FCC_SAR_Appendix_B

FCC ID: YHLBLUZOEYSMART

RF Exposure Info

Download: PDF
FCCID_4355989

Test Laboratory : UnionTrust                                                  Date: 2019/6/1


PO1_GSM850_GSM_Right Check_128

DUT: EUT

Communication System: GSM850; Frequency: 824.2 MHz;Duty Cycle: 1:8.3
Medium: H835 Medium parameters used (interpolated): {= 824.2 MHz; 0 =0.876 mho/m; 8. = 42.2;
p = 1000 kg/m®

DASY4 Configuration:
— Probe: ES3DV3 — SN3090; ConvF(6.12, 6.12, 6.12); Calibrated: 2019/4/12
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 $n662; Calibrated: 2019/4/11
— Phantom: SAM 1; Type: QD 000 P40 CB; Serial: TP/1378
— ; Postprocessing SW: SEMCAD, V1.8 Build 186


Test/Area Scan (61x71x1): Mcasurement grid: dx=1 Smm, dy=1 5mm
Maximum value of SAR (interpolated) = 0.289 mW/g

Test/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, daz=5mm
Reference Value =6.49 V/m; Power Drift=—0.07 dB
Peak SAR (extrapolated) = 0.333 W/kg
SAR(1 g) = 0.255 mW/g; SAR(10 g) = 0.182 mW/g
Maximum value of SAR (measured) = 0.286 mW/g

    dB
    0.000


    —2.04


    —4.08


    —6.12


    —8.16


    10.2
                0 dB =0.286mW/g


Test Laboratory: UnionTrust                                                   Date: 2019/931


PO2_GSM1900_GSM_Left Cheek_512
DUT: EUT

Communication System: GSM1900; Frequency: 1850.2 MHz;Duty Cycle: 1:8.3
Medium: H1900 Medium parameters used (interpolated): {= 1850.2 MHz; 0 = 1.35 mho/m; 8. <4114;
p = 1000 kg/m}

DASY4 Configuration:
— Probe: ES3DV3 — SN3090; ConvF(5.06, 5.06, 5.06); Calibrated: 2019/4/12
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 $n662; Calibrated: 2019/4/11
— Phantom: SAM 1; Type: QD 000 P40 CB; Serial: TP/1378
— ; Postprocessing SW: SEMCAD, V1.8 Build 186


Test/Area Scan (61x71x1): Measurement grid: dx=1 5mm, dy=1 5mm
Maximum value of SAR (interpolated)= 0.302 mW/g

Test/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=3.07 V/m; Power Drift=—0.13dB
Peak SAR (extrapolated) = 0.375 W/kg
SAR(1 g) = 0.257 mW/g; SAR(10 g) = 0.164 mW/g
Maximum value of SAR (measured) = 0.298 mW/g

   mWig
    0.298

    0.240

    0.182

    0.124

    0.066

    0.008


Test Laboratory: UnionTrust                                                  Date: 2019/5/31


PO3_WCDMA II_RMC12.2K_Left Cheek_9262

DUT: EUT

Communication System: WCDMA Band II; Frequency: 1852.4 MHz:Duty Cycle: 1:1
Medium: H1900 Medium parameters used (interpolated): £= 1852.4 MHz; 0 = 1.35 mho/m; 8. <4L1;
p = 1000 kg/m®

DASY4 Configuration:
— Probe: ES3DV3 — SN3090; ConvF(3.06, 5.06, 5.06); Calibrated: 2019/4/12
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAEA4 $n662; Calibrated: 2019/4/11
— Phantom: SAM 1; Type: QD 000 P40 CB; Serial: TP/1378
— ; Postprocessing SW: SEMCAD, V1.8 Build 186


Test/Area Scan (61x71x1): Measurement grid: dx=1 5mm, dy=1 Smm
Maximum value of SAR (interpolated) = 0.773 mW/g

Test/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value= 5.49 V/m; Power Drift=0.095 dB
Peak SAR (extrapolated) = 0.963 W/kg
SAR(1 g) = 0.661 mW/g; SAR(10 g) = 0.421 mW/g
Maximum value of SAR (measured) = 0.776 mW/g

   dB
    0.000

    —3.16

    —6.32

    —9.48

    "12.6

    15.8
               0 dB =0.776mW/g


Test Laboratory: UnionTrust                                                Date: 20196/1


PO4_WCDMA V_RMC12.2K._Right Cheek_4233
DUT: EUT

Communication System: WCDMA Band V; Frequency: 846.6 MHz;Duty Cycle: 1:1
Medium: H835 Medium parameters used: £=847 MHz; 0 = 0.897 mho/m; & = 41.9; p= 1000 kg/m>

DASY4 Configuration:
— Probe: ES3DV3 — SN3090; ConvF(6.12, 6.12, 6.12); Calibrated: 2019/4/12
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn662; Calibrated: 2019/4/11
— Phantom: SAM 1; Type: QD 000 P40 CB; Serial: TP/1378
— ; Postprocessing SW: SEMCAD, V1.8 Build 186


Test/Area Scan (61x71x1): Measurement grid: dx=1 5mm, dy=1 Smm
Maximum value of SAR (interpolated) = 0.368 mW/g

Test/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=6.37 V/m; Power Drift=—0.183 dB
Peak SAR (extrapolated)= 0.421 W/kg
SAR(1 g) = 0.323 mW/g; SAR(10 g) = 0.231 mW/g
Maximum value of SAR (measured) =0.361 mW/g

   dB
    0.000

    2.10

    ~4.20

    —6.30

    —8.40

    "10.5
               0 dB =0.361mW/g


Test Laboratory: UnionTrust                                                Date: 20196/14


PO5_802.11b_Right Cheek

DUT: EUT

Communication System: Wlan 802.11b; Frequency: 2412 MHz;Duty Cycle: 1:1
Medium: H2450 Medium parameters used: £=2412 MHz; 0 = 1.75 mho/m; 8.= 40.5; p= 1000
kg/m>

DASY4 Configuration:
— Probe: ES3DV3 — SN3090; ConvF(4.57, 4.57, 4.57); Calibrated: 2019/4/12
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn662; Calibrated: 2019/4/11
— Phantom: SAM 1; Type: QD 000 P40 CB; Serial: TP/1378
— ; Postprocessing SW: SEMCAD, V1.8 Build 186


Test/Area Scan (61x71x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (interpolated) = 0.241 mW/g

Test/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=8.68 V/m; Power Drift=0.006 dB
Peak SAR (extrapolated)= 0.371 W/kg
SAR(1 g) = 0.189 mW/g; SAR(10 g) = 0.099 mW/g
Maximum value of SAR (measured) =0.231 mW/g

   dB
    0.000

    —4.04

    —8.08

    "12.1

    "16.2

    —20.2
               0 dB =0.231mW/g


Test Laboratory: UnionTrust                                                  Date: 20196/1


PO6_GSM850_GSM_Rear Face_15mm_128

DUT: EUT

Communication System: GSM850; Frequency: 824.2 MHz;Duty Cycle: 1:8.3
Medium: B835 Medium parameters used (interpolated): {= 824.2 MHz; 0 = 0.984 mho/m; 8 <56.2;
p = 1000 kg/m®

DASY4 Configuration:
— Probe: ES3DV3 — SN3090; ConvF(6.18, 6.18, 6.18); Calibrated: 2019/4/12
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn662; Calibrated: 2019/4/11
— Phantom: Triple Flat Phantom 5.1C; Type: QD 000 P51 CA; Serial: 1125
— ; Postprocessing SW: SEMCAD, V1.8 Build 186


Test/Area Scan (71x61x1): Measurement grid: dx=1 5mm, dy=1 Smm
Maximum value of SAR (interpolated) = 0.445 mW/g

Test/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value= 19.9 V/m; Power Drift=—0.06 dB
Peak SAR (extrapolated)= 0.545 W/kg
SAR(1 g) = 0.391 mW/g; SAR(10 g) = 0.277 mW/g
Maximum value of SAR (measured) = 0.443 mW/g

   dB
    0.000

    —1.93

    —3.86

    —5.78

    —7.11

    —9.64
               0 dB =0.443mW/g


Test Laboratory: UnionTrust                                                  Date: 20196/1


PO7_GSM1900_GSM_Rear Face_15mm_512

DUT: EUT

Communication System: GSM1900; Frequency: 1850.2 MHz:Duty Cycle: 1:8.3
Medium: B1900 Medium parameters used (interpolated): {= 1850.2 MHz; 0 = 1.47 mho/m; 8 =53.9;
p = 1000 kg/m®

DASY4 Configuration:
— Probe: ES3DV3 — SN3090; ConvyF(4.79, 4.79, 4.79); Calibrated: 2019/4/12
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAEA4 $n662; Calibrated: 2019/4/11
— Phantom: Triple Flat Phantom 5.1C; Type: QD 000 P51 CA; Serial: 1125
— ; Postprocessing SW: SEMCAD, V1.8 Build 186


Test/Area Scan (71x61x1): Measurement grid: dx=1 5mm, dy=1 Smm
Maximum value of SAR (interpolated) = 0.321 mW/g

Test/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=11.8 V/m; Power Drift=—0.171 dB
Peak SAR (extrapolated) = 0.411 W/kg
SAR(1 g) = 0.261 mW/g; SAR(10 g) = 0.164 mW/g
Maximum value of SAR (measured) =0.311 mW/g

   dB
    0.000

    —2.90

    —5.40

    —8.10

    10.8

    "13.5
               0 dB =0.31 1mW/g


Test Laboratory: UnionTrust                                                   Date: 2019671


PO8_WCDMA II_RMC12.2K_Rear Face_15mm_9262
DUT: EUT

Communication System: WCDMA Band II; Frequency: 1852.4 MHz;Duty Cycle: 1:1
Medium: B1900 Medium parameters used (interpolated): £= 1852.4 MHz; 0 = 1.47 mho/m; 8. =53.9;
p = 1000 kg/m}

DASY4 Configuration:
— Probe: ES3DV3 — SN3090; ConvF(4.79, 4.79, 4.79); Calibrated: 2019/4/12
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 $n662; Calibrated: 2019/4/11
— Phantom: Triple Flat Phantom 5.1C; Type: QD 000 P51 CA; Serial: 1125
— ; Postprocessing SW: SEMCAD, V1.8 Build 186


Test/Area Scan (71x61x1): Measurement grid: dx=1 5mm, dy=1 5mm
Maximum value of SAR (interpolated)= 0.715 mW/g

Test/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, daz=5mm
Reference Value=14.7 V/m; Power Drift=—0.14 dB
Peak SAR (extrapolated) = 0.925 W/kg
SAR(1 g) = 0.586 mW/g; SAR(10 g) = 0.368 mW/g
Maximum value of SAR (measured) = 0.696 mW/g

   dB
    0.000

    —2.72

    ~5.44
                                                 n
    —8.16                                            s

    —10.9

    —13.6
               0 dB = 0.696mW/g


Test Laboratory: UnionTrust                                                Date: 20196/1


PO9_WCDMA V_RMC12.2K_Rear Face_15mm_4233
DUT: EUT

Communication System: WCDMA Band V; Frequency: 846.6 MHz:Duty Cycle: 1:1
Medium: B835 Medium parameters used: £= 847 MHz; 0 1.01 mho/m; e, = 55.9; p = 1000 kg/m*

DASY4 Configuration:
— Probe: ES3DV3 — SN3090; ConvF(6.18, 6.18, 6.18); Calibrated: 2019/4/12
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAEA4 $n662; Calibrated: 2019/4/11
— Phantom: Triple Flat Phantom 5.1C; Type: QD 000 P51 CA; Serial: 1125
— ; Postprocessing SW: SEMCAD, V1.8 Build 186


Test/Area Scan (71x61x1): Measurement grid: dx=1 5mm, dy=1 Smm
Maximum value of SAR (interpolated) = 0.629 mW/g

Test/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=23.6 V/m; Power Drift=—0.08 dB
Peak SAR (extrapolated) = 0.742 W/kg
SAR(1 g) = 0.559 mW/g; SAR(10 g) = 0.397 mW/g
Maximum value of SAR (measured) = 0.630 mW/g

   dB
    0.000

    —1.94

    —3.88

    —5.83

    147

    ~8.71
               0 dB =0.630mW/g


Test Laboratory : UnionTrust                                                Date: 2019/6/14


P10_802.11b_Rear Face_15mm

DUT: EUT

Communication System: Wian 802.11b; Frequency: 2412 MHz;Duty Cycle: 1:1
Medium: B2450 Medium parameters used: {= 2412 MHz; 0 = 1.97 mho/m; &.= 53.2; p = 1000

kg/m*

DASY4 Configuration:
— Probe: ES3DV3 — SN3090; ConvF(4.47, 4.47, 4.47); Calibrated: 2019/4/12
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE4 $n662; Calibrated: 2019/4/11
— Phantom: ‘I‘riple Flat Phantom 5.1C; Type: QD 000 P51 CA; Serial: 1125
— ; Postprocessing SW: SEMCAD, V1.8 Build 186


Test/Area Scan (71x61x1): Mcasurement grid: dx=1 2mm, dy=12mm
Maximum value of SAR (interpolated) = 0.053 mW/g

Test/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value =2.33 V/m; Power Drift= 0.186 dB
Peak SAR (extrapolated) =0.078 W/kg
SAR(1 g) = 0.044 mW/g; SAR(10 g) = 0.025 mW/g
Maximum value of SAR (measured) = 0.054 mW/g

    dB
    0.000

    —3.74

    —7.48

    11.2

    415.0



                0 dB =0.054mW/g