190510013RFC-2_FCC_Part_15.247EDR_Report_Part_2

FCC ID: YHLBOLDN1

Test Report

Download: PDF
FCCID_4357804

                                                               Page 31 of 50                          Report No.: 190510013RFC-2

                                   Pulse Width                                  Number of Pulses in 31.6 Seconds
                                                                  π/4DQPSK_2-DH1




                                                                  π/4DQPSK_2-DH3




                                                                  π/4DQPSK_2-DH5




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 32 of 50                          Report No.: 190510013RFC-2

                                   Pulse Width                                             Number of Pulses in 31.6 Seconds
                                                                     8DPSK_3-DH1




                                                                     8DPSK_3-DH3




                                                                     8DPSK_3-DH5




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 33 of 50                          Report No.: 190510013RFC-2

      5.8 CONDUCTED OUT OF BAND EMISSION
         Test Requirement:            FCC 47 CFR Part 15 Subpart C Section 15.247(d)
         Test Method:                 ANSI C63.10-2013 Section 6.10.4 & Section 7.8.8
         Limit:                       In any 100kHz bandwidth outside the frequency bands in which the spread spectrum
                                      intentional radiator in operating, the radio frequency power that is produced by the
                                      intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the
                                      band that contains the highest level of the desired power.
         Test Procedure:              Remove the antenna from the EUT and then connect a low loss RF cable from the
                                      antenna port to the spectrum analyzer.
                                      Use the following spectrum analyzer settings:

                                      Step 1:Measurement Procedure REF
                                      a) Set instrument center frequency to 2400 MHz or 2483.5 MHz.
                                      b) Wide enough to capture the peak level of the emission operating on the channel
                                          closest to the band edge, as well as any modulation products that fall outside of the
                                          authorized band of operation.
                                      c) Set the RBW = 100 kHz.
                                      d) Set the VBW ≥ 3 x RBW.
                                      e) Detector = peak.
                                      f) Sweep time = auto couple.
                                      g) Sweep points ≥ 2 x Span/RBW
                                      h) Trace mode = max hold.
                                      i)  Allow the trace to stabilize.
                                      j)  Set the marker on the emission at the band edge, or on the highest modulation
                                          product outside of the band, if this level is greater than that at the band edge.
                                          Enable the marker-delta function, and then use the marker-to-peak function to
                                          move the marker to the peak of the in-band emission.

                                      Step 2:Measurement Procedure OOBE
                                      a) Set RBW = 100 kHz.
                                      b) Set VBW ≥ 300 kHz.
                                      c) Detector = peak.
                                      d) Sweep = auto couple.
                                      e) Trace Mode = max hold.
                                      f) Allow trace to fully stabilize.
                                      g) Use the peak marker function to determine the maximum amplitude level.

                                      Note: The cable loss and attenuator loss were offset into measure device as an
                                      amplitude offset.
         Test Setup:                  Refer to section 4.5.3 for details.
         Instruments Used:            Refer to section 3 for details
         Test Mode:                   Hopping Frequencies Transmitter mode
         Test Results:                Pass




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 34 of 50                          Report No.: 190510013RFC-2

       The test plots as follows:
                                                                           GFSK
                           In-Band Reference Level                                                 Out of Band Emission
                                                                    Lowest Channel




                                                                    Middle Channel




                                                                   Highest Channel




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 35 of 50                          Report No.: 190510013RFC-2


                                                                       π/4DQPSK
                           In-Band Reference Level                                                 Out of Band Emission
                                                                    Lowest Channel




                                                                    Middle Channel




                                                                   Highest Channel




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 36 of 50                          Report No.: 190510013RFC-2


                                                                          8DPSK
                           In-Band Reference Level                                                 Out of Band Emission
                                                                    Lowest Channel




                                                                    Middle Channel




                                                                   Highest Channel




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 37 of 50                          Report No.: 190510013RFC-2


                          Hopping Lowest Channel                                                Hopping Highest Channel
                                                                           GFSK




                                                                       π/4DQPSK




                                                                          8DPSK




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 38 of 50                          Report No.: 190510013RFC-2

      5.9 RADIATED SPURIOUS EMISSIONS
         Test Requirement:            FCC 47 CFR Part 15 Subpart C Section 15.205/15.209
         Test Method:                 ANSI C63.10-2013 Section 6.3 & 6.5 & 6.6
         Receiver Setup:
                                   Frequency                                                                RBW
                             0.009 MHz-0.150 MHz                                                         200/300 kHz
                              0.150 MHz -30 MHz                                                           9/10 kHz
                                 30 MHz-1 GHz                                                            100/120 kHz
                                  Above 1 GHz                                                              1 MHz
         Limits:
         Spurious Emissions
                                             Field strength                                                                  Measurement
                   Frequency                                           Limit (dBµV/m )                 Remark
                                            (microvolt/meter)                                                                distance (m)
            0.009 MHz-0.490 MHz               2400/F(kHz)                       --                       --                       300
            0.490 MHz-1.705 MHz               24000/F(kHz)                      --                       --                        30
             1.705 MHz-30 MHz                      30                           --                       --                        30
               30 MHz-88 MHz                      100                          40.0                  Quasi-peak                    3
              88 MHz-216 MHz                      150                          43.5                  Quasi-peak                    3
              216 MHz-960 MHz                     200                          46.0                  Quasi-peak                    3
                960MHz-1GHz                       500                          54.0                  Quasi-peak                    3
                 Above 1 GHz                      500                          54.0                   Average                      3

         Remark:
         1. The lower limit shall apply at the transition frequencies.
         2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
         3. For frequencies above 1000 MHz, the field strength limits are based on average detector, however, the
             peak field strength of any emission shall not exceed the maximum permitted average limits, specified
             above by more than 20 dB under any condition of modulation.
         Test Setup:            Refer to section 4.5.1 for details.
         Test Procedures:
         1. From 30 MHz to 1GHz test procedure as below:
         1) The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter semi-anechoic
             camber. The table was rotated 360 degrees to determine the position of the highest radiation.
         2) The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
             of a variable-height antenna tower.
         3) The antenna height is varied from one meter to four meters above the ground to determine the maximum
             value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the
             measurement.
         4) For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned
             to heights from 1 meter to 4 meters (for the test frequency of below 30MHz, the antenna was tuned to
             heights 1 meter) and the rota table table was turned from 0 degrees to 360 degrees to find the maximum
             reading.
         5) The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold
             Mode.
         6) If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing could
             be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have
             10dB margin would be re-tested one by one using peak, quasi-peak or average method as specified and
             then reported in a data sheet.
         2. Above 1GHz test procedure as below:
         1) Different between above is the test site, change from Semi- Anechoic Chamber to fully Anechoic Chamber
             and change form table 0.8 meter to 1.5 meter( Above 18GHz the distance is 1 meter and table is 1.5
             meter).
         2) Test the EUT in the lowest channel ,middle channel, the Highest channel
         3) The radiation measurements are performed in X, Y, Z axis positioning for Transmitting mode, and found

Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 39 of 50                          Report No.: 190510013RFC-2

             the Y axis positioning which it is worse case.
         4) Repeat above procedures until all frequencies measured was complete.
         Equipment Used:        Refer to section 3 for details.
         Test Result:           Pass
         The measurement data as follows:

         Radiated Emission Test Data (9 KHz ~ 30 MHz):
         The amplitude of spurious emissions attenuated more than 20 dB below the permissible value is not required
         to be report.

         Radiated Emission Test Data (30 MHz ~ 1 GHz):
         Worst-Case Configuration
         Horizontal




                                                               Correction
                           Frequency           Reading                             Result            Limit            Margin
              No.                                                factor                                                                Detector
                             (MHz)            (dBuV/m)                           (dBuV/m)          (dBuV/m)            (dB)
                                                                  (dB)
                1            51.900              34.17           -13.33             20.84             40.00            -19.16               Peak
                2            68.264              32.21           -13.82             18.39             40.00            -21.61               Peak
                3            145.811             26.90           -11.09             15.81             43.50            -27.69               Peak
                4            282.270             25.81            -7.31             18.50             46.00             -27.5               Peak
                5            430.305             26.07            -4.44             21.63             46.00            -24.37               Peak
                6            945.334             25.52             4.05             29.57             46.00            -16.43               Peak




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 40 of 50                          Report No.: 190510013RFC-2


         Vertical




                                                               Correction
                           Frequency           Reading                             Result            Limit            Margin
              No.                                                factor                                                                Detector
                             (MHz)            (dBuV/m)                           (dBuV/m)          (dBuV/m)            (dB)
                                                                  (dB)
            1         32.184        28.32                         -5.54
                                                                22.78          40.00       -17.22         Peak
            2         97.002        29.50                        -11.85
                                                                17.65          43.50       -25.85         Peak
            3         280.294       26.01                         -7.32
                                                                18.69          46.00       -27.31         Peak
            4         433.340       27.11                         -4.42
                                                                22.69          46.00       -23.31         Peak
            5         693.910       27.41                          0.11
                                                                27.52          46.00       -18.48         Peak
            6         925.613       25.27                          3.92
                                                                29.19          46.00       -16.81         Peak
       Remark:
       1. Correct Factor = Antenna Factor + Cable Loss - Amplifier Gain, the value was added to Original Receiver
          Reading by the software automatically.
       2. Result = Reading + Correct Factor.
       3. Margin = Result – Limit




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 41 of 50                          Report No.: 190510013RFC-2

         Radiated Emission Test Data (Above 1GHz):
         Lowest Channel:
                                                                      Correction
                    Frequency           Reading   Result                           Limit  Margin                                      Antenna
           No.                                                          Factor                   Detector
                      (MHz)            (dBuV/m) (dBuV/m)                         (dBuV/m)  (dB)                                       Polaxis
                                                                         (dB)
            1         4804.00             43.14           47.07          3.93      74.00  -26.93  Peak                                Horizontal
            2         4804.00             29.78           33.71          3.93      54.00  -20.29 Average                              Horizontal
            3         7206.00             41.30           48.06          6.76      74.00  -25.94  Peak                                Horizontal
            4         7206.00             29.88           36.64          6.76      54.00  -17.36 Average                              Horizontal
            5         4804.00             42.50           47.43          4.93      74.00  -26.57  Peak                                 Vertical
            6         4804.00             30.01           34.94          4.93      54.00  -19.06 Average                               Vertical
            7         7206.00             40.83           47.17          6.34      74.00  -26.83  Peak                                 Vertical
            8         7206.00             29.05           35.39          6.34      54.00  -18.61 Average                               Vertical

         Middle Channel:
                                                                      Correction
                    Frequency           Reading   Result                           Limit  Margin                                      Antenna
           No.                                                          Factor                   Detector
                      (MHz)            (dBuV/m) (dBuV/m)                         (dBuV/m)  (dB)                                       Polaxis
                                                                         (dB)
            1         4880.00             41.04           45.03          3.99      74.00  -28.97  Peak                                Horizontal
            2         4880.00             29.70           33.69          3.99      54.00  -20.31 Average                              Horizontal
            3         7320.00             41.05           48.03          6.98      74.00  -25.97  Peak                                Horizontal
            4         7320.00             29.46           36.44          6.98      54.00  -17.56 Average                              Horizontal
            5         4880.00             41.37           46.36          4.99      74.00  -27.64  Peak                                 Vertical
            6         4880.00             29.93           34.92          4.99      54.00  -19.08 Average                               Vertical
            7         7320.00             42.36           48.84          6.48      74.00  -25.16  Peak                                 Vertical
            8         7320.00             28.86           35.34          6.48      54.00  -18.66 Average                               Vertical

         Highest Channel:
                                                                      Correction
                    Frequency           Reading   Result                           Limit  Margin                                      Antenna
           No.                                                          Factor                   Detector
                      (MHz)            (dBuV/m) (dBuV/m)                         (dBuV/m)  (dB)                                       Polaxis
                                                                         (dB)
            1         4960.00             41.63           45.69          4.06      74.00  -28.31  Peak                                Horizontal
            2         4960.00             29.18           33.24          4.06      54.00  -20.76 Average                              Horizontal
            3         7440.00             41.44           48.63          7.19      74.00  -25.37  Peak                                Horizontal
            4         7440.00             29.75           36.94          7.19      54.00  -17.06 Average                              Horizontal
            5         4960.00             41.48           46.54          5.06      74.00  -27.46  Peak                                 Vertical
            6         4960.00             29.53           34.59          5.06      54.00  -19.41 Average                               Vertical
            7         7440.00             40.58           47.21          6.63      74.00  -26.79  Peak                                 Vertical
            8         7440.00             29.08           35.71          6.63      54.00  -18.29 Average                               Vertical
       Remark:
       1. All possible modes of operation were investigated. Only the worst case emissions reported.
       2. Correct Factor = Antenna Factor + Cable Loss + Amplifier, the value was added to Original Receiver Reading
       by the software automatically.
       3. Result = Reading + Correct Factor.
       4. Margin = Result – Limit


Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 42 of 50                          Report No.: 190510013RFC-2

      5.10        BAND EDGE MEASUREMENTS (RADIATED)
         Test Requirement: FCC 47 CFR Part 15 Subpart C Section 15.205/15.209
         Test Method:           ANSI C63.10-2013 Section 6.10.5
         Limits:
         Radiated emissions which fall in the restricted bands, as defined in section 15.205(a), must also comply with
         the radiated emission limits specified in section 15.209(a).
                         Frequency                         Limit (dBµV/m @3m)                     Remark
                       30 MHz-88 MHz                               40.0                      Quasi-peak Value
                      88 MHz-216 MHz                               43.5                      Quasi-peak Value
                     216 MHz-960 MHz                               46.0                      Quasi-peak Value
                       960 MHz-1 GHz                               54.0                      Quasi-peak Value
                                                                   54.0                       Average Value
                        Above 1 GHz
                                                                   74.0                          Peak Value
         Test Setup:           Refer to section 4.5.1 for details.
         Test Procedures:
         Radiated band edge measurements at 2390 MHz and 2483.5 MHz were made with the unit transmitting in the
         low end of the channel range and the high end closest to the restricted bands respectively. The emissions
         were made on the 966 Semi-Chamber. Use (resolution bandwidth (RBW) = 1 MHz, video bandwidth (VBW) =
         3 MHz for peak levels and RBW = 1 MHz and VBW = 10 Hz or 1/T for average levels).

         1. Use radiated spurious emission test procedure described in clause 5.10. The transmitter output (antenna
         port) was connected to the test receiver.
         2. Set the PK and AV limit line.
         3. Record the fundamental emission and emissions out of the band-edge.
         4. Determine band-edge compliance as required.
         Equipment Used:        Refer to section 3 for details.
         Test Result:           Pass
         The measurement data as follows:




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 43 of 50                          Report No.: 190510013RFC-2


                Test Channel:                     Lowest Channel                        Ant. Polar. :                       Horizontal




                                                                Correction
         Frequency             Reading   Result                              Limit  Margin
                                                                  Factor                                           Detector Conclusion
           (MHz)              (dBuV/m) (dBuV/m)                            (dBuV/m)  (dB)
                                                                    (dB)
            2390.00              47.96            45.18            -2.78     74.00  -28.82                           Peak               Pass
            2390.00              34.85            32.07            -2.78     54.00  -21.93                          Average             Pass




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 44 of 50                          Report No.: 190510013RFC-2

                Test Channel:                     Lowest Channel                        Ant. Polar. :                         Vertical




                                                                Correction
         Frequency             Reading   Result                              Limit  Margin
                                                                  Factor                                           Detector Conclusion
           (MHz)              (dBuV/m) (dBuV/m)                            (dBuV/m)  (dB)
                                                                    (dB)
            2390.00              48.04            47.69            -0.35     74.00  -26.31                           Peak               Pass
            2390.00              34.69            34.34            -0.35     54.00  -19.66                          Average             Pass




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 45 of 50                          Report No.: 190510013RFC-2

                Test Channel:                    Highest Channel                        Ant. Polar. :                       Horizontal




                                                                Correction
         Frequency             Reading   Result                              Limit  Margin
                                                                  Factor                                           Detector Conclusion
           (MHz)              (dBuV/m) (dBuV/m)                            (dBuV/m)  (dB)
                                                                    (dB)
            2483.50              51.60            48.99            -2.61     74.00  -25.01                           Peak               Pass
            2483.50              42.39            39.78            -2.61     54.00  -14.22                          Average             Pass




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 46 of 50                          Report No.: 190510013RFC-2

                Test Channel:                    Highest Channel                        Ant. Polar. :                         Vertical




                                                                Correction
         Frequency             Reading   Result                              Limit  Margin
                                                                  Factor                                           Detector Conclusion
           (MHz)              (dBuV/m) (dBuV/m)                            (dBuV/m)  (dB)
                                                                    (dB)
            2483.50              54.44            54.15            -0.29     74.00  -19.85                           Peak               Pass
            2483.50              45.12            44.83            -0.29     54.00   -9.17                          Average             Pass
       Remark:
       1. Correct Factor = Antenna Factor + Cable Loss + Amplifier, the value was added to Original Receiver Reading
       by the software automatically.
       2. Result = Reading + Correct Factor.
       3. Margin = Result - Limit




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 47 of 50                          Report No.: 190510013RFC-2

      5.11        CONDUCTED EMISSION
         Test Requirement:            47 CFR Part 15C Section 15.207
         Test Method:                 ANSI C63.10-2013 Section 6.2
         Limits:
                     Frequency range                                                       Limits (dB(μV)
                          (MHz)                                        Quasi-peak                                      Average
                         0,15 to 0,50                                   66 to 56                                       56 to 46
                          0,50 to 5                                        56                                             46
                           5 to 30                                         60                                             50
         Remark:
         1. The lower limit shall apply at the transition frequencies.
         2. The limit decreases linearly with the logarithm of the frequency in the range 0.15 to 0.50 MHz.
         Test Setup:             Refer to section 4.5.2 for details.
         Test Procedures:
         Test frequency range :150KHz-30MHz
         1) The mains terminal disturbance voltage test was conducted in a shielded room.
         2) The EUT was connected to AC power source through a LISN 1 (Line Impedance Stabilization Network)
              which provides a 50Ω/50µH + 5Ω linear impedance. The power cables of all other units of the EUT were
              connected to a second LISN 2, which was bonded to the ground reference plane in the same way as the
              LISN 1 for the unit being measured. A multiple socket outlet strip was used to connect multiple power
              cables to a single LISN provided the rating of the LISN was not exceeded.
         3) The tabletop EUT was placed upon a non-metallic table 0.8m above the ground reference plane. And for
              floor-standing arrangement, the EUT was placed on the horizontal ground reference plane,
         4) The test was performed with a vertical ground reference plane. The rear of the EUT shall be 0.4 m from
              the vertical ground reference plane. The vertical ground reference plane was bonded to the horizontal
              ground reference plane. The LISN 1 was placed 0.8 m from the boundary of the unit under test and bonded
              to a ground reference plane for LISNs mounted on top of the ground reference plane. This distance was
              between the closest points of the LISN 1 and the EUT. All other units of the EUT and associated equipment
              was at least 0.8 m from the LISN 2.
         5) In order to find the maximum emission, the relative positions of equipment and all of the interface cables
              must be changed according to ANSI C63.10 on conducted measurement.
         Equipment Used:         Refer to section 3 for details.
         Test Result:            Pass




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 48 of 50                          Report No.: 190510013RFC-2

         The measurement data as follows:
         Quasi Peak and Average:
         Mode: BT Link
         Live Line




                                                          Correction
                     Frequency           Reading                               Result              Limit             Margin
           No.                                              factor                                                                    Detector
                       (MHz)             (dBuV)                                (dBuV)             (dBuV)              (dB)
                                                             (dB)
            1           0.162              20.10            10.02               30.12              55.36             -25.24           Average
            2           0.162              43.60            10.02               53.62              65.36             -11.74             QP
            3           0.198              16.70            10.01               26.71              53.69             -26.98           Average
            4           0.198              40.10            10.01               50.11              63.69             -13.58             QP
            5           0.246              12.50            10.00               22.50              51.89             -29.39           Average
            6           0.246              36.70            10.00               46.70              61.89             -15.19             QP




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 49 of 50                          Report No.: 190510013RFC-2

         Neutral Line




                                                          Correction
                     Frequency           Reading                               Result              Limit             Margin
           No.                                              factor                                                                    Detector
                       (MHz)             (dBuV)                                (dBuV)             (dBuV)              (dB)
                                                             (dB)
            1           0.162              20.40            10.00               30.40              55.36             -24.96           Average
            2           0.162              43.90            10.00               53.90              65.36             -11.46             QP
            3           0.186              14.30             9.99               24.29              54.21             -29.92           Average
            4           0.186              41.70             9.99               51.69              64.21             -12.52             QP
            5           0.234              13.40             9.98               23.38              52.31             -28.93           Average
            6           0.234              37.80             9.98               47.78              62.31             -14.53             QP

       Remark:
       1. Correct Factor = LISN Factor + Cable Loss + Pulse Limiter Factor, the value was added to Original
          Receiver Reading by the software automatically.
       2. Result = Reading + Correct Factor.
       3. Margin = Result - Limit
       4. An initial pre-scan was performed on the Phase and neutral lines with peak detector. Quasi-Peak and
          Average measurement were performed at the frequencies with maximized peak emission were detected.
       5. All possible modes of operation were investigated, and testing at two nominal voltages of 240V/50Hz and
          120V/60Hz, only the worst case emissions reported.




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 50 of 50                          Report No.: 190510013RFC-2


APPENDIX 1 PHOTOS OF TEST SETUP
          See test photos attached in Appendix 1 for the actual connections between Product and support equipment.



APPENDIX 2 PHOTOS OF EUT CONSTRUCTIONAL DETAILS

                                          Refer to Appendix 2 for EUT external and internal photos.




                                                                 *** End of Report ***




       The test report is effective only with both signature and specialized stamp. The result(s) shown in this report refer
       only to the sample(s) tested. Without written approval of UnionTrust, this report can’t be reproduced except in full.




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com



Document Created: 2019-07-16 11:30:03
Document Modified: 2019-07-16 11:30:03

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC