test report

FCC ID: YHXMPRFB-R

Test Report

Download: PDF
FCCID_1300978

                                                                     Report No.: TB-F107144




                            FCC PART 15.109

          MEASUREMENT AND TEST REPORT
                                       For

               EUT Name: Digital Meat Probe with RF monitor
                 Item No.: 23100111, 20100111, 20100311
                         FCC ID: YHXMPRFB-R
                     Serial No.: Not supplied by client




Prepared for     :   Masterbuilt Manufacturing, Inc.
Address          :   1 Masterbuilt Court • Columbus, Georgia 31907, USA

Prepared by      :   Shenzhen Toby Technology Co., Ltd.
Address          :   10/F., A Block, Jiada R & D Bldg., No.5 Songpingshan Road,
                     Science & Technology Park, Nanshan District, Shenzhen, China
Tel              :   0086-18925263335



                               Report Number      :    TB-F107144
                               Date of Test       :    May 31-June 02, 2010
                               Date of Report     :    June 03, 2010


                                                                                                                 Report No.: TB-F107144




                                                 TABLE OF CONTENTS

TEST REPORT DECLARATION........................................................................................................3
1.   GENERAL INFORMATION ....................................................................................................4
     1.1.   Product Description for Equipment Under Test (EUT) ....................................................4
     1.2.   Test Standards ...................................................................................................................4
     1.3.   Related Submittal(s)/Grant(s) ...........................................................................................4
     1.4.   Test Methodology .............................................................................................................5
     1.5.   Accessories Equipment List and Details...........................................................................5
     1.6.   EUT Cable List and Details ..............................................................................................5
     1.7.   Test Location ....................................................................................................................5
2.   SUMMARY OF TEST RESULTS.............................................................................................6
3.   §15.109(A) - RADIATED EMISSION.......................................................................................7
     3.1.   Measurement Uncertainty.................................................................................................7
     3.2.   Standard Applicable..........................................................................................................7
     3.3.   Test Equipment List and Details.......................................................................................7
     3.4.   Test Procedure ..................................................................................................................8
     3.5.   Corrected Amplitude & Margin Calculation ....................................................................8
     3.6.   Environmental Conditions ................................................................................................8
     3.7.   Summary of Test Result....................................................................................................8




Shenzhen Toby Technology Co.,Ltd.                                   FCC ID : YHXMPRFB-R                                                Page 2 of 10


                                                                                   Report No.: TB-F107144




                                    TEST REPORT DECLARATION


                      Applicant         : Masterbuilt Manufacturing, Inc.

                      Manufacturer      : San Yan Electronic Co., Ltd

                      EUT Description   : Digital Meat Probe with RF monitor

                      Model No.         : 23100111, 20100111, 20100311




        The device described above is tested by Bontek Compliance Testing Laboratory Ltd. to
        determine
        the maximum emission levels emanating from the device. The maximum emission levels are
        compared to the FCC Part 15 Subpart B limits for both radiation and conduction emissions.

        The measurement results are contained in this test report and Shenzhen Toby Technology Co.,
        Ltd. is assumed full responsibility for the accuracy and completeness of these measurements.
        Also, this report shows that the EUT to be technically compliant with the FCC official limits.

        This report applies to above tested sample only. This report shall not be reproduced in part
        without written approval of Shenzhen Toby Technology Co., Ltd.




                      Reported by:                               Date:          June 03, 2010
                                              (Erin)



                      Reviewer:                                  Date:          June 03, 2010
                                          (Jacky Wang)



                      Approved by:                               Date:          June 03, 2010
                                        (Justin Zhang)




Shenzhen Toby Technology Co.,Ltd.                  FCC ID : YHXMPRFB-R                             Page 3 of 10


                                                                                       Report No.: TB-F107144




 1. GENERAL INFORMATION

        1.1. Product Description for Equipment Under Test (EUT)
               Client Information

                Applicant            :   Masterbuilt Manufacturing, Inc.
                Address              :   1 Masterbuilt Court • Columbus, Georgia 31907, USA
                Manufacturer         :   San Yan Electronic Co., Ltd
                Address              :   No.2, 7th South of Street, Qinggong Road 3, Foshan City,
                                         Guangdong, P.R.China.


               General Description of E.U.T

                    Items                         Description
                    EUT Description:              Digital Meat Probe with RF monitor
                                                  23100111, 20100111, 20100311
                    Model No.:                    (Note: The samples are the same except only
                                                  color is different. We take 23100111 for test.)
                    Rated Voltage:                DC 3V Batteries

                    Frequency Range:              433.92MHz

                    Tape of Antenna:              Internal Antenna
                    For more information refer to the circuit diagram form and the user’s manual.

                    The test data is gathered from a production sample, provided by the manufacturer.
        1.2. Test Standards
               The following report is prepared on behalf of the Masterbuilt Manufacturing, Inc. in
               accordance with Part 2, Subpart J, and Part 15, Subparts A and B of the Federal
               Communication Commissions rules.
               The objective is to determine compliance with FCC Part 15, Subpart B, and section
               15.205, 15.107, and 15.109 rules.
               Maintenance of compliance is the responsibility of the manufacturer. Any modification of
               the product, which result in lowering the emission/immunity, should be checked to ensure
               compliance has been maintained.
        1.3. Related Submittal(s)/Grant(s)

               No Related Submittal(s).


Shenzhen Toby Technology Co.,Ltd.                     FCC ID : YHXMPRFB-R                               Page 4 of 10


                                                                                     Report No.: TB-F107144
        1.4. Test Methodology

               All measurements contained in this report were conducted with ANSI C63.4-2009,
               American National Standard for Methods of Measurement of Radio-Noise Emissions
               from Low-Voltage Electrical and Electronic Equipment in the range of 9 kHz to 40 GHz.


               The equipment under test (EUT) was configured to measure its highest possible emission
               level. The test modes were adapted accordingly in reference to the Operating Instructions.
               The EUT was set to keep Receiving during the test.
        1.5. Accessories Equipment List and Details

                       Manufacturer          Description                Model       Serial Number
                           /                     /                        /                /
        1.6. EUT Cable List and Details
                                                                      Shielded/      With Core/
                    Cable Description       Length (M)
                                                                     Unshielded     Without Core
                               /                  /                       /               /

        1.7. Test Location

                FCC – Registration No.: 338263
                Bontek Compliance Testing Laboratory Ltd. EMC Laboratory has been registered and
                fully described in a report filed with the (FCC) Federal Communications Commission.
                The acceptance letter from the FCC is maintained in our files and the Registration
                338263, March, 2008.

                Bontek Compliance Testing Laboratory Ltd
                Address: 1/F, Block East H-3, OCT Eastern Ind. ZoneQiaocheng East Road, Nanshan,
                         Shenzhen, 518055 China




Shenzhen Toby Technology Co.,Ltd.                     FCC ID : YHXMPRFB-R                            Page 5 of 10


                                                                                  Report No.: TB-F107144




 2. SUMMARY OF TEST RESULTS

                               DESCRIPTION OF TEST                          RESULT
                           §15.109(a) Radiated Emission                     Compliant




Shenzhen Toby Technology Co.,Ltd.                     FCC ID : YHXMPRFB-R                         Page 6 of 10


                                                                                         Report No.: TB-F107144




 3. §15.109(A) - RADIATED EMISSION

        3.1. Measurement Uncertainty

              Base on NIS 81, The Treatment of Uncertainty in EMC Measurements, the best estimate of
              the uncertainty of any radiation emissions measurement is ±3.0 dB.
        3.2. Standard Applicable

                According to §15.109(a), the field strength of emissions from intentional radiators
                operated under this section shall not exceed the following:
                              Frequency of Emission                           Field Strength
                                       (MHz)                                (microvolts/meter)
                                        30-88                                      100
                                       88-216                                      150
                                       216-960                                     200
                                      Above 960                                    500
                  Note: a distance of 3 meters
        3.3. Test Equipment List and Details

           Description          Manufacturer      Model No.      Serial No.       Cal. Date      Cal. Date
          Spectrum              ROHDE&
                                                  FSEA20         DE25181          2009-08-12     2010-08-11
           Analyzer             SCHWARZ
         Positioning
                                C&C               CC-C-1F        N/A              2009-08-12     2010-08-11
          Controller
            Trilog
          Broadband             SCHWARZBECK       VULB9163       9163-333         2009-07-21     2010-07-20
           Antenna
         Horn Antenna          SCHWARZBECK        BBHX 9120 9120-426              2009-07-21     2010-07-20
          RF Switch            EM                 EMSW18    SW060023              2009-08-12     2010-08-11
          Amplifier            Agilent            8447F     3113A06717            2009-08-12     2010-08-11
         Coaxial Cable         SCHWARZBECK        AK9513    9513-10               2009-08-12     2010-08-11
          EMI Test             ROHDE&
                                                  ESPI           25498514         2009-08-12     2010-08-11
           Receiver            SCHWARZ
          EMI Test             ROHDE&
                                                  ESI26          838786/103       2009-08-12     2010-08-11
           Receiver            SCHWARZ
           Receiver
                                ROHDE&
            Horn                                  HF906          100013           2009-08-12     2010-08-11
                                SCHWARZ
           Antenna
          Statement of Traceability:All calibrations have been performed per the NVLAP requirements
                                    traceable to the NIST.

Shenzhen Toby Technology Co.,Ltd.                     FCC ID : YHXMPRFB-R                                Page 7 of 10


                                                                                        Report No.: TB-F107144
        3.4. Test Procedure

               The setup of EUT is according with per ANSI C63.4-2009 measurement procedure.
               The specification used was with the FCC Part 15.109 Limit.
               The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm
               long in the middle. The spacing between the peripherals was 10 cm.




        3.5. Corrected Amplitude & Margin Calculation

             The Corrected Amplitude is calculated by adding the Antenna Factor and the Cable Factor,
             and subtracting the Amplifier Gain from the Amplitude reading. The basic equation is as
             follows:
                                    Corr. Ampl. = Indicated Reading – Corr. Factor
             The “Margin” column of the following data tables indicates the degree of compliance with
             the applicable limit.         For example, a margin of -6dBμV means the emission is 6dBμV
             below the maximum limit for Class B. The equation for margin calculation is as follows:

                                    Margin = Corr. Ampl. – FCC Part 15B Limit
        3.6. Environmental Conditions
                Temperature:                                                21° C
                Relative Humidity:                                          53 %
                ATM Pressure:                                             1012 mbar
        3.7. Summary of Test Result

             According to the data in section 3.7, the EUT complied with the the FCC Part15 Paragraph
             15.109(a) standards.


Shenzhen Toby Technology Co.,Ltd.                          FCC ID : YHXMPRFB-R                           Page 8 of 10


                                                                        Report No.: TB-F107144


      Plot of Radiation Emissions Test Data
      Radiated Disturbance
      EUT: Digital Meat Probe with RF monitor
      M/N: 23100111
      Operating Condition: RX
      Test Specification: Horizontal & Vertical
      Comment: DC 3V


      Horizontal




Shenzhen Toby Technology Co.,Ltd.                 FCC ID : YHXMPRFB-R                   Page 9 of 10


                                                          Report No.: TB-F107144
             Vertical




Shenzhen Toby Technology Co.,Ltd.   FCC ID : YHXMPRFB-R                   Page 10 of 10



Document Created: 2010-06-18 13:47:47
Document Modified: 2010-06-18 13:47:47

© 2025 FCC.report