FCC Part 22H Report

FCC ID: YHLBLUJENNYSLD

Test Report

Download: PDF
FCCID_4079693

  Uni+#+nTrust                                                  Page 1 of 29                          Report No.: 181027005RFM—1




                                         FCC TEST REPORT


                                                 Product Name:               Feature Phone
                                                      Trade Mark:            BLU
                                                        Model No.:          JENNY SLIDE
                                               Report Number:               181027005RFM—1
                                               Test Standards:              FCC 47 CFR Part 22 Subpart H
                                                                            FCC 47 CFR Part 2
                                                             FGG ID:        YHLBLUJENNYSLD
                                                      Test Result:          PASS
                                                   Date of Issue:           November 19, 2018



                                                                  Prepared for:


                                              BLU Products, Inc.
                                     10814 NW 33rd St # 100 Doral, FL 33172



                                                                  Prepared by:

                  Shenzhen UnionTrust Quality and Technology Co., Ltd.
            16/F, Block A, Building 6, Baoneng Science and Technology Park,
              Qingxiang Road No.1, Longhua New District, Shenzhen, China
                                                    TEL: +86—755—2823 0888
                                                    FAX: +86—755—2823 0886




                    Tested by:                                                     Reviewed by:
                                                                                                                  Kevin Liang
                                                                                                              Assistant Manager



                Approved by:                                                                                 November 19, 2018




Shenzhen UnionTrust Quality and Technology Co:;
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86—755—28230888                  Fax: +86—755—28230886                  E—mail: info@uttlab.com                Hitp:/www.uttlab.com


                                                               Page 2 of 29                          Report No.: 181027005RFM-1

Version
       Version No.                         Date                                                   Description
            V1.0                  November 19, 2018                                                  Original




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                                          Page 3 of 29                                 Report No.: 181027005RFM-1



                                                                        CONTENTS
1.   GENERAL INFORMATION ....................................................................................................................................... 4
     1.1  CLIENT INFORMATION ........................................................................................................................................ 4
     1.2  EUT INFORMATION ............................................................................................................................................ 4
          1.2.1 GENERAL DESCRIPTION OF EUT ............................................................................................................ 4
          1.2.2 DESCRIPTION OF ACCESSORIES.............................................................................................................. 4
     1.3 PRODUCT SPECIFICATION SUBJECTIVE TO THIS STANDARD ................................................................................. 5
     1.4 DESCRIPTION OF SUPPORT UNITS ...................................................................................................................... 5
     1.5 TEST LOCATION ................................................................................................................................................. 5
     1.6 TEST FACILITY ................................................................................................................................................... 5
     1.7 DEVIATION FROM STANDARDS ............................................................................................................................ 6
     1.8 ABNORMALITIES FROM STANDARD CONDITIONS .................................................................................................. 6
     1.9 OTHER INFORMATION REQUESTED BY THE CUSTOMER ........................................................................................ 6
     1.10 MEASUREMENT UNCERTAINTY ........................................................................................................................... 6
2.   TEST SUMMARY ...................................................................................................................................................... 7
3.   EQUIPMENT LIST .................................................................................................................................................... 8
4.   TEST CONFIGURATION .......................................................................................................................................... 9
     4.1      ENVIRONMENTAL CONDITIONS FOR TESTING ........................................................................................................ 9
              4.1.1 NORMAL OR EXTREME TEST CONDITIONS ............................................................................................... 9
     4.2      TEST SETUP .................................................................................................................................................... 10
              4.2.1 FOR RADIATED EMISSIONS TEST SETUP ................................................................................................ 10
              4.2.2 FOR CONDUCTED RF TEST SETUP ........................................................................................................ 12
     4.3      TEST CHANNELS ............................................................................................................................................. 13
     4.4      SYSTEM TEST CONFIGURATION ........................................................................................................................ 13
     4.5      PRE-SCAN ....................................................................................................................................................... 13
5.   RADIO TECHNICAL REQUIREMENTS SPECIFICATION .................................................................................... 14
     5.1      REFERENCE DOCUMENTS FOR TESTING ............................................................................................................ 14
     5.2      EFFECTIVE RADIATED POWER (ERP) ............................................................................................................... 14
     5.3      CONDUCTED OUTPUT POWER .......................................................................................................................... 16
     5.4      PEAK-TO-AVERAGE RATIO ................................................................................................................................ 17
     5.5      99%&26DB BANDWIDTH ................................................................................................................................. 19
     5.6      BAND EDGE AT ANTENNA TERMINALS ............................................................................................................... 21
     5.7      SPURIOUS EMISSIONS AT ANTENNA TERMINALS ................................................................................................. 23
     5.8      FIELD STRENGTH OF SPURIOUS RADIATION ........................................................................................................ 25
     5.9      FREQUENCY STABILITY .................................................................................................................................... 28
APPENDIX 1 PHOTOS OF TEST SETUP ..................................................................................................................... 29
APPENDIX 2 PHOTOS OF EUT CONSTRUCTIONAL DETAILS ................................................................................. 29




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 4 of 29                          Report No.: 181027005RFM-1

1. GENERAL INFORMATION
   1.1 CLIENT INFORMATION
         Applicant:                             BLU Products, Inc.
         Address of Applicant:                  10814 NW 33rd St # 100 Doral, FL 33172
         Manufacturer:                          BLU Products, Inc.
         Address of Manufacturer:               10814 NW 33rd St # 100 Doral, FL 33172


      1.2 EUT INFORMATION
      1.2.1       General Description of EUT
         Product Name:                          Feature Phone
         Model No.:                             JENNY SLIDE
         Add. Model No.:                        N/A
         Trade Mark:                            BLU
         DUT Stage:                             Identical Prototype
                                                GSM Bands:             GSM850/1900
         EUT Supports Function:
                                                2.4 GHz ISM Band:      Bluetooth V2.1+EDR
         IMEI Code:                             869181029926126, 869181029926134
         Sample Received Date:                  October 26, 2018
         Sample Tested Date:                    October 26, 2018 to November 2, 2018


      1.2.2       Description of Accessories
                                                                         Adapter
         Trade Mark:                            BLU
         Model No.:                             US-NB-0550
         Input:                                 100-240 V~50/60 Hz 0.15 A
         Output:                                5.0 V    550 mA
         AC Cable:                              N/A
         DC Cable:                              1 Meter, Unshielded without ferrite

                                                                          Battery
         Trade Mark:                            BLU
         Model No.:                             N4C820T
         Battery Type:                          Lithium-ion Rechargeable Battery
         Rated Voltage:                         3.7 Vdc
         Rated Capacity:                        820 mAh




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 5 of 29                          Report No.: 181027005RFM-1

      1.3 PRODUCT SPECIFICATION SUBJECTIVE TO THIS STANDARD
         Support Networks:                      GSM
         Type of Modulation:                    GSM                                                          GMSK
         Frequency Range:                       GSM 850:                                                     824.2-848.8 MHz
         Max RF Output Power:                   GSM 850:                                                     32.70dBm
         Type of Emission:                      GSM 850:                                                     245KGXW
         Antenna Type:                          PIFA Antenna
         Antenna Gain:                          -0.4 dBi
         GPRS Class:                            Class 12
         Normal Test Voltage:                   3.7 Vdc
         Extreme Test Voltage:                  3.5 to 4.2Vdc
         Extreme Test
                                                -30 °C to +50 °C
         Temperature:


      1.4 DESCRIPTION OF SUPPORT UNITS
       The EUT has been tested with associated equipment below.
       1) Support Equipment
            Description        Manufacturer           Model No.                                  Serial Number                 Supplied by
                    N/A                         N/A                         N/A                         N/A                          N/A

       2) Support Cable
             Cable No.                    Description                  Connector                      Length                   Supplied by
                     1                   Antenna Cable                     SMA                      0.30 Meter                  UnionTrust


      1.5 TEST LOCATION


       Shenzhen UnionTrust Quality and Technology Co., Ltd.

       Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua
       New District, Shenzhen, China 518109
       Telephone: +86 (0) 755 2823 0888
       Fax: +86 (0) 755 2823 0886



      1.6 TEST FACILITY

       The test facility is recognized, certified, or accredited by the following organizations:

       CNAS-Lab Code: L9069
       The measuring equipment utilized to perform the tests documented in this report has been calibrated once a
       year or in accordance with the manufacturer's recommendations, and is traceable under the ISO/IEC/EN 17025
       to international or national standards. Equipment has been calibrated by accredited calibration laboratories.

       IC-Registration No.: 21600-1
       The 3m Semi-anechoic chamber of Shenzhen UnionTrust Quality and Technology Co., Ltd. has been registered
       by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.:
       21600-1.

       A2LA-Lab Certificate No.: 4312.01
Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 6 of 29                          Report No.: 181027005RFM-1

       Shenzhen UnionTrust Quality and Technology Co., Ltd. has been accredited by A2LA for technical competence
       in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025: 2005 General
       Requirements for the Competence of Testing and Calibration Laboratories and any additional program
       requirements in the identified field of testing.

       FCC Accredited Lab.
       Designation Number: CN1194
       Test Firm Registration Number: 259480




      1.7 DEVIATION FROM STANDARDS
       None.

      1.8 ABNORMALITIES FROM STANDARD CONDITIONS
       None.
      1.9 OTHER INFORMATION REQUESTED BY THE CUSTOMER
       None.

      1.10 MEASUREMENT UNCERTAINTY
       Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the
       Product as specified in CISPR 16-4-2. This uncertainty represents an expanded uncertainty expressed at
       approximately the 95% confidence level using a coverage factor of k=2.
         No.                          Item                                    Measurement Uncertainty
            1               Conducted emission 9KHz-150KHz                                                     ±3.8 dB
            2              Conducted emission 150KHz-30MHz                                                     ±3.4 dB
            3                Radiated emission 9KHz-30MHz                                                      ±4.9 dB
            4                Radiated emission 30MHz-1GHz                                                      ±4.7 dB
            5                Radiated emission 1GHz-18GHz                                                      ±5.1 dB
            6               Radiated emission 18GHz-26GHz                                                      ±5.2 dB
            7                Radiated emission 26GHz-40GHz                                                     ±5.2 dB




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 7 of 29                          Report No.: 181027005RFM-1

2. TEST SUMMARY
                                                 FCC 47 CFR Part 22 Subpart H Test Cases
                 Test Item                           Test Requirement                 Test Method                                       Result
            Effective Radiated                  FCC 47 CFR Part 2.1046(a) &      ANSI/TIA-603-E-2016 &
                                                                                                                                            PASS
               Power (ERP)                       FCC 47 CFR Part 22.913(a)       KDB 971168 D01v03r01
            Conducted Output                    FCC 47 CFR Part 2.1046(a) &      ANSI/TIA-603-E-2016 &
                                                                                                                                            PASS
                  Power                          FCC 47 CFR Part 22.913(a)       KDB 971168 D01v03r01
                                                                                 ANSI/TIA-603-E-2016 &
          Peak-to-average ratio                  FCC 47 CFR Part 22.913(a)                                                                  PASS
                                                                                 KDB 971168 D01v03r01
                                                                                 ANSI/TIA-603-E-2016 &
          99%&26dB Bandwidth                     FCC 47 CFR Part 2.1049(h)                                                                  PASS
                                                                                 KDB 971168 D01v03r01
          Band Edge at antenna                   FCC 47 CFR Part 2.1051 &        ANSI/TIA-603-E-2016 &
                                                                                                                                            PASS
                 terminals                       FCC 47 CFR Part 22.917(a)       KDB 971168 D01v03r01
          Spurious emissions at                  FCC 47 CFR Part 2.1051 &        ANSI/TIA-603-E-2016 &
                                                                                                                                            PASS
            antenna terminals                   FCC 47 CFR Part 22.917(a)(b)     KDB 971168 D01v03r01
             Field strength of                   FCC 47 CFR Part 2.1053 &        ANSI/TIA-603-E-2016 &
                                                                                                                                            PASS
           spurious radiation                   FCC 47 CFR Part 22.917(a)(b)     KDB 971168 D01v03r01
                                                 FCC 47 CFR Part 2.1055 &        ANSI/TIA-603-E-2016 &
            Frequency stability                                                                                                             PASS
                                                  FCC 47 CFR Part 22.355         KDB 971168 D01v03r01




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 8 of 29                          Report No.: 181027005RFM-1

3. EQUIPMENT LIST
                                                    Radiated Emission Test Equipment List
                                                                                Serial                        Cal. date            Cal. Due date
          Used           Equipment               Manufacturer   Model No.
                                                                               Number                       (mm dd, yyyy)         (mm dd, yyyy)
                       3M Chamber &
                                                ETS-LINDGREN               3M                N/A            Dec. 20, 2015         Dec. 19, 2018
                    Accessory Equipment
                         Receiver                      R&S              ESIB26             100114           Dec. 10, 2017         Dec. 10, 2018
                     Broadband Antenna          ETS-LINDGREN             3142E           00201566           Dec. 17, 2017         Dec. 17, 2018
                         Preamplifier                   HP               8447F          2805A02960          Dec. 10, 2017         Dec. 10, 2018
                     Broadband Antenna
                                                ETS-LINDGREN           3142E-PA          00201891            May 19, 2018          May 19, 2019
                       (Pre-amplifier)
                        Horn Antenna            ETS-LINDGREN              3117           00164202           Dec. 17, 2017         Dec. 17, 2018
                        Horn Antenna
                                                ETS-LINDGREN            3117-PA          00201874            May 22, 2018          May 22, 2019
                       (Pre-amplifier)
                         Multi device
                                                ETS-LINDGREN           7006-001          00160105                 N/A                   N/A
                          Controller
                      Wideband Radio
                       Communication                   R&S             CMW500              116254           June 07, 2018         June 07, 2019
                            Tester
                        Test Software                 Audix                e3                        Software Version: 9.160323


                                                    2/3/4G RF Test System Equipment List
                                                                                Serial                        Cal. date            Cal. Due date
          Used          Equipment             Manufacturer     Model No.
                                                                               Number                       (mm dd, yyyy)         (mm dd, yyyy)
                                                                            1316.3003K07
                          Receiver               R&S             ESR7                                       Dec. 10, 2017         Dec. 10, 2018
                                                                             -101181-K3
                      EXA Spectrum
                                                KEYSIGHT              N9010A           MY51440197            Dec.10, 2017         Dec. 10, 2018
                         Analyzer
                     Wideband Radio
                      Communication                 R&S              CMW500                116254           June 07, 2018         June 07, 2019
                          Tester
                        DC Source                KIKUSUI             PWR400L            LK003024            Sep. 14, 2018         Sep. 13, 2019
                     Temp & Humidity                                                   58566133290
                                                  Votisch             VT4002                                June 05, 2018         June 05, 2019
                         chamber                                                           020




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 9 of 29                          Report No.: 181027005RFM-1

4. TEST CONFIGURATION
   4.1 ENVIRONMENTAL CONDITIONS FOR TESTING
      4.1.1       Normal or Extreme Test Conditions
              Test Environment                                               Selected Values During Tests
                                                                                       Ambient
                Test Condition
                                                  Temperature (°C)                    Voltage (V)         Relative Humidity (%)
                      TN/VN                            +15 to +35                              3.7                            20 to 75
                      TL/VL                               -30                                  3.5                            20 to 75
                      TH/VL                               +50                                  3.5                            20 to 75
                      TL/VH                                -30                                 4.2                            20 to 75
                      TH/VH                                +50                                 4.2                            20 to 75
         Remark:
         1) The EUT just work in such extreme temperature of -30 °C to +50 °C and the extreme voltage of 3.5 V to
            4.2 V, so here the EUT is tested in the temperature of -30 °C to +50 °C and the voltage of 3.5 V to 4.2 V.
         2) VN: Normal Voltage; TN: Normal Temperature;
            TL: Low Extreme Test Temperature; TH: High Extreme Test Temperature;
            VL: Low Extreme Test Voltage; VH: High Extreme Test Voltage.




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 10 of 29                         Report No.: 181027005RFM-1

      4.2 TEST SETUP
      4.2.1       For Radiated Emissions test setup
                                                             Setup - 1_ERP Test setup




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 11 of 29                         Report No.: 181027005RFM-1

                                                             Setup - 2_EIRP Test setup




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 12 of 29                         Report No.: 181027005RFM-1

      4.2.2       For Conducted RF test setup




                                                                Normal Environment




                                                                Extreme Environment




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 13 of 29                         Report No.: 181027005RFM-1

      4.3 TEST CHANNELS
                                                                                                      RF Channel
                  Band                    Tx/Rx Frequency
                                                                               Low(L)                  Middle(M)                   High(H)
                                               Tx                           Channel 128               Channel 190               Channel 251
                   GSM
                                       (824 MHz ~ 849 MHz)                   824.2 MHz                 836.6 MHz                 848.8 MHz


      4.4 SYSTEM TEST CONFIGURATION
       For emissions testing, the equipment under test (EUT) setup to transmit continuously to simplify the
       measurement methodology. Care was taken to ensure proper power supply voltages during testing. During
       testing, radiated emission were performed with the EUT set to transmit at the channel with highest output power
       as worst-case scenario. It was powered by a 3.7Vdc rechargeable Li-on battery. Only the worst case data were
       recorded in this test report.

       Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
       available modulations, data rates, X/Y/Z axis, and antenna ports.

       All readings are extrapolated back to the equivalent three meter reading using inverse scaling with distance.
       Analyzer resolution is 100 kHz or greater for frequencies below 1000MHz. The resolution is 1 MHz or greater
       for frequencies above 1000MHz. The spurious emissions more than 20 dB below the permissible value are not
       reported.

       Radiated emission measurement were performed from the lowest radio frequency signal generated in the
       device which is greater than 9 kHz to the tenth harmonic of the highest fundamental frequency or to 40 GHz,
       whichever is lower.

      4.5 PRE-SCAN
       Pre-scan under all rate at lowest middle and highest channel, find the transmitter power as below:
       SIM 1 Card Conducted transmitter power measurement result.
                                       GSM 850 Maximum Average Power (dBm)
                Channel                     128                        190                       251
            Frequency(MHz)               824.2 MHz                836.6 MHz                  848.8 MHz
         GSM (GMSK, 1Tx-slot)                            32.69                              32.70                               32.67
         GPRS (GMSK, 1Tx-slot)                           32.63                              32.65                               32.66
         GPRS (GMSK, 2Tx-slot)                           31.02                              31.15                               31.21
         GPRS (GMSK, 3Tx-slot)                           29.43                              29.62                               29.70
         GPRS (GMSK, 4Tx-slot)                           27.95                              28.13                               28.34


       Pre-scan all mode, find worse case mode are chosen to the report, the worse mode applicability and tested
       channel detail as below:
                Band                          Radiated                                  Conducted
                                        1) GSM (GMSK, 1Tx-slot) Link                           1) GSM (GMSK,1Tx-slot) Link
               GSM/GPRS
                                        2) GPRS (GMSK, 1Tx-slot) Link                          2) GPRS (GMSK, 1Tx-slot) Link




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 14 of 29                         Report No.: 181027005RFM-1

5. RADIO TECHNICAL REQUIREMENTS SPECIFICATION
   5.1 REFERENCE DOCUMENTS FOR TESTING
          No.                      Identity                                             Document Title
                                                                Frequency allocations and radio treaty matters; general rules and
            1      FCC 47 CFR Part 2 Subpart J
                                                                regulations
            2      FCC 47 CFR Part 22 Subpart H                 Cellular Radiotelephone Service
                                                                Land Mobile FM or PM Communications Equipment Measurement
            3      ANSI/TIA-603-E-2016
                                                                and Performance Standards
            4      KDB 971168 D01                               KDB 971168 D01 Power Meas License Digital Systems v03r01


      5.2 EFFECTIVE RADIATED POWER (ERP)
         Test Requirement: FCC 47 CFR Part 2.1046(a) & FCC 47 CFR Part 22.913(a)
         Test Method:            KDB 971168 D01v03& ANSI/TIA-603-E-2016
         Limit:
         The ERP of mobile transmitters and auxiliary test transmitters must not exceed 7 Watts.
         Test Procedure:
         Test procedure as below:
         1) The EUT was powered ON and placed on a 0.8/1.5m high table at a 3 meter semi/fully Anechoic Chamber.
              The antenna of the transmitter was extended to its maximum length. Modulation mode and the measuring
              receiver shall be tuned to the frequency of the transmitter under test.
         2) The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
              of a variable-height antenna tower.
         3) The disturbance of the transmitter was maximized on the test receiver display by raising and lowering from
              1m to 4m the receive antenna and by rotating through 360°the turntable. After the fundamental emission
              was maximized, a field strength measurement was made.
         4) Steps 1) to 3) were performed with the EUT and the receive antenna in both vertical and horizontal
              polarization.
         5) The transmitter was then removed and replaced with another antenna. The center of the antenna was
              approximately at the same location as the center of the transmitter.
         6) A signal at the disturbance was fed to the substitution antenna by means of a non-radiating cable. With
              both the substitution and the receive antennas horizontally polarized, the receive antenna was raised and
              lowered to obtain a maximum reading at the test receiver. The level of the signal generator was adjusted
              until the measured field strength level in step 3) is obtained for this set of conditions.
         7) The output power into the substitution antenna was then measured.
         8) Steps 6) and 7) were repeated with both antennas polarized.
         9) Calculate power in dBm by the following formula:
                                  ERP(dBm) = Pg(dBm) – cable loss (dB) + antenna gain (dBd)
                                  EIRP(dBm) = Pg(dBm) – cable loss (dB) + antenna gain (dBi)
                                                         EIRP=ERP+2.15dB
              where:
              Pg is the generator output power into the substitution antenna.
         10) Test the EUT in the lowest channel, the middle channel the Highest channel
         11) The radiation measurements are performed in X, Y, Z axis positioning for EUT operation mode, and found
              the Y axis positioning which it is worse case.
         12) Repeat above procedures until all frequencies measured was complete.
                                          Frequency               Detector          RBW             VBW     Remark
         Receiver Setup:                30MHz-1GHz                  Peak          100kHz          300kHz     Peak
                                         Above 1GHz                 Peak           1MHz             3MHz     Peak
         Test Setup:                  Refer to section 4.2.1 for details.
         Instruments Used:            Refer to section 3 for details
         Test Mode:                   Link mode
         Test Results:                Pass
         Test Data:                   See table below


Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 15 of 29                         Report No.: 181027005RFM-1

                                                              Maximum ERP (dBm)
                                                                               Limit
                    Channel                              GSM                                                                   Result
                                                                              (dBm)
                    Lowest                               30.14                 38.45                                            Pass
                    Middle                               30.15                 38.45                                            Pass
                    Highest                              30.12                 38.45                                            Pass




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 16 of 29                         Report No.: 181027005RFM-1

      5.3 CONDUCTED OUTPUT POWER
         Test Requirement:            FCC 47 CFR Part 2.1046(a) & FCC 47 CFR Part 22.913(a)
         Test Method:                 ANSI/TIA-603-E-2016 & KDB 971168 D01v03r01
         Limit:
         The ERP of mobile transmitters and auxiliary test transmitters must not exceed 7 Watts.
         Test Procedure:
         The EUT was set up for the maximum power with GSM, GPRS, EDGE, WCDMA, CDMA2000, and LTE link
         data modulation and link up with simulator. Set the EUT to transmit under low, middle and high channel and
         record the power level shown on simulator.

         Note: The cable loss and attenuator loss were offset into measure device as an amplitude offset.
         Test Setup:           Refer to section 4.2.2 for details.
         Instruments Used: Refer to section 3 for details
         Test Mode:            Link mode
         Test Results:         Pass
         Test Data:            The full result refer to section 4.5 for details.




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 17 of 29                         Report No.: 181027005RFM-1

      5.4 PEAK-TO-AVERAGE RATIO
         Test Requirement:            FCC 47 CFR Part 22.913(a)
         Test Method:                 KDB 971168 D01v03r01
                                      In measuring transmissions in this band using an average power technique, the peak-
         Limit:
                                      to-average ratio (PAR) of the transmission may not exceed 13 dB
         Test Procedure:
         The transmitter output was connected to a calibrated coaxial cable and coupler, the other end of which was
         connected to a spectrum analyzer.
         a) Set resolution/measurement bandwidth ≥ signal’s occupied bandwidth
         b) Set the number of counts to a value that stabilizes the measured CCDF curve
         c) Record the maximum PAPR level associated with a probability of 0.1 %

         Note: The cable loss and attenuator loss were offset into measure device as an amplitude offset.
         Test Setup:           Refer to section 4.2.2 for details.
         Instruments Used: Refer to section 3 for details
         Test Mode:            Link mode
         Test Results:         Pass
         Test Data:            See table below

                                              GSM                         GPRS                         Limit
                Channel                                                                                                           Result
                                             1Tx-slot                    1Tx-slot                     (dBm)
                  Lowest                      1.03                         2.99                         13                          Pass
                 Middle                        3.02                        1.66                          13                         Pass
                 Highest                       4.74                        3.13                          13                         Pass




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 18 of 29                         Report No.: 181027005RFM-1

       The test plot as follows:
                            GSM 1Tx-slot                                                                GPRS 1Tx-slot
                                                                   Lowest Channel




                                                                    Middle Channel




                                                                   Highest Channel




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 19 of 29                         Report No.: 181027005RFM-1

      5.5 99%&26DB BANDWIDTH
         Test Requirement: FCC 47 CFR Part 2.1049(h) & FCC 47 CFR Part 22.917(b)
         Test Method:           ANSI/TIA-603-E-2016 & KDB 971168 D01v03r01
         Limit:                 No Limit
         Test Procedure:
         The transmitter output was connected to a calibrated coaxial cable and coupler, the other end of which was
         connected to a spectrum analyzer. The occupied bandwidth was measured with the spectrum analyzer at the
         low, middle and high channel in each band. The 99% and -26dB bandwidths was also measured and recorded.

         Note: The cable loss and attenuator loss were offset into measure device as an amplitude offset.
         Test Setup:           Refer to section 4.2.2 for details.
         Instruments Used: Refer to section 3 for details
         Test Mode:            Link mode
         Test Results:         Pass
         Test Data:            See table below

                                                               99% & 26 dB Bandwidth
                                                                      Frequency                      26 dB BW                    99% BW
                Test Mode                     Channel                    (MHz)                         (kHz)                       (kHz)
                                                  128                    824.2                         317.2                      243.28
              GSM 1Tx-slot                        190                       836.6                       315.1                      241.72
                                                  251                       848.8                       317.5                      244.59
                                                  128                       824.2                       312.8                      241.70
             GPRS 1Tx-slot                        190                       836.6                       324.7                      244.04
                                                  251                       848.8                       322.6                      245.07




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 20 of 29                         Report No.: 181027005RFM-1

       The test plot as follows:
                                GSM                                                                           GPRS
                                                                   Lowest Channel




                                                                    Middle Channel




                                                                   Highest Channel




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 21 of 29                         Report No.: 181027005RFM-1

      5.6 BAND EDGE AT ANTENNA TERMINALS
         Test Requirement: FCC 47 CFR Part 2.1051 & FCC 47 CFR Part 22.917(a)
         Test Method:          ANSI/TIA-603-E-2016 & KDB 971168 D01v03r01
         Limit:
         The power of any emission outside of the authorized operating frequency ranges must be attenuated below
         the transmitting power (P) by a factor of at least 43 + 10 log(P) dB. The emission limit equal to -13 dBm.
         Test Procedure:
         The transmitter output was connected to a calibrated coaxial cable and coupler, the other end of which was
         connected to a spectrum analyzer.
         For each band edge measurement:
         1) Set the spectrum analyzer span to include the block edge frequency.
         2) Set a marker to point the corresponding band edge frequency in each test case.
         3) Set display line at -13 dBm
         4) Set resolution bandwidth to at least 1% of emission bandwidth.
         5) Set spectrum analyzer with RMS detector.
         6) Record the max trace plot into the test report

         Note: The cable loss and attenuator loss were offset into measure device as an amplitude offset.
         Test Setup:           Refer to section 4.2.2 for details.
         Instruments Used: Refer to section 3 for details
         Test Mode:            Link mode
         Test Results:         Pass




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 22 of 29                         Report No.: 181027005RFM-1

       The test plot as follows:
                            GSM 1Tx-slot                                                                GPRS 1Tx-slot
                                                                   Lowest Channel




                                                                   Highest Channel




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 23 of 29                         Report No.: 181027005RFM-1

      5.7 SPURIOUS EMISSIONS AT ANTENNA TERMINALS
         Test Requirement: FCC 47 CFR Part 2.1051 & FCC 47 CFR Part 22.917(a)(b)
         Test Method:           ANSI/TIA-603-E-2016 & KDB 971168 D01v03r01
         Limit:
         The power of any emission outside of the authorized operating frequency ranges must be attenuated below
         the transmitting power (P) by a factor of at least 43 + 10 log(P) dB. The emission limit equal to -13 dBm.
         Test Procedure:
         The EUT makes a phone call to the communication simulator. All measurements were done at low, middle
         and high operational frequency range. b. Measuring frequency range is from 30 MHz to the tenth harmonic of
         the highest fundamental frequency or to 40 GHz, whichever is lower. Set RBW & VBW to 100 kHz for the
         measurement below 1 GHz, and 1 MHz for the measurement above 1 GHz.

         Note: The cable loss and attenuator loss were offset into measure device as an amplitude offset.
         Test Setup:           Refer to section 4.2.2 for details.
         Instruments Used: Refer to section 3 for details
         Test Mode:            Link mode
         Test Results:         Pass




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 24 of 29                         Report No.: 181027005RFM-1

       The test plot as follows:
                            GSM 1Tx-slot                                                                GPRS 1Tx-slot
                                                                   Lowest Channel




                                                                    Middle Channel




                                                                   Highest Channel




       Remark:
       1) All the above conduction data, the fundamental frequency is not marked, it may exceed the limit, please
       ignore it.




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 25 of 29                         Report No.: 181027005RFM-1

      5.8 FIELD STRENGTH OF SPURIOUS RADIATION
         Test Requirement:            FCC 47 CFR Part 2.1053 & FCC 47 CFR Part 22.917(a)(b)
         Test Method:                 ANSI/TIA-603-E-2016 & KDB 971168 D01v03r01
         Receiver Setup:
                   Frequency                      Detector                    RBW                        VBW                     Remark
             0.009 MHz-30 MHz                       Peak                     10 kHz                    30 KHz                      Peak
                30 MHz-1 GHz                    Quasi-peak                  100 kHz                    300 KHz                     Peak
                 Above 1 GHz                      Peak                       1 MHz                      3 MHz                      Peak
         Limits:
         The power of any emission outside of the authorized operating frequency ranges must be attenuated below
         the transmitting power (P) by a factor of at least 43 + 10 log(P) dB. The emission limit equal to -13 dBm.
         Test Setup:              Refer to section 4.2.1 for details.
         Test Procedures:
         1. Scan up to 10th harmonic, find the maximum radiation frequency to measure.
         2. The technique used to find the Spurious Emissions of the transmitter was the antenna substitution method.
              Substitution method was performed to determine the actual ERP/EIRP emission levels of the EUT.
         Test procedure as below:
         1) The EUT was powered ON and placed on a 0.8/1.5m high table at a 3 meter semi/fully Anechoic Chamber.
              The antenna of the transmitter was extended to its maximum length. Modulation mode and the measuring
              receiver shall be tuned to the frequency of the transmitter under test.
         2) The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
              of a variable-height antenna tower.
         3) The disturbance of the transmitter was maximized on the test receiver display by raising and lowering from
              1m to 4m the receive antenna and by rotating through 360°the turntable. After the fundamental emission
              was maximized, a field strength measurement was made.
         4) Steps 1) to 3) were performed with the EUT and the receive antenna in both vertical and horizontal
              polarization.
         5) The transmitter was then removed and replaced with another antenna. The center of the antenna was
              approximately at the same location as the center of the transmitter.
         6) A signal at the disturbance was fed to the substitution antenna by means of a non-radiating cable. With
              both the substitution and the receive antennas horizontally polarized, the receive antenna was raised and
              lowered to obtain a maximum reading at the test receiver. The level of the signal generator was adjusted
              until the measured field strength level in step 3) is obtained for this set of conditions.
         7) The output power into the substitution antenna was then measured.
         8) Steps 6) and 7) were repeated with both antennas polarized.
         9) Calculate power in dBm by the following formula:
                                   ERP(dBm) = Pg(dBm) – cable loss (dB) + antenna gain (dBd)
                                   EIRP(dBm) = Pg(dBm) – cable loss (dB) + antenna gain (dBi)
                                                          EIRP=ERP+2.15dB
               where:
               Pg is the generator output power into the substitution antenna.
         10) Test the EUT in the lowest channel, the middle channel the Highest channel
         11) The radiation measurements are performed in X, Y, Z axis positioning for EUT operation mode, and found
              the Y axis positioning which it is worse case.
         12) Repeat above procedures until all frequencies measured was complete.
         Equipment Used:          Refer to section 3 for details.
         Test Result:             Pass
         The measurement data as follows:




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 26 of 29                         Report No.: 181027005RFM-1

       Radiated Emission Test Data
        GSM 1Tx-slot_Lowest Channel
         Horizontal
                                                          Correction
                     Frequency           Reading                                Result
           No.                                               factor                            Limit (dBm)        Margin (dB)          Remark
                        (MHz)              (dBm)                                (dBm)
                                                              (dB)
            1         1648.400             -47.95             3.59              -44.36             -13.00            -31.36                 Peak
            2         8242.000             -45.76             18.37             -27.39             -13.00            -14.39                 Peak
            3         9066.200             -45.80             18.74             -27.06             -13.00            -14.06                 Peak



         Vertical
                                                          Correction
                     Frequency           Reading                                Result
           No.                                               factor                            Limit (dBm)        Margin (dB)          Remark
                        (MHz)              (dBm)                                (dBm)
                                                              (dB)
            1         1648.400             -35.10             3.59              -31.51             -13.00            -18.51                 Peak
            2         6593.600             -54.87             19.11             -35.76             -13.00            -22.76                 Peak
            3         7417.800             -52.29             18.30             -33.99             -13.00            -20.99                 Peak




         GSM 1Tx-slot_Middle Channel
         Horizontal
                                                          Correction
                     Frequency           Reading                                Result
           No.                                               factor                            Limit (dBm)        Margin (dB)          Remark
                        (MHz)              (dBm)                                (dBm)
                                                              (dB)
            1         1673.200             -44.10             3.88              -40.22             -13.00            -27.22                 Peak
            2         4183.000             -55.43             13.67             -41.76             -13.00            -28.76                 Peak
            3         9202.600             -48.29             19.21             -29.08             -13.00            -16.08                 Peak



         Vertical
                                                          Correction
                     Frequency           Reading                                Result
           No.                                               factor                            Limit (dBm)        Margin (dB)          Remark
                        (MHz)              (dBm)                                (dBm)
                                                              (dB)
            1         1673.200             -34.77             3.88              -30.89             -13.00            -17.89                 Peak
            2         7529.400             -55.27             18.31             -36.96             -13.00            -23.96                 Peak
            3         8366.000             -53.79             18.27             -35.52             -13.00            -22.52                 Peak




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 27 of 29                         Report No.: 181027005RFM-1

         GSM 1Tx-slot_Highest Channel
         Horizontal
                                                          Correction
                     Frequency           Reading                                Result
           No.                                               factor                            Limit (dBm)        Margin (dB)          Remark
                        (MHz)              (dBm)                                (dBm)
                                                              (dB)
            1         1697.600             -49.97             4.17              -45.80             -13.00            -32.80                 Peak
            2         8488.000             -51.93             18.26             -33.67             -13.00            -20.67                 Peak
            3         9336.800             -47.02             19.52             -27.50             -13.00            -14.50                 Peak



         Vertical
                                                          Correction
                     Frequency           Reading                                Result
           No.                                               factor                            Limit (dBm)        Margin (dB)          Remark
                        (MHz)              (dBm)                                (dBm)
                                                              (dB)
            1         1697.600             -34.93             4.17              -30.76             -13.00            -17.76                 Peak
            2         7639.200             -53.25             18.42             -34.83             -13.00            -21.83                 Peak
            3         8488.000             -50.69             18.26             -32.43             -13.00            -19.43                 Peak


       Remark:
       1) All tested is under the condition of the main wave is filtered out.




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 28 of 29                         Report No.: 181027005RFM-1

      5.9 FREQUENCY STABILITY
         Test Requirement:            FCC 47 CFR Part 2.1055 & FCC 47 CFR Part 22.355
         Test Method:                 ANSI/TIA-603-E-2016 & KDB 971168 D01v03r01
                                      The carrier frequency shall not depart from the reference frequency in excess of ±2.5
         Limits:
                                      ppm for mobile stations.
         Test Setup:                  Refer to section 4.2.2 for details.
         Test Procedures:
         1)    Use CMW 500 or CMU 200 with Frequency Error measurement capability.
              a) Temp. = −30° to + 50°C
              b) Voltage =low voltage, 3.5 Vdc, Normal, 3.7 Vdc and High voltage, 4.2 Vdc.
         2) Frequency Stability vs Temperature:
         The EUT is place inside a temperature chamber. The temperature is set to 20ºC and allowed to stabilize.
         After sufficient soak time, the transmitting frequency error is measured. The temperature is increased by 10
         degrees, allowed to stabilize and soak, and then the measurement is repeated. This is repeated until +50ºC
         is reached.
         3) Frequency Stability vs Voltage:
         The peak frequency error is recorded (worst-case).
         Equipment Used:      Refer to section 3 for details.
         Test Result:         Pass

                             Channel/
                                               Voltage        Temperature         Deviation         Deviation           Limit
          Modulation        Frequency                                                                                                  Pass/ Fail
                              (MHz)              (Vdc)              (℃)           (Hz)                (ppm)             (ppm)
                                                                       GSM 1Tx-slot
                                                   VL                               9                 0.0108            ± 2.5               Pass
                                                   VN                TN            11                 0.0131            ± 2.5               Pass
                                                   VH                               7                 0.0084            ± 2.5               Pass
                                                                     50            13                 0.0155            ± 2.5               Pass
                                                                     40            12                 0.0143            ± 2.5               Pass
                                                                     30            16                 0.0191            ± 2.5               Pass
              GMSK          190 / 836.6
                                                                     20            12                 0.0143            ± 2.5               Pass
                                                   VN                10            13                 0.0155            ± 2.5               Pass
                                                                      0             8                 0.0096            ± 2.5               Pass
                                                                     -10           11                 0.0131            ± 2.5               Pass
                                                                     -20           17                 0.0203            ± 2.5               Pass
                                                                     -30           13                 0.0155            ± 2.5               Pass




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 29 of 29                         Report No.: 181027005RFM-1


APPENDIX 1 PHOTOS OF TEST SETUP


          See test photos attached in Appendix 1 for the actual connections between Product and support equipment.




APPENDIX 2 PHOTOS OF EUT CONSTRUCTIONAL DETAILS

                                          Refer to Appendix 2 for EUT external and internal photos.



                                                                 *** End of Report ***




       The test report is effective only with both signature and specialized stamp. The result(s) shown in this report refer
       only to the sample(s) tested. Without written approval of UnionTrust, this report can’t be reproduced except in full.




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com



Document Created: 2019-04-21 16:29:37
Document Modified: 2019-04-21 16:29:37