 3.0 for 1-g SAR, Separation distance is
5mm.

Conclusion: No SAR is required.

SIMULTANEOUS TRANSMISSION EVALUATION
N/A



Document Created: 2019-11-05 06:04:50
Document Modified: 2019-11-05 06:04:50

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC